• Title/Summary/Keyword: LF(Low Frequency)

Search Result 164, Processing Time 0.026 seconds

Etching characteristics of ArF and EUV resists in dual-frequency superimposed capacitively coupled $CF_{4}/O_{2}/Ar$ and $CF_{4}/CHF_{3}/O_{2}$/Ar plasmas

  • Gwon, Bong-Su;Kim, Jin-Seong;Park, Yeong-Rok;An, Jeong-Ho;Mun, Hak-Gi;Jeong, Chang-Ryong;Heo, Uk;Park, Ji-Su;Lee, Nae-Eung;Lee, Seong-Gwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2009.05a
    • /
    • pp.252-253
    • /
    • 2009
  • In this study, the deformation and etch characteristics of ArF and EUV photoresists were compared in a dual frequency superimposed capacitively coupled plasma (DFS-CCP) etcher systems using $CF_{4}/O_{2}/Ar$ and $CF_{4}/CHF_{3}/O_{2}/Ar$ mixture gas chemistry which are typically used for BARC open and $Si_{3}N_{4}$ teching chemistry, respectively. Etch rate of the resists tend to increase with low-frequency source power ($P_{LF}$) and high-frequency source ($f_{HF}$). The etch rate of ArF resist was hgither than that of EUV resist.

  • PDF

Psychological and Physiological Responses to the Rustling Sounds of Korean Traditional Silk Fabrics

  • Cho, Soo-Min;Yi, Eun-Jou;Cho, Gil-Soo
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.450-456
    • /
    • 2006
  • The objectives of this study were to investigate physiological and psychological responses to the rustling sound of Korean traditional silk fabrics and to figure out objective measurements such as sound parameters and mechanical properties determining the human responses. Five different traditional silk fabrics were selected by cluster analysis and their sound characteristics were observed in terms of FFT spectra and some calculated sound parameters including level pressure of total sound (LPT), Zwicker's psychoacoustic parameters - loudness(Z), sharpness(Z), roughness(Z), and fluctuation strength(Z), and sound color factors such as ${\Delta}L\;and\;{\Delta}f$. As physiological signals, the ratio of low frequency to high frequency (LF/HF) from the power spectrum of heart rate variability, pulse volume (PV), heart rate (HR), and skin conductance level (SCL) evoked by the fabric sounds were measured from thirty participants. Also, seven aspects of psychological state including softness, loudness, sharpness, roughness, clearness, highness, and pleasantness were evaluated when each sound was presented. The traditional silk fabric sounds were likely to be felt as soft and pleasant rather than clear and high, which seemed to evoke less change of both LF/HF and SCL indicating a negative sensation than other fabrics previously reported. As fluctuation strength(Z) were higher and bending rigidity (B) values lower, the fabrics tended to be perceived as sounding softer, which resulted in increase of PV changes. The higher LPT was concerned with higher rating for subjective loudness so that HR was more increased. Also, compression linearity (LC) affected subjective pleasantness positively, which caused less changes of HR. Therefore, we concluded that such objective measurements as LPT, fluctuation strength(Z), bending rigidity (B), and compression linearity (LC) were significant factors affecting physiological and psychological responses to the sounds of Korean traditional silk fabrics.

A study on characteristics of the autonomic nervous system in students with Keongke - Using Heart Rate Variability and Pupil Size Variability - (경계(驚悸) 증상을 지닌 학생 집단의 자율 신경 기능 특성에 대한 연구 - 심박변이도와 동공크기 변이도를 중심으로 -)

  • Lee, Seung-Gi;Lee, Jeong-Chan;Kim, Ji-Eun;Park, Kyung-Mo;Kang, Hee-Chul
    • Journal of Oriental Neuropsychiatry
    • /
    • v.17 no.2
    • /
    • pp.133-145
    • /
    • 2006
  • Objective : The purpose of this experimental-controlled study was to investigate the characteristics of the autonomic nervous system in students with Keongke by using HRV(Heart rate variability) and PSV(Pupil size variability). Method : The study group was consisted of 11 students with self recognition as the experimental group, and 25 normal students as the control group. Informations on gender and age were obtained by medical charts and personal interviews. By using heart rate variability and pupil size variability, we measured the value of HRT(Heart rate), SDNN(Standard deviation of NN intervals), LFnorm(Low frequency normalization), HFnorm(High frequency normalization), LF/HF ratio, Pupil area, B.S.(Basic size), C.R.(Max Constriction Rate) and 1s.d.(1sec Dilation Rate). I compared the degrees of the sympathetic and parasympathetic activity. Result : 1. In the result of heart rate variability between experimental and control group, none of the parameters of experimental group were significantly different from control group. And even though there were no statistical significance, there were some numerical differences in SDNN, LF norm, HF norm. 2. In pupil size variability, C.R. and 1s.d. of the experimental group were increased compared to control group. Conclusion : The study results suggest that the group with Keongke has differences of autonomic nervous system as compared to those in normal state. Measurement value of PSV is a new technical approach to estimate the autonomic nervous system.

