• Title/Summary/Keyword: L20법

Search Result 1,232, Processing Time 0.029 seconds

Study of Analytical Method for Diesel Fuel Using UV-Spectrophotometer in Water Samples (UV-Spectrophotometer 를 이용한 수중 경유 분석법)

  • Lee, Jong-Sik;Jung, Kwang-Yong
    • Korean Journal of Environmental Agriculture
    • /
    • v.18 no.1
    • /
    • pp.83-85
    • /
    • 1999
  • This study was conducted to find out analytical method for diesel fuel using uv-spectrophotometer in water samples. The optimum wavelength, detection limit and recoveries for desel fuel extracted with n-pentane were 257nm, $100{\sim}800mg/l$ and $102{\sim}121%$, respectively. This method were stable for measuring concentrations of desel fuel for 1 hour at $20{\pm}1^{\circ}C$ condition.

  • PDF

Performance Comparison of Regularization Methods in Electrical Resistance Tomography (전기 저항 단층촬영법에서의 조정기법 성능비교)

  • Kang, Suk-In;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.226-234
    • /
    • 2016
  • Electrical resistance tomography (ERT) is an imaging technique where the internal resistivity distribution inside an object is reconstructed. The ERT image reconstruction is a highly nonlinear ill-posed problem, so regularization methods are used to achieve desired image. The reconstruction outcome is dependent on the type of regularization method employed such as l2-norm, l1-norm, and total variation regularization method. That is, use of an appropriate regularization method considering the flow characteristics is necessary to attain good reconstruction performance. Therefore, in this paper, regularization methods are tested through numerical simulations with different flow conditions and the performance is compared.

Research for Selecting The Optimized Vitamin C Analysis Method (최적 비타민 C 분석법 선정에 관한 연구)

  • Choi, Won-Sun;Kim, Young-Jin;Jung, Jin-Young;Kim, Tae-Jin;Jung, Byung-Moon;Kim, Eung-Ryool;Jung, Hoo-Kil;Chun, Ho-Nam
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.6
    • /
    • pp.861-865
    • /
    • 2005
  • 2,4-Dinitrophenylhydrazine (DHP), indophenol, and HPLC methods, which are generally used to analyze vitamin C, were evaluated by comparing changes in vitamin C contents in various samples kept at 10 and $20^{\circ}C$. Amount of total ascorbic acid (TAA) in yoghurt A kept at $10^{\circ}C$, as measured by DNP method, decreased from 26.7mg/100mL for early period to 22.8mg/100mL for final period of storage, whereas, on 3rd and 10th storage days, increased contrary to general results. Using indophenol, TAA measured at 28.6 and 9.5mg/100mL, and 30.5 and 14.6mg/100mL using HPLC far early and final periods, respectively. With indophenol and HPLC, TAA amount showed steady tendency to decrease. In conclusion, HPLC is the most suitable method to analyze vitamin C content, and indophenol method can be also used during early storage stage.

Trace level analysis of Pb in plasma by inductively coupled plasma/mass spectrometry (유도결합플라즈마 질량분석법을 이용한 혈장 중 극미량 납 분석)

  • Lee, Sung-Bae;Yang, Jeong-Sun;Choi, Sung-Bong;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.3
    • /
    • pp.190-196
    • /
    • 2012
  • The human exposure of lead has usually detected the amount of lead in the whole blood, however, this method has a shortcoming to give the information on the short-term exposure to lead. In that sense, it is desirable to estimates the level of lead in plasma to draw the chronic bio-marker of lead exposure even though it is difficult to measure lead of several ng/L. An inductively coupled plasma-mass spectrometry (ICP-MS) method was developed for determining lead in plasma as the chronic bio-marker of lead of workers. To minimize the contamination of lead from the environment, we constructed class 1,000 clean room and compared the amount of floating dust before and after the operation of the clean room. The limit of detection (LOD) and the limit of quantification (LOQ) of lead in fetal bovine serum were 4.3 ng/L and 12.2 ng/L by NIOSH method (statistical calculation method) and 7.0 ng/L and 22.1 ng/L by signal/noise ratio, respectively. The accuracy was in a range of 92.3-101.3%, and the precision of the assay was less than 4% in the samples spiked in the concentration of 20 ng/L and 2,000 ng/L. The method was simple, reproducible and sensitive enough to permit reliable analysis of lead to the ng/L level in plasma and/or serum. The method was also useful for the biological monitoring of chronic exposure to lead.

