• Title/Summary/Keyword: LC/MS analysis

Search Result 764, Processing Time 0.031 seconds

Quality Characteristics of Dolsan Leaf Mustard according to Various Blanching Conditions and Liquid Chromatography with Photodiode Array and Tandem Mass Spectrometry Analysis (다양한 데침조건에서 돌산갓의 이화학적 특성 및 LC-PDA/MS/MS 분석)

  • Son, Hae-Reon;Oh, Sun-Kyung;Tsukamoto, Chigen;Choi, Myeong-Rak
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.20-26
    • /
    • 2016
  • This study aims to examine the optimum blanching conditions as a pretreatment condition to improve the storage stability of Dolsan leaf mustard pickle. The effects of the blan- ching temperature and time were investigated at a temperature range of $80-100^{\circ}C$. Sampling was done for 1 month after a 5 days interval. The L value of the Dolsan leaf mustard was found to be the highest at $80^{\circ}C$. The cutting force increased as the blanching temperature increased. The tensile strength decreased at $95^{\circ}C$ and $100^{\circ}C$. In addition, the sensory evaluation scores were the best at $80^{\circ}C$. The storage stability was assessed at various blanching temperatures to increase the sinigrin content during storage. Liquid chromatography with photodiode array and tandem mass spectrometry (LC-PDA/MS/MS) analysis was conducted to identify and quantify the sinigrin content in the Dolsan leaf mustard. Sinigrin as an internal standard was co-injected into each sample solution. The sample was monitored by recording the ultraviolet absorbance at 228 nm and by electrospray ionization (ESI) positive ion mode in the m/z 50-1,500 range. Blanching the sample at $80^{\circ}C$ showed the highest sinigrin concentration during storage among various temperatures and the maximum concentration was 350 ppm at 15 days storage. Study on utilization of vegetable from food processing of leaf mustard and preservation conservation results suggest that blanching at $80^{\circ}C$ is expected to improve the palatability of the pickle.

Simultaneous Analysis of Prohibited Antibiotics (Fluoroquinolones) in Seawater and Effluents Released by Aquaculture Using LC-MS/MS (LC-MS/MS를 이용한 해수 및 수산용수 중 플루오로퀴놀론계 항생제 동시 분석법 정립)

  • Mikyoung Lee;In-Seok Lee;Minkyu Choi;Sunggyu Lee;Won-Chan Lee
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.56 no.4
    • /
    • pp.428-437
    • /
    • 2023
  • A simultaneous analytical method was developed and validated for the analysis of prohibited fluoroquinolone (FQ) antibiotics including norfloxacin, ofloxacin, and pefloxacin, released by aquaculture in seawater and effluents. The samples were filtered, and extracts were obtained using a solid phase extraction cartridge with methanol (MeOH). The extracts were concentrated, and analyzed using ultra-performance liquid chromatography-tandem mass spectrometry. Two different columns and four different mobile phases were compared to achieve optimal separation and sensitivity for target compounds. Typical validation parameters including linearity, recovery of surrogate standard, instrument detection limit (IDL), limit of quantification (LOQ), and method detection limit (MDL) were evaluated. The linearity of calibration curves was over 0.999. Recoveries of surrogate ranged from 87.6% to 113%. The LOQ of target compounds was approximately 3-8 times lower than those reported in previous studies. The IDL and MDL were 0.06-0.57 and 0.06-0.37 ng/L, respectively. Seven effluent samples collected from an aquaculture located in Jeju were analyzed; however, not all target compounds were detected in the samples, suggesting that the banned antibiotics were not used. Overall, this established method was able to simultaneously analyze the three FQ antibiotics, and may be useful for monitoring prohibited antibiotics in the fishery industry.

Determination of Corticosteroids in Moisturizers by LC-MS/MS

  • Park, Sumin;Choi, Gye Young;Lee, Seon-Ah;Kim, Hyun Jeong;Yum, Hye Yung;Paeng, Ki-Jung
    • Mass Spectrometry Letters
    • /
    • v.7 no.1
    • /
    • pp.26-29
    • /
    • 2016
  • Simultaneous determination of three corticosteroids (clobetasol propionate, betamethasone dipropionate, fluticasone propionate) in moisturizers was performed by using liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS). Sample preparation was conducted by the liquid-liquid extraction (LLE). Moisturizers include emulsifying agent and it forms micelles. In order to improve the extraction efficiency of corticosteroids trapped in micelle, newly developed-optimized extraction conditions which can remove the matrix effect from moisturizers was applied with various pH conditions in LLE extraction stage of sample preparation. Thus, the addition of 10 μL of 1 M HCl into moisturizers sample before extraction could improve the extraction efficiency. For the quantitative analysis, SRM table that contained specific transition of all of target corticosteroids was created. The developed method was validated for linearity, accuracy, precision, limit of detection (LOD), limit of quantization (LOQ) and recovery. Over the 0.99 r2 value was obtained in calibration standard range. Effective accuracy and precision were also obtained. LODs were below 31 ng/mL and LOQs were estimated below 94 ng/mL for all corticosteroids tested.