  • PDF

Review of Association between Air Pollution and Heart Rate Variability (HRV) (대기오염과 심박변이도(Heart Rate Variability, HRV)의 연관성에 대한 고찰)

  • Guak, Sooyoung;Lim, Chaeyun;Lee, Kiyoung;Park, Ji Young
    • Journal of Environmental Health Sciences
    • /
    • v.41 no.4
    • /
    • pp.223-230
    • /
    • 2015
  • Objectives: There is considerable evidence that polluted ambient air contributes to the risk of cardiovascular morbidity and mortality. Heart rate variability (HRV) is defined as the variation in heartbeat intervals and has been reported as a biological marker of cardiovascular disease. This article reviews the existing literature in order to examine the association between air pollution and HRV. Methods: Literature was searched using Web of Science with the key words of "air pollution", "heart rate variability" and other related terms. A total of 156 articles were listed. For review, 21 of those listed publications were chosen after excluding studies regarding chamber studies, occupational environment, secondhand smoke and automobile exhaust. Results: Research methods employed in the publications were classified by type of participants (elderly/adult), air pollution monitoring (ambient/personal) and HRV monitoring (continuous/spot). Among HRV parameters, power in the low frequency range (LF), power in the high frequency range (HF) and standard deviation of all NN intervals (SDNN) were all associated with air pollutants. The chosen studies were mostly based on elderly populations. In studies based on continuous HRV monitoring, LF and SDNN significantly decreased when $PM_{2.5}$ exposure increased. Conclusion: Continuous HRV monitoring combined with personal exposure monitoring has been one of the most common study methods in recent publications. We expect that this review will be useful for the study of the association between air pollution and cardiovascular effects using HRV.

The Effects of Paced Breathing in Specific Respiration Rate on Heart Rate Variability (특정 호흡수에서 행한 통제호흡이 심박변이도에 미치는 영향)

  • Kim, Ji-Hwan;Kim, Byoung-Soo;Park, Seong-Sik;Lee, Yong-Jae;Keum, Na-Rae;Bae, Hyo-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.28 no.2
    • /
    • pp.123-131
    • /
    • 2016
  • Objectives We observed what effects of Paced Breathing(PB) in specific respiration rate have on heart rate variability (HRV) according to Sasang Constitution.Methods HRV of 72 healthy participants in sitting position was recorded while they carried out usual breathing, 0.2Hz, 0.1Hz, and 0.05Hz PB each 5 minutes in consecutive order. Five minute of relaxation was permitted between each breathing. Finally, HRV indices were statictically analyzed of 32 participants (SOEUM: 11, SOYANG: 10, TAEEUM: 11) after data out of accord with respiration rate or outliers were excluded.Results and Conclusions According to respiration rates, there was no statistical significance of HRV among Sasang Constitution. Regardless of Sasang Constituion, 0.2Hz PB increased mean heart rate and decreased natural logarithmic low frequency(lnLF) oscillation of HRV without the change of natural logarithmic high frequency(lnHF), while 0.1Hz PB increased lnLF and standard deviation of N-N interval(SDNN), and slightly decreased lnHF without the change of mean heart rate. 0.05 Hz PB also showed the same effect as 0.1Hz PB, but was impracticable.

Comparative Analysis of the Heart Rate Variability, Body Composition, Digital Infrared Thermal Imaging and Electro Pulse Graph Between Primary Dysmenorrhea Patients and Secondary Dysmenorrhea Patients (원발성 월경통 환자와 속발성 월경통 환자의 심박변이도, 체성분, 적외선 체열 촬영, 맥전도 검사 상 특징 비교 고찰)

  • Lee, Su-Jeong;Ji, Hae-Ri;Hwang, Deok-Sang;Lee, Chang-Hoon;Jang, Jun-Bock;Lee, Jin-Moo
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.32 no.4
    • /
    • pp.25-38
    • /
    • 2019
  • Objectives: The purpose of this study is to analysis differences of heart rate variability (HRV), body composition, digital infrared thermal imaging (DITI), and electro pulse graph by whether there are some causes of dysmenorrhea or not. Methods: We studied 89 patients who took at least one test among HRV, Body composition, DITI, and electro pulse graph visiting Kyung Hee University Hospital at Gangdong from March 1, 2014 to May 7, 2019. Results: There were statistically significant differences in Low frequency (LF), LF norm and High frequency norm (HF norm) of HRV between primary dysmenorrhea patients and secondary dysmenorrhea patients. There were statistically significant differences in Body Mass Index (BMI) and body fat percentage of Body composition between two groups. But both BMI were included in normal range. There were no statistically significant difference in DITI results. And there was significant difference of Estimated circulation resistance (ECR) between two groups. Conclusions: The results suggest that hormone imbalance of secondary dysmenorrhea patients can affect HRV results. And because of high ECR, phlegm pathology can be more considered in secondary dysmenorrhea patients. Further study should be conducted to confirm the results of body composition and DITI differences.

