• Title/Summary/Keyword: LC Resonance

Search Result 157, Processing Time 0.024 seconds

Analysis of Parameter Characteristic of Parallel Electrodes Conduction-cooled Film Capacitor for HF-LC Resonance (고주파 LC 공진을 위한 병렬전극 전도냉각 필름커패시터의 파라메타 특성 분석)

  • Won, Seo-Yeon;Lee, Kyeong-Jin;Kim, Hie-Sik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.155-166
    • /
    • 2016
  • It is important to configure capacitance(C) of the capacitor and the induction coefficient(L) of the work coil on the resonant circuit design stage in order to induce heating on the object by a precise and constant frequency components in the electromagnetic induction heating equipment. Work coil conducts a direct induction heating according to heating point and area of the object which has a fixed heat factor so that work coil is designed to has fixed value. On the other hands, Capacitor should be designed to be changed in order to be the higher the utilization of the entire equipment. It is extracted the samples by variation of single electrode capacity from the selection stage of raw materials for capacity to the stage of process design for output of the high frequency LC resonance of 700kHz on 1000 VAC maximum voltage and current to $200I_{MAX}$. It is suggested fundamental experiment results in order to prove relation for the optimal design of HF-LC resonance conduction-cooled capacitor based on the response of frequency characteristics and results of output parameters according to variation of the capacitance size.

New Classes of LC Resonators for Magnetic Sensor Device Using a Glass-Coated Amorphous CO83.2B3.3Si5.9Mn7.6 Microwire

  • Kim, Yong-Seok;Yu, Seong-Cho;Hwang, Myung-Joo;Lee, Hee-Bok
    • Journal of Magnetics
    • /
    • v.10 no.3
    • /
    • pp.122-127
    • /
    • 2005
  • New classes of LC resonators for micro magnetic sensor device were proposed and fabricated. The first type LC resonator (Type I) consists of a small piece of microwire and two cylindrical electrodes at the end of the microwire without direct contact to its ferromagnetic core. In type I resonator the ferromagnetic core of the microwire and cylindrical electrodes act as an inductor and two capacitors respectively to form a LC circuit. The second type LC resonator (Type II) consists of a solenoidal micro-inductor with a bundle of soft magnetic microwires as a core. The solenoidal micro-inductors fabricated by MEMS technique were $500\sim1,000\;\mu{m}$ in length with $10\sim20$ turns. A capacitor is connected in parallel to the micro-inductor to form a LC circuit. A tiny glass coated $CO_{83.2}B_{3.3}Si_{5.9}Mn_{7.6}$ microwire was fabricated by a glass-coated melt spinning technique. A supergiant magneto-impedance effect was found in a type I resonator as much as 400,000% by precise tuning frequency at around 518.51 MHz. In type II resonator the changes of inductance as a function of external magnetic field in micro-inductors with properly annealed microwire cores were varied as much as 370%. The phase angle between current and voltage was also strongly dependent on the magnetic field. The drastic increments of magnetoimpedance at near the resonance frequency were observed in both types of LC resonators. Accordingly, the sudden change of the phase angle, as large as $180^{\circ}C$, evidenced the occurrence of the resonance at a given external magnetic field.

Liquid Chromatography-Solid Phase Extraction-NMR (LC-SPE-NMR) Analysis of Liquid Crystalline Mixtures

  • Park, Gregory Hyung-Jin;Park, Ae-Na;Rho, Kyung-Rae;Shin, Jong-Ho;Kim, Yeong-Jeon;Jo, Sung-Chan;Oh, Weon-Sik
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.15 no.1
    • /
    • pp.14-24
    • /
    • 2011
  • We have performed Liquid Chromatography-Solid Phase Extraction-NMR (LC-SPE-NMR) analysis for liquid crystalline mixture and elucidated the structures of selected components by NMR spectra. Combining the results of one-dimensional 1H experiments as well as homonuclear and heteronuclear two-dimensional experiments, we could analyze the molecular structure of the liquid crystal singles whose structure had not been interpretable by mass spectrometry alone.

The Development of Chestpiece Detecting Techniques for Physical Assessment Trainer (청진 훈련 모형용 청음판 검출 알고리즘 개발)

  • Chang, In Bae;Oh, Soo Hwan;Lee, Young Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.6
    • /
    • pp.527-534
    • /
    • 2014
  • The control system of human torso model and driving system of stethoscope for physical assessment trainer are developed. The detecting characteristics of circular pickup coil which is driven by square wave voltage signal with resonance frequency of LC circuits are investigated and it is confirmed that the pickup coil can detect the existence of chestpiece near the coil region. The control system of human torso model is composed of 8 channel pickup coils, Mp3 and Bluetooth module. The driving system of stethoscope is composed of chestpiece with contact switch and Bluetooth headset. The chestpiece detecting algorithm check the contact of chestpiece with human body model first and excite the pickup coil sequentially to find the location. The proposed system can be applied the physical assessment trainer.

