• 제목/요약/키워드: LCL Filter

검색결과 146건 처리시간 0.028초

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

고조파 저감 능력을 가진 직류전철 회생인버터 시스템 (Regeneration Inverter System for DC Traction with Hormonic Reduction Capability)

  • 원충연;장수진;김용기;방효진;송상훈;안규복
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.96-104
    • /
    • 2004
  • 본 논문에서는 전철시스템의 변전소에서 직류모선에 발생하는 잉여분의 직류전력을 교류전원 측으로 회생시킬 수 있는 직류전력 회생시스템을 제안한다. 제안된 직류 전철용 회생인버터 시스템은 인버터와 능동전력필터로 사용할 수 있다. 회생인버터 모드에서는 전철의 감속에 의해 회생되는 에너지를 재사용 할 수 있으며, 능동전력필터 모드에서는 변전소의 정류기에 의해 발생되는 고조파 왜곡을 보상하기 위해 사용할 수 있다. 전력용량과 스위칭 손실을 고려하여 시스템은 3상 PWM 인버터를 기반으로 설계되며 병렬인버터, 출력변압기와LCL필터로 구성된다.

LCL필터를 가진 3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 전향보상기법 (An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters with LCL Filter)

  • 박병준;최기영;김래영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.214-215
    • /
    • 2013
  • 본 논문은 계통 연계형 인버터 제어에 있어서 계통 임피던스에 의한 계통전압 왜곡을 분석하고 있다. 특히 계통 연계형 인버터의 설계단계에서는 고려되지 않지만, 실제 시스템 구현 시에는 일반적으로 널리 사용되는 저주파트랜스의 누설 인덕턴스에 의한 영향을 살펴보았다. 계통 임피던스에 의해 계통 전압의 왜곡이 발생하고 이로 인해 저차 고조파 성분의 전류가 계통으로 유입되게 되는데, 본 논문에서는 이 저차 고조파에 대해 분석하고, 이를 감쇄시키는 기법을 소개한다. 제안하는 방법은 1.5kW 전압형 인버터의 시물레이션을 통해 검증하였다.

  • PDF

저가형 하이브리드 계통 연계 필터의 구성 (Configuration of low-cost hybrid grid-connected filter)

  • 김정훈;김효선;왕지명;정대원;양승학;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.76-77
    • /
    • 2013
  • 최근 풍력발전등의 분산전원 설치가 많아짐에 따라 계통연계 인터페이스 필터에 대한 연구가 활발히 진행되고 있다. 이러한 인터페이스 필터는 LCL 필터인 경우가 대다수인데 그 제작과 설치 비용이 만만치않음이 현실이다. 그 중 코어와 코일의 복합체인 인덕터의 설치에 노력과 비용이 가장 크게 들어간다고 볼 수 있다. 본 논문은 최근의 하이브리드 타입의 코어에 착안하여 인덕터 설계에 있어서 페라이트/더스트코어 혹은 하이브리드타입 코어를 인입쪽의 인덕터(L1)요소로 하고 계통 인출쪽 인덕터(L2)를 규소강판으로 하는 혼합형 LCL 필터를 제안한다. 인입쪽의 L1C필터는 LPF로 작동하므로 L2를 저주파수용 규소강판으로 설계하여 결과적으로 비용을 저감함이 본 논문의 초점이다. 그 효과는 선형 재질을 사용한 PSIM 시스템 시뮬레이터를 활용하여 검증한다.

  • PDF

Observer-based Voltage Sensorless Control Scheme for an LCL-filtered Grid-connected Inverter

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2017년도 전력전자학술대회
    • /
    • pp.266-267
    • /
    • 2017
  • To synchronize the distributed generation (DG) unit with the grid, the voltage sensors are generally employed to obtain the grid phase angle. This paper presents an observer-based voltage sensorless control scheme for a three-phase inverter connected to the grid through an LCL filter. The proposed control scheme consists of an augmented state observer and a feedback controller. The augmented state observer is used to estimate the grid voltages and states of the inverter system, which are then employed to determine the grid voltage angle and to construct the feedback controller. As a result of using the observer, only the grid current sensors are required to accomplish the control scheme. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF

