• Title/Summary/Keyword: L-shaped plates

검색결과 28건 처리시간 0.021초

Shear and impact strength of waste plastic fibre reinforced concrete

  • Karanth, Savithri S;Ghorpade, Vaishali G;Rao, H Sudarsana
    • Advances in concrete construction
    • /
    • 제5권2호
    • /
    • pp.173-182
    • /
    • 2017
  • This paper is aimed at determining the shear and impact strength of waste plastic fibre reinforced concrete. M30 grade of concrete is prepared with waste plastic door fibres cut into 5 mm width and aspect ratios of 30, 50, 70, 90 and 110. Fibres are used in a volume fraction of 0 to 1.5% with an increment of 0.25%. L shaped specimens are cast for shear strength tests and flat plates of size $250{\times}250{\times}30mm$ are used for impact tests. "Drop ball method" is used for checking the impact strength. Shear strength is checked with L shaped specimens under UTM with a special attachment. It was found that up to 1.25% of waste plastic fibres can be effectively used for better strength of concrete both in shear and impact. Shear and impact strength were found to be increasing up to a volume fraction of fibres of 1.25%.

Comparison of Turkish Steel Building Specifications, TS 648 and SDCCSS 2018

  • Bozkurt, Mehmet Bakir;Ergut, Abdulkerim;Ozkilic, Yasin Onuralp
    • Steel and Composite Structures
    • /
    • 제45권4호
    • /
    • pp.513-533
    • /
    • 2022
  • This study presents similarities and differences between Turkish Building Code for Steel Structures, which are TS 648 and SDCCSS (Specification for Design, Calculation and Construction of Steel Structures) in terms of the design of the members. Hot-rolled I-shaped steel sections for symmetrical and U-shaped steel sections (i.e., channels) for monosymmetric sections were elaborated in detail. The design strength of tension members under tensile load, compression members under axial load and flexural members under flexure and shear were examined separately. Connection details for tension members, slenderness for compression members and distance between lateral supports for flexural members were considered as prime variables. Analysis results revealed the design strength of the tension members where at least one of the cross-sectional parts is not connected to the connection plates, I-shaped compression members where a slenderness ratio is below 39 (𝛌<39), U-shaped compression members and flexural members where Lb is between Lp and Lr (Lpb≤Lr) designed based on TS 648 are greater than those designed based on SDCCSS 2018. Strength differences between the specification can reach 79% for tensile members, 13% for compression members and 9% for flexural members.

Experimental seismic behaviour of L-CFST column to H-beam connections

  • Zhang, Wang;Chen, Zhihua;Xiong, Qingqing;Zhou, Ting;Rong, Xian;Du, Yansheng
    • Steel and Composite Structures
    • /
    • 제26권6호
    • /
    • pp.793-808
    • /
    • 2018
  • In this study, the seismic performance of the connections between L-shaped columns composed of concrete-filled steel tubes (L-CFST columns) and H-beams used in high-rise steel frame structures was investigated. Seven full-scale specimens were tested under quasi-static cyclic loading. The variables studied in the tests included the joint type, the axial compression ratio, the presence of concrete, the width-to-thickness ratio and the internal extension length of the side plates. The hysteretic response, strength degradation, stiffness degradation, ductility, plastic rotation capacity, energy dissipation capacity and the strain distribution were evaluated at different load cycles. The test results indicated that both the corner and exterior joint specimens failed due to local buckling and crack within the beam flange adjacent to the end of the side plates. However, the failure modes of the interior joint specimens primarily included local buckling and crack at the end plates and curved corners of the beam flange. A design method was proposed for the flexural capacity of the end plate connection in the interior joint. Good agreement was observed between the theoretical and test results of both the yield and ultimate flexural capacity of the end plate connection.

An investigation of anchorage to the edge of steel plates bonded to RC structures

  • Kara, M.E.;Firat, F.K.;Sonmez, M.;Karabork, T.
    • Steel and Composite Structures
    • /
    • 제22권1호
    • /
    • pp.25-43
    • /
    • 2016
  • This paper presents the results of an experimental study investigating the effects of anchorage systems used in externally bonded steel plates on the strength and ductility of reinforced concrete structures. In the literature, diagonal steel plates bonded to frames were designed to be more flexible than the connections to eliminate the possible effect of the connection flexibility. However, to better evaluate the performance of the strengthened structures, the strength and behavior of connections should also be considered. The purpose of this study was to experimentally investigate the effects of different connection types of steel plates bonded to the frame using anchors on the strengthened RC structures. For this purpose, eleven specimens were designed to simulate the interior and exterior connection behavior. Two of these were used as the control beams and remaining nine for the investigation of the functionality of the end steel plates. Experimental results show that the load carrying capacity of the strengthened beams is directly related to the connection types of the steel plates. For the interior connections, L-shaped end plates that were strengthened using steel anchors must have adequate stiffness to prevent its shape. While, for the exterior connections, the connection with three anchors carried more load than the other exterior connections.

