• Title/Summary/Keyword: LED stand

Search Result 50, Processing Time 0.028 seconds

Determination of Inorganic Phosphate in Paprika Hydroponic Solution using a Laboratory-made Automated Test Stand with Cobalt-based Electrodes (코발트전극과 자동시험장치를 이용한 파프리카 양액 내 무기인산 측정)

  • Kim, Hak-Jin;Son, Dong-Wook;Kwon, Soon-Goo;Roh, Mi-Young;Kang, Chang-Ik;Jung, Ho-Seop
    • Journal of Biosystems Engineering
    • /
    • v.36 no.5
    • /
    • pp.326-333
    • /
    • 2011
  • The need for rapid on-site monitoring of hydroponic macronutrients has led to the use of ion-selective electrodes, because of their advantages over spectrophotometric methods, including simple methodology, direct measurement of analyte, sensitivity over a wide concentration range, and low cost. Stability and repeatability of response can be a concern when using multiple ion-selective electrodes to measure concentrations in a series of samples because accuracy might be limited by drifts in electrode potential. A computer-based measurement system could improve accuracy and precision because of both consistent control of sample preparation and easy calibration of sensors. Our goal was to investigate the applicability of a cobalt-based electrode used in conjunction with a laboratory-made automated test stand for quantitative determination of ${PO_4}^-$ in hydroponic solution. Six hydroponic solutions were prepared by diluting highly concentrated paprika hydroponicsolution to provide a concentration range of 1 to 300 ppm $PO_4$-P. A calibration curve relating electrode response to phosphate in paprika hydroponic solution titrated to pH 4 with 0.025M KHP was developed based on the Nikolskii-Eisenman equation with a coefficient of determination ($R^2$) of 0.94. The laboratory-made test stand consisting of three cobalt-based electrodes measured phosphate concentrations similar to those obtained with standard laboratory methods (a regression slope of 0.98 with $R^2$ = 0.80). However, the y intercept was relatively high, 30 ppm, probably due to the relatively large amount of variation present among multiple measurements of the same sample. Further studies on the high variation in EMFs obtained with cobalt electrodes during replicate measurements were required for P estimations comparable to those obtained with standard laboratory instruments.

A Study on the Production of a Convergence Color-Responsive Lighting Bookcase (색상에 반응하는 융복합 조명 책꽂이 제작에 관한 연구)

  • Kang, Hee-Ra
    • Journal of Digital Convergence
    • /
    • v.13 no.6
    • /
    • pp.267-273
    • /
    • 2015
  • Recently, a wide range of products incorporating cutting-edge technology are being introduced in various sectors of design. Belkin's WeMo or Phillips' Hue are representative examples. In this context, the color-responsive lighting bookcase is a design product that would satisfy the needs of contemporary consumers who seek entertainment in their purchases. By installing lightings that change color according to the user's behavior, this design reconceptualizes the bookcase as a source of entertainment rather than a mundane object of household furnishing. The lighting apparatus can be detached and reattached, serving as stand-alone equipment. The lighting bookcase is modularized, comprising extensions equipped with MCU (Micro Controller Unit), RGB LED and color sensors. The bookcase as a whole is extendable towards four directions up to nine units with the lighting bookcase at the center. The extended, multiple lighting bookcases are wired to receive power from the main bookcase, and are equipped with RGB LEDs but not with MCUs or color sensors. Receiving power and color signals from the main lighting bookcase, the sub-bookcases feature changing shades of color. Also, it includes IoT(internet of Things). This study is a proposal of a design product, modularized to control the shades of the bookcase lighting using these sensors.

Development of a Test Stand for Measuring Ink Jetting Performance (잉크젯 토출 특성 평가 장치 개발)

  • Kwon, Kye-Si
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.45-50
    • /
    • 2008
  • An ink jetting measurement system has been developed such that the velocity as well as the volume of ink droplets can be measured. In order to measure the ink droplet, a strobe LED light was synchronized to the droplet firing signal in order to obtain frozen droplet images. Then, a LabVIEW based software was developed for the analysis of the droplet image. For the efficient droplet analysis, a user generated rectangular shaped ROI (Region of Interest) was used. By using ROI, the ink droplet image can be easily isolated from the other structures such as printhead and the processing area can be minimized.

