• Title/Summary/Keyword: LAMP2

Search Result 1,125, Processing Time 0.024 seconds

Effectiveness of Photocatalytic Techniques for Disinfection of Indoor Bioaerosols (실내 미생물 입자 살균을 위한 광촉매 기술의 효율)

  • Shin, Seoung-Ho;Kim, Mo-Geun;Jo, Wan-Kuen
    • Journal of Environmental Science International
    • /
    • v.16 no.7
    • /
    • pp.785-791
    • /
    • 2007
  • The current study evaluated the technical feasibility of the application of titanium dioxide ($TiO_{2}$) photo-catalytic air cleaners for the disinfection of bioaerosols present in indoor air. The evaluation included both laboratory and field tests and the tests of hydraulic diameter (HD) and lamp type (LT). Disinfection efficiency of photocatalytic oxidation (PCO) technique was estimated by survival ratio of bacteria or fungi calculated from the number of viable cells which form colonies on the nutrient agar plates. It was suggested that the reactor coating with $TiO_{2}$ did not enhance the adsorption of bioaerosols, and that the UV irradiation has certain extent of disinfection efficiency. The disinfection efficiency increased as HD decreased, most likely due to the decrease in the light intensity since the distance of the catalyst from the light source increased when increasing the HD. It was further suggested that the mass transfer effects were not as important as the light intensity effects on the PCO disinfection efficiency of bioaerosols. Germicidal lamp was superior to the black lamp for the disinfection of airborne bacteria and fungi, which is supported by the finding that the disinfection efficiencies were higher when the germicidal lamp was used compared to the black lamp in the laboratory test. These findings, combined with operational attributes such as a low pressure drop across the reactor and ambient temperature operation, can make the PCO reactor a possible tool in the effort to improve indoor bioaerosol levels.

Discharging Voltage Control with Error Detecting for Search light of Ship (선박용 탐사조명 전원장치의 방전개시전압 제어와 조명 이상검출)

  • Park, Noh-Sik;Kwon, Soon-Jae;Lee, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.10
    • /
    • pp.8-17
    • /
    • 2008
  • This paper presents a stable lighting method for HID lamp for ship from initial discharging current limit with discharging voltage control. The output voltage of the proposed control scheme is boosted for ignition, and the charging voltage is decreased by the resistor discharging. The proposed controller fires the initial discharge at the designed discharging voltage to limit the discharge current. After the discharging, constant current controller is used for brightness in steady state. The proposed control scheme can limit the initial discharge current using the starting point control without a complex voltage controller. so it can improve the life-time of HID lamp and get a stable discharge from restricted the initial discharge current. In order to improve the protection of the system, a simple instantaneous error detecting circuit for open state and short state of HID lamp is used. The proposed error detecting of HID lamp can protect the power system of lamp control. The effectiveness of the proposed controller is verified from the experiments of practical 2.5[kW] HID search light for ship.

Fishing efficiency of LED fishing lamp for squid Todarodes pacificus by training ship (실습선에 의한 LED 집어등의 오징어 어획성능)