Coagulating effects of several eco-friendly coagulant materials favorable for vermicomposting sewage sludge (하수슬러지에 대한 지렁이처리법 적용에 유리한 몇 가지 친환경 응집물질의 하수슬러지에 대한 응집효과)

  • Bae, Yoon-Hwan;Park, Soon-Cheol
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.23 no.1
    • /
    • pp.52-62
    • /
    • 2015
  • Coagulating effects of eco-friendly coagulant materials such as zeolite, kaolinite, loess and chitosan upon sewage sludge were evaluated. And coagulating effects of the mixtures of those materials and polymer (polyacrylamide) were also investigated. Coagulating efficiency of loess was higher than that of kaolinite and zeolite at the treatment levels of 2,500~50,000mg/L. Coagulating efficiencies of zeolite, kaolinite and loess at the treatment level of 20,000mg/L were lower than that of 1,000 mg/L of polymer, which meant that single application of those materials in real plant were not feasible. At the treatment level of 1,000 mg/L, coagulating efficiency of Chitosan was much lower than that of polymer, which also meant that single use of chitosan in real plant could be unrealistic because of its high price. However, the application of the mixture of 'polymer 80mg/L + kaolinite or loess 500 mg/L + chitosn 10mg/L' or the mixture of 'polymer 80mg/L + kaolinite or loess 500mg/L' was promising way for coagulating sewage sludge.

Polycyclic Aromatic Hydrocarbons in Agricultural Waterways in Gyeonggi and Gangwon Provinces, Korea (경기 및 강원지역 농업용수 중 PAHs의 모니터링 연구)

  • Kim, Leesun;Park, Byung-Jun;Lee, Sung-Eun
    • Korean Journal of Environmental Biology
    • /
    • v.34 no.3
    • /
    • pp.216-221
    • /
    • 2016
  • Level and distribution of fourteen polycyclic aromatic hydrocarbons (PAHs) in the agricultural water samples collected in the waterways located in Gyeonggi and Gangwon, Korea were determined for monitoring and risk assessment. A simplified, fast but effective extraction and clean-up methods combined with gas chromatography tandem mass spectrometry (GC-MS/MS) was employed to measure the concentration of the target compounds. The extraction of the analytes of interest in water sample (10 mL) was performed with acetonitrile (10 mL) and the salt. To purify the target PAHs, the clean-up procedure was employed with 2 mL tubes of dispersive solid phase extraction. The optimized method was validated with recoveries, method detection limit (MDL), accuracy and precision. Good recoveries for each PAHs at 10 and $25{\mu}g\;L^{-1}$ were achieved (60 to 110%, with RSD <20%) with linearity (>0.99). MDL for all the analytes was achieved with $0.2{\mu}g\;L^{-1}$. GC-MS/MS results showed that concentration of phenanthrene in the water samples from Gyeonggi (20 sites) ranged from 0.82 to $2.56{\mu}g\;L^{-1}$ and from Gangwon (15 sites) ranged from 0.83 to $1.62{\mu}g\;L^{-1}$. Other PAHs were not found in the water samples but the continuous monitoring for these areas were required.

Genetic Effects of Pesticides in the Mammalian Cells: II. Mutagenesis in L5178Y Cells and DNA Repair Induction

  • Park, sang-Gi;Lee, Se-Yong
    • The Korean Journal of Zoology
    • /
    • v.20 no.4
    • /
    • pp.159-168
    • /
    • 1977
  • In order to evaluate the mutagenic potentential in mammalian system for those pesticides which were proved to be mutagenic in Salmonella microsome assay system, we have studied drug-resistant mutagenesis in cultured L5178Y cells and unscheduled DNA synthesis in human lymphocytes in vitro. We have tested five pesticides: insecticides DDVP and trichlorfon, fungicide TMTD and herbicides MO and NIP. Of these pesticides, TMTD induced weak mutation to MTX-resistance in L5178Y cells in vitro and gave positive responses in DNA repair assay system. Therefore, its potential genetic risks in human beings should be re-evaluated. DDVP and trichlorfon gave negative response in L5178Y mutagenesis test system but stimulated incorporation of $^{3}H$-TdR in DNA repar assay. MO and NIP gave also negative responses both in L5178Y mutagenesis test systemand in DNA repair assay system.