ESTIMATING CROWN PARAMETERS FROM SPACEBORNE HIGH RESOLUTION IMAGERY

  • Kim, Choen;Hong, Sung-Hoo
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.247-249
    • /
    • 2007
  • Crown parameters are important roles in tree species identification, because the canopy is the aggregate of all the crowns. However, crown measurements with spaceborne image data have remained more difficult than on aerial photographs since trees show more structural detail at higher resolutions. This recognized problem led to the initiation of the research to determine if high resolution satellite image data could be used to identify and classify single tree species. In this paper, shape parameters derived from pixel-based crown area measurements and texture features derived from GLCM parameters in QuickBird image were tested and compared for individual tree species identification. As expected, initial studies have shown that the crown parameters and the canopy texture parameters provided a differentiating method between coniferous trees and broad-leaved trees within the compartment(less than forest stand) for single extraction from spaceborne high resolution image.

  • PDF

Efficient Vibration Analysis of Stadium Stands (경기장 관람석의 효율적인 진동해석)

  • 김기철;이동근
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.293-303
    • /
    • 2002
  • Recently, the use of the high strength materials and development of construction techniques have resulted in more flexible and longer spanning in the stadium systems. So the natural frequency of stadium structures are became low. Stadium stand could be led to significant dynamic response as like resonance due to spectator rhythmical activities. The accurate analysis of dynamic behavior of stadium systems and the precise investigation of the dynamic loads on stadium structures are demanded for effective design. It is desirable to apply measured dynamic loads created by spectator activities because these dynamic loads are not easy to express numerical formula. As the floor mesh of stadium stand is refined, the number of divided elements increases in numerical analysis. the rise of the number of elements makes the numbers of nodal points increased and numerous computer memory required. So it is difficult to analysis refine full model of stadium structures by using the commercial programs. In this study, the various dynamic loads induced by spectator movements are measured and analyzed. And a new modeling method that reduce the nodal points are introduced. Vibration analysis of stadium stands is executed to inspect accuracy and efficiency of proposed method in this paper.

Long-Term Follow-Up Results of Anterior Cervical Inter-Body Fusion with Stand-Alone Cages

  • Kim, Woong-Beom;Hyun, Seung-Jae;Choi, Hoyong;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.59 no.4
    • /
    • pp.385-391
    • /
    • 2016
  • Objective : The purpose of this study was to evaluate long-term follow-up radiologic/clinical outcomes of patients who underwent anterior cervical discectomy and inter-body fusion (ACDF) with stand-alone cages (SAC) in a single academic institution. Methods : Total 99 patients who underwent ACDF with SAC between February 2004 and December 2012 were evaluated retrospectively. A total of 131 segments were enrolled in this study. Basic demographic information, radiographic [segmental subsidence rate, fusion rate, C2-7 global angle, and segmental angle changes)/clinical outcomes (by Odom's criteria and visual analog score (VAS)] and complications were evaluated to determine the long-term outcomes. Results : The majority were males (55 vs. 44) with average age of 53.2. Mean follow-up period was 62.9 months. The segmental subsidence rate was 53.4% and fusion rate was 73.3%. In the subsidence group, anterior intervertebral height (AIH) had more tendency of subsiding than middle or posterior intervertebral height (p=0.01). The segmental angle led kyphotic change related to the subsidence of the AIH. Adjacent segmental disease was occurred in 18 (18.2%) patients. Total 6 (6%) reoperations were performed at the index level. There was no statistical significance between clinical and radiological outcomes. But, overall long-term clinical outcome by Odom's criteria was unsatisfactory (64.64%). The neck and arm VAS score were increased by over time. Conclusion : Long-term outcomes of ACDF with SAC group were acceptable but not satisfactory. For optimal decision making, more additional comparative long-term outcome data is needed between ACDF with SAC and ACDF with plating.

