• Title/Summary/Keyword: LDI

Search Result 63, Processing Time 0.029 seconds

자랑스런안전인 - 안전, 작은 욕심이 더 많은 생명을 지킵니다 - STECO 이상천 안전관리자 -

  • Im, Jae-Geun
    • The Safety technology
    • /
    • no.144
    • /
    • pp.14-15
    • /
    • 2009
  • 몸을 움츠리게 하는 차가운 날씨, 아침 일찍부터 두꺼운 외투를 걸치고 길을 나선다. 비가 온 뒤라 초겨울 하늘은 hds통 짙푸른 색으로 구름 한 점 없이 맑다. 충남 천안시 외국인 산업단지내에 위치한 LDI(LCD Drive IC) 제품 Package 전문반도체 회사 스테코, 이곳의 환경안전보건 파트를 책임지고 있는 이상천 안전관리자를 만났다.

  • PDF

H.264 Encoding Technique of Multi-view Image expressed by Layered Depth Image (계층적 깊이 영상으로 표현된 다시점 영상에 대한 H.264 부호화 기술)

  • Kim, Min-Tae;Jee, Inn-Ho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.1
    • /
    • pp.81-90
    • /
    • 2010
  • This paper presents H.264 coding schemes for multi-view video using the concept of layered depth image(LDI) representation and efficient compression technique for LDI. After converting those data to the proposed representation, we encode color, depth, and auxiliary data representing the hierarchical structure, respectively, Two kinds of preprocessing approaches are proposed for multiple color and depth components. In order to compress auxiliary data, we have employed a near lossless coding method. Finally, we have reconstructed the original viewpoints successfully from the decoded approach that is useful for dealing with multiple color and depth data simultaneously.

Mass spectrometry based on nanomaterials (나노물질을 이용한 질량분석 기술 개발동향)

  • Park, Jong-Min;Noh, Joo-Yoon;Kim, Moon-Ju;Pyun, Jae-Chul
    • Ceramist
    • /
    • v.21 no.3
    • /
    • pp.249-269
    • /
    • 2018
  • In conventional MALDI-TOF mass spectrometry, analyte molecules are known to be ionized by mixing with organic matrix molecules. As the organic matrix molecules are made into small fragments, they generate unreproducible mass peaks such that MALDI-TOF mass spectrometry is nearly impossible in the low mass-to-charge (m/z) range (< 1000). Additionally, the dried sample mixed with matrix were made as inhomogeneous crystal on metal plate. When the laser radiation was made on the sample crystal, the amount of generated sample ion was observed to be quite different according to the radiation point. Therefore, the quantitative analysis was very difficult even for the sample spots at the same concentration for the conventional MALDI-TOF mass spectrometry. In this work, we present laser desorption/ionization (LDI) mass spectrometry based on solid-matrices for the quantitative analysis of small molecules in the low m/z range by using MALDI-TOF mass spectrometry: (1) Carbon based nanostructures; (2) Semiconductor based nanomaterials; (3) Metal based nanostructures.

Image-based Surfel Reconstruction by LDI Plane Sweeping (LDI 평면 이동에 의한 이미지 기반 Surfel 복원)

  • Lee, Jung;Kim, Chang-Hun
    • Journal of KIISE:Software and Applications
    • /
    • v.36 no.11
    • /
    • pp.947-954
    • /
    • 2009
  • This paper proposes a novel method that reconstructs a surfel-based object by using visual hull from multiple images. The surfel is a point primitive that effectively approximates point-set surface. We create the surfel representation of an object from images by combining the LDC(Layered Depth Cube) surfel sampling with the concept of visual hull that represents the approximated shape from input images. Because the surfel representation requires relatively smaller memory resources than the polygonal one and its LDC resolution is freely changed, we can control the reconstruction quality of the target object and acquire the maximal quality on the given memory resource.

A Study of Clinical Effect in Kwi-Bi-Tang and Sa-Mul-An-Shin-Tang (귀비탕(歸脾湯) 및 사물안신탕(四物安神湯)의 임상효과(臨床效果)에 관(關)한 연구(硏究))

  • Yu Chang-Yeol;Yu Yeong-Su;Yu Hui-Yeong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.4 no.1
    • /
    • pp.135-153
    • /
    • 1993
  • In order to observe clinical effects of Kwi-Bi-Tang(歸脾湯) and Sa-Mul-An-Shin-Tang(四物安神湯), I reached following conclusion through the physiochemical investigation the following results obtained. 1)In serum Lipid, only Total cholesterol is significantly decresed in medication group of Kwi-Bi-Tang(歸脾湯), but is not in the medicaton of Sa-Mul-An-Tang(四物安神湯). 2). The value of Cardiac enzyme is remarkably decreased in the medication group of Kwi-Bi-Tang(歸脾湯), Only AST is significantly decresed in the medication group of Sa-Mul-An-Tang(四物安神湯). 3) In determination of LDH isoenzyme, LDI is significantly decrease both in the medication group of Kwi-Bi-Tang(歸脾湯) and Sa-Mul-An-Shin-Tang(四物安神湯). Especially, LDI is remarkably decreased in the medication group of Kwi-Bi-Tang(歸脾湯). In view of the results so far achieved, we knew that Kwi-Bi-Tnag(歸脾湯) and Sa-Mul-An-Shin_Tang(四物安神湯) had improved ischemic condition of cardiac muscle, specially, Kwi-Bi-Tnag(歸脾湯) was significant compared to Sa-Mul-An-Shin-Tang(四物安神湯).