계통 연계형 단상 멀티레벨 컨버터의 고조파 전류 저감을 위한 필터에 관한 연구 (A basic study on the filter to reduce harmornic current of grid connected single phase multi-level converter)

  • 한상협;김흥근;차헌녕;전태원;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.182-183
    • /
    • 2016
  • 계통 연계형 인버터에서는 고조파 전류를 저감하기 위하여 필터가 필요하다. 이러한 고조파 저감을 위하여 LCL 필터나 LCL 필터의 커패시터 단에 직렬로 L을 추가한 직렬 공진을 이용한 LLCL 필터가 있다. 이러한 필터들은 특정 주파수 대역의 고조파를 효과적으로 제거할 수 있으며 기존의 L 필터보다 용량이 줄어든다. 본 논문에서는 단상 멀티 레벨 컨버터의 PWM 주파수 성분의 고조파 저감 효과를 갖는 L, LLCL 필터를 설계하고 비교한다.

  • PDF

Controller Design for a Quick Charger System Suitable for Electric Vehicles

  • Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권5호
    • /
    • pp.1122-1130
    • /
    • 2013
  • This paper proposes a new design for quick battery charger systems for electric vehicles that consists of a three-phase inverter and a full-bridge converter which use the phase-shift method. The 3-phase inverter controls the input and DC-link voltage by use of a current controller and a voltage controller. The full-bridge converter transfers the DC-link voltage to a fixed output voltage. Designs for the output-side converter and controller for improved performance are proposed in this paper. Design schemes for the filter and controller of an input-side inverter are also presented. Furthermore, the paper proposes a compensation method for the offset current that is caused by switch failure and circuit problems. Simulations and experiments have been performed on a 50kW-battery charger system that is suitable for vehicles. The presented results verify the validity of the proposed method and the superiority of the system over conventional methods.

A 15kW Grid-Connected Battery Charging and Discharging System with AC Regeneration Function

  • Youn, Sun-Jae;Kim, Jun-Gu;Kim, Jae-Hyung;Won, Chung-Yuen;Na, Jong-Kuk
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2011년도 전력전자학술대회
    • /
    • pp.491-493
    • /
    • 2011
  • In this paper, a 15kW grid-connected battery charging and discharging system was proposed. AC regenerative device which consisted of an inverter using IGBTs and LCL filter transferred surplus power to grid. Phase locked loop(PLL) was used to resolve three-phase unbalance. AC regeneration function is able to improve the rate of energy use and the cost savings of energy is expected.

  • PDF

Comparison of Different Methods for Line Impedance Estimation

  • 알레미파얌;서보환;이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.454-455
    • /
    • 2010
  • This paper surveys recent works in line impedance estimation. Inverters used in distribution system are often connected to the grid through LCL filter. Different methods are investigated for estimating the line impedance. Advantages and disadvantages with brief summary for each method are presented. Simulation results for a specified grid are shown for two main different methods and the results are compared with estimation error.

  • PDF

연속적인 운전모드의 전환을 위한 계통연계형 인버터의 간접 전류 제어기법 (Indirect Current Control of Utility Interactive Inverter for Seamless Transfer)

  • 유태식;배영상;김효성;최세완
    • 전력전자학회논문지
    • /
    • 제11권1호
    • /
    • pp.72-78
    • /
    • 2006
  • 분산발전시스템에 비상부하 등의 전용부하가 접속되어 있는 경우, 주전원에 고장이 발생하러라도 비상전용부하에는 지속적인 전력을 공급하기 위하여 의도적인 단독운전을 하게 된다. 기존의 계통연계형 인버터는 주전원에 전력을 주입하기 위하여 평소에 전류제어모드로 운전을 하기 때문에, 의도적인 단독운전 상황이 발생하는 경우 비상부하에 안정된 전압을 공급해 주기 위하여 전압제어모드로 운전을 전환하여야한다. 이러한 운전모드의 전환시 인버터의 출력단 전압에 심각한 과도문제가 발생된다. 본 논문에서는 의도적인 단독운전 발생시 인버터 운전모드 전환에 따른 출력전압의 과도현상을 최소화하기 위한 인버터 토폴로지와 제어알고리즘을 제안한다. 제안된 간접전류제어 알고리즘에 적합한 LCL필터 설계방법과 설계데이터를 제시한다.