• Title/Summary/Keyword: LED광원

Search Result 614, Processing Time 0.025 seconds

Optimal Cultivar Selection of Kohlrabi for Hydroponics Culture in a Closed-type Plant Factory System (완전제어형 식물공장내 수경재배용 콜라비 품종 선발)

  • Uoon, Chan-Il;Cha, Mi-Kyung;Jeon, Yoon-A;Cho, Young-Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.297-300
    • /
    • 2017
  • Plant factory can control artificially the environments for crop cultivation, so they can produce high quality agricultural products all year round. This study was carried to select suitable kohlrabi cultivar for hydroponics in a closed-type plant factory system. We used three cultivars of red kohlrabi, 'Asac kohl', 'Kolibri', and 'Purple king' as plant materials. The artificial light source was LED light, light intensity and photoperiod were $249{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$ and 12/12 hours (day/night period), respectively. Hydroponic cultivation type was used circulating deep flow technique. At 43 days after transplanting, fresh weight of whole plant and tuber and leaf area were not significantly different among cultivars. Shoot dry weight and tuber dry weight were highest in 'Asac kohl' cultivar, and number of leaves was highest in 'Purple king' cultivar. Sugar content and yield were highest in 'Asac kohl' cultivar. Considering the growth and marketable yields, 'Asac kohl' was the optimal kohlrabi cultivar for hydroponic cultivation in a closed-type plant factory system.

A Measurement System for Color Environment-based Human Body Reaction (색채 환경 기반의 인체 반응 정보 측정 시스템)

  • Kim, Ji-Eon;Jeong, Chang-Won;Joo, Su-Chong
    • Journal of Internet Computing and Services
    • /
    • v.17 no.2
    • /
    • pp.59-65
    • /
    • 2016
  • The result of analyzing the cognitive reaction due to the color environment has been applied to various filed especially in medical field. Moreover, the study about the identification of patient's condition and examination the brain activity by collecting the bio-signal based on the color environment is being actively conducted. Even though, there were a variety of experiments by convention the color environment using a light or LED color, it still has a problem that affects the psychological information. Therefore, our proposed system using a HMD (Head Mounting display) to provide a completed color environment condition. This system uses the BMS(Biomedical System) to collect the biometric information which responds to the specific color condition and the human body response information can be measured by the development the Memory and Attention test on Mobile phone. The collection of Biometric information includes electro cardiogram(ECG), respiration, oxygen saturation (Sp02), Bio-impedance, blood pressure will store in the database. In addition, we can verify the result of the human body reaction in the color environment by Memory and Attention application. By utilizing the reaction of the human body information that is collected thought the proposed system, we can analyze the correlation between the physiological information and the color environment. And we also expect that this system can apply to the medical diagnosis and treatment. For future work, we will expand the system for prediction and treatment of Alzheimer disease by analyzing the visualization data through the proposed system. We will also do evaluation on the effectiveness of the system for using in the rehabilitation program.

Optical Properties of the Eu2+ Doped Li2SrSiO4-αNα (Li2SrSiO4-αNα에 첨가된 Eu2+의 광학적 특성)

  • Namkhai, Purevdulam;Kim, Taeyoung;Woo, Hyun-Joo;Jang, Kiwan;Jeong, Jung Hyun
    • New Physics: Sae Mulli
    • /
    • v.68 no.11
    • /
    • pp.1196-1202
    • /
    • 2018
  • $Li_2Sr_{1-x}Eu_xSiO_{4-{\alpha}}N_{\alpha}$ ($Li_2SrSiO_{4-{\alpha}}N_{\alpha}:Eu^{2+}$) phosphors were synthesized by using a solid state reaction (SSR) method with submicron $Si_3N_4$ and nano $Si_3N_4$ powders as the sources of Si and N, and the optical properties of those phosphors were studied. The studied phosphors showed efficient excitation characteristics over the broad range from 230 to 530 nm. Also, They showed broad emission spectra covering a range from 500 to 700 nm, with a peak at 568 nm, which was shifted longer wavelength by 18 nm as compared with that of commercial $YAG:Ce^{3+}$. Combined with a 450 nm blue LED chip, the results support the application of the $Li_2SrSiO_{4-{\alpha}}N_{\alpha}:Eu^{2+}$ phosphor as a luminescent material for a white-light source thaat is warmer than the commercial $YAG:Ce^{3+}$ white-light source. In addition, the $Li_2SrSiO_{4-{\alpha}}N_{\alpha}$ phosphors prepared from a submicron $Si_3N_4$ powder was found to emit a previously unreported self-activated luminescence in $Li_2SrSiO_{4-{\alpha}}N_{\alpha}$.