  • PDF

A Study on the GIS for The Sea Environmental Management I - Focus on the Study of A Interpolation on The Application of LDI Algorism - (GIS를 활용한 해양환경관리에 관한 연구 I - LDI 알고리즘 적용을 위한 보간법에 관한 연구 -)

  • Lee, Hyoung Min;Park, GI Hark
    • Journal of Environmental Impact Assessment
    • /
    • v.15 no.6
    • /
    • pp.443-452
    • /
    • 2006
  • Today, satellite remote sensing (RS) and geographic information systems (GIS) plays an important role as an advanced science and technology. This study was developed a Line Density Algorithm which was clarify and describe the thermal front by using NOAA SST (sea surface temperature) and GIS spatial analysis for systemic and effective management of fish raising industry and sea environmental pollution by land reclamation program. Before this, a study about a interpolation method was carry out which was very important for estimate the hidden value between a special point. For this study Inverse Distance Weighted interpolation, Spline interpolation, Kriging interpolation methods were choose and SST data from 2001 to 2004 in spring (March, April, May) were analyzed. According to the study Kriging interpolation method was the very adaptive method from a practical point of view and excellent in description and precision then others. Finally, the result of this study will be use for develope the Line Density Index Algorism.

The Improvement of Matching of Amplifier Input Transistor for Display Driver IC (Display Driver IC용 Amplifier Input Transistor의 Matching 개선)

  • Kim, Hyeon-Cheol;Roh, Yong-Han
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.3
    • /
    • pp.213-216
    • /
    • 2008
  • The voltages for pixel electrodes on LCD panels are supplied with analog voltages from LCD Driver ICs (LDIs). The latest LDI developed for large LCD TV's has suffered from the degradation of analog output characteristics (target voltage: AVO and output voltage deviation: dVO). By the failure analysis, humps in $I_D-V_G$ curves have been observed in high voltage (HV) NMOS devices for input transistors in amplifiers. The hump is investigated to be the main cause of the deviation for the driving current in HV NMOS transistors. It also makes the matching between two input transistors worse and consequently aggravates the analog output characteristics. By simply modifying the active layout of HV NMOS transistors, this hump was removed and the analog characteristics (AVO &dVO) were improved significantly. In the help of the improved analog characteristics, it also became possible to reduce the size of the input transistors less than a half of conventional transistors and significantly improve the integration density of LDIs.

Organic matrix-free imaging mass spectrometry

  • Kim, Eunjin;Kim, Jisu;Choi, Inseong;Lee, Jeongwook;Yeo, Woon-Seok
    • BMB Reports
    • /
    • v.53 no.7
    • /
    • pp.349-356
    • /
    • 2020
  • Mass spectrometry (MS) is an ideal tool for analyzing multiple types of (bio)molecular information simultaneously in complex biological systems. In addition, MS provides structural information on targets, and can easily discriminate between true analytes and background. Therefore, imaging mass spectrometry (IMS) enables not only visualization of tissues to give positional information on targets but also allows for molecular analysis of targets by affording the molecular weights. Matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF) MS is particularly effective and is generally used for IMS. However, the requirement for an organic matrix raises several limitations that get in the way of accurate and reliable images and hampers imaging of small molecules such as drugs and their metabolites. To overcome these problems, various organic matrix-free LDI IMS systems have been developed, mostly utilizing nanostructured surfaces and inorganic nanoparticles as an alternative to the organic matrix. This minireview highlights and focuses on the progress in organic matrix-free LDI IMS and briefly discusses the use of other IMS techniques such as desorption electrospray ionization, laser ablation electrospray ionization, and secondary ion mass spectrometry.

Development of a LDI System for the Maskless Exposure Process and Energy Intensity Analysis of Single Laser Beam (Maskless 노광공정을 위한 LDI(Laser Direct Imaging) 시스템 개발 및 단일 레이저 빔 에너지 분포 분석)

  • Lee, Soo-Jin;Kim, Jong-Su;Shin, Bong-Cheol;Kim, Dong-Woo;Cho, Meyong-Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.834-840
    • /
    • 2010
  • Photo lithography process is very important technology to fabricate highly integrated micro patterns with high precision for semiconductor and display industries. Up to now, mask type lithography process has been generally used for this purpose; however, it is not efficient for small quantity and/or frequently changing products. Therefore, in order to obtain higher productivity and lower manufacturing cost, the mask type lithography process should be replaced. In this study, a maskless lithography system using the DMD(Digital Micromirror Device) is developed, and the exposure condition and optical properties are analyzed and simulated for a single beam case. From the proposed experimental conditions, required exposure experiments were preformed, and the results were investigated. As a results, 10${\mu}m$ spots can be generated at optimal focal length.