• Title/Summary/Keyword: LCL Filter

Search Result 146, Processing Time 0.034 seconds

A Capacitance Estimation of Film Capacitors in an LCL-Filter of Grid-Connected PWM Converters

  • Heo, Hong-Jun;Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.13 no.1
    • /
    • pp.94-103
    • /
    • 2013
  • A capacitor deterioration of LCL-filter grid-connected PWM converters is progressed by the self-healing mechanism. It leads to the degradation of the filter performance and drop of power factor. Thus, it is required to diagnose fault-point of capacitors and determine the replacement time. Typically, the fault of capacitors is determined when the capacitance is reduced up to 80% from initial value. This paper proposes algorithm to the determine capacitor replacement time of an LCL filter. The algorithm takes the advantage of change of the response on the injected resonant frequency corresponding to 80% value from the initial capacitance. The results of the algorithm are demonstrated through simulations and experiments.

LCL Filter Design for Grid-connected PCS Using Total Harmonic Distortion and Ripple Attenuation Factor (총고조파 왜율과 리플 감쇄율을 이용한 계통연계형 PCS용 LCL 필터 설계)

  • Park, Jong-Hyoung;Chi, Min-Hun;Kim, Heung-Geun;Chun, Tae-Won;Nho, Eui-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.235-243
    • /
    • 2010
  • This paper describes a design method of LCL filter for grid-connected three-phase PWM inverter. First, by analyzing the ripple component of phase voltages and currents according to the PWM pattern of grid-connected three-phase inverter, the RMS value of the current ripple can be calculated. Then based on the analysis, the current THD in the inverter-side can be defined. After that by analyzing the dependency between the current THD of the system and the current ripple attenuation, the parameter of LCL filter can be designed. Finally, the described LCL filter design method is verified by showing a good agreement between the target current $THD_g$ and the actual one through the simulation and experiment.

Performance Improvement of a Grid-connected PWM Inverter using a Power Theory (전력 이론을 이용한 계통연계 PWM 인버터 시스템의 성능 개선)

  • Jung, Hea-Gwang;Lee, Kyo-Beum;Kang, Sin-Il;Lee, Hyen-Young;Kwon, Oh-Joeng;Song, Seung-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.4
    • /
    • pp.319-327
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations and experiments.

Dual-Loop Power Control for Single-Phase Grid-Connected Converters with LCL Filter

  • Peng, Shuangjian;Luo, An;Chen, Yandong;Lv, Zhipeng
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.456-463
    • /
    • 2011
  • Grid-connected converters have widely adopted LCL filters to acquire high harmonic suppression. However, the LCL filter increases the system order so that the design of the system stability would be complicated. Recently, sole-loop control strategies have been used for grid-connected converters with L or LC filters. But if the sole-loop control is directly transplanted to grid-connected converters with LCL filters, the systems may be unstable. This paper presents a novel dual-loop power control strategy composed of a power outer loop and a current inner loop. The outer loop regulates the grid-connected power. The inner loop improves the system stability margin and suppresses the resonant peak caused by the LCL filter. To obtain the control variables, a single-phase current detection is proposed based on PQ theory. The system transfer function is derived in detail and the influence of control gains on the system stability is analyzed with the root locus. Simulation and experimental results demonstrate the feasibility of the proposed control.

Current Controller Design of the Grid Connected Inverter for the Solar PCS with LCL Filter (LCL 필터를 사용하는 태양광 PCS용 계통 연계형 인버터의 전류 제어기 설계)

  • Park, Kwon-Sik;Jo, Kwang-Rae;Nho, Eui-Cheol
    • Proceedings of the KIPE Conference
    • /
    • 2018.11a
    • /
    • pp.149-150
    • /
    • 2018
  • 본 논문은 LCL 필터를 사용하는 계통 연계형 인버터의 제어기 설계에 대해서 제안한다. 계통 전류를 제어할 경우 댐핑 기법 없이 시스템이 안정할 수 있는 범위가 넓다. LCL 필터의 공진 주파수와 샘플링 주파수에 따라 시스템은 안정 영역과 불안정 영역으로 나눌 수 있다. LPF(Low Pass Filter)를 사용하는 경우 불안정 영역을 줄일 수 있다. 불안정 영역에서 LPF를 사용한 시스템의 안정성을 유지할 수 있는 전류 제어기 설계기법을 제안하고 시뮬레이션을 통해 타당성을 검증하였다.