Nonthermal Sterilization of Pathogenic Escherichia coli by Intense Pulsed Light Using a Batch System (회분식 광펄스 처리에 의한 병원성 대장균의 비가열 살균)

  • Kim, Ae-Jin;Shin, Jung-Kue
    • Korean Journal of Food Science and Technology
    • /
    • v.47 no.1
    • /
    • pp.81-86
    • /
    • 2015
  • Intense pulsed light (IPL), a nonthermal technology, has attracted increasing interest as a food processing technology. However, its efficacy in inactivating microorganisms has not been evaluated thoroughly. In this study, we investigated the influence of IPL treatment on the inactivation of Escherichia coli O157:H7 depending on light intensity, treatment time, and pulse number. Increased light intensity from 500 V to 1,000 V, raised the inactivation rate at room temperature. At 1000 V, the cell numbers were reduced by 7.1 log cycles within 120 s. In addition, increased pulse number or decreased distance between the light source and sample surface also led to an increase in the inactivation rate. IPL exposure caused a significant increase in the absorption at 260 nm of the suspending agent used in our experiments. This indicates that IPL-treated cells were damaged, consequently releasing intracellular materials. The growth of IPL-irradiated cells were delayed by about 5 h. The degree of damage to the cells after IPL treatment was confimed by transmission electron microscopy.

Luminescence properties of novel Sr-Y-Si-Oxynitride yellow phosphor for LED applications (LED용 Sr-Y-Si-계 산질화물 황색 형광체의 발광 특성)

  • Jeong, Ok Geun;Park, Jong Cheon;Ryu, Jeong Ho;Cho, Hyun
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.23 no.4
    • /
    • pp.195-200
    • /
    • 2013
  • Novel Sr-Y-Si-Oxynitride yellow phosphors were synthesized and the effect of calcination temperature, reduction temperature and $Eu^{2+}$ concentration on their luminescence properties were studied. Optimal temperature conditions were found to be $1400^{\circ}C$ and $1300^{\circ}C$ for solid-state reaction and reduction, respectively. The synthesized $Ba_9Y_{2+y}Si_6O_{24-3y}N_{3y}:Eu^{2+}$ phosphors showed a single intense broadband emission in the range of 571~587 nm for 450 nm excitation light source. The highest luminescence intensity was obtained with Eu concentration of 3 mol% and concentration quenching was observed beyond 5 mol%. FE-SEM and PSA showed that the synthesized phosphors consists of particles with an average size of ${\sim}8.2{\mu}m$.

Results of the Closed Treatment of Displaced Middle-Third Fractures of The Clavicle (전위된 쇄골간부 골절에서 보존적 치료의 결과)

  • Lee Kwang-Won;Song Dae-Hwa;Ong Sang-Suk;You Soo-Guen;Choy Won-Sik
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.1
    • /
    • pp.83-92
    • /
    • 1998
  • Fractures of the clavicles are extremely common, accounting for 5 to 10% of all injuries in the adult skeletal trauma. Despite this, nonunions and symptomatic malunions after clavicular fracture are uncommon. When these complications occur, however, they may be associated with 11 pattern of disability that includes not only pain but also impairment of upper extremity function. The purpose of this study was to clarify the outcome of clavicular fractures treated by conservatively, and emphasize treatment and factors that possibly predispose a clavicular fracture to poor function or nonunion. We evaluated 9] consecutive fractures of the middle-third of the clavicle in adults which had been treated conservatively. There were 59 males and 33 females ranging in age from 17 to 80 years (average 36.8 years). Nine of the 91 fractures (10%) had developed nonunion, and 4 fractures (4.4%) reported unsatisfactory results. No patients had significant impairment of range of motion or strength as a result of the injury. We found that initial shortening at the fracture of≥20mm(6 cases) had a highly significantly association with nonunion(P<0.0001). Final shortening of 20mm or more (4 cases) was associated with an unsatisfactory result, but not with nonunion(P<0.0001). Our results have led us to recommend the open reduction and internal fixation of severely displaced fractures of the middle third of the clavicle in adults patients.

