• 제목/요약/키워드: L1 transfer

검색결과 1,091건 처리시간 0.029초

오목표면에 분사되는 난류원형충돌제트에 대한 국소열전달계수 측정에 관한 연구 (Measurement of the Local Heat Transfer Coefficient on a Concave Surface with a Turbulent round Impinging Jet)

  • 임경빈
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.112-119
    • /
    • 1995
  • Measurements of the local heat transfer coeffcients on a spherically concave surface with a round impinging jet are presented. The liquid crystal transient method was used for these measurements. This method, which is a variation on the transient method, suddenly exposes a preheated wall to an impinging jet while video recording the response of liquid crystals for the measurement of the surface temperature. The Reynolds numbers used were 1,000, 23,000 and 50,000 and the nozzle-to-jet distance was L/d=2, 4, 6, 8, 10. Presented results are compared to previous measurements for flat plate. In the experiment, the local heat transfer Nusselt numbers on a concave surface are higher than those on a flat plate. Maximum Nusselt number at all region occured at L/d=6 and second maximum in the Nusselt number occured at R/d=2 for both Re=50,000 and Re=23,000 in case of L/d=2 and for only Re=50,000 in case of L/d=4. All other cases exhibit monotonically decreasing value of the Nusselt number along the curved surface.

  • PDF

수평단열판에 부착된 등온사각비임에서의 자연대류 열전달에 관학 수치해석 (A Numerical Study on the Natural Convection from a Square Beam with a Horizontal Adiabatic Plate)

  • 배석태;박재림;권순석
    • 태양에너지
    • /
    • 제10권1호
    • /
    • pp.22-30
    • /
    • 1990
  • 장방형 발열체 주위에서의 자연대류열전달 특성을 고찰하기 위하여, 주위유체가 공기인 정상 층류상태하에서 수평단열판에 부착된 등온 사각비임에서의 자연대류 열전달 해석을 비임의 형상과 Grashof수를 변수로 하여 수치해석하였다. 무차원 비임폭 W / L가 감소함에 따라 사각비임으로부터의 열전달은 증가하며 비임 상부면에서의 평균 Nusselt수는 W / L=0.25에서 최대, W / L=1.0에서 최소값을 나타내었다. 비임 측면의 경우는 W / L=1.0에서 최대, W / L=0.25에서 최소값을 나타내며 비임으로부터의 자연대류열절달은 비임폭의 지배적인 영향을 받는다.

  • PDF

유속 및 열전대 위치의 영향을 고려한 열경계층 내부의 복합열전달 해석 (NUMERICAL ANALYSIS OF CONJUGATE HEAT TRANSFER INSIDE A THERMAL BOUNDARY LAYER CONSIDERING THE EFFECTS OF A FREE STREAM VELOCITY AND A THERMOCOUPLE POSITION)

  • 전병진;이주안;최형권
    • 한국전산유체공학회지
    • /
    • 제18권1호
    • /
    • pp.77-82
    • /
    • 2013
  • The error in measuring temperature profiles by thermocouple inside boundary layer mostly comes from the conduction heat transfer of the thermocouple. The error is not negligible when the conductivity of the thermocouple is very high. In this study, the effect of conduction heat transfer of the thermocouple on the temperature profile inside boundary layer was examined by considering both free-stream velocity and a thermocouple position. The conduction error of an E-type thermocouple was investigated by numerical analysis of three-dimensional conjugate heat transfer for various velocity profiles of boundary layer and thermocouple positions.

Liquid Crystal을 이용한 원형충돌분류의 전열특성 연구 (Heat Transfer on a Heated Flat Plate by an Impinging Round Jet Using Liquid Crystal)

  • 오승묵;이상준
    • 대한기계학회논문집
    • /
    • 제16권8호
    • /
    • pp.1566-1574
    • /
    • 1992
  • 본 연구에서는 원형수직 충돌분류에 의한 가열평판의 전열특성을 해석하기 위 하여 최근 표면온도 측정에 많이 사용되고 있는 liquid crystal을 이용하였다. 즉 liquid crystal의 감온특성과 영상처리 기법을 이용하여 레이놀즈수 및 노즐과 충돌판 사이의 거리(L/D) 변화에 따른 전열면의 온도장 변화를 측정하였다.