수정 SPR 기법에 의한 휨을 받는 평판문제의 적응적 p-체눈 세분화 (p-Adaptive Mesh Refinement of Plate Bending Problem by Modified SPR Technique)

  • 조준형;이희정;우광성
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.481-486
    • /
    • 2007
  • The Zienkiewicz-Zhu(Z/Z) error estimate is slightly modified for the hierarchical p-refinement, and is then applied to L-shaped plates subjected to bending to demonstrate its effectiveness. An adaptive procedure in finite element analysis is presented by p-refinement of meshes in conjunction with a posteriori error estimator that is based on the superconvergent patch recovery(SPR) technique. The modified Z/Z error estimate p-refinement is different from the conventional approach because the high order shape functions based on integrals of Legendre polynomials are used to interpolate displacements within an element, on the other hand, the same order of basis function based on Pascal's triangle tree is also used to interpolate recovered stresses. The least-square method is used to fit a polynomial to the stresses computed at the sampling points. The strategy of finding a nearly optimal distribution of polynomial degrees on a fixed finite element mesh is discussed such that a particular element has to be refined automatically to obtain an acceptable level of accuracy by increasing p-levels non-uniformly or selectively. It is noted that the error decreases rapidly with an increase in the number of degrees of freedom and the sequences of p-distributions obtained by the proposed error indicator closely follow the optimal trajectory.

  • PDF

Experimental study on axial compressive behavior of welded built-up CFT stub columns made by cold-formed sections with different welding lines

  • Naghipour, Morteza;Yousofizinsaz, Ghazaleh;Shariati, Mahdi
    • Steel and Composite Structures
    • /
    • 제34권3호
    • /
    • pp.347-359
    • /
    • 2020
  • The objective of this study is to experimentally scrutinize the axial performance of built-up concrete filled steel tube (CFT) columns composed of steel plates. In this case, the main parameters cross section types, compressive strength of filled concrete, and the effect of welding lines. Welded built-up steel box columns are fabricated by connecting two pieces of cold-formed U-shaped or four pieces of L-shaped thin steel plates with continuous penetration groove welding line located at mid-depth of stub column section. Furthermore, traditional square steel box sections with no welding lines are investigated for the comparison of axial behavior between the generic and build-up cross sections. Accordingly, 20 stub columns with thickness and height of 2 and 300 mm have been manufactured. As a result, welding lines in built-up specimens act as stiffeners because have higher strength and thickness in comparison to the plates. Subsequently, by increasing the welding lines, the load bearing capacity of stub columns has been increased in comparison to the traditional series. Furthermore, for specimens with the same confinement steel tubes and concrete core, increment of B/t ratio has reduced the ductility and axial strength.

휨을 받는 L-형 평판의 적응적 세분화를 위한 선택적 p-분배 (The Selective p-Distribution for Adaptive Refinement of L-Shaped Plates Subiected to Bending)

  • 우광성;조준형;이승준
    • 한국전산구조공학회논문집
    • /
    • 제20권5호
    • /
    • pp.533-541
    • /
    • 2007
  • 계층적 p-세분화를 위해 Zienkiewicz-Zhu 오차평가법이 약간 수정되었으며, 이 방법의 유효성을 보이기 위해 휨을 받는 개구부를 갖는 Reinssner-Mindlin $C^{\circ}$-평판에 적용하였다. 유한요소해석상의 적응적 체눈을 결정하는 단계는 초수렴 팻취 복구기법에 기초를 둔 사후오차평가자와 연계된 p-세분화에 의해 제안되었다. 요소내의 변위장을 정의하기 위해 적분형 르장드르 고차 형상함수가 사용되는 반면 복구응력을 보간하기 위해 파스칼의 삼각수에 기초를 둔 같은 차수의 고차다항식이 사용되는 이유로 수정 Z/Z 오차평가는 종래의 방법과 다소 차이를 보여준다. 가우스 적분점에서의 응력을 최적화하기 위해 필요한 다항식으로 표현되는 응력함수를 얻기 위해 최소제곱법이 사용되었다. 고정된 요소망에 거의 최적의 형상함수 차수의 분배를 찾기 위한 전략이 논의되었는데, 허용되는 정확도를 얻을 수 있을 때까지 각 요소마다 형상함수의 차수를 불균등하게 증가시키는 방법으로, 소위 최적의 선택적 p-분배를 자동으로 결정하도록 되어있다. 위의 사항들을 L-형 평판 해석에 적용한 결과, 적응적 p-체눈설계 단계가 진행됨에 따라 자유도의 증가에 따라 오차량은 급격히 감소되는 것을 알 수 있었고, 제안된 오차 지시자에 의한 적응적 p-체눈 세분화는 최적 p-분배 진행방향에 근접하는 것을 볼 수 있었다.

