• 제목/요약/키워드: L-probe

검색결과 405건 처리시간 0.031초

비접촉식 진동 변위센서의 특성에 관한 연구 (Study on characteristics of noncontact vibrating displacement sensor)

  • 조철환;조성태;양경현
    • 동력기계공학회지
    • /
    • 제15권2호
    • /
    • pp.13-18
    • /
    • 2011
  • This thesis is about the result of conducting a specific experiment for the development of noncontact vibration displacement sensor for measuring the spindle vibration that is used for conditional monitoring of machinery. One should be careful when using the eddy current type displacement sensor because the sensitivity of it is different according to the quality of the material. While the probe used for nondestructive inspection adopts the effect of transmitting the material by using the high frequency domain, the eddy current type displacement sensor uses the lower frequency of around 1MHz. Also, while the nondestructive probe uses the method of enhancing output by using the resonance zone, the vibration displacement sensor utilizes the stable zone by avoiding the resonance zone. Since the oscillator of the converter uses the "L" element as Probe, its characteristic changes with the variation of a relevant impedance. In other words, if the length of Probe's Cable gets extended (Impedance increase), the sensitivity declines accordingly. The effect of surrounding temperature was small, but the influence of the quality of Sensor Coil used was high. Moreover, following an experimental demonstration of the phenomenon where the sensitivity decreases as the frequency of the tested material increases from a frequency response test, the maximum frequency that could be measured was approximately 1KHz. It was noted that the degree of precision could be maintained by using the gap of the probe in the linear zone at the installation site.

Probe-based qPCR Assay for Rapid Detection of Predominant Candida glabrata Sequence Type in Korea

  • Bae, Jinyoung;Lee, Kyung Eun;Jin, Hyunwoo
    • 대한의생명과학회지
    • /
    • 제25권4호
    • /
    • pp.407-416
    • /
    • 2019
  • Recent years have seen an increase in the incidence of candidiasis caused by non-albicans Candida (NAC) species. In fact, C. glabrata is now second only to C. albicans as the most common cause of invasive candidiasis. Therefore, the rapid genotyping specifically for C. glabrata is required for early diagnosis and treatment of candidiasis. A number of genotyping assays have been developed to differentiate C. glabrata sequence types (STs), but they have several limitations. In the previous study, multi-locus sequence typing (MLST) has performed with a total of 101 C. glabrata clinical isolates to analyze the prevalent C. glabrata STs in Korea. A total of 11 different C. glabrata STs were identified and, among them, ST-138 was the most commonly classified. Thus, a novel probe-based quantitative PCR (qPCR) assay was developed and evaluated for rapid and accurate identification of the predominant C. glabrata ST-138 in Korea. Two primer pairs and hybridization probe sets were designed for the amplification of internal transcribed spacer 1 (ITS1) region and TRP1 gene. Analytical sensitivity of the probe-based qPCR assay was 100 ng to 10 pg and 100 ng to 100 pg (per 1 μL), which target ITS1 region and TRP1 gene, respectively. This assay did not react with any other Candida species and bacteria except C. glabrata. Of the 101 clinical isolates, 99 cases (98%) were concordant with MLST results. This novel probe-based qPCR assay proved to be rapid, sensitive, highly specific, reproducible, and cost-effective than other genotyping assay for C. glabrata ST-138 identification.

사과 바이러스 검정을 위한 SYBR Green I 및 TaqMan probe 기반의 real-time PCR 검사법 개발 (Development of Real-time Quantitative PCR Assay based on SYBR Green I and TaqMan Probe for Detection of Apple Viruses)

