• Title/Summary/Keyword: LASER

Search Result 14,326, Processing Time 0.037 seconds

Development of an Optical Tissue Clearing Laser Probe System

  • Yeo, Changmin;Kang, Heesung;Bae, Yunjin;Park, Jihoon;Nelson, J. Stuart;Lee, Kyoung-Joung;Jung, Byungjo
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.289-295
    • /
    • 2013
  • Although low-level laser therapy (LLLT) has been a valuable therapeutic technology in the clinic, its efficacy may be reduced in deep tissue layers due to strong light scattering which limits the photon density. In order to enhance the photon density in deep tissue layers, this study developed an optical tissue clearing (OTC) laser probe (OTCLP) system which can utilize four different OTC methods: 1) tissue temperature control from 40 to $10^{\circ}C$; 2) laser pulse frequency from 5 to 30 Hz; 3) glycerol injection at a local region; and 4) a combination of the aforementioned three methods. The efficacy of the OTC methods was evaluated and compared by investigating laser beam profiles in ex-vivo porcine skin samples. Results demonstrated that total (peak) intensity at full width at half maximum of laser beam profile when compared to control data was increased: 1) 1.21(1.39)-fold at $10^{\circ}C$; 2) 1.22 (1.49)-fold at a laser pulse frequency of 5 Hz; 3) 1.64 (2.41)-fold with 95% glycerol injection; 4) 1.86 (3.4)-fold with the combination method. In conclusion, the OTCLP system successfully improved the laser photon density in deep tissue layers and may be utilized as a useful tool in LLLT by increasing laser photon density.

Preliminary Perfomances Anlaysis of 1.5-m Scale Multi-Purpose Laser Ranging System (1.5m급 다목적형 레이저 추적 시스템 예비 성능 분석)

  • Son, Seok-Hyeon;Lim, Jae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.771-780
    • /
    • 2021
  • The space Debris laser ranging system is called to be a definite type of satellite laser ranging system that measures the distance to satellites. It is a system that performs POD (Precise Orbit Determination) by measuring time of flight by firing a laser. Distance precision can be measured in mm-level units, and it is the most precise system among existing systems. Currently, KASI has built SLR in Sejong and Geochang, and utilized SLR data to verify the precise orbits of the STSAT-2C and KOMASAT-5. In recent years, due to the fall or collision of space debris, its satellites have been threatened, and in terms of security, laser tracking of space objects is receiving great interest in order to protect their own space assets and protect the safety of the people. In this paper, a 1.5m-class main mirror was applied for the system design of a multipurpose laser tracking system that considers satellite laser ranging and space object laser tracking. System preliminary performance analysis was performed based on Link Budget analysis considering specifications of major components.

Comparison of Heat Transfer Theory, CFD and Experimental Results in the Design Process of High-Power Fiber Laser Cooling Plate (고출력 광섬유 레이저 냉각판 설계과정에서 나타난 열전달 이론, CFD 및 실험 결과값의 비교)

  • Kim, Taewoo;Lee, Kangin;Jeong, Minwan;Jeong, Yeji;Koh, KwangUoong;Lee, Yongsoo
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.6
    • /
    • pp.629-637
    • /
    • 2021
  • For the stabilization of laser output power and wavelength of the high power fiber laser, the cooling plate must be properly taken into account. In this study, three analyzing methods which are heat transfer theory, CFD and experiment are used to analyze cooling plate performance by measuring pump Laser Diode(LD) temperature. Under limited operating conditions of a cooling plate, the internal flow of cooling plate is transitional flow so that the internal flow is assumed to be laminar and turbulence flow and conducted theoretical calculation. Through CFD, temperature of pump LD and characteristics of the internal flow were analyzed. By the experiment, temperature of pump LD was measured in real conditions and the performance of the cooling plate was verified. The results of this study indicate that three analyzing methods are practically useful to design the cooling plate for the high power fiber laser or similar things.