Identification of Nandrolone and its Metabolite 5α-Estran-3β, 17α-Diol in Horse Urine after Chemical Derivatization by Liquid Chromatography Tandem Mass Spectrometry

  • Dubey, Saurabh;Beotra, Alka
    • Mass Spectrometry Letters
    • /
    • v.8 no.4
    • /
    • pp.90-97
    • /
    • 2017
  • Androgenic anabolic steroids (AASs) are synthetic derivatives of testosterone with a common structure containing cyclopentanoperhydrophenanthrene nucleus. Their use enhances the muscle building capacity and is beneficial during performance. The AASs are one of the most abused group of substances in horse doping. Liquid chromatography tandem mass spectrometry ($LC/MS^n$) has been successfully applied to the detection of anabolic steroids in biological samples. However, the saturated hydroxysteroids viz: nandrolone, $5{\alpha}-estrane-3{\beta}$, $17{\alpha}-diol$ exhibit lower detection responses in electrospray ionisation (ESI) because of their poor ionisation efficiency. To overcome this limitation pre-column chemical derivatization has been introduced to enhance their detection responses in $LC-ESI-MS^n$ analysis. The aim of present study was to develop a sensitive method for identification and confirmation of nandrolone and its metabolite in horse urine incorporating pre-column derivatization using picolinic acid. The method consists of extraction of targeted steroid conjugates by solid phase extraction (SPE). The eluted steroid conjugates were hydrolysed by methanolysis and free steroids were recovered with liquid-liquid extraction. The resulting steroids were derivatized to form picolinoyl esters and identification was done using LC-ESI-MS/MS in positive ionization mode. The picolinated steroid adduct enhanced the detection levels in comparison to underivatized steroids.

Metabolism of a New Neuroprotective Agent for Ischemia-Reperfusion Damage, KR-31543 in the Rats using Liquid Chromatography/Electrospray Mass Spectrometry

  • Kim, John;Ji, Hye-Young;Lee, Seung-Seok;Yoo, Sung-Eun;Kim, Sun-Ok;Lee, Dong-Ha;Lim, Hong;Lee, Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.25 no.5
    • /
    • pp.664-668
    • /
    • 2002
  • KR-31543,(2S,3R,4S)-6-amino-4-[N-(4-chlorophenyl)-N-(2-methyl-2H-tetrazol-5-ylmethyl)amino]-3,4-dihydro-2-dimethoxymethyl-3-hydroxy-2-methyl-2H-1-benzopyran is a new neuroprotetive agent for ischemia-reperfusion damage. The in vitro and in vivo metabolism of KR-31543 in rats has been studied by LC-electrospray mass spectrometry. Rat liver microsomal incubation of KR-31543 in the presence of NADPH resulted in the formation of a metabolite M1. M1 was identified as N-(4-chlorophenyl)-N-(2-methyl-2H-tetrazol-5-ylmethyl)amine on the basis of LC-MS/MS analysis with the synthesized authentic standard. Rat CYP3A1 and 3A2 are the major CYP isozymes involved in the formation of M1.

Identification of Antioxidative Constituents from Polygonum aviculare using LC-MS Coupled with DPPH Assay

  • Shin, Hyeji;Chung, Hayeon;Park, Byoungduck;Lee, Ki Yong
    • Natural Product Sciences
    • /
    • v.22 no.1
    • /
    • pp.64-69
    • /
    • 2016
  • A method for simultaneously identifying antioxidative compounds was developed using time-based LC-MS coupled with DPPH assay regardless of the time consuming process. The methanolic extract of Polygonum aviculare (Polygonaceae) showed significant DPPH radical scavenging activity. Time-based DPPH assay for simultaneous identification of active compounds from the extracts of P. aviculare was used. Major peaks of ethyl acetate fraction of P. aviculare showed high DPPH radical scavenging activity. A simple phenolic compound (1) and six flavonoids (2-7) were isolated from the ethyl acetate fraction of P. aviculare by silica gel and sephadex LH-20 column chromatography. The structures of seven compounds were determined to be protocatechuic acid (1), catechin (2), myricitrin (3), epicatechin-3-O-gallate (4), avicularin (5), quercitrin (6), and juglanin (7) based on the analysis of the $^1H$-NMR, $^{13}C$-NMR and ESI-MS data. All compounds exhibited significant antioxidant activity on DPPH assay and active compounds were well correlated with predicted one.

