• Title/Summary/Keyword: LED Glow

Search Result 7, Processing Time 0.025 seconds

Effect of Day-length Extension Treatment Using LED on Growth and Flowering of Freesia hybrid 'Yvonne' (LED를 이용한 장일 처리가 프리지아(Freesia hybrida) '이본느'의 생육 및 개화에 미치는 영향)

  • Lee, Jin-Jae;Hwang, Ji-Hye
    • Horticultural Science & Technology
    • /
    • v.32 no.6
    • /
    • pp.794-802
    • /
    • 2014
  • The aim of this study was to determine the effect of day-length extension treatment using LED lighting (blue, green, red, or 3 mixed) on vegetative growth and flowering of freesia 'Yvonne', in comparison to that using glow lamps and metal halide lamps. Lighting treatments were imposed from 5 PM to 8 PM for 150 days from after flower bud differentiation to flowering end. For the period from leaf emergence to floral bud formation, no light source affected plant height but the number of leaves was decreased by the metal halide lamp. The highest SPAD value in the flower bud developing period occurred in the metal halide lamp treatment. The time of flowering was advanced by blue or green LED treatment compared to the no lighting control. The green LED lighting advanced flowering by 6 and 8 days compared to no lighting and metal halide lamp treatment, respectively. The blooming period tended to be shortened by the red LED treatment. As for the flower characteristics of 'Yvonne', floret length and width, and the weight of cut flowers were highest in the metal halide lamp treatment. Red LED decreased corm width and weight of 'Yvonne' while glow lamp decreased height and weight. Starch contents in corm were not influenced by the lighting source. Our results indicate that the green LED lighting advanced the time of flowering and the metal halide lamp was good for cut-flower quality.

The Present Condition of LED Industry and Necessity of Promote it (뉴스초점 - LED산업 현황 및 육성의 필요성)

  • Ha, Jae-Chan
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.5
    • /
    • pp.41-45
    • /
    • 2009
  • The last century of lighting has been dominated by incandescent, fluorescent and high-intensity discharge(HID)light sources. In the late 1970's, after green LEDs were invented, Dr. Ching Tang at Eastman Kodak discovered that sending an electrical impulse through carbon compound caused such material glow. Present day LED commercial packages have reached 100 lm/W, comparable to the efficacies of fluorescent and certain HID lamps. LED products available today are market as "Green-Industry" but actually low light output compared to typical light sources. The combination of high price and low light output make them a poor replacement for current technology. It is very important to compare new LED products to the most efficient conventional technology that could be used for any specific application. As LED technology advances, costs decrease, and efficiency improves, LEDs will build market share in the general illumination market.

  • PDF

An Integrated System for Radioluminescence, Thermoluminescence and Optically Stimulated Luminescence Measurements

  • Park, Chang-Young;Park, Young-Kook;Chung, Ki-Soo;Lee, Jong-Duk;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.4
    • /
    • pp.160-169
    • /
    • 2018
  • Background: This study aims to develop an integrated optical system that can simultaneously or selectively measure the signals obtained from radioluminescence (RL), thermoluminescence (TL), and optically stimulated luminescence (OSL), which are luminescence phenomena of materials stimulated by radioactivity, heat, and light, respectively. The luminescence mechanism of various materials could be investigated using the glow curves of the luminescence materials. Materials and Methods: RL/TL/OSL integrated measuring system was equipped with a X-ray tube (50 kV, $200{\mu}A$) as an ionizing radiation source to irradiate the sample. The sample substrate was used as a heating source and was also designed to optically stimulate the sample material using various light sources, such as high luminous blue light emitting diode (LED) or laser. The system measured the luminescence intensity versus the amount of irradiation/stimulation on the sample for the purpose of measuring RL, TL and OSL sequentially or by selectively combining them. Optical filters were combined to minimize the interference of the stimulation light in the OSL signal. A long-pass filter (420 nm) was used for 470 nm LED, an ultraviolet-pass filter (260-390 nm) was used for detecting the luminescence of the sample by PM tube. Results and Discussion: The reliability of the system was evaluated using the RL/OSL characteristics of $Al_2O_3:C$ and the RL/TL characteristics of LiF:Mg,Cu,Si, which were used as dosimetry materials. The RL/OSL characteristics of $Al_2O_3:C$ showed relatively linear dose-response characteristics. The glow curve of LiF:Mg,Cu,Si also showed typical RL/OSL characteristics. Conclusion: The reliability of the proposed system was verified by sequentially measuring the RL characteristics of radiation as well as the TL and OSL characteristics by concurrent thermal and optical stimulations. In this study, we developed an integrated measurement system that measures the glow curves of RL/TL/OSL using universal USB-DAQs and the control program.

