• Title/Summary/Keyword: L-spine

Search Result 502, Processing Time 0.031 seconds

Age-related Geometric Effects on the Human Lumbar Spine by the Finite Element Method (유한 요소법을 이용한 나이에 따른 척추의 형상 및 구조변화의 효과)

  • Kim Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.285-293
    • /
    • 2000
  • Age-related changes in the geometry of human lumbar spine would lead to changes of its mechanical behaviors. To investigate the effects of the geometric changes, no age-related changes in the material/mechanical properties were considered. Using the finite element method. two age-related models of lumbar spine segments (L3-L4) were constructed. The annulus of the models was modeled as laminate composite elements with 16 layers and 6 materials. The spinal stiffness and facet reaction of the lumbar spine increased with the age-related geometric changes in various combined loadings. Fiber and transverse tensile strains of the inner annulus. cancellous bone stress and end-plate stress decreased with the age-related geometric changes whereas fiber/layer compressive strains of the annulus. facet reaction. ligament reaction and end-plate rigidity increased. Consequently, it appears that in the normal age-related deterioration of discs, the age-related geometric change contributes to the increase of spinal stiffness (the decrease in range of the motion segment), preventing an excessive deformation of the disc.

  • PDF

Effectiveness and Safety of Tranexamic Acid in Spinal Deformity Surgery

  • Choi, Ho Yong;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn;Kim, Hyun-Jib
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.75-81
    • /
    • 2017
  • Objective : Spinal deformity surgery has the potential risk of massive blood loss. To reduce surgical bleeding, the use of tranexamic acid (TXA) became popular in spinal surgery, recently. The purpose of this study was to determine the effectiveness of intra-operative TXA use to reduce surgical bleeding and transfusion requirements in spinal deformity surgery. Methods : A total of 132 consecutive patients undergoing multi-level posterior spinal segmental instrumented fusion (${\geq}5$ levels) were analyzed retrospectively. Primary outcome measures included intraoperative estimated blood loss (EBL), transfusion amount and rate of transfusion. Secondary outcome measures included postoperative transfusion amount, rate of transfusion, and complications associated with TXA or allogeneic blood transfusions. Results : The number of patients was 89 in TXA group and 43 in non-TXA group. There were no significant differences in demographic or surgical traits between the groups except hypertension. The EBL was significantly lower in TXA group than non-TXA group (841 vs. 1336 mL, p=0.002). TXA group also showed less intra-operative and postoperative transfusion requirements (544 vs. 812 mL, p=0.012; 193 vs. 359 mL, p=0.034). Based on multiple regression analysis, TXA use could reduce surgical bleeding by 371 mL (37 % of mean EBL). Complication rate was not different between the groups. Conclusion : TXA use can effectively reduce the amount of intra-operative bleeding and transfusion requirements in spinal deformity surgery. Future randomized controlled study could confirm the routine use of TXA in major spinal surgery.

Case Report of Two Cases on Effect of Combined Bee Venom and CS Pharmacopuncture with Koream Medicine Treatment on HIVD of L-spine (요추 추간판탈출증 환자에 대한 봉약침과 CS약침을 병행한 한의학적 복합치료 효과에 대한 증례보고)

  • Hwang, Ji Hye;Kim, Deok-Hyun
    • Korean Journal of Acupuncture
    • /
    • v.35 no.4
    • /
    • pp.239-246
    • /
    • 2018
  • Objective : This case study reports the therapeutic effect of Korean Medicine (KM) treatments including CS(care special pain) and BV(bee venom) pharmacopuncture on herniated intervertebral disc(HIVD) of lumbar spine(L-spine). Methods : Two patients diagnosed with HIVD of L-spine were treated with CS and BV pharmacopuncture on GV3 and EX-B2, acupuncture, cupping, and herbal medicine. The Numeric Rating Scale(NRS), the Oswestry low back pain Disablility Index(ODI) and the Roland Morris Disability Questionnaire(RMDQ) scores were evaluated before and after treatment for comparison. Results : Low back pain(LBP) and radiating pain was improved with a decrease in patients' NRS, ODI and RMDQ scores. Conclusion : These results suggest that KM treatments including combined CS and BV pharmacopuncture could be an effective treatment on patients with HIVD of L-Spine.