Computation of Ld, Lq parameters of IPMSM by LC Generate Resonance Method (LC 발전 공진법을 이용한 매입형 영구자석 동기 전동기의 파라미터 계산)

  • Jang, Ik-Sang;Kim, Seung-Joo;Jin, Chang-Sung;Lee, Ju
    • Proceedings of the KIEE Conference
    • /
    • 2009.04b
    • /
    • pp.18-20
    • /
    • 2009
  • Interior Permanent Magnet Synchronous Motor (IPMSM) produces two kind of torque that Magnetic and Reluctance torque. The permanent magnet linkage flux $\Psi_a$ and d-axis and q-axis inductances have an important influence on the torque characteristic of IPMSM. Thus their accurate prediction is essential for predicting performance aspect such as the torque and flux-weakening capabilities. In this paper, $L_d,\;L_q$ is calculated by LC resonance method with FEM. The results are validated by comparison the $L_d,\;L_q$ calculated by another method.

  • PDF

Sensitivity of non-contact Temperature Measurement Using Temperature Sensitive Ferrite (감온 페라이트를 이용한 비접촉 온도측정시스템의 감도특성)

  • Shin, K.H.;Kim, Y.H.
    • Journal of the Korean Magnetics Society
    • /
    • v.14 no.1
    • /
    • pp.1-6
    • /
    • 2004
  • To construct the non-contact temperature detection systems, LC resonance type sensors composed of temperature sensitive ferrite inductors and capacitors were used, and their wireless temperature detection performances were investigated. The temperature was wirelessly detectable using the fabricated LC resonance sensors with a transmitter and receiver, because their inductances and resonance frequencies were changed according to the temperature dependance of permeability of the ferrites. The sensitivity of the system was decreased with the distance i between transmitter and receiver as a ratio of the l$^6$.

Non-Contact Current Sensor Fabricated with LC Resonators (LC 공진소자를 이용한 비접촉 전류센서 연구)

  • Shin, Kwang-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.4
    • /
    • pp.137-141
    • /
    • 2016
  • There is a growing demand for non-contact current measurements for efficient use of electrical power and energy saving. In this study, I propose a non-contact current sensor using LC resonance by a resonance circuit composed of a sensor coil and 2 coupling coils for enabling a wireless measurement. The inductance of the sensor coil, which could be changed by applied current, causes the change of resonance frequency of the resonance circuit. A pair of magnet was attached to the ferrite core to apply a bias magnetic field that enabled the determination of the current direction. We obtained an output voltage change of 18 V with the current of -3~3 A. But, the output was nonlinear. In order to realize the non-contact current measuring method proposed in the present study, there is a need for a strict investigation of linearity and resolution for the future study.

High Efficiency Soft-Switching Boost Converter Using a Single Switch

  • Kim, Jun-Ho;Jung, Doo-Yong;Park, Sang-Hoon;Won, Chung-Yuen;Jung, Yong-Chae;Lee, Su-Won
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.929-939
    • /
    • 2009
  • This paper presents a new soft-switching boost converter based on the LC resonance and passive clamping technique without additional active switches. The circuit achieves high efficiency and low voltage stress by adopting a soft switching method using LC resonance. This paper gives a mathematical analysis of each mode and a detailed design procedure of the proposed boost converter. First of all, the operational principles are verified through simulation results. Then, according to the design procedure, we designed and built a 1.5[kW] prototype soft switching boost converter. Through the experimental results, we demonstrated the validity and usefulness of the proposed boost converter.

Development of Capacitance Measuring Equipment for Electrostatic Precipitator

  • Kim, Seung-Min;Lee, Sung-Jin;Nam, Jung-Han;Cho, Chang-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.128.2-128
    • /
    • 2001
  • Since pulse energization can improve the performance of Electrostatic Precipitator(ESP) for high resistivity dusts, high voltage micro-pulse generators, 70kV 140usec duration pulses for instance, are commonly developed by LC resonance for most pulse powered ESPs. Consisting of discharge electrodes and collecting electrodes, ESP has its own capacitance like a capacitor. ESP's capacitance affects the LC resonance phenomenon with resonance inductor and capacitor of micro-pulse power supply, engineers should acquire the value of their ESP to design for proper power supply design. In this study, we describe the ESP's capacitance measuring device which has the same topology with our new developed micro-pulse power supply. In this microcontroller based capacitance measuring equipment, ESP's capacitance can be calculated easily through ...

  • PDF

Identification of Xanthium Sibiricum Components using LC-SPE-NMR-MS Hyphenated System

  • Sohn, Ji Soo;Jung, Youngae;Han, Ji Soo;Hwang, Geum-Sook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.22 no.2
    • /
    • pp.26-33
    • /
    • 2018
  • Xanthium sibiricum is used as a traditional folk medicine for the treatment of cancer, fever, headache, nasal sinusitis, and skin pruritus. This study aimed to identify components from Xanthium sibiricum extracts using an SPE-800MHz NMR-MS hyphenated system. The simultaneous acquisition of MS and NMR spectra from the same chromatographic peaks significantly increases the depth of information acquired for the compound and allows the elucidation of structures that would not be possible using MS or NMR data alone. LC -NMR analysis was conducted using a HPLC separation system coupled to 800 MHz spectrometer equipped with a cryoprobe, and a SPE unit was used to automatically trap chromatographic peaks using a HPLC pump. LC-MS analysis was conducted with a Q-TOF MS instrument using ESI ionization in the negative ion mode. Using the hyphenated analysis, several secondary metabolites were identified, such as 3',5'-O-dicaffeoylquinic acid, 1',5'-O-dicaffeoyl- quinic acid, and ethyl caffeate. These results demonstrate that the SPE-800MHz NMR-MS hyphenated system can be used to identify metabolites within natural products that have complex mixtures.