• Title/Summary/Keyword: LEXAN

Search Result 7, Processing Time 0.018 seconds

Measurement of Detection Efficiency of Plastic Track Detector to ${\alpha}-particle$ (고체비적검출기의 알파선 검출효율 측정에 관한 연구)

  • Park, Young-Woong;Yang, Hyun-Soo
    • Journal of Radiation Protection and Research
    • /
    • v.21 no.3
    • /
    • pp.167-173
    • /
    • 1996
  • The calibration method for the detection efficiency of solid state track detector to alpha is presented, and the detection efficiency of CN-85 and LEXAN to alpha is measured by this method. The results are 97% and 57% in CN-85 and LEXAN, respectively. The reason for a better result in CN-85 in not only the high sensitivity but also the low energy dependency with comparing for LEXAN. The peak detection efficiency is 3MeV and 1.8MeV in CN-85 and LEXAN, respectively.

  • PDF

Determination of the Uranium Backgrounds in Lexan Films for Single Particle Analysis using FT-TIMS technique

  • Park, Su-Jin;Park, Jong-Ho;Lee, Myung-Ho;Song, Kyu-Seok
    • Mass Spectrometry Letters
    • /
    • v.2 no.2
    • /
    • pp.57-60
    • /
    • 2011
  • As background significantly affects measurement accuracy and a detection limit in determination of the trace amounts of uranium, it is necessary to determine the impurities in the Lexan detector film for single particle measurements by thermal ionization mass spectrometry coupled with fission track technique (FT-TIMS). We have prepared various micro sizes of the blank Lexan detector film using a micromanipulation technique for uranium measurements by TIMS. Few tens of fg of uranium background with no remarkable dependency on the film sizes were observed in the blank Lexan films with the sizes from $50{\times}50\;{\mu}m^2$ to $300{\times}300\;{\mu}m^2$. Based on the determination of the uranium background in the Lexan film, any background correction is necessary in the isotopic analysis of a uranium single particle with micron sizes when the particle bearing Lexan film is dissected with less than $300{\times}300\;{\mu}m^2$ size. The isotopic analysis of a uranium particle in U030 standard material using TIMS was carried out to verify the applicability of the Lexan film to the single particle analysis with high accuracy and precision.

($LEXAN^{(R)}$ for Flexible OLED Display Technology

  • Yan, Min;Ezawa, Hiro
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.614-615
    • /
    • 2005
  • The use of plastic substrates enables new applications, such as flexible display devices, and other flexible electronic devices, using low cost, roll-to-roll (R2R) fabrication technologies. One of the limitations of polymeric substrate in these applications is that oxygen and moisture rapidly diffuse through the material and subsequently degrade the electro-optical devices. GE Global Research (GEGR) has developed a plastic substrate technology comprised of a superior high-heat polycarbonate ($LEXAN^{(R)}$) substrate film and a unique transparent coating package that provides the ultrahigh barrier (UHB) to moisture and oxygen,chemical resistance to solvents used in device fabrications, and a high performance transparent conductor. This article describes the coating solutions for polycarbonate ($LEXAN^{(R)}$) films and its compatibility with OLED device fabrication processes.

  • PDF

Flexible Ultra-high Gas Barrier Substrate for Organic Electronics

  • Yan, Min;Erlat, Ahmet Gun;Zhao, Ri-An;Scherer, Brian;Jones, Cheryl;Smith, David J.;McConnelee, Paul A.;Feist, Thomas;Duggal, Anil
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.445-446
    • /
    • 2007
  • The use of plastic substrates enables new applications, such as flexible display devices, and other flexible electronic devices, using low cost, rollto-roll (R2R) fabrication technologies. One of the limitations of polymeric substrate in these applications is that oxygen and moisture rapidly diffuse through the material and subsequently degrade the electro-optical devices. GE Global Research (GEGR) has developed a plastic substrate technology comprised of a superior high-heat polycarbonate (LEXAN(R)) substrate film and a unique transparent coating package that provides the ultrahigh barrier (UHB) to moisture and oxygen, chemical resistance to solvents used in device fabrications, and a high performance transparent conductor. This article describes the coating solutions for polycarbonate (LEXAN(R)) films and its compatibility with OLED device fabrication processes.

