• Title/Summary/Keyword: LCoS

Search Result 43, Processing Time 0.018 seconds

Electro-optical Characteristics of Full-HD LCOS Depending on the Trench Structure between Adjacent Pixels (Full-HD LCOS의 이웃한 픽셀 사이의 Trench구조 변화에 따른 전기광학적 특성 분석)

  • SonHong, Hong-Bae;Kim, Min-Seok;Kang, Jung-Wwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.2
    • /
    • pp.59-62
    • /
    • 2009
  • In order to check the validation of LC simulation, 0.7 inch LCOS panel in full-HD resolution was fabricated and used for the electro-optical measurement. Compared the measured data with the calculated data, the averaged difference was 1.72% under 0 ~ +6 V bias on pixel electrode. To improve the optical characteristics of full-HD LCOS panel, the planar structure and trench structures (0.1 um, 0.2 um and 0.3 um-in-depth) between adjacent pixels were investigated with LC simulation. The planar structure showed the higher reflectance and faster reflectance-voltage response time than the trench structure. The optical fill factor and contrast ratio of planar structure were also higher than those of trench structures. As compared 1 um-in-depth trench structure resembled to the real structure with the planar structure, the optical fill factor was improved by 1.15% and the contrast ratio was improved by 5.26%. In order to minimize the loss of luminance and contrast ratio, the planar structure need to be applied between adjacent pixels.

  • PDF

Computer Generated Hologram for Beam Control of LCOS based Wavelength Selective Switch (LCOS기반의 파장선택스위치 빔제어용 컴퓨터 생성 홀로그램)

  • Lee, Yong-Min;Han, Chang Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.744-749
    • /
    • 2016
  • This paper presents the design of a computer-generated hologram for beam control of an LCOS-based wavelength selective switch, which is the core technology for next-generation ROADM. By introducing a computer-generated hologram instead of general grating patterns to control the LCOS device, we contribute to building a more efficient wavelength selective switch. With the use of phase modulation properties of LCOS devices, we designed the hologram for five-port output and a 40-channel wavelength selective switch. We applied a multi-level phase modulation technique with the Gerchberg-Saxton algorithm to produce the hologram, which is easily scalable to any different type of wavelength selective switch. With an experimental setup, we verified the usability of the hologram designed for five-port output. We also suggest a hologram design technique for beam control of a 40-channel wavelength selective switch.

Value of Pulmonary Function Test as a Predicting Factor of Pneumothorax in CT-guided Needle Aspiration of the Lung (전산화단층촬영 유도하 경피적 폐침생검시 기흉발생 예측인자로써의 폐기능검사의 가치)

  • Kim, Yeon-Jae;Kim, Chang-Ho;Lee, Yeung-Suk;Park, Jae-Yong;Kang, Duk-Sik;Jung, Tae-Hoon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.3
    • /
    • pp.259-266
    • /
    • 1993
  • Background: To evaluate the risk factor of pneumothorax (PNX) which is the most common complication of CT-guided needle aspiration of the lung, we have examined the frequency of PNX according to the presence of obstructive ventilatory impairment determined by pulmonary function tests. Methods: A comparative study of analysis of forecd expiratory volume and folw-volume curves, and determinations of diffusing capacity taken before procedure were made between each 16 cases with PNX and controls with no PNX. Each of the control group was matched for sex, age, height, and size and depth of lesion with the former. Results: 1) In comparison of vital capacity and parameters derived from forced expiratory volume curve between two groups, VC and FVC were not significantly different, whereas $FEV_1$, $FEV_1$/FVC%, and FEF25-75% showed a significant decrease in the PNX gorup. Also, in the PNX group, all the observed values of parameters analyzed from flow-volune curve were siginificantly reduced in the PNX group compared with those in the control group. 2) The diffusing capacity tended to decrease along with varying individual differences in the PNX group. 3) Patients who had obstructive ventilatory impairment according to the results of pulmonary function tests experienced a twofold increase in the frequency of PNX and a sixfold increase in the frequency of chest tube drainage for treatment of PNX compared with those whose results were normal. Conclusion: These findings suggest that the exact evaluation of obstructive lung disease determined by pulmonary function test be considered assessing a pastient's risk for PNX in the patients who will take the CT-guided needle aspiration of the lung.

  • PDF