  • An, Young-Il;Jeong, Hak-Geun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.3
    • /
    • pp.187-194
    • /
    • 2012
  • This study surveyed the fishing efficiency for Japanese common squid based on improvements made to LED fishing lamps by utilizing the training ship of Gangwon Provincial College. The training ship, Haesong-ho (24 tons), was equipped with seventy-two 150W electric power LED fishing lamps (10.8kW), and their fishing efficiency and fuel consumption level were surveyed for a total of ten times during the period between June 15, 2009 and July 27, 2009. In addition, the training ship was equipped with seventy-one 300W electric power LED fishing lamps (21.3kW) and their fishing efficiency and fuel consumption level were surveyed for a total of five times during the period between January 17, 2010 and August 4, 2010. In order to compare the fishing efficiency of LED fishing lamps, the catch of another fishing vessel equipped with Metal Halide (MH) fishing lamps of 120kW for the same period and at the same fishing grounds. The fuel consumption levels during the fishing operation of Haesong-ho was about 1,047.7 liters which was approximately 19.9% of the total fuel consumption level of 5,262.6 liters, and the fuel consumption level per operation hour was on average 9.2 liters. The number of Japanese common squid caught by the LED fishing lamp-equipped fishing vessel ranged from 12 to 1,640 squid for each fishing trial and the average quantity was 652. The number of Japanese common squid caught by the MH fishing lamp-equipped 10 fishing vessels ranged from 40 to 4,800 squid and the average quantity was 2,055. The fishing of Japanese common squid was done by the use of hand lines and an automatic jigging machine. The number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 50.8% to 49.2% with respect to the LED fishing lamp-equipped fishing vessel. However, the number of Japanese common squid caught per hand line and a single roller of the automatic jigging machine was in the proportion of 86.4% to 13.6% with respect to the MH fishing lamp-equipped fishing vessel where most of the catch was made by hand lines. On the other hand, in comparing the number of Japanese common squid caught per automatic jigging machine, the number of squid caught by the LED fishing lamp-equipped fishing vessel was about the same or greater than the number of squid caught by the MH fishing lamp-equipped fishing vessel.

Transmittance Properties of Fishing Lamp in Stick-held Dip Net Fishing Vessel for Pacific Saury (꽁치봉수망 집어등 불빛의 수중 투과 특성)

  • Jo, Hyun-Su;Kim, Doo-Nam;Cho, Young-Bok;Lee, Ju-Hee;Kim, Hyung-Seok;Yang, Won-Seok;An, Heui-Chun;Han, Jin-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • The transmittance properties of fishing lamp in stick-held dip net fishing vessel for Pacific saury was investigated during nighttime operations in the North Pacific on May 19 and 24, 2003. The incandescent lamps of red color (750W${\times}$100) and halogen lamps (750W${\times}$521) were used as a fishing lamp for gathering Pacific saury. The relative irradiance of red incandescent lamp and halogen lamp in the air showed peak in 1,052nm of wave length. However, the irradiance of halogen lamp below 600nm of wave length was higher than that of incandescent lamp. The relationship between underwater illuminance (Y) and water depth (X) of sunlight in the observation areas A (37$^{\circ}$ 11'N, 178$^{\circ}$ 46'W) and B (31$^{\circ}$ 11'N, 178$^{\circ}$ 01'E) is represented as follows; $Y=2572.2{\cdot}e^{-0.0721X},\;R^2=0.9915$ $Y=3312.4{\cdot}e^{-0.0619X},\;R^2=0.9837$ The distribution of underwater illuminance of observation areas A and B showed low value of 0.31x and 0.61x in 50m depth, respectively. In the fishing grounds of Pacific saury, the light intensity of distribution depth was above 0.51x.

Evaluation of reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for detection of infectious hematopoietic necrosis virus (IHNV) (Infectious hematopoietic necrosis virus (IHNV)-검출 Reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) 법의 평가)