  • 허성;정용석
    • 한국작물학회지
    • /
    • 제65권4호
    • /
    • pp.496-507
    • /
    • 2020
  • 본 연구는 사과 바이러스 ASGV, ASPV 및 ApMV를 각각 정밀하게 진단하고자 SYBR Green I 및 TaqMan probe, 두 종류의 다른 chemical dye를 사용하여 quantitative real-time PCR 검정법을 개발하고자 하였다. 1. 사과 바이러스 ASGV, ASPV 및 ApMV의 국내분리주를 바탕으로 하여 cloning 및 in vitro transcription을 수행해 10배 희석단위 표준시료를 제작하였다. 각 바이러스에 대한 SYBR Green I용 프라이머와 TaqMan probe용 프라이머 및 프로브를 디자인하였다. 2. 상기 제작된 프라이머와 프로브를 이용해 표준시료를 대상으로 real-time PCR을 수행하여 각 바이러스의 증폭곡선과 검량선을 구할 수 있었다. Real-time PCR 결과, SYBR Green I기반의 검정법은 TaqMan probe기반의 검정법 못지 않은 결과를 보여주었으며, 적은 비용에 대량 검정이 요구되는 곳에 효과적으로 응용될 수 있을 것이다. 3. 현장평가를 본 실험에서 개발된 TaqMan probe기반의 real-time PCR검정법과 기존의 RT-PCR검정법과 비교분석하였다. 그 결과 real-time PCR 검정법은 singleplex 및 multiplex RT-PCR보다 더 민감하고 정확한 결과를 내어 RT-PCR로 검출할 수 없는 농도까지 검정할 수 있음을 입증하였다. 4. 본 실험에서 개발한 real-time PCR검정법은 검역현장과 같은 대량의 검사가 요구되는 곳에서는 SYBR Green I 기반의 검정법을, 바이러스 연구분야에서는 세밀한 정량이 가능한 TaqMan probe 방식의 검정법이 활용될 것으로 기대한다.

표면 근전도와 전기 탐침기를 이용한 상완이두근의 운동점 표지 비교 연구 (Comparison Study about Surface Mapping of Motor Points in Biceps Brachii Muscle Using Surface EMG and Electric Probe)

  • 박재원;금동호
    • 한방재활의학과학회지
    • /
    • 제28권1호
    • /
    • pp.85-96
    • /
    • 2018
  • Objectives This study was performed to compare the electrical methods of motor points mapping using surface EMG and electric probe (Pointer Excel II). Methods 32 healthy adults (male 16, female 16) were selected. and classified into two groups; surface EMG group, electric probe (Pointer Excel II) group. In surface EMG group, motor points were searched by recoding the compound muscle potentials. In electric probe (Pointer Excel II) group, motor points were searched by scanning the skin with Pointer Excel II at low level stimulation. The locations of the motor points were expressed as X and Y values in relation to the reference line. The horizontal reference line was set as elbow crease and the vertical reference line was set as the line connecting coracoid process to the center of the horizontal reference line. The data was analyzed by 'Independent T-test' and 'equivalence test'. Results 1. The motor points of short head and long head of biceps brachii muscle were located at about 2/3 length of the vertical reference line from coracoid process and about 1/5~1/4 length of the half of the horizontal reference line from the vertical reference line in both group. 2. The motor points of the short head were located more distally and close to the vertical reference line (p<0.001). 3. In surface EMG group, the motor points of the long head were located more laterally in the female than male. And the motor points of the long head were located more distally in the left side than right side (p<0.05). In electric probe (Pointer Excel II) group, similar tendency was observed but there was no statistically significant difference (p>0.05). 4. As a result of the equivalence test between surface EMG group and electric probe (Pointer Excel II) group, the confidence intervals of the difference were within the equivalence limit. Therefore, the locations of the motor points searched by two ways are equa l (p>0.05, equivalence interval=3%). Conclusions The results indicate that electric probe (Pointer Excel II) can be used to search the motor points instead of surface EMG. This might improve the clinical efficiency when using the motor points to treat muscle dysfunction.