임펄스응답 데이타의 펄스전달함수의 근사 (Approximation of Pulse Transfer Function of Impulse Response Data)

  • 이동철;배종일;정형환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.683-685
    • /
    • 1999
  • As a method of obtaining pulse transfer function. transfer function of discrete-time from input-output data, there are method of obtaining unknown parameter of pulse transfer function from estimated impulse response before(1-3). There is no need to approximate to several meanings because of not being established algebraical relations between impulse response for estimation error and parameter of transfer function exactly. In this paper, I inquire the method[4] of obtaining the optimal pulse transfer function as a meaning of Hankel norm approximation from impulse response data and examine estimated property as computer simulation from this method.

  • PDF

식물공장 자동화를 위한 공압 실린더를 이용한 육묘베드 이송장치의 이송력 특성 (Transfer Force Characteristics of Seedling Bed Transfer Equipment Using Pneumatic Cylinder for Automation of Plant Factory)

  • 민영봉;박상민;이공인;김동억;강동현;문성동
    • Journal of Biosystems Engineering
    • /
    • 제37권3호
    • /
    • pp.155-165
    • /
    • 2012
  • This study was performed to offer the data for design of the seedling bed transfer equipment to make the automation of working process in a plant factory. The seedling bed transfer equipment pushing the seedling bed with bearing wheels on the rail for interconnecting each working process by a pneumatic cylinder was made and examined. The examined transfer force to push the seedling bed with a weight of 178.9 N by the pneumatic cylinder with length of 60 cm and section area of 5 $cm^2$ was measured by experiments. The examined transfer forces was compared with theoretical ones calculated by the theoretical formula derived from dynamic system analysis according to the number of the seedling bed and pushing speed of the pneumatic cylinder head at no load. The transfer function of the equipment with the input variable as the pushing speed $V_{h0}$(m/s) and the output variable as the transfer force f(t)(N) was represented as $F(s)=(V_{h0}/k)(s+B/M)/(s(s^2+Bs/M+1/(kM))$ where M(kg), k(m/N) and B(Ns/m) are the mass of the bed, the compression coefficient of the pneumatic cylinder and the dynamic friction coefficient between the seedling bed and the rail, respectively. The examined transfer force curves and the theoretical ones were represented similar wave forms as to use the theoretical formular to design the device for the seedling bed transfer. The condition of no vibration of the transfer force curve was $kB^2>4M$. The condition of transferring the bed by the repeatable impact and vibration force according to difference of transfer distance of the pneumatic cylinder head from that of the bed was as $Ce^{-\frac{3{\pi}D}{2\omega}}<-1$, where ${\omega}=\sqrt{\frac{1}{kM}-\frac{B^2}{4M^2}}$, $C=\{\frac{\frac{B}{2M}-\frac{1}{kB}}{\omega}\}$, $D=\frac{B}{2M}$. The examined mean peak transfer force represented 4 times of the stead state transfer force. Therefore it seemed that the transfer force of the pneumatic cylinder required for design of the push device was 4Bv where v is the pushing speed.

파라퀴논 유도체와의 전하이동착물 형성을 이용한 에녹사신 정량 (The Determination of Enoxacin with p-Quinone Derivatives)

  • 이지연;김동오;남수자;정문모;허문회;안문규
    • 약학회지
    • /
    • 제43권4호
    • /
    • pp.437-441
    • /
    • 1999
  • Enoxacin[1-ethyl-6-fluoro-1,4-dihydro-4-oxo-7-(1-\piperazinyl)-1,8-naphthyridine-3-carboxylic acid, ENX] is a new quinolone antibacterial agent. The method is based on the highly colored charge-transfer complex formation of this drug as a $\pi$-electron donor with 7,7,8,8-tetracyanoquinodimethane(TCNQ) or chloranil(CL) as $\pi$-acceptors. The colored products were measured spectrophotometrically at 842 nm and 552 nm for TCNQ and CL, respectively. The different experimental conditions are optimized. The linearities for TCNQ and CL were $1.6{\;}\mu\textrm{g}/mL~32{\;}\mu\textrm{g}/mL$ and $6.4{\;}\mu\textrm{g}/mL~160{\;}\mu\textrm{g}/mL$, respectively and colors were produced in non-aqueous media. This report describes a simple and ra\pid method for the analysis of enoxacin.