  • PDF

Analysis of Geosmin and 2-MIB in Water by Stir Bar Sorptive Extraction (SBSE) and GC/MS (교반막대추출법(SBSE)과 GC/MS를 이용한 수중의 Geosmin과 2-MIB의 분석)

  • Lee, Hwa-Ja;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.1
    • /
    • pp.64-69
    • /
    • 2009
  • Musty and earth odors caused by geosmin and 2-MIB are the major complaints from the drinking water consumers. Therefore, early detection of geosmin and 2-MIB is the key to prevent off-flavor occurrence. In this study, a rapid method using stir bar sorptive extraction (SBSE) in combination with the GC/MS was investigated to analyze geosmin and 2-MIB in water. The SBSE method, a solventless extraction technique, was optimized and then applied to the analysis of geosmin and 2-MIB in water. The SBSE technique was found to be a simple and fast procedure that allows many samples to be extracted simultaneously using very small volume (10~20 mL). In addition, the SBSE method offered high recovery and good linear regression coefficient for the geosmin and 2-MIB. The good repeatability of this method can be deduced from the low RSD (7.2~7.6%) at 10 ng/L for geosmin and 2-MIB. The limit of detection was determined 1~2 ng/L and the limit of quantitation was 3~6 ng/L. Above all, the SBSE method proved to be a very practical technique for the analysis of geosmin and 2-MIB in water.

Thermal Analysis of Lithium-ion Cell Using Equivalent Properties and Lumped Capacitance Method (등가물성 및 집중용량법을 이용한 리튬-이온 전지의 열해석)

  • Lee, Hee Won;Park, Il Seouk
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.775-780
    • /
    • 2013
  • In general, the battery module of an electric vehicle (EV) consists of lithium-ion cells. A lithium-ion battery is a secondary rechargeable battery, and it consists of numerous stacked plates that serve as electrodes and separators. Owing to these microstructural features, its numerical analysis is very expensive. Therefore, this study aims to present a simplified thermal analysis model using equivalent thermal properties, and we compare the experimental results with numerical results for 185.3Ah and 20Ah cells. Furthermore, we show the thermal behavior of cells without the finite element method (FEM) or finite volume method (FVM) by adopting the lumped capacitance method (LCM).

Thickening Characteristics of Activated Sludge by Air Flotation Process (공기부상법을 이용한 활성슬러지의 부상분리 특성)

  • Park, Chanhyuk;Hong, Seok-won;Maeng, Juwon;Lee, Sanghyup;Choi, Yong-su;Moon, Seong-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.5
    • /
    • pp.747-753
    • /
    • 2006
  • Air flotation is a solid-liquid separation process that utilizes up-flow microbubbles to thicken activated sludge and enhance clarification efficiency. Continuous air flotation experiments were performed to investigate the effect of operation parameters such as initial MLSS (mixed liquor suspended solid) concentration, air pressure, surface loading rate, air to solid (A/S) ratio, and flotation time on thickening efficiency. An initial activated sludge concentration ranged from 3,000 to 12,000mgSS/L and thickened sludge concentration varied from 6,400 to 28,100mgSS/L. The result showed that the thickening efficiency was mainly dependent on surface loading rate, A/S ratio, and flotation time. The pressure did not affect the thickening efficiency when it kept in the range of 1.6 to 1.8 bar. Experimental results showed that the thickening efficiency of activated sludge was increased only when the feed sludge concentration exceeded 5,000mgSS/L and the thickened concentration was over 20,000mgSS/L. At this time, SS concentration in the clarified liquid was ranged from 5 to 10mg/L.