The Overall Performance Improvement of Microbial Fuel Cells Connected in Series with Dairy Wastewater Treatment

  • Choudhury, Payel;Bhunia, Biswanath;Bandyopadhyay, Tarun Kanti;Ray, Rup Narayan
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.101-111
    • /
    • 2021
  • To improve the potential of single chamber microbial fuel cells (SCMFCs) as an applicable technology, the main challenge is a practical application for larger scales bioenergy production from potent exoelectrogenic microorganism with real dairy wastewater. To increase power generation, three individual MFCs were together operated in series best under the fed batch condition for 15 days. The volume of MFC 1 and MFC 2 is "300 mL" and MFC 3 is "500 mL" respectively. The individual MFCs 1, MFC 2 and MFC 3 gives an open circuit voltage of 0.60 V, 0.66 V and 0.55 V and result in total working voltage when connected in series of 1.745V, which lead an LED to glow. The maximum power densities obtained from MFC 1, MFC 2 and MFC 3 are 62 mW/㎡, 50 mW/㎡ and 45 mW/㎡ (normalized to the surface area of the anodic electrode, which was 50 ㎠ for all three MFCs), and corresponding to current densities of 141 mA/㎡, 155 mA/㎡ and 123 mA/㎡, respectively. Therefore this work suggests the cheapest way to connect microbial fuel cells in series to gain power with the lowest operating cost and chemical oxygen demand (COD) removal.

Fundamental study of electrolyte cathode atomic discharge for development of on-line monitoring system (On-line monitoring system 개발에 관한 음극 액상 글로우 방전의 기초 연구)

  • Kim, Kyung-Mi;Woo, Young-A;Cho, Won-Bo;Kim, Hyo-Jin
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.496-501
    • /
    • 2002
  • The electrolyte cathode glow discharge (ELCAD) is a new optical system for direct determination of trace heavy metals in flowing water. ELCAD has been successfully developed for on-line monitoring of heavy metals in flowing water. The application of an atmospheric glow discharge between an electrolyte solution cathode and a platinum rod anode led to the development of stable discharge. The fundamental aspects of new plasma source have been investigated. The fundamental study of ELCAD system has been measured plasma temperature using Einstein-Boltzmann equation after searching Fe atomic emission lines. The spectrum of each elements such as Cu, Pb, Fe, Ni and Cr show only major elemental line and no ionic line possibly due to low temperature plasma source. The detection limits of each elements are also investigated. These informations show that this type of plasma may apply for monitoring of heavy metals in waste water which consists of complex matrix.

New Light Fiber BLU System for Large LCD Display

  • Chung, Man-Young;Park, Tong-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2002.07c
    • /
    • pp.1398-1400
    • /
    • 2002
  • A new PLF-BLU (Plastic Light Fiber-Back Light Unit) using side glowing light fiber rods array for the 42" LCD TV display has been evelopedd. The light fibers were 14mm in diameter and 50cm long pure transparent acrylic rods of 1.49 refractive index. Fine seratees were made on the flat side of rod. extremely bright incandscent light from lamp fed into the fiber si scattered at scratches then emerges through the surface of rod. A typical PLF-BLU system consists of 24 PLFs produced side glow of brightness of 4,500cd/㎡ to 6,500cd/㎡. New PLF-BLU is proved to be a BLU of rigid, bright, no heat generation, and low power consumption, hence a prospective BLU system for very and/or ultra large size TVs. A new LED-PLF-BLU system considered to be a revolutionary to break-through of the BLU technologies has also been developed, and is decribed briefly.

  • PDF

Characterizing light pollution in national parks during peak and off-peak tourist seasons using nighttime satellite images (야간위성영상을이용한국립공원탐방성수기와비수기의빛공해특성분석)

  • Cho, Woo;Sung, Chan-Yong;Ki, Kyong-Seok
    • Korean Journal of Environment and Ecology
    • /
    • v.28 no.4
    • /
    • pp.484-489
    • /
    • 2014
  • In this paper, we examined factors that influenced light pollution in Korean national parks during peak and off-peak tourist seasons. Cloud-and moonlight-free nighttime satellite images that were collected during October 2012(for peak season) and January 2013(for off-peak season) by the Day and Night Band (DNB) of the Visible Infrared Imaging Radiometer Suite (VIIRS) sensor were used to estimate the levels of light pollution in 19 national parks (excluding the Bukhansan and Mudeungsan National Parks). Bootstrapping regression analyses were conducted to examine the effects of socioeconomic and policy factors on light pollution in the study national parks for peak and off-peak tourist seasons, separately. The characteristics of light pollution in the national parks varied by season. During the peak tourist season, light pollution in the national parks were affected more by night lights nearby the parks than those within in the parks, while in the off-peak season, light sources in the parks were more important. Scattering of light emitted from hotels and other recreational facilities outside the parks that led to the sky glow effect can be attributed to the greater impact of night lights nearby the parks during the peak season. This result suggests that regulating light pollution nearby the park areas is needed to mitigate light pollution in the national parks, especially in a peak tourist season.