  • PDF

Detection of Alpha Tracks of Boron by Nuclear Reaction with Neutron (중성자 핵반응에 의한 보론의 알파트랙 검출)

  • Sohn, Se Chul;Pyo, Hyung Yeal;Park, Yong Jun;Jee, Kwang Yong;Kim, Won Ho
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2004
  • The detection efficiencies of the several solid track detectors were investigated for the determination of boron content in aqueous solution by using the alpha muti-Radioisotope(RI) source. Polycarbonate (Lexan and CR-39) and cellulose nitrate (CN-85 and LR-115) were selected as materials for alpha track detection of boron. Alpha muti-RI source, uranium metal particles and boron standard solution were used for alpha emission. In this study, four solid track detectors(CN-85, LR-115, Lexan and CR-39) were characterized under various etching conditions as well as neutron irradiation conditions. As a result, the CN-85 was turned out to be best to provide good efficiency among the four detectors. The selected solid track detector was utilized for the determination of trace amount of boron in aqueous sample and its results were discussed in the text.

Determination of Uranium Concentration in Solid- and Liquid-state Geological Materials by Fission Track Registration Technique and its Applicability (피션트랙 검출기법에 의한 고체 및 액체상태 지질물질의 우라늄 정량과 그 적용성)

  • Shin, Seong-Cheon
    • The Journal of the Petrological Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.77-90
    • /
    • 2015
  • The fission track registration techniques for accurate determinations of uranium in solid- and liquid-state geological materials were recommended and their applicability were examined. The determination of uranium can be achieved by optical counting of neutron-induced fission tracks of $^{235}U$ registered on solid-state track detectors under high magnification. In a dry registration method using powdered pellets of rocks (e.g., granite and coal) showing good uranium-affinity, it was not easy to decide an overall mean concentration over the total sample owing to track-clusters caused by frequent presence of uranium-bearing minerals. Separate scanning for homogeneous and track-clustered parts may be an alternative choice. Assuring the homogeneity over the whole sample, high reproducibilities were confirmed both from duplicate detections using mica and Lexan polycarbonate detectors and from multiple measurements at different thermal neutron fluences. The wet registration method using sealed quartz tubes is recommended to overcome the common heterogeneity in uranium concentrations of $10^1ppm$ and more. Adopting the wet registration, the uranium homogeneity was recovered below the $10^0ppm$ level and the lower detection limit was proved to reach without difficulty the $10^2ppb$ (i.e. $ng\;g^{-1}$) level.

Investigating the effects of a range shifter on skin dose in proton therapy

  • Ming Wang;Lei Zhang;Jinxing Zheng;Guodong Li;Wei Dai;Lang Dong
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.215-221
    • /
    • 2023
  • Proton treatment may deliver a larger dose to a patient's skin than traditional photon therapy, especially when a range shifter (RS) is inserted in the beam path. This study investigated the effects of an RS on skin dose while considering RS with different thicknesses, airgaps and materials. First, the physical model of the scanning nozzle with RS was established in the TOol for PArticle Simulation (TOPAS) code, and the effects of the RS on the skin dose were studied. Second, the variations in the skin dose and isocenter beam size were examined by reducing the air gap. Finally, the effects of different RS materials, such as polymethylmethacrylate (PMMA), Lexan, polyethylene and polystyrene, on the skin dose were analysed. The results demonstrated that the current RS design had a negligible effect on the skin dose, whereas the RS significantly impacted the isocenter beam size. The skin dose was increased considerably when the RS was placed close to the phantom. Moreover, the magnitude of the increase was related to the thickness of the inserted RS. Meanwhile, the results also revealed that the secondary proton primarily contributed to the increased skin dose.