A comparison of fixation methods using three-dimensional finite element analysis following anterior segmental osteotomy

  • Yun, Kyoung In;Park, Min-Kyu;Park, Myung-Kyun;Park, Je Uk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제38권6호
    • /
    • pp.332-336
    • /
    • 2012
  • Objectives: This study sought to evaluate fixation methods and determine the best method for the postoperative stabilization of maxillary osteotomy. For our analysis we performed a three-dimensional finite element analysis of stress distribution on the plate, screw, and surrounding bone, as well as displacement onto the plate. Materials and Methods: We generated a model using synthetic skull scan data; an initital surface model was changed to a solid model using software. Modified anterior segmental osteotomy (using Park's method) was made using the program, and four different types of fixation methods were used. An anterior load of 100 N was applied on the palatal surface of two central incisors. Results: The Type 1 (L-shaped) fixation method gave stresses of 187.8 MPa at the plate, 45.8 MPa at the screw, and 15.4 MPa at the bone around the plate. The Type 2 (I-shaped) fixation method gave stresses of 186.6 MPa at the plate, 75.7 MPa at the screw, and 13.8 MPa at the bone around the plate. The Type 3 (inverted L-shaped) fixation method gave stresses of 28.6 MPa at the plate, 29.9 MPa at the screw, and 15.3 MPa at the bone around the plate. The Type 4 (I-shaped) fixation method gave stresses of 34.8 MPa at the plate, 36.9 MPa at the screw, and 14.9 MPa at the bone around the plate. The deflection of the plates for the four fixation methods was 0.014 mm, 0.022 mm, 0.017 mm, and 0.018 mm, respectively. Conclusion: The Type 3 (inverted L-shaped) fixation method offers more stability than the other fixation methods. We therefore recommend this method for the postoperative stabilization of maxillary osteotomy.

'L'자형 Plate를 이용한 마이크로스트립 안테나의 소형화 (Miniaturization of Microstrip Antenna Using 'L' Shaped Plate)

  • 장연정;우종명
    • 한국전자파학회논문지
    • /
    • 제16권5호
    • /
    • pp.501-510
    • /
    • 2005
  • 본 논문에서는 마이크로스트립 패치 안테나의 패치 밑면에 부착된 'L'자형 plate에 의해 패치 밑면의 전류 경로 길이 증가 효과 및 perturbation효과를 이용하여 안테나의 소형화를 이루고자 하였다. 1.575 GHz대에 있어서, 먼저 대각선 급전 선형 편파의 경우, 14개의 'L'자형 Plate를 부착시켰을 시 패치의 크기가 $47mm{\times}47mm$로 높이 9mm 평면형 마이크로스트립 패치 안테나(패치 길이 83mm$\times$패치 폭 83mm)보다 $70.8\%$의 면적 축소 효과를 나타내었고, 이득은 1.19 dBd, E-면 HPBW는 $127^{\circ}$를 나타내었다. 또한 원형 편파의 경우, 13개의 'L'자형 plate를 부착시켰을 시 패치의 크기가 $53mm{\times}54mm$로, 평면형 보다 $54.6\%$ 면적 축소 효과를 나타내었고, 이득은 1.36 dBd, 1.575 GHz에서 축비는 1.37 dB, 축비 2 dB 이하 대역폭은 14 MHz를 나타내었다. 이로써 본 논문에서 제안된 패치 밑면에 'L'자형 plate를 부착시킨 마이크로스트립 안테나가 선형 편파 및 원형 편파 안테나의 소형화에 적합함을 확인하였다.

Reissner-Mindlin 평판의 hp-Version 유한요소해석 (hp-Version of the Finite Element Analysis for Reissner-Mindlin Plates)

  • 우광성;이기덕
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1992년도 가을 학술발표회 논문집
    • /
    • pp.39-44
    • /
    • 1992
  • This paper is concerned with formulations of the hierarchical $C^{o}$-plate element on the basis of Reissner-Mindlin plate theory. On reason for the development of the aforementioned element is that it is still difficult to construct elements based on h-version concepts which are accurate and stable against the shear locking effects. An adaptive mesh refinement and selective p-distribution of the polynomial degree using hp-version of the finite element method we proposed to verify the superior convergence and algorithmic efficiency with the help of the clamped L-shaped plate problems.s.

  • PDF