A Clinical Case of Oriental Medical Treatment for the Pregnant Woman with HNP at L-spine (임신 중 요추간판 탈출증 환자의 한의학적 치료효과)

  • Park, Min-Jung;Yu, Deok-Seon;Jung, Il-Min;Yeom, Seung-Ryong;Kwon, Young-Dal;Kwon, Young-Mi
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.20 no.4
    • /
    • pp.231-239
    • /
    • 2010
  • Objectives : This study was performed to report the effect and safety of oriental medical treatment in the pregnant woman diagnosed to herniation of nuclues pulposus(HNP) at L5-S1 with central protrusion and left S1 nerve root. Methods : A 32-year old pregnant woman diagnosed HNP at L5-S1 at local hospital was admitted with low back pain and left leg rad pain. We treated her by acupuncture, a herbal medicine, cupping treatment and measured visual analogue scale(VAS), Oswestry disability index(ODI) and Roland-Morris disability qustionnaire(RMDQ) from 5th March 2010 to 26th March 2010. Results : After treatment, most symptoms decreased, VAS score changed 10 to 2, ODI changed 388, RMDQ changed 13 to 6. Conclusions : In this study, oriental medical treatment was effective and safe in pregnant woman with HNP at L-spine. But the rigorous studies will be needed to define clearly that oriental medical treatment is effective and safe in pregnant women with HNP at L-spine.

The Changes in Range of Motion after a Lumbar Spinal Arthroplasty with Charite$^{TM}$ in the Human Cadaveric Spine under Physiologic Compressive Follower Preload: A Comparative Study between Load Control Protocol and Hybrid Protocol

  • Kim, Se-Hoon;Chang, Ung-Kyu;Chang, Jae-Chil;Chun, Kwon-Soo;Lim, T. Jesse;Kim, Daniel H.
    • Journal of Korean Neurosurgical Society
    • /
    • v.46 no.2
    • /
    • pp.144-151
    • /
    • 2009
  • Objective: To compare two testing protocols for evaluating range of motion (ROM) changes in the preloaded cadaveric spines implanted with a mobile core type Charite$^{TM}$ lumbar artificial disc. Methods: Using five human cadaveric lumbosacral spines (L2-S2), baseline ROMs were measured with a bending moment of 8 Nm for all motion modes (flexion/extension, lateral bending, and axial rotation) in intact spine. The ROM was tracked using a video-based motion-capturing system. After the Charite$^{TM}$ disc was implanted at the L4-L5 level, the measurement was repeated using two different methods: 1) loading up to 8 Nm with the compressive follower preload as in testing the intact spine (Load control protocol), 2) loading in displacement control until the total ROM of L2-S2 matches that when the intact spine was loaded under load control (Hybrid protocol). The comparison between the data of each protocol was performed. Results: The ROMs of the L4-L5 arthroplasty level were increased in all test modalities (p < 0.05 in bending and rotation) under both load and hybrid protocols. At the adjacent segments, the ROMs were increased in all modes except flexion under load control protocol. Under hybrid protocol, the adjacent segments demonstrated decreased ROMs in all modalities except extension at the inferior segment. Statistical significance between load and hybrid protocols was observed during bending and rotation at the operative and adjacent levels (p< 0.05). Conclusion: In hybrid protocol, the Charite$^{TM}$ disc provided a relatively better restoration of ROM, than in the load control protocol, reproducing clinical observations in terms of motion following surgery.