고려인삼(Panax ginseng C.A. Meyer) Ribulose-1,5-bisphosphate Carboxylase/oxygenase Large Subunit(rbct) Gene의 Cloning (Cloning of Ribulose-1,5-bisphosphate Carboxylase/oxygenase Large Subunit(rbcL) Gene from Korean Ginseng (Panax ginseng C.A. Meyer))

  • 이정헌;임용표
    • Journal of Ginseng Research
    • /
    • 제19권1호
    • /
    • pp.51-55
    • /
    • 1995
  • The DNA fragment containing ginseng ribulose-1,5-bisphosphate carboxytase/oxygenase large subunit(rbcL) gene was cloned from the ginseng chloroplast EcoRl library by colony lift hybridization with tobacco rbcL gene probe. From the screened clone, the DNA fragment containing ginseng rbcL gene was digested with several restriction enzyme and analyzed by Southern blot hybridization for the construction of restriction map. The ginseng rbcL gene fragment was subcloned in pBluescript II SK + vector and sequence analysis was performed. The nucleotide sequence of ginseng rbcL gene was compared with those of petunia, tobacco, alfalfa, rice and barley, which showed a homology of 93.1%, 95.2%, 90.5%, 85.5% and 84.3%, respectively.

  • PDF

두 입력단자를 갖는 이중대역 이중편파 마이크로스트립 패치 안테나 설계 (Design of Dual-Band, Dual-Polarized Microstrip Patch Antenna with Two Input Ports)

  • 정해영;이광천;이성준;최익권
    • 한국전자파학회논문지
    • /
    • 제16권11호
    • /
    • pp.1164-1170
    • /
    • 2005
  • 본 논문은 두 개의 프로브 급전 단자만을 갖는 이중대역 이중 편파 마이크로스트립 패치 안테나를 제시한다. 급전 단자간 격리도와 교차 편파를 개선하기 위하여 패치와 급전 프로브간에 고리 모양 간격(annular gap)을 갖는 급전 구조를 설계하였으며, 제작된 안테나의 두 급전 단자간 격리도와 교차 편파는 반사 손실이 -10 dB 이하인 $1.84\;GHz\~l.93\;GHz$대역에서 각각 21 dB 이상, 22.2 dB 이상 그리고 $2.62\;GHz\~2.81\;GHz$ 대역에서는 각각 27 dB 이상, 19 dB 이상으로 우수한 급전 단자간 격리도와 교차 편파 특성을 가짐을 측정을 통해 확인하였다. 이득은 각 주파수 대역에서 약 6.9 dBi이다.

Pathogen-Imprinted Polymer Film Integrated probe/Ti3C2Tx MXenes Electrochemical Sensor for Highly Sensitive Determination of Listeria Monocytogenes

  • Xiaohua, Jiang;Zhiwen, Lv;Wenjie, Ding;Ying, Zhang;Feng, Lin
    • Journal of Electrochemical Science and Technology
    • /
    • 제13권4호
    • /
    • pp.431-437
    • /
    • 2022
  • As one of the most hazardous and deadliest pathogens, Listeria monocytogenes (LM) posed various serious diseases to the human being, thus designing effective strategy for its detection is of great significance. In this work, by preparing Ti3C2Tx MXenes nanoribbon (Ti3C2TxR) as carrier and selecting thionine (Th) acted simultaneously as signal probe and functional monomer, a LM pathogen-imprinted polymers (PIP) integrated probe electrochemical sensor was design to monitor LM for the first time, that was carried out through the electropolymerization of Th on the Ti3C2TxR/GCE surface in the existence of LM. Upon eluting the templates from the LM imprinted cavities, the fabricated PIP/Ti3C2TxR/GCE sensor can rebound LM cells effectively. By recording the peak current of Th as the response signal, it can be weakened when LM cell was re-bound to the LM imprinted cavity on PIP/Ti3C2TxR/GCE, and the absolute values of peak current change increase with the increasement of LM concentrations. After optimizing three key parameters, a considerable low analytical limit (2 CFU mL-1) and wide linearity (10-108 CFU mL-1) for LM were achieved. In addition, the experiments demonstrated that the PIP/Ti3C2TxR sensor offers satisfactory selectivity, reproducibility and stability.