  • Kim, Wi-Sik;Jeon, Chan-Hyeok;Kim, Jeong-Ho;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.25 no.3
    • /
    • pp.257-262
    • /
    • 2012
  • A reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay was evaluated to monitor infectious hematopoietic necrosis virus (IHNV) from artificially infected rainbow trout Oncorhynchus mykiss. The cumulative mortalities of fish challenged with IHNV at $10^{6.5}\;TCID_{50}$/fish, $10^{5.5}\;TCID_{50}$/fish and $10^{4.5}\;TCID_{50}$/fish were 40%, 0% and 0%, respectively. Dead fish and survivors at 16 and 28 d post-challenge in each group were employed for IHNV detection by RT-LAMP assay and virus isolation using BF-2 cells. IHNV from $10^{4.3}$ to $10^{6.8}\;TCID_{50}/ml$ was isolated from all the dead fish and also detected in all of the examined dead fish by RT-LAMP assay. In survivors at 16 d, 60% (3/5 fish, $10^{2.8}-10^{5.05}\;TCID_{50}/ml$), 20% (1/5 fish, $10^{1.05}\;TCID_{50}/ml$) and 60% (3/5 fish, $10^{1.05}-10^{4.8}\;TCID_{50}/ml$) were found to be IHNV-positive by virus isolation in fish challenged with IHNV at $10^{6.5}\;TCID_{50}$/fish, $10^{5.5}\;TCID_{50}$/fish and $10^{4.5}\;TCID_{50}$/fish, respectively, while 20% (1/5 fish), 0% (0/5 fish) and 20% (1/5 fish) were IHNV-positive by RT-LAMP assay. No IHNV was detected in the survivors at 28 d and control fish. These results indicate that the RT-LAMP assay is useful for detection of IHNV in diseased fish although it is not enough to monitor virus in IHNV-survivors.

Development of PU Nanoweb Based Electroconductive Textiles and Exploration of Applicability as a Transmission Line for Smart Clothing (PU 나노웹 기반 전기전도성 텍스타일의 개발 및 스마트의류용 신호전달선으로의 적용 가능성 탐색)

  • Jang, Eunji;Cho, Gilsoo
    • Fashion & Textile Research Journal
    • /
    • v.20 no.1
    • /
    • pp.101-107
    • /
    • 2018
  • The purpose of this study is to develop the electroconductive textiles based on polyurethane(PU) nanoweb and to explore that it is applicable to smart clothing. The electroconductive textiles developed by coating 2.0 wt% aqueous dispersed non-oxidized graphene paste on the surface of PU nanoweb. The fabricated electroconductive nanoweb was applied as a transmission line to connect the LED lamp, and the brightness of the LED lamp was measured to confirm its performance. The nanoweb transmission line was fixed by two methods(seam sealing tape, embroidering) to connect the LED lamp and AA batteries. The results as follows, the brightness of the LED lamp fixed with seam sealing tape was about 82 lux, and which fixed with embroidering was about 57 lux. It represents that the nanoweb transmission line which fixed with the seam sealing tape has better electrical signal transmitting because the lux value higher than the one fixed by embroidering. In order to compare the performance of the nanoweb transmission line and the metal wire, we connected the LED lamp with copper wire. The brightness of copper wire connected LED lamp was about 193 lux. Although the electrical signal strength of the nanoweb transmission line was weaker than the copper wire, it was reachable to operate LED lamp. The results of this study will provide a basic data to develop the textile based electronic devices, and conducting wire for smart clothing.

Electromagnetic Simulation of Ring-shaped Electrodeless fluorescent Lamps and its Electrical and Optical Characteristics (환형 무전극 형광램프의 전자계 시뮬레이션, 전기적 및 광학적 특성)

  • 최용성;조주웅;이영환;김광수;박대희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.5
    • /
    • pp.552-559
    • /
    • 2004
  • In recent, there have been several developments in lamp technology that promise savings in electrical power consumption and improved quality of the lighting space. Above all, the advantage of ring-shaped electrodeless fluorescent lamp is the removal of internal electrodes and heating filaments that are a light-limiting factor of conventional fluorescent lamps. The ring-shaped electrodeless lamp is intended as a high efficiency replacement for the incandescent reflector lamp in many applications. Therefore, the life time of ring-shaped electrodeless fluorescent lamps is substantially higher than that of conventional fluorescent lamps and last up to 60,000 hours. In this paper, maxwell 3D finite element analysis program(Ansoft) was used to obtain electromagnetic properties associated with the coil and nearby structures. The electromagnetic emitting properties were presented by 3D simulation software operated at 250 KHz and some specific conditions. The optical characteristics were measured luminance and a temperature and an optical spectrum distribution for 10 min in a one minute interval at the same time. With a goal of finding alternative materials, we show measurement results of electrical characteristics of a ring-shaped electrodeless fluorescent lamp as a function of frequency and the number of coil turns using a highly permeable($\mu$$_{r}$(equation omitted) 2,000) Mn-Zn ferrite. These results are compared with those of conventional ring-shaped electrodeless fluorescent lamp. It is found that the resistance, inductance and impedance are increased while the quality factor decreases as frequency increases.s.

