• Title/Summary/Keyword: LCP

Search Result 148, Processing Time 0.024 seconds

Crude Protein Requirements for Maintenance of Hanwoo Steers by Protein Balance Trial (단백질 균형시험에 의한 한우 거세우의 유지 조단백질 요구량)

  • 김경훈;오영균;이상철;신기준;강수원;문여황;송만강
    • Journal of Animal Science and Technology
    • /
    • v.48 no.4
    • /
    • pp.533-540
    • /
    • 2006
  • This experiment was conducted to determine crude protein requirements for maintenance (CPm) of growing Hanwoo steers. Eighteen Hanwoo steers (173.7kg) were allocated randomly to diets with three levels of crude protein in the concentrate by replacing ground corn with corn gluten meal: 0% (LCP), 7.2% (MCP) and 14.2% (HCP), respectively. Hanwoo steers in each treatment were fed diets containing rice straw (20%) and concentrates (80%). CP intake was 5.5, 7.8 and 10.7g/BW0.75 for LCP, MCP and HCP, respectively. Protein balance was -0.05, 2.36 and 4.07g/BW0.75 for LCP, MCP and HCP, respectively. Intercept of the regression equation between CP intake and retained CP indicated that CPm was 5.56g/BW0.75. The estimate of CPm adopted by Korean Feeding Standard (2002) was almost 20% higher than that adopted by Japanese Feeding Standard for Beef Cattle (2000); this would need to be verified with more feeding trial data set including protein requirements for growth.

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.

Operative Treatment with Locking Compression Plate (LCP) in Proximal Humerus Fracture (잠김 압박 금속판을 이용한 상완골 근위부 골절의 치료)

  • Ha, Sung-Sik;Kim, Jae-Young;Hong, Ki-Do;Sim, Jae-Chun;Kang, Jung-Ho;Park, Kwang-Hee
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.137-142
    • /
    • 2008
  • Purpose: To evaluate the clinical and radiographic results of the treatment of a proximal humerus fracture with a locking compression plate(LCP). Materials and Methods: This study reviewed the results of 24 cases of a proximal humerus fracture treated with a LCP from January 2005 to April 2007, after a follow up of more than 12 months. There were 8 males and 16 females with a mean age of 68.9(33-90) years. The clinical results were evaluated using the Neer's evaluation criteria, and the radiographic results were evaluated using the bone union time and Paavoleinen method. Results: The mean time for bone union was 11.9 weeks. Using the Neer's functional evaluation, 21 cases of the 24 patients (87%) showed excellent or satisfactory results. Twenty two cases (91%) showed good results according to the Paavoleinen method. The complications encountered were metal failure (1 patient), AVN of the humeral head (1 patient) and joint stiffness (1 patient). Conclusion: The LCP demonstrated good results in the treatment of a proximal humerus fracture and has relatively fewer complications than other internal fixators.

Effects of Screw Configuration on Biomechanical Stability during Extra-articular Complex Fracture Fixation of the Distal Femur Treated with Locking Compression Plate (잠김 금속판(LCP-DF)을 이용한 대퇴골 원위부의 관절외 복합골절 치료시 나사못 배열에 따른 생체역학적 안정성 분석)

  • Kwon, Gyeong-Je;Jo, Myoung-Lae;Oh, Jong-Keon;Lee, Sung-Jae
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.3
    • /
    • pp.199-209
    • /
    • 2010
  • The locking compression plates-distal femur(LCP-DF) are being widely used for surgical management of the extra-articular complex fractures of the distal femur. They feature locking mechanism between the screws and the screw holes of the plate to provide stronger fixation force with less number of screws than conventional compression bone plate. However, their biomechanical efficacies are not fully understood, especially regarding the number of the screws inserted and their optimal configurations. In this study, we investigated effects of various screw configurations in the shaft and the condylar regions of the femur in relation to structural stability of LCP-DF system. For this purpose, a baseline 3-D finite element (FE) model of the femur was constructed from CT-scan images of a normal healthy male and was validated. The extra-articular complex fracture of the distal femur was made with a 4-cm defect. Surgical reduction with LCP-DF and bone screws were added laterally. To simulate various cases of post-op screw configurations, screws were inserted in the shaft (3~5 screws) and the condylar (4~6 screws) regions. Particular attention was paid at the shaft region where screws were inserted either in clustered or evenly-spaced fashion. Tied-contact conditions were assigned at the bone screws-plate whereas general contact condition was assumed at the interfaces between LCP-DF and bone screws. Axial compressive load of 1,610N(2.3 BW) was applied on the femoral head to reflect joint reaction force. An average of 5% increase in stiffness was found with increase in screw numbers (from 4 to 6) in the condylar region, as compared to negligible increase (less than 1%) at the shaft regardless of the number of screws inserted or its distribution, whether clustered or evenly-spaced. At the condylar region, screw insertion at the holes near the fracture interface and posterior locations contributed greater increase in stiffness (9~13%) than any other locations. Our results suggested that the screw insertion at the condylar region can be more effective than at the shaft during surgical treatment of fracture of the distal femur with LCP-DF. In addition, screw insertion at the holes close to the fracture interface should be accompanied to ensure better fracture healing.