Immediate effect of Nd:YAG laser monotherapy on subgingival periodontal pathogens: a pilot clinical study

  • McCawley, Thomas K.;McCawley, Mark N.;Rams, Thomas E.
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.1
    • /
    • pp.77-87
    • /
    • 2022
  • Purpose: This pilot study assessed the immediate in vivo effect of high peak pulse power neodymium-doped yttrium aluminum garnet (Nd:YAG) laser monotherapy on selected red/orange complex periodontal pathogens in deep human periodontal pockets. Methods: Twelve adults with severe periodontitis were treated with the Laser-Assisted New Attachment Procedure (LANAP®) surgical protocol, wherein a free-running, digitally pulsed, Nd:YAG dental laser was used as the initial therapeutic step before mechanical root debridement. Using a flexible optical fiber in a handpiece, Nd:YAG laser energy, at a density of 196 J/cm2 and a high peak pulse power of 1,333 W/pulse, was directed parallel to untreated tooth root surfaces in sequential coronal-apical passes to clinical periodontal probing depths, for a total applied energy dose of approximately 8-12 joules per millimeter of periodontal probing depth at each periodontal site. Subgingival biofilm specimens were collected from each patient before and immediately after Nd:YAG laser monotherapy from periodontal pockets exhibiting ≥6 mm probing depths and bleeding on probing. Selected red/orange complex periodontal pathogens (Porphyromonas gingivalis, Tannerella forsythia, Prevotella intermedia/nigrescens, Fusobacterium nucleatum, Parvimonas micra, and Campylobacter species) were quantified in the subgingival samples using established anaerobic culture techniques. Results: All immediate post-treatment subgingival biofilm specimens continued to yield microbial growth after Nd:YAG laser monotherapy. The mean levels of total cultivable red/orange complex periodontal pathogens per patient significantly decreased from 12.0% pretreatment to 4.9% (a 59.2% decrease) immediately after Nd:YAG laser monotherapy, with 3 (25%) patients rendered culture-negative for all evaluated red/orange complex periodontal pathogens. Conclusions: High peak pulse power Nd:YAG laser monotherapy, used as the initial step in the LANAP® surgical protocol on mature subgingival biofilms, immediately induced significant reductions of nearly 60% in the mean total cultivable red/orange complex periodontal pathogen proportions per patient prior to mechanical root instrumentation and the rest of the LANAP® surgical protocol.

Histologic Evaluation of Blood Vessels Sealed with 1,470-nm Diode Laser: Determination of Adequate Condition for Laser Vessel Sealing

  • Im, Nu-Ri;Moon, Jungho;Choi, Wonshik;Kim, Byoungjae;Lee, Jung Joo;Kim, Heejin;Baek, Seung-Kuk
    • Medical Lasers
    • /
    • v.7 no.1
    • /
    • pp.6-12
    • /
    • 2018
  • Introduction Energy-based devices allow for a more rapid and efficient ligation of blood vessels during operations. In the present study, we evaluated the feasibility of a laser as an alternative energy source for the vessel sealing system and determined the optimal condition of laser for an effective vessel sealing through histologic examination. Materials and Methods The arteries (5 mm diameter) harvested from porcine legs were compressed between two glass-slides to eliminate its luminal space and were irradiated with 1,470-nm diode laser under various sealing conditions, including laser power (5-30 W), irradiation time (5 or 10 seconds), and focus mode (focus or defocus). Subsequently, the irradiated vessels were fixed in 4% formaldehyde and then processed to paraffin block. The paraffinized sample was sectioned and stained with hematoxylin and eosin for histological evaluation. Results The extent of tissue change was positively correlated with duration and power of laser. In defocus mode, the irradiated vessels showed sufficient tissue denaturation for sealing effect without severe tissue destruction. Moreover, among the various conditions of irradiation, laser power between 15 and 20 W, as well as exposure time of 5 seconds were appropriate for sealing the blood vessels. Conclusion Adequate power and irradiation duration of laser can render blood vessels to be sealed effectively, although the higher power of laser may be required to cut the vessels.