Simultaneous Liquid Chromatography Tandem Mass Spectrometric Determination of 35 Prohibited Substances in Equine Plasma for Doping Control

  • Kwak, Young Beom;Yu, Jundong;Yoo, Hye Hyun
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.158-165
    • /
    • 2022
  • Many therapeutic class drugs such as beta-blocker, corticosteroids, NSAIDs, etc are prohibited substances in the horse racing industry. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) technology makes it possible to isolate drugs from interference, enables various drug analyses in complex biological samples due to its sensitive sensitivity, and has been successfully applied to doping control. In this paper, we describe a rapid and sensitive method based on solid-phase extraction (SPE) using solid phase cartridge and LC-MS/MS to screen for different class's 35 drug targets in equine plasma. Plasma samples were pretreated by SPE with the NEXUS cartridge consisted non-polar carbon resin and minimum buffer solvent. Chromatographic separation of the analytes was performed on ACQUITY HSS C18 column (2.1 × 150 mm, 1.8 ㎛). The elution gradient was conducted with 5 mM ammonium formate (pH 3.0) in distilled water and 0.1% formic acid in acetonitrile at a flow rate of 0.25 mL/min. The selected reaction monitoring (SRM) mode was used for drug screening with multiple transitions in the positive ionization mode. The specificity, limit of detection, recovery, and stability was evaluated for validation. The method was found to be sensitive and reproducible for drug screening. The method was applied to plasma sample analysis for the proficiency test from the Association of Racing Chemist.

Determination of S- and R-Amlodipine in Rat Plasma using LC-MS/MS After Oral Administration of S-Amlodipine and Racemic Amlodipine

  • Yoo, Hye-Hyun;Kim, Tae-Kon;Lee, Bong-Yong;Kim, Dong-Hyun
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.88-91
    • /
    • 2011
  • The pharmacokinetic properties of S-amlodipine were studied using racemic amlodipine and single S-enantiomer (SK310) administration to rats. Plasma levels of the drug were determined using chiral liquid chromatography coupled with tandem mass spectrometry following solid phase extraction. The stereospecific analysis of amlodipine was performed on an ${\alpha}$-acid glycoprotein (AGP) column using a mobile phase comprising 10 mM ammonium acetate (pH 4.0) and propanol at a flow rate of 0.2 mL/min. This method was used to perform a comparative study of the pharmacokinetics of amlodipine and SK310. The results revealed that the pharmacokinetic profile of S-amlodipine after the administration of SK310 was comparable to that following the administration of the racemic mixture.

Application of Physiologically Based Pharmacokinetic Modeling with Biological Monitoring Data for Risk Assessment (생물학적 모니터링 데이터를 기초한 PBPK 모델의 활용)

  • Yang, Mi-Hi;Yang, Ji-Yeon;Yi, Bit-Na;Lee, Ho-Sun
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.1 s.56
    • /
    • pp.1-8
    • /
    • 2007
  • Biological monitoring, analyses of internal dose for exposure to toxicants, has been thought as one of the belt approaches for risk assessment. As the amount detected in human samples is generally very low, typically in the parts-per-bilion (ppb) or parts-per-trillion (ppt) range, analytic technologies such at HPLC, GC/MS, LC/MS, and LC/MS/MS have been continuously developed. In addition, route specific and sensitive exposure biomarkers have been developed for proper biological monitoring. PBPK modeling, particularly reverse dosimetry, has been emphasized as an useful method via interpretation of biological monitoring results for regulation of toxicants. Thus, this review is focused on the use of PBPK dosimetry models for toxicology research and risk assessment in Korea.

Regression model for the preparation of calibration curve in the quantitative LC-MS/MS analysis of urinary methamphetamine, amphetamine and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid using R (소변 중 메트암페타민, 암페타민 및 대마 대사체 LC-MS/MS 정량분석에서 검량선 작성을 위한 R을 활용한 회귀모델 선택)

  • Kim, Jin Young;Shin, Dong Won
    • Analytical Science and Technology
    • /
    • v.34 no.6
    • /
    • pp.241-250
    • /
    • 2021
  • Calibration curves are essential in quantitative methods and for improving the accuracy of analyte measurements in biological samples. In this study, a statistical analysis model built in the R language (The R Foundation for Statistical Computing) was used to identify a set of weighting factors and regression models based on a stepwise selection criteria. An LC-MS/MS method was used to detect the presence of urinary methamphetamine, amphetamine, and 11-nor-9-carboxy-Δ9 -tetrahydrocannabinol in a sample set. Weighting factors for the calibration curves were derived by calculating the heteroscedasticity of the measurements, where the presence of heteroscedasticity was determined via variance tests. The optimal regression model and weighting factor were chosen according to the sum of the absolute percentage relative error. Subsequently, the order of the regression model was calculated using a partial variance test. The proposed statistical analysis tool facilitated selection of the optimal calibration model and detection of methamphetamine, amphetamine, and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in urine. Thus, this study for the selection of weighting and the use of a complex regression equation may provide insights for linear and quadratic regressions in analytical and bioanalytical measurements.