  • PDF

유산균(乳酸菌)의 생물학적특성(生物學的特性)에 관한 연구(硏究) II. 약제내성(藥劑耐性) 유산균(乳酸菌)의 R Plasmids 전달빈도(傳達頻度) (Studies on Biological Characteristics of Lactobacillus II. Conjugal Transfer-frequency of R Plasmids from Lactobacillus to Escherichia coli)

  • 김종면;송희종
    • 대한수의학회지
    • /
    • 제20권2호
    • /
    • pp.113-118
    • /
    • 1980
  • Total of 11 strains of Ldctobacillus isolated from lactobacillus-fermented milk and-beverage in March 1980 were examined for susceptibility to 8 drugs, and transferability and transfer frequency of R plasmids by conjugation. Of 11 isolates each 2 strains were classified as L. cellobiosus and L. helveticus, each 1 strain as L. plantarum, L. lactis, L. acidophilus, L. delbrueckii, L. casei subsp. casei, L. casei subsp, tolerans and L. salivarius subsp, salivarius by Bergey's manual. Resistance was the most active to na lidixic acid(NA), followed in decreasing order by chloramphenicol(CP), ampicillin(AP), kanamycin(KM) and streptomycin(SM). All of isolates were resistant to NA, each 10 strains to CP and AP, 7strains to KM and 6 strains to SM, indicating all of the isolates were resistant to two or more drugs in combination. No strain was resistant to erythromycin(EM), penicillin(PC) and tetracycline(TC). The most frequently encountered resistant patterns were CP NA AP SM KM, followed by CP NA AP KM, NA AP, CP NA, CP NA AP and CP NA AP SM in order. Transfer experiment of drug resistance showed that of 11 resistant strains, 9 strains transferred parts of their resistance to AP or AP CP or SM AP, indicating 9 strains carried R plasmids determining R(AP), R(AP CP) and R(SM AP). The conjugal frequency of R(AP) from Lactobacillus to E. coli ranged from 2.5{\times}10^{-1} to $5.6{\times}10^{-4}%$, that of R(CP) ranged from 5.0{\times}10^{-1} to 5.0{\times}10^{-3}% and that of R(SM) ranged from 6.0{\times}10^{-5} to 1.4{\times}10^{-5}%, at $37^{\circ}C$ for 18 hours of incubation.

  • PDF

판형 열교환기 Full-scale 해석을 위한 1차원 유동 네트워크 모델 및 ε-NTU 모델의 수치적 연구 (NUMERICAL STUDY FOR THE FULL-SCALE ANALYSIS OF PLATE-TYPE HEAT EXCHANGER USING ONE-DIMENSIONAL FLOW NETWORK MODEL and ε-NTU METHOD)

  • 김민성;민준기;하만영
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Since a typical plate heat exchanger is made up of a huge number of unitary cells, it may be impossible to predict the aero-thermal performance of the full scale heat exchanger through three-dimensional numerical simulation due to the enormous amount of computing resources and time required. In the present study, a simple flow-network model using the friction factor correlation and a thermal-network model based on the effectiveness-number of transfer units (${\varepsilon}$-NTU) method has been developed. The complicated flow pattern inside the cross-corrugated heat exchanger has been modeled into flow and thermal networks. Using this model, the heat transfer between neighboring streams can be considered, and the pressure drop and the heat transfer rate of full-scale heat exchanger matrix are calculated. In the calculation, the aero-thermal performance of each unitary cell of the heat exchanger matrix was evaluated using correlations of the Fanning friction factor f and the Nusselt number Nu, which were calculated by unitary-cell CFD model.

광폭 루버 핀이 장착된 핀-관 열교환기의 공기측 전열 성능에 관한 실험적 연구 (An Experimental Study on the Airside Performance of Fin-and-Tube Heat Exchangers Having Wide Louver Fin)

  • 김내현
    • 설비공학논문집
    • /
    • 제27권5호
    • /
    • pp.254-262
    • /
    • 2015
  • Heat transfer rate can be increased by increasing the heat transfer area. In this study, wide louver fin-and-tube heat exchangers with $P_t/P_l=1.03$ were tested and compared with louver fin-and-tube heat exchanger with $P_t/P_l=0.6$. Results show that heat transfer capacities of wide louver samples are larger (9.8% at one row, 13.6% at two row and 4.1% at three row) than those of conventional louver samples. Considering the area ratio of 1.78, the increase of heat transfer capacity is rather small, possibly due to the smaller heat transfer coefficient and fin efficiency of the wide louver sample. The j factor of the louver fin was 67% larger at one row, 42% larger at two row and 52% larger at three row. The f factor of the louver fin was 81% larger at one row, 63% larger at two row and 60% larger at three row. The effect of fin pitch on j and f factors are not pronounced and the j factor decreased as the number of tube row increased.