A Study on MD5 Security Routing based on MANET (MANET 기반 MD5 보안 라우팅에 관한 연구)

  • Lee, Cheol-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.4
    • /
    • pp.797-803
    • /
    • 2012
  • Recently demands in construction of the stand-alone networks and interconnection between convergence devices have led an increase in research on and much attention has been paid to the application of MANET as a Ubiquitous network which is growing fast. With performance both as hosts and routers, easy network configuration, and fast response, mobile nodes participating in MANET are suitable for Embedded computing, but have vulnerable points, such as lack of network scalability and dynamic network topology due to mobility, passive attacks, active attacks, which make continuous security service impossible. In this study, hashed AODV routing is used to protect from counterfeiting messages by malicious nodes in the course of path finding and setting, and disguising misrouted messages as different mobile nodes and inputting them into the network.

A Routing Security Authentication using S-EKE in MANET Environments (MANET 환경에서 S-EKE를 이용한 라우팅 보안 인증)

  • Lee, Cheol-Seung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.4
    • /
    • pp.433-438
    • /
    • 2014
  • The demanding in construction of the stand-alone networks and interconnection between convergence devices have led an increase in research on MANET and the application of MANET has been paid much attention as a Ubiquitous computing which is growing fast in the field of computer science. With performance both as hosts and routers, easy network configuration, and fast response, mobile nodes participating in MANET are suitable for Embedded computing but have vulnerable points, about lack of dynamic network topology due to mobility, network scalability, passive attacks, and active attacks which make it impossible to manage continuous security authentication service. In this study, proposes S-EKE authentication mechanism for a robust authentication based on MANET and through identify wireless environment security vulnerabilities, currently being used in OTP S/Key and DH-EKE analyzes.

Viable Alternatives to in vivo Tests for Evaluating the Toxicity of Engineered Carbon Nanotubes

  • Kwon, Soon-Jo;Eo, Soo-Mi
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.1-7
    • /
    • 2012
  • Carbon nanotubes (CNTs) stand at the frontier of nanotechnology and are destined to stimulate the next industrial revolution. Rapid increase in their production and use in the technology industry have led to concerns over the effects of CNT on human health and the environment. The prominent use of CNTs in biomedical applications also increases the possibility of human exposure, while properties such as their high aspect ratio (fiber-like shape) and large surface area raise safety concerns for human health if exposure does occur. It is crucial to develop viable alternatives to in vivo tests in order to evaluate the toxicity of engineered CNTs and develop validated experimental models capable of identifying CNTs' toxic effects and predicting their level of toxicity in the human respiratory system. Human lung epithelial cells serve as a barrier at the interface between the surrounding air and lung tissues in response to exogenous particles such as air-pollutants, including CNTs. Monolayer culture of the key individual cell types has provided abundant fundamental information on the response of these cells to external perturbations. However, such systems are limited by the absence of cell-cell interactions and their dynamic nature, which are both present in vivo. In this review, we suggested two viable alternatives to in vivo tests to evaluate the health risk of human exposure to CNTs.

Selfie-stick Analysis through Ansys and New Design Proposal (Ansys를 이용한 셀카봉 해석 및 새로운 설계 제안)

  • Lee, JungHyeok;Jang, Hoik
    • Proceeding of EDISON Challenge
    • /
    • 2015.03a
    • /
    • pp.467-475
    • /
    • 2015
  • In this paper, the FREECAD 0.14 was used for modeling conventional Selfie-stick and the newly proposed Selfie-stick design. The purpose of this paper is to demonstrate the utility of FREECAD 0.14, which is open-source and still in development for further use. After modeling the conventional Selfie-stick, CatiyaV5 was used to assemble FREECAD 0.14 drawn elements. Main advance in newly designed Selfie-stick is the portability. To improve portability of the Selfie-stick, folding mechanism was adopted from folding LED stands. Several mechanisms were adopted to improve user convenience as well. Ansys 14.0 was used for structural analyses of conventional Selfie-stick model and the newly designed model as well. Several simplifications for the models were needed to process the analyses. When analyzing the newly designed model various materials were used one by one to find compatible composition. Using Aluminum alloys for the stick and the hand grip was found to be compatible. FREECAD was useful for suggestion of the newly designed model but not so much useful to design an actual product. Various efforts would make FREECAD the best choice for industrial use for free as it is named.

  • PDF