Operating Performance of hair-tail angling vessel using the LED and metal halide fishing lamp combination (LED와 메탈핼라이드 집어등을 겸용한 갈치채낚기 어선의 조업 성능)

  • An, Heui-Chun;Bae, Bong-Seong;Lee, Kyoung-Hoon;Park, Seong-Wook;Bae, Jae-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.48 no.4
    • /
    • pp.337-345
    • /
    • 2012
  • One of representative Korean fisheries, jigging and angling has 5,700 vessels for squid and hairtail. Hairtail angling is the most typical fishery in Jeju and has an enormous impact on regional economy. However, the price hike in oil and labor costs triggered the necessity of developing a high efficient and energy saving fish luring lamp in recent times. For that reason, this study aimed to analyze the fishing performance of the aircooled LED lamp targeting hairtail angling fishery. The experiment was conducted from September through October in 2009-2011 for a 9.77 ton of fishing vessel setting up 100 lamps. The fishing performance was tested compared with 6 vessels using metal halide lamps in the same waters. As the LED lamp's performance goes up, different lamps were used in 2008 for 80W, 2009 for 120W and 2011 for 180W respectively. The catch and CPUE of the experimental vessel have gradually increased respectively taking the $4^{th}$ and $6^{th}$ place in 2009, the $4^{th}$ and $2^{nd}$ place in 2010, the $1^{st}$ and $1^{st}$ place in 2011 among the 7 vessels. In summary, the LED fishing lamp showed higher fishing performance than comparison groups. It saved 33% of oil consumption and cut down on operating expenses and greenhouse gases emission.

Development and Characteristics of an Electronic Starter with Three Terminals for 32Watt Fluorescent Lamps (32Watt 형광등용 3단자 반도체 스타터의 개발 및 특성)

  • Park, Chong-Yeon;Jee, Kwang-Hyeon;Kim, Un-Kwang
    • Journal of Industrial Technology
    • /
    • v.17
    • /
    • pp.175-182
    • /
    • 1997
  • Various types of electronic starter have been developed for the general fluorescent lamps with magnetic-type ballasts. However, the FL032/T8 fluorescent lamp requires higher voltage to discharge the lamp. The general starter with two-terminal is not suitable for the FL032/T8 slim-line type fluorescent for its higher discharge voltage. The suitable starter with three terminals have been studied for the FL032/T8 lamp in this paper. The developed starter have better characteristics in view points of the discharge voltage magnitude. We have proposed and designed the three terminals electronic starter. The proposed starter have been experimented and compaired with the other 2-terminal general starters. By the experimental results, we have concluded that the proposed starter is suitable to the FL032/T8 lamp.

  • PDF

Fabrication of high brightness multi-lamp backlight system for a large size LCD panel inspection equipment

  • Chun, Young-Tea;Lim, Sung-Kyoo;Lee, Kwang-Kyu;Lee, Hwan-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.787-790
    • /
    • 2004
  • The large size and high brightness backlight system for LCD panel inspection equipment was designed, fabricated, and evaluated. The cold cathode fluorescent lamp (CCFL) instead of the hot cathode fluorescent lamp (HCFL) were used as the light source. The inverters for driving multi-lamp CCFL backlight systems were also designed and fabricated. The measured luminance of the fabricated CCFL backlight system was 20,000 cd/$m^2$ and the uniformity of the backlight was 85%. The fabricated backlight system was successfully applied to the LCD panel inspection equipment.

  • PDF