Thermal-Induced Osteonecrosis of Adjacent Vertebra after Intradiscal Electrothermal Therapy

  • Kim, Soonjoon;Lee, Sun-Ho;Kim, Eun-Sang;Eoh, Whan
    • Journal of Korean Neurosurgical Society
    • /
    • v.60 no.1
    • /
    • pp.114-117
    • /
    • 2017
  • A 42-year-old man was admitted to our hospital with complaints of low back pain and intermittent right thigh pain. Twelve weeks before admission, the patient received intradiscal electrothermal therapy (IDET) at a local hospital. The patient still reported low back pain after the procedure that was managed with narcotic analgesics. Follow-up magnetic resonance imaging (MRI) was performed, and his referring physician thought the likely diagnosis was spondylodiscitis at the L4-5 spinal segment with a small epidural abscess. At admission to our department, the patient reported aggravated low back pain. Blood test results, including the erythrocyte sedimentation rate and C-reactive protein levels, were slightly elevated. Biopsy samples of the L4, L5 vertebral bodies and disk were obtained. The material underwent aerobic, anaerobic, fungal, mycobacterial cultures and histologic examination. Results of all cultures were negative. Histologically, necrosis of the bone was evident from the number of empty osteocyte lacunae. In addition, there was no evidence of infection based on biopsy results. No antibiotic treatment was administered on discharge. Repeat computed tomography and MRI performed 12 months after IDET showed a bony defect in the L4 and L5 vertebral bodies, and a decrease in the size of the L4-5 intervertebral disc lesion. We report a case of lumbar vertebral osteonecrosis induced by IDET and discuss etiology and radiologic features.

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Spinal Stability Evaluation According to the Change in the Spinal Fixation Segment Based on Finite Element Analysis (유한요소해석 기반 척추 고정분절 변화에 따른 척추 안정성 평가)

  • Kim, Cheol-Jeong;Son, Seung Min;Heo, Jin-Young;Lee, Chi-Seung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.3
    • /
    • pp.145-152
    • /
    • 2020
  • In this study, we evaluated spinal stability based on the change in the thoracolumbar fixation segment using finite element analysis (FEA). To accomplish this, a finite element (FE) model of a normal thoracolumbar spine (T10-L4), including intervertebral discs (IVD), ligaments, and facet joints, was constructed, and the material properties reported in previous studies were implemented. However, L1 was assumed as the lesion site, and three types of posterior fixation, namely, L1-L2, T12-L2, and T12-L1-L2, were implemented in the thoracolumbar FE model. In addition, the loading conditions for flexion, extension, lateral bending, and axial rotation were adopted. Through the series FEA, the deformation, equivalent stress, range of motion, and moment on the pedicle screws, vertebrae, and IVD were calculated, and the spinal stability was evaluated based on the FEA results.

Factors Influencing in the Bone Mineral Density and the Incidence of the Osteoporosis among Male Older than 40 Years Old (40세 이후 남성의 골밀도 관련 요인과 골다공증의 유병률)

  • Mo, Eun-Hee;Cho, Jung-Keun;Lee, Sang-Ho;Lim, Cheong-Hwan;Choi, JI-Won
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.10
    • /
    • pp.241-250
    • /
    • 2008
  • The interest in male osteoporosis is increasing as the incidence of osteoporotic fractures has increased not only in female but also in male due to the increase of old age population thanks to the development of medical science and science in general. Therefore, this study is to find factors related to bone mineral density of male older than 40 years old, to investigate the incidence of the male osteoporosis and to provide a basic result for prevention and medical treatment for the male osteoporosis. The incidence of the osteopenia and the osteoporosis at L-spine was 45% and 12.9% respectively and the incidence of them at femur was 51.9% and 7.63% respectively, among male older than 40 years old who took a medical examination. It was higher than the existing study results conducted to male older than 50 years old in USA and Europe. The incidence of them at both of L-spine and femur showed a significant difference depending the age groups. As the age increases, the average bone mineral density decreases at both of L-spine and femur. And as the weight increases and the body mass index is higher, the incidence of the osteoporosis decreases. There was no significant relation with the incidence of the osteoporosis depending on the exercise, the smoking and the drinking, but the number of exercise, smoking and drinking changes the quantity of bone and are factors influencing the bone mineral density of male person.

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF