• Title/Summary/Keyword: LEEM

Search Result 994, Processing Time 0.024 seconds

Effects of Myopia Alleviation Lenses in accordance with Parents' Refractive Errors (부모의 굴절이상에 따른 근시완화렌즈 효과)

  • Cho, Yoon Chul;Kang, JoongGu;Leem, Hyun Sung
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.569-577
    • /
    • 2018
  • Purpose : The study looked at how effective each group wearing MyoVison lens, MC lens, and Single Vision lensdepending on their parents' myopia condition. Methods : The study observed the changeof spherical equivalent among customers, who visited between January 2010 and December 2016,of an optical shop in Incheon Metropolitan City. And we observed MyoVision 152 eyes, MC Lens 86 eyes and Single Vision lens 270 eyes. This study was conducted using SPSS ver18, which analyzes the changes in average values of MyoVision, MC Lens, and Single Vision for a year.In each group, the differences in the group were compared using the Paired T-test and then one-way ANOVA (post-hoc; Bonferroni) Results : Group-to-group comparisons showed that MyoVision and MC Lens have a shorterinhibition than Single Vision. In particular, MyoVisionand MC Lens showed different relief effects depending on the degree of refraction of parents.When both parents had normal refractive, the change between MyoVision and Single Vision lens was $-0.35{\pm}0.05D$. When the father had a refraction MC lens were $-0.36{\pm}0.14D$ more effective than Single Vision. When only the mother had refraction, the mean value between MyoVision and Single Vision lens was $-0.37{\pm}0.06D$, and the mean between MC lens and Single Vision lens was $-0.38{\pm}0.08D$. And when both parents had refraction problems, the mean value change between MyoVision and Single Vision lens was $-0.28{\pm}0.07D$, and $-0.31{\pm}0.07D$, respectively. Conclusion : MyoVision and MC Lens appeared to have no effect on the functions of mitigating myopia in within group comparisons, but MyoVision and MC Lens showed reducing myopia than Single Vision in between group.

Current Status of Informed Consent Form for Acupotomy in Korean Medicine Hospitals and Development of a Standard Informed Consent Form Using Delphi Method (한방병원의 침도 시술 동의서의 현황 조사와 델파이 기법을 활용한 표준 시술 동의서 개발)

  • Jihun Kim;Bonhyuk Goo;Hyongjun Kim;Kyoungsuk Seo;Myungjin Oh;Myungseok Ryu;Sang-Hoon Yoon;Kwang Ho Lee;Hyun-Jong Lee;Jungtae Leem;Hyungsun Jun;Jeong Ihn Sook;Sung Woon Choi;Tae Wook Lee;Yeonhak Kim;Yoona Oh;Kunhyung Kim;Gi Young Yang;Eunseok Kim
    • The Journal of Korean Medicine
    • /
    • v.45 no.1
    • /
    • pp.182-201
    • /
    • 2024
  • Objectives: This study was conducted to develop a standard acupotomy consent form that takes into account the unique characteristics of Korean Medicine. The study was motivated by the increasing importance of patient autonomy and the growing number of legal disputes related to medical malpractice in the clinical field of Korean Medicine. Methods: The analysis phase of the study involved a survey of the current status of acupotomy consent forms in Korean Medicine hospitals nationwide. The items of each form were analyzed based on the contents of the Medical law and the standard contract for medical procedures of the Fair Trade Commission (FTC). In the development and evaluation phase, the items and contents of the acupotomy consent form were evaluated using a 5-point Likert scale and content validity was assessed through two rounds of Delphi surveys. In the improvement phase, the contents of the consent form were revised based on the results of a survey of inpatient and outpatient patients in the Department of Acupuncture and Moxibustion at Pusan National University Korean Medicine Hospital, and real-time online meeting. The final version of the standard acupotomy consent form was completed after undergoing proofreading and corrections by a linguistics expert. Results: Only 30% of Korean Medicine hospitals have implemented acupotomy consent forms. The items of the consent forms did not fully include the items presented in the Medical act and the standard contract for medical procedures of the FTC. To address this issue, two rounds of Delphi surveys and a real-time discussion were conducted with a panel of 12 experts on 27 preliminary items of consent forms. The items and contents that met the criteria for content validity ratio, convergence, and consensus were derived. Based on the derived items and content, a standard acupotomy consent form was developed. Conclusions: The standard consent form for acupotomy is anticipated to ensure patient autonomy and enhance transparency and liability in acupotomy. Furthermore, it is expected to serve as evidence in case of medical disputes related to acupotomy and contribute as a reference document for the development of standard consents forms for various procedures of Korean Medicine. However, the limitations of the study include that the survey of consent forms was limited to only training hospitals of Korean Medicine, and the standard consent form is only applicable to adults in Korea. Future studies are needed to address these limitations.

Sodium and Potassium Content of School Meals for Elementary and Junior High School Students in Daegu, Masan, Gwangju, and Jeju (대구, 마산, 광주, 제주지역 학교급식의 나트륨 및 칼륨 함량 분석)

  • Lim, Hyeon-Sook;Ko, Yang Sook;Shin, Dongsoon;Heo, Young-Ran;Chung, Hae-Jung;Chae, In-Sook;Kim, Hwa Young;Kim, Mi-Hye;Leem, Dong-Gil;Lee, Yeon-Kyung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.8
    • /
    • pp.1303-1317
    • /
    • 2013
  • The purpose of this study was to determine the sodium (Na) and potassium (K) content of school meals served in elementary and junior high school in Korea. In this study, 872 kinds of school meal dishes were collected from twelve elementary and twelve junior high schools located in four different cities in Korea (Daegu, Masan, Gwangju, and Jeju). The dishes were classified into three main categories; staple dish, subsidiary dish, and dessert. Each main category was further sub-classified into 4 kinds of staple dishes, 15 kinds of subsidiary dishes, and 5 kinds of dessert dishes. The Na and K content of dishes were then analyzed by atomic absorption spectroscopy. The Na content of individual dishes showed considerable differences, ranging from 9 to 2,717 mg/100 g. Among the staple dishes, cooked rice contained relatively less Na, but other staple dishes such as a la carte, noodle, and rice-gruel contained considerably high amounts of Na. Regarding the subsidiary dishes, the Na content of salad was low, but those of Jangachi, stir-fried dishes, and kimchi were considerably high. Among the dessert dishes, beverages, fruit, and milk/dairy products contained relatively low amount of Na, while rice cakes and baked goods, and snacks contained noticeably high amounts of Na. Unlike the Na content, the K content between the dishes did not show much variability. Cooked rice and rice cakes contained relatively low amounts of K, similar to other dishes, and ranged from 104 to 220 mg/100 g. The Na/K ratio was especially high in rice cakes and Jangachi, while of the ratio in beverages, milk/dairy products, salad, and fruit were pretty low. The total content of Na and K and the Na/K ratio of elementary school meals were 974 mg, 378 mg and 2.7, respectively, and those in junior high school meals was 1,466 mg, 528 mg and 3.0. The results show that most school meals provide a significant amount of Na but significantly small amounts of K, as suggested by the Dietary Reference Intakes for Koreans.

Analysis of the Eyeglasses Supply System for Ametropes in ROK Military (한국군 비정시자용 안경의 보급체계 분석)

  • Jin, Yong-Gab;Koo, Bon-Yeop;Lee, Woo-Chul;Yoon, Moon-Soo;Park, Jin-Tae;Lee, Hang-Seok;Lee, Kyo-Eun;Leem, Hyun-Sung;Jang, Jae-Young;Mah, Ki-Choong
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.579-588
    • /
    • 2018
  • Purpose : To analyze the eyeglasses supply system for ametropic soldiers in ROK military. Methods : We investigated and analyzed the supply system of eyeglasses for the ametropic soldiers provided by the Korean military. The refractive powers and corrected visual acuity were measured for 37 ametropic soldiers who wear insert glasses for ballistic protective and gas-masks supplied by the military based on their habitual prescriptions. Full correction of refractive error was prescribed for subjects having less than 1.0 of distance visual acuity, and comparison was held for inspecting the changes in corrected visual acuity. Suggestions were provided for solving the issues regarding current supplying system, and this study investigated the applicabilities for utilizing professional optometric manpower. Results : The new glasses supplied by army for ametropic soldiers were duplicated from the glasses they worn when entering the army. The spherical equivalent refractive powers of the conventional, ballistic protective and gas-mask insert glasses supplied for 37 ametropic soldiers were $-3.47{\pm}1.69D$, $-3.52{\pm}1.66D$ and $-3.55{\pm}1.63D$, respectively, and the spherical equivalent refractive power of full corrected glasses was $-3.79{\pm}1.66D$, which showed a significant difference(p<0.05). The distant corrected visual acuity measured at high and low contrast(logMAR) of conventional, ballistic protective and gas-mask insert glasses were $0.06{\pm}0.80$, $0.21{\pm}0.82$, $0.15{\pm}0.74$, $0.34{\pm}0.89$, $0.10{\pm}0.70$ and $0.22{\pm}0.27$, respectively, while the corrected visual acuity by full corrected glasses were increased to $0.02{\pm}1.05$, $0.10{\pm}0.07$, $0.09{\pm}0.92$, $0.26{\pm}0.10$, $0.04{\pm}1.00$ and $0.19{\pm}1.00$, respectively. There was a significant difference(p<0.05) except for the case of the low contrast corrected visual acuity of the conventional and gas-mask insert glasses. The procedure for ordering, dispensing, and supplying military glasses consists of 5 steps, and it was found that approximately two weeks or more are required to supply from the initial examination. Conclusion : The procedure of supplying the military glasses showed three issues: 1) a lack of refraction for prescription system, 2) relatively long length of time required for supplying the glasses, 3) an inaccurate power of supplied glasses. In order to solve those issues, in the short term, education is necessarily required for soldiers on the measurement of the refractive powers, and in the near future, further standard procedures for prescription of glasses as well as the securement of optometric manpower are expected.