Controlled Surface Functionalities of metals using Femtosecond Laser-induced Nano- and Micro-scale Surface Structures (펨토초 레이저 유도 나노 및 마이크로 구조물을 활용한 금속 표면 기능성 제어)

  • Taehoon Park;Hyo Soo Lee;Hai Joong Lee;Taek Yong Hwang
    • Design & Manufacturing
    • /
    • v.17 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • With femtosecond (fs) laser pulse irradiation on metals, various types of nano- and micro-scale structures can be naturally induced at the surface through laser-matter interaction. Two notable structures are laser-induced periodic surface structures (LIPSSs) and cone/spike structures, which are known to significantly modify the optical and physical properties of metal surfaces. In this work, we irradiate fs laser pulses onto various types of metals, cold-rolled steel, pickled & oiled steel, Fe-18Cr-8Ni alloy, Zn-Mg-Al alloy coated steel, and pure Cu which can be useful for precise molding and imprinting processes, and adjust the morphological profiles of LIPSSs and cone/spike structures for clear structural coloration and a larger range of surface wettability control, respectively, by changing the fluence of laser and the speed of raster scan. The periods of LIPSSs on metals used in our experiments are nearly independent of laser fluence. Accordingly, the structural coloration of the surface with LIPSSs can be optimized with the morphological profile of LIPSSs, controlled only by the speed of the raster scan once the laser fluence is determined for each metal sample. However, different from LIPSSs, we demonstrate that the morphological profiles of the cone/spike structures, including their size, shape, and density, can be manipulated with both the laser fluence and the raster scan speed to increase a change in the contact angle. By injection molding and imprinting processes, it is expected that fs laser-induced surface structures on metals can be replicated to the plastic surfaces and potentially beneficial to control the optical and wetting properties of the surface of injection molded and imprinted products.

The Effect of ER:YAG Laser & ER,CR:YSGG Laser on the Tissue of the Inflammation-Induced Mouse (Er:YAG 레이저와 Er,Cr: YSGG 레이저가 염증유발 마우스조직에 미치는 영향)

  • Park, Tae-Il;Lee, Hyung-Seok;Lee, Hee-Jong;Chae, Chang-Hoon;Lee, Young-Joo;Byeon, Kwang-Seob;Hong, Soon-Min;Choi, Mee-Ra;Park, Jun-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.5
    • /
    • pp.396-405
    • /
    • 2010
  • Purpose: This study was performed to find out the effects of the Er:YAG laser (Key Laser) & Er,Cr:YSGG laser (Water Laser) on inflammatory tissues. Materials and Methods: It was performed on about 20 g, 6 weeks male ICR mouses. They were grouped into the control (negative), the inflammation induced 'control'(positive), Er,Cr:YSGG laser exposured group after inducing inflammation, Er:YAG lasere exposured group after inducing inflammation each 15 mouses. The mouses were applicated 0.5% DNFB 1 cc on ear skin twice a day for 4 days until symptom expression. After laser exposure, ear tissues were extracted and defined gene expression by RT-PCR. Then, tissue staining, lymphocytes observation, electromicroscophic laboratory were carried out. Results: Interleukin-$1{\beta}$ was expressed much less in the A-laser exposed group. Interleukin-$1{\beta}$ & Tumor Necrosis Factor-${\alpha}$ were expressed 7 times lesser in the A-laser exposed group. The number of Lymphocytes related to inflammation was decreased rapidly in the A-laser exposed group in vivo. he number of cavity recovered normal was a little bigger in the A-laser exposed group after 5 days Conclusion: The expression of IL-$1{\beta}$ & TNF-${\alpha}$, hitologic change, observation with electron microscope shows that Erbium laser exposure causes lesser inflammation with A-laser rather than B-laser.

A HISTOLOGICAL CHANGES AND CGRP EXPRESSION AFTER EXPOSURE INJURY BY ER:YAG LASER IN DENTAL PULP OF RAT (흰쥐 치수에서 Er:YAG laser에 의한 노출손상에 따른 조직학적 변화 및 CGRP 단백질의 발현)

  • Yang, Jae-Ho;Park, Jong-Tae;Kim, Kyu-Tag;Kim, Sang-Bong;Lee, Nan-Young;Lee, Sang-Ho;Kim, Heung-Joong
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2008
  • The purpose of this study was to investigate early histological changes and calcitonin gene-related peptide (CGRP) expression in the dental pulp of the rat after Er:YAG laser preparation. Occlusal cavities were prepared in the upper first molars using either Er:YAG laser and conventional bur. At 48 hours after cavity preparation, the teeth were processed for hematoxylin-eosin stain and CGRP immunohistochemistry. The results were as follows : 1. The cavity floor by Er:YAG laser preparation was more irregular shape compared with those by bur preparation and there are some cracks in the directions of dentinal tubules. 2. There were more inflammatory cell infiltration and disruption of odontoblast in the dental pulp by Er:YAG laser preparation in comparison with the dental pulp by bur preparation. 3. CGRP expression in the pulp tissue by both Er:YAG laser and bur preparations were increased and higher than in the normal pulp. The expression pattern of CGRP was more strong in the pulp by Er:YAG laser preparation. These results indicate that Er:YAG laser is useful in the operative dentistry such as caries removal and cavity preparation if properly applied.