  • PDF

Luminous Characteristics of Bridge's Nightscape across the Han River (조명물리량 측면에서 본 교량의 야간경관 평가)

  • Hwang, Tae-Yon;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.1
    • /
    • pp.7-18
    • /
    • 2006
  • This study aims to analyze the illumination effects of bridges across the Han River. For the purpose, 8 bridges were selected. Field survey and measurements were performed, and the physical values such as luminance, color temperature and chromaticity were measured by Radiant Imaging Prometric 1400 Color. The results of the study are as follows; (1) Metal halide lamp, sodium lamp and LED(Light Emitting Diode) of various colors, are used in illuminating the bridges and create color contrasts and color changing by color filters. (2) Luminance contrast of the illuminated bridges affects 'modeling' and 'spare sense' of bridges, and it might improve people's preference and impression. (3) Color temperature of the illuminated bridges is influenced by 'color of bridge', 'material of bridge' and, 'color temperature and color of light sources'. (4) 'Structure of bridges' and 'luminaires' influence on the physical feature of the bridges. Especially, illumination of the bridges shows resemblant patterns by 'structure of bridges'.

An Study on Priority Determining for Development Strategies of Plant Factory Using Analytic Hierarchy Process and Likert Scale (식물공장 발전방향 설정을 위한 정책 우선순위 도출)

  • Kim, Yean-Jung;Han, Hye-Sung;Kim, Bae-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5570-5575
    • /
    • 2013
  • This study was carried out to find prioritization and evaluation of importance factor for plant factory development direction. According to the results, experts have put profitability secure at the top of development of plant factory industry. It is urgently needed in economic sector that products from plants factory secure the market and adjust the shipping date through contract cultivation and year-round production. Also, illuminant technology is also important in technology development section and R&D. On the other hand, consumers do not yet fully understand the benefits of the plant factory, and this will lead to continued slow sales. Therefore, the government needs to draw up measures to support producers who cultivated agricultural products from plant factory.

Mechanical Design and Development of a Digital Tongue Imaging System Equipped with LEDs (LED 광원을 이용한 디지털 혀 영상 촬영장치의 기구설계와 개발)

  • Nam, Dong-Hyun;Kim, Ji-Hye;Lee, Sang-Suk
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.3
    • /
    • pp.41-48
    • /
    • 2012
  • Objectives: The aims of this study are to design a optimized mechanical structure of digital tongue imaging system (DTIS) equipped with LEDs in aspects of object distance and camera angle of coverage. Methods and Results: We tried to find optimized object distance while recording a rectangular object of common tongue size. In case object distance is 22 cm or less, edge of the rectangle was not taken beyond the shooting range. In contrast, if object distance is 40 cm or more, the rectangle image was too small. Therefore when considering the variation of subjects, we selected distance of 35-40 cm as appropriate object distance for the DTIS. We also tried to find optimized angle between camera view axis and horizontal line. We photographed from the side of the face of 7 adults with exposed tongue. We drew an exposed tongue lines to connect the tongue tip points and the tongue root points by using the photos acquired from the side faces. And then we calculated the tongue exposure angles between the vertical line and the exposed tongue lines. Mean tongue exposure angle was $28.3^{\circ}$ when tongue was lightly exposed and $13.3^{\circ}$ when maximally. So we determined $73^{\circ}$ as appropriate slope angle of part in contact with face of the DTIS and by considering that the standard variation was great, we designed control gears to adjust the slope of the camera view axis and to regulate the object distance. Conclusions: We designed a optimized mechanical structure in object distance and slope angle of part in contact with face of the DTIS.

Improvement in the Channel Capacity in Visible Light Emitting Diodes using Compressive Sensing (압축센싱기법을 이용한 가시광 무선링크 전송용량 증가기술 연구)

  • Jung, Eui-Suk;Lee, Yong-Tae;Han, Sang-Kook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.6296-6302
    • /
    • 2014
  • A new technique, which can increase the channel bandwidth in an optical wireless orthogonal frequency division multiplexing (OFDM) link based on a light emitting diode (LED), is proposed. The technique uses adaptive sampling to convert an OFDM signal to a sparse waveform. In compressive sensing (CS), a sparse signal that is sampled below the Nyquist/Shannon limit can be reconstructed successively with sufficient measurements. The data rate of the proposed CS-based visible light communication (VLC)-OFDM link increases from 30.72 Mb/s to 51.2 Mb/s showing an error vector magnitude (EVM) of 31 % at the quadrature phase shift keying (QPSK) symbol.