  • PDF

Design Methodology of Passive Damped LCL Filter Using Current Controller for Grid-Connected Three-Phase Voltage-Source Inverters

  • Lee, Jun-Young;Cho, Young-Pyo;Kim, Ho-Sung;Jung, Jee-Hoon
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1178-1189
    • /
    • 2018
  • In grid-connected voltage-source inverters (VSIs), when compared with a simple inductive L filter, the LCL filter has a better performance in attenuating the high frequency harmonics caused by the pulse-width modulation of power switches. However, the resonance peaks generated by the filter inductors and capacitors can make a system unstable. In terms of simplicity and filter design cost, a passive damping method is generally preferred. However, its high power loss and degradation in high frequency harmonic attenuation are significant demerits. In this paper, a mathematical design solution for a passive LCL filter to derive filter parameters suppressing the high frequency current harmonics to 0.3% is proposed. The minimum filter inductance can be obtained to reduce the size of the filter. Furthermore, a minimum damping resistance design considering a current controller is analyzed for a stable closed-loop system. The proposed design method is verified by experimental results using a 5-kW three-phase prototype inverter.

Non-iterative Optimal Filter Parameter Design Method for LCL Filter-Based Three-Phase Grid-Tied Inverter (LCL 필터 기반의 3상 계통 연계형 인버터를 위한 비반복적 최적 필터 파라미터 설계 방법)

  • Kim, Hyeon-Sik;Sul, Seung-Ki;Lim, Changjin
    • Proceedings of the KIPE Conference
    • /
    • 2016.11a
    • /
    • pp.11-12
    • /
    • 2016
  • 기존 LCL 필터 설계 방법의 경우, 시뮬레이션에 기반한 반복 과정을 통해 필터 파라미터를 최적화므로 많은 시간이 소요된다. 하지만 본 논문에서는 3상 PWM 인버터와 LCL 필터 분석을 통해 설계 시 고려 사항을 단순화할 수 있다. 또한 LCL 필터의 다양한 제약 조건을 파악하고, 이러한 조건 하에서 제작 비용을 최소화할 수 있는 해석 해(analytical solution)를 도출한다. 결과적으로 제안된 단계적(step-by-step) 설계 방법을 통해 빠른 시간내에 최적화된 LCL 필터를 선정할 수 있다. 제안된 방법의 유효성은 시뮬레이션을 통해 최종 검증하였다.

  • PDF

An active damping method of a grid-connected PWM Inverter using an instantaneous power theory (순시전력이론을 통한 계통연계 PWM 인버터 시스템의 능동댐핑 기법)

  • Jung, Hea-Gwang;Lee, Kyo-Beum;Kang, Sin-Il;Lee, Hyen-Young;Kwon, Oh-Joeng;Song, Seung-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.85-87
    • /
    • 2008
  • The demand of a three phase PWM inverter for the purpose of power control or grid-connecting is increasing. This inverter is connected to a grid through an L-filter or LCL-filter to reduce the harmonics caused by switching. An LCL-filter can reduce the harmonic of a low switching frequency and generate a satisfactory level of grid side current with a relatively low-inductance than an L-filter. But the additional poles caused by the LC part affects a stability problem due to induced resonance of the system. This paper presents a compensation method using a power theory to improve performance, the designed LCL-filter system and to reduce the stability problems caused by resonance. The effectiveness of the proposed algorithm is verified by simulations.

  • PDF

New Design Approach for Grid-Current-Based Active Damping of LCL Filter Resonance in Grid-Connected Converters

  • Gaafar, Mahmoud A.;Dousoky, Gamal M.;Ahmed, Emad M.;Shoyama, Masahito;Orabi, Mohamed
    • Journal of Power Electronics
    • /
    • v.18 no.4
    • /
    • pp.1165-1177
    • /
    • 2018
  • This paper investigates the active damping of grid-connected LCL filter resonance using high-pass filter (HPF) of the grid current. An expression for such HPF is derived in terms of the filter components. This expression facilitates a general study of the actively damped filter behavior in the discrete time domain. Limits for the HPF parameters are derived to avoid the excitation of unstable open loop poles since such excitation can reduce both the damping performance and the system robustness. Based on this study, straightforward co-design steps for the active damping loop along with the fundamental current regulator are proposed. A numerical example along with simulation and experimental results are presented to verify the theoretical analyses.

Optimized Topology and LCL Filter Design of Utility-interactive PCS for MCFC Generation (MCFC 발전을 위한 계통연계 PCS의 최적 토폴로지 및 LCL 필터 설계)

  • Kim, Hyung-Jin;Park, Jun-Sung;Kim, Young-Woo;Choi, Se-Wan;Kim, Tae-Hee;Lee, Gi-Pung;Lee, Tae-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.405-414
    • /
    • 2011
  • Recently, the development of several hundreds of kW scale PCS for fuel cell generation is required as commercialization process of distributed generation systems using high temperature fuel cells such as MCFC begins. This paper proposes and optimized topology suitable for MCFC fuel cell generation system and LCL filter design method considering voltage quality of local loads such as MBOP. An interleaving technique is applied to step-up DC-DC converter, optimized number of phases is determined considering efficiency and volume. Also, a LCL filter design method is proposed considering quality of current injected to the grid as well as that of voltage across the local load. The proposed PCS system is validated through reduced 1kW prototype.