Dynamics of All-Optical Switching in Bacteriorhodopsin and its Application to Optical Computing

  • Singh, C.P.;Roy, Sukhdev
    • Journal of Photoscience
    • /
    • 제9권2호
    • /
    • pp.317-319
    • /
    • 2002
  • All-optical switching has been demonstrated in bacteriorhodopsin (bR) based on nonlinear intensity induced excited state absorption. The transmission of a cw probe laser beam at 410 nm corresponding to the peak absorption of M state through a bR film is switched by a pulsed pump laser beam at 570 nm that corresponds to the maximum initial 8 state absorption. The switching characteristics have been analyzed using the rate equation approach considering all the six intermediate states (B, K, L, M, N and 0) in the bR photocycle. The switching characteristics are shown to be sensitive to life time of the M state, absorption cross-section of the 8 state at probe wavelength ($\sigma$ $\_$Bp/) and peak pump intensity. It has been shown that the probe laser beam can be completely switched off (100 % modulation) by the pump laser beam at relatively low pump powers, for $\sigma$$\_$Bp/ = O. The switching characteristics have been used to design all-optical NOT, OR, AND and the universal NOR and NAND logic gates for optical computing with two pulsed pump laser beams.

  • PDF

Nanomanipulation and Nanomanufacturing based on Ion Trapping and Scanning Probe Microscopy (SPM)

  • Kim, Dong-Whan;Tae, Won-Si;Yeong, Maeng-Hui;K. L. Ekinci
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.530-537
    • /
    • 2004
  • Development of a versatile nanomanipulation tool is an overarching theme in nanotechnology. Such a tool will likely revolutionize the field given that it will enable fabrication and operation of a wealth of interesting nanodevices. This study seeks funding to create a novel nanomanipulation system with the ultimate goal of using this system for nanomanufacturing at the molecular level. The proposed design differs from existing approaches. It is based on a nanoscale ion trap integrated to a scanning prove microscope (SPM) tip. In this design, molecules to be assembled will be ionized and collected in the nanoscale ion trap all in an ultra high vacuum (UHV) environment. Once filled with the molecular ions, the nanoscale ion trap-SPM tip will be moved on a substrate surface using scanning probe microscopy techniques. The molecular ions will be placed at their precise locations on the surface. By virtue of the SPM, the devices that are being nanomanufactured will be imaged in real time as the molecular assembly process is carried out. In the later stages, automation of arrays of these nanomanipulators will be developed.

  • PDF

Detection of Deep Subsurface Cracks in Thick Stainless Steel Plate

  • Kishore, M.B.;Park, D.G.;Jeong, J.R.;Kim, J.Y.;Jacobs, L.J.;Lee, D.H.
    • Journal of Magnetics
    • /
    • 제20권3호
    • /
    • pp.312-316
    • /
    • 2015
  • Unlike conventional Eddy Current Test (ECT), Pulsed Eddy Current (PEC) uses a multiple-frequency current pulse through the excitation coil. In the present study, the detection of subsurface cracks using a specially designed probe that allows the detection of a deeper crack with a relatively small current density has been attempted using the PEC technique. The tested sample is a piece of 304 stainless steel (SS304) with a thickness of 30mm. Small electrical discharge machining (EDM) notches were put in the test sample at different depths from the surface to simulate the subsurface cracks in a pipe. The designed PEC probe consists of an excitation coil and a Hall sensor and can detect a subsurface crack as narrow and shallow as 0.2 mm wide and 2 mm deep. The maximum distance between the probe and the defect is 28 mm. The peak amplitude of the detected pulse is used to evaluate the cracks under the sample surface. In time domain analysis, the greater the crack depth the greater the peak amplitude of the detected pulse. The experimental results indicated that the proposed system has the potential to detect the subsurface cracks in stainless steel plates.