  • PDF

Comparative Study of Wound Healing in Porcine Uterus with $CO_2$ Laser and Scalpel Incisions ($CO_2$ Laser와 Scalpel을 이용한 절개 시 돼지 자궁에서의 창상 치유 평가)

  • Lee, Jae-Yeon;Park, Chang-Sik;Cho, Sung-Whan;Jeong, Seong-Mok;Kim, Myung-Cheol
    • Journal of Veterinary Clinics
    • /
    • v.26 no.6
    • /
    • pp.563-567
    • /
    • 2009
  • This study compared the instrument performance and tissue healing of a steel scalpel with a $CO_2$ laser in an animal uterine surgery model. Five Landrace and Yorkshire mixed breed pigs were used. Two symmetrical incisions were made in the uterine of each pig. One incision was made on the left side of the uterine horn using a steel scalpel, while the other incision was performed on the right side using a $CO_2$ laser with an 8W output power. Each instrument was evaluated clinically for speed, ease of incision, and extent of bleeding. An ovariohysterectomy was performed at 21 days after the surgical procedure for a histological examination. The scalpel was an easier instrument to use in the confines of the uterine tissue, compared with the laser. However, there is no significant difference between the two groups. The amount of bleeding was less in the laser group but the time of the incisions was shorter with the scalpel. Postoperative uterus adhesion in the $CO_2$ laser incisions was lower than the scalpel incisions. Scalpel incisions showed complete restoration of the epithelium and endometrial gland. On the other hand, the laser incisions showed incomplete restoration of the epithelium and endometrial gland. Although the scalpel produced less damage to the uterine tissue and was easier to handle than the $CO_2$ laser, it did not provide hemostasis that was helpful for use on highly vascular tissue. The $CO_2$ laser provided good hemostasis but delayed wound healing.

Use of Non-Contact Type Diode Laser on Assisted Hatching of Mouse Embryos (생쥐 수정란의 보조부화술에 있어서 Non-Contact Type인 Diode Laser의 이용)

  • Kim, D.H.;Lee, M.S.;Kang, H.G.;Han, S.W.;Kim, M.K.;Park, W.I.;Lee, H.T.;Chung, K.S.;Lee, H.J.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.185-192
    • /
    • 1999
  • The present study was performed to investigate the efficacy and safety of laser assisted hatching (AH) on mouse embryos. Non-contact $1.48{\mu}m$ diode laser system used to create a precise hole on zona pellucida. 2-cell embryos were collected from the mice (ICR) that had the coitus vaginal plug confirmed at 48 hours after hCG injection. Collected 2-cell embryos were cultured in the HTF medium supplemented with 0.4% BSA. For experiments, embryos at 8-cell stage were used after 18-22 hours in culture. After assisted hatching, the embryos were further cultured in HTF medium containing 0.1% PVP (anti-hatching system) for 3 days. For evaluate efficiency of laser on mouse embryo hatching, the effect of AH methods (acidic tyrode, pronase and laser), the number of artificial holes (1, 2 and 3 hole) and the irradiation time of laser (2, 4, 6, 8 and 10 ms) were examined. Hatching rates of laser AH group (95.2%) was significantly higher than that of control group (50.8%), but there was no differences among the laser (95.2%), acidic tyrode (100%) and pronase (98.5%) groups. Hatching rates of the number of zona pellucida opening by laser, there were no differences among the 1 hole (87.5%),2 hole (92.1%) and 3 hole (85.9%) groups. Developmental and hatching rates of embryos according to laser irradiation time were similar in the treatment groups. Therefore, these results suggest that laser AH using non-contact $1.48{\mu}m$ diode laser is a simple and accurate and effective procedure for AH. Based on these results, laser AH could be use safely for human ART program.

  • PDF