Green network analysis in coastal cities using least-cost path analysis: a study of Jakarta, Indonesia

  • Kim, Jae-Eun
    • Journal of Ecology and Environment
    • /
    • v.35 no.2
    • /
    • pp.141-147
    • /
    • 2012
  • The rapid urbanization in developing countries is accelerating both the depletion and fragmentation of urban green space, despite the known positive effects of green spaces on the environmental conditions in cities and the quality of life of residents. Consequently, there is a need for practical tools that can support the development of networks of urban green spaces. This article presents a study that used a GIS-based least cost path (LCP) analysis to identify the best alternative for developing an urban green space network in the coastal city of Jakarta, Indonesia, which was based on the evaluation of topography and land use characteristics. Pair-wise analysis was used to reduce the sensitivity in the LCP model. The results showed that the coastal wetlands in the northern part of Jakarta and the agricultural fields in the suburban areas of Jakarta play an important role in connecting the green space network. On the other hand, some green spaces in the central part of Jakarta could not be connected by the LCP model. The method used in this study can serve as a tool to support the identification of networks of potential urban green spaces. It can also provide useful information for sustainable urban landscape planning and management in urban ecosystems. However, the inclusion of socio-economic criteria would further improve the model.

Dielectric and Mechanical Properties of BNT-LCP Composites

  • Park, Myoung-Sung;Cho, Jeong-Ho;Kim, Byung-Ik;Chun, Myoung-Pyo;Nahm, Sahn
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.547-553
    • /
    • 2011
  • We investigated the dielectric and mechanical properties of ceramic polymer composite xBNT - (1-x)LCP (x= 0, 10, 20, 30, 40 vol.%). The disk shaped BNT ($BaNd_2Ti_4O_{12}$) - LCP (liquid crystal polymer) composite samples were prepared by compression molding method. With increasing the BNT content in composites from 10 to 40 vol.%, the dielectric constant increased but the dielectric loss as well as bending strength of composites reduced. These composites were well described with modified Lichtenecker's model having k = 0.392 and 0.303 for the first and second ball milled BNT filled composites, which means that the BNT filler in composites are well dispersed. The dielectric constant of the composite comprised of the second milled BNT ($D_{50}$ = 1.39 um) was higher that of the composite of the first milled BNT ($D_{50}$= 2.45 um), which seems to be related with the different particle size and dispersion of BNT fillers in LCP matrix. The bending strength of the composite containing the second milled BNT was superior to that of the composite of the first milled BNT.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Microstructural Morphology and Bending Performance Evaluation of Molded Microcomposites of Thermotropic LCP and PA6 (액정폴리머/폴리아미드6 미시복합재료의 내부구조 및 기계적 굽힘성능 평가)

  • ;Kiyoshi Takahashi
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.53-64
    • /
    • 1999
  • Microstructural morphology and bending strengths of moulded composites of thermotropic liquid crystalline polymer(LCP) and polyamide 6 (PA6) have been studied as a function of epoxy fraction. Injection-moulding of a composite plaque at a temperature below the melting point of the LCP fibrils generated a multi-layered structure: the surface skin layer with thickness of $65\;-\;120{\mu\textrm{m}}$ exhibiting a transverse orientation; the sub-skin layer with an orientation in the flow direction; the core layer with arc-curved flow patterns. The plaques containing epoxy 4.8vol% exhibited superior bending strength and large fracture strain. With an increase of epoxy fraction equal to and beyond 4.8vol%, geometry of LCP domains was changed from fibrillar shape to lamella-like one, which caused a shear-mode fracture. An analysis of the bending strength of the composite plaques by using a symmetric layered model beam suggested that addition of epoxy component altered not only the microstructural geometry but also the elastic moduli and strengths of the respective layers.

  • PDF

Determination of Crude Protein Requirements for Maintenance of Prepubertal Hanwoo Heifers (한우 암송아지의 성성숙 전 유지 단백질 요구량 결정)

  • Nam, In-Sik;Oh, Young-Kyoon;Jang, Sun-Sik;Kim, Do-Hyung;Seol, Yong-Joo;Kim, Kyoung-Hoon
    • Journal of Animal Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.171-176
    • /
    • 2011
  • Two trials at different body weights of Hanwoo heifers (average body weight of 143 and 257 kg, respectively) were conducted to determine crude protein requirements for maintenance (CPm). Six Hanwoo heifers in each trial were used in two 3 ${\times}$ 3 Latin square design with three diets containing three levels of CP, 14 days in each period. In trial 1, the diets were based on 2.8 kg fresh wt./day/heifer timothy hay (LCP) with supplements of either 250 g ground corn and 150 g corn gluten meal (MCP) or 500 g ground corn and 300 g corn gluten meal (HCP). In trial 2, the diets were based on 4.8 kg fresh wt./day/heifer timothy hay (LCP) with supplements of either 350 g ground corn and 250 g corn gluten meal (MCP) or 700 g ground corn and 500 g corn gluten meal (HCP). In trial 1, CP intakes were 236.6, 340.1, and 459.8 g/d for LCP, MCP, and HCP, respectively. Crude protein balances were 0.51, 1.87 and 3.20g/$BW^{0.75}$/d for LCP, MCP, and HCP, respectively. In trial 2, CP intakes were 415.2, 606.9 and 793.0g/d for LCP, MCP and HCP, respectively. Crude protein balances were 0.67, 1.03, 2.99 g/$BW^{0.75}$/d for LCP, MCP, and HCP, respectively. The maintenance requirements for CP from the regression equation between CP intake and CP balance were 4.58g/$BW^{0.75}$/d (trial 1) and 5.02 g/$BW^{0.75}$/d (trial 2) and lower than the value (5.56 g/$BW^{0.75}$/d) adopted by Korean Feeding Standards for Hanwoo (2007).