Effect of Ultrasound Therapy at the ST11 on Sympathetic Nervous System Change: A Prospective Randomized Controlled Study (기사혈(氣舍穴, ST11)에 적용한 혈위 초음파요법이 교감신경계에 미치는 영향: 전향적 무작위 대조군 연구)

  • Shinwoo Kang;Dongho Keum
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.4
    • /
    • pp.167-184
    • /
    • 2023
  • Objectives This study was designed to assess the effectiveness of ultrasound therapy at the ST11 for regulation of sympathetic hyperactivity. Methods Forty healthy adult subjects were assigned to experimental group and control group. After taking mental stress, ultrasound therapy was applied at the ST11 in experimental group and sham-ultrasound therapy was applied in control group. The evaluation of sympathetic activity was measured by blood pressure, pulse rate, and heart rate variability at 3 times (Time 1: before the stress stimulation, Time 2: after the stress stimulation, Time 3: after the intervention). The primary end point was consisted of normalized (norm) low frequency (LF)/high frequency (HF) ratio, LF (norm), HF (norm). The secondary end point was consisted of systolic blood pressure, diastolic blood pressure, pulse rate, mean heart rate, standard deviation of NN intervals, root mean square of the successive differences, total power (log). Results After the stress stimulation, all subjects showed sympathetic hyperactivity. After the intervention, the experimental group showed lower sympathetic activity than the control group. Comparing the Time 3 and Time 1, the experimental group showed no significantly differences in sympathetic activity while the control group showed higher sympathetic activity in Time 3 than Time 1. Comparing the Time 3 and Time 2, the experimental group showed lower sympathetic activity in Time 3 than Time 2 while the control group showed higher sympathetic activity in Time 3 than Time 2. Conclusions We suggest that the ultrasound therapy at ST11 can decrease sympathetic activity in sympathetic hyperactivity condition.

Low-Complexity Joint Estimation Algorithms of Frequency Offset and Carrier Phase for Digital Communication Systems (디지털 통신 시스템에서 주파수 옵셋과 반송파 위상의 간단한 동시 추정 알고리듬)

  • Hong Dae-Ki;Kang Sung-Jin;Ju Min-Chul;Kim Yong-Sung;Cho Jin-Woong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.11C
    • /
    • pp.1581-1591
    • /
    • 2004
  • In this paper, we investigate the design of three low-complexity joint estimation algorithms(LJEAs) for frequency offset and carrier phase. The proposed LJEAs are based on the interpolation technique of correlation values of the received signal in frequency and phase domains. With these algorithms, the estimation ranges $\Delta$f$_{d}$${\times}$T$_{s}$ . are less than 1/2N$_{s}$ , and 1/N$_{s}$ which are comparable to conventional algorithms. The Proposed LJEAs require only 2N$_{s}$ or 4N$_{s}$ complex multiplications which are very simple compared with the conventional algorithms. Nevertheless the estimation accuracies of the LJEAs are as good as those of the conventional algorithms. Suitable areas of application include joint estimation of frequency offset and carrier phase in burst-mode digital transmission such as satellite communications.

A High Linear And Low Noise COMOS RF Front-End For 2.4GHz ZigBee Applications (지그비(ZigBee) 응용을 위한 고선형, 저잡음 2.4GHz CMOS RF 프론트-엔드(Front-End))

  • Lee, Seung-Min;Jung, Chun-Sik;Kim, Young-Jin;Baek, Dong-Hyun
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.6
    • /
    • pp.604-610
    • /
    • 2008
  • A 2.4 GHz CMOS RF front-end using for ZigBee application is described The front-end consists of a low noise amplifier and a down-mixer and uses a 2 MHz IF frequency. A common source with resistive feedback and an inductive degeneration are adopted for a low noise amplifier, and a 20 dB gain control step is digitally controlled. A passive mixer for low current consumption is employed. The RF front-end is implemented in 0.18 ${\mu}m$IP6M CMOS process. The measured performance is 4.44 dB NF and -6.5 dBm IIP3 while consuming 3.28 mA current from a 1.8 V supply.

  • PDF

State of the Art on Terrestrial Radionavigation System and Its Applications for Maritime PNT Service

  • Seo, Kiyeol;Fang, Tae Hyun;Park, Sang Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.11 no.4
    • /
    • pp.229-238
    • /
    • 2022
  • This paper addresses on the International technical trends, standards, and development status of terrestrial radionavigation system to provide more accurate and fail-safe Positioning, Navigation, and Timing (PNT) Information available in maritime navigation environment. We analyze the performance result of pilot service in enhanced Long range navigation (eLoran) testbed environment using Low Frequency (LF) signal, and describe the development status of Ranging-Mode (R-Mode) system using Medium Frequency (MF) and Very High Frequency (VHF) to meet the Harbor Entrances and Approaches (HEA) requirement of International Maritime Organization (IMO) within 10m position accuracy. Furthermore, we present an architecture for integrated service of satellite-terrestrial navigation system and future maritime applicable fields. As the core information infrastructure of future navigation for 4th industrial revolution, this paper will be contributed to determining the direction of present and future to provide fail-safe PNT service with Global Navigation Satellite System (GNSS) based on the technical enhancement of terrestrial integrated navigation system.