• Title/Summary/Keyword: L-function

Search Result 3,802, Processing Time 0.03 seconds

Quality Characteristics of Dumpling Shell Containing Pleurotus eryngii Powder (새송이버섯 분말을 첨가한 만두피의 품질 특성)

  • Kang, Bok-Hee;Shin, Eun-Jeong;Lee, Sang-Han;Lee, Dong-Sun;Hur, Sang-Sun;Kim, Seong-Ho;Son, Seok-Min;Lee, Jin-Man
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.4
    • /
    • pp.570-574
    • /
    • 2011
  • This study was conducted to investigate the quality characteristics of dumpling shells with added Pleurotus eryngii powder (PP) (2%, 4%, 6%). The weight after cooking and volume of the dumpling shells increased with the addition of PP. The water absorption of the dumpling shells was not significantly different by the addition of PP. Turbidity after cooking increased and hardness decreased by adding PP. The L value after cooking decreased with the addition of PP, and the b value was highest when the content of PP was 6%. Adhesiveness increased by adding PP and springiness decreased when PP content was above 4%. Chewiness and gumminess decreased by adding the powder. There were no differences among the control, 2%, and 4% samples in cohesiveness values, but cohesiveness significantly decreased with the addition of 6% of powder. Color characteristics showed low values when PP was added at more than 6% according to sensory characteristics tests. No significant differences were found in flavor, taste, smoothness, moisture, or adhesiveness of the dumpling shells after cooking according to additions of PP. Chewiness was higher by adding PP compared to the control, but no significant differences were found by additions of PP.

Porewater Pressure Predictions on Hillside Slopes for Assessing Landslide Risks (II) Development of Groundwater Flow Model (산사태 위험도 추정을 위한 간극수압 예측에 관한 연구(II) -산사면에서의 지하수위 예측 모델의 개발-)

  • Lee, In-Mo;Park, Gyeong-Ho;Im, Chung-Mo
    • Geotechnical Engineering
    • /
    • v.8 no.2
    • /
    • pp.5-20
    • /
    • 1992
  • The physical-based and lumped-parameter hydrologic groundwater flow model for predicting the rainfall-triggered rise of groundwater levels in hillside slopes is developed in this paper to assess the risk of landslides. The developed model consists of a vertical infiltration model for unsaturated zone linked to a linear storage reservoir model(LSRM) for saturated zone. The groundwater flow model has uncertain constants like soil depttL slope angle, saturated permeability, and potential evapotranspiration and four free model parameters like a, b, c, and K. The free model parameters could be estimated from known input-output records. The BARD algorithm is uses as the parameter estimation technique which is based on a linearization of the proposed model by Gauss -Newton method and Taylor series expansion. The application to examine the capacity of prediction shows that the developed model has a potential of use in forecast systems of predicting landslides and that the optimal estimate of potential 'a' in infiltration model is the most important in the global optimum analysis because small variation of it results in the large change of the objective function, the sum of squares of deviations of the observed and computed groundwater levels. 본 논문에서는 가파른 산사면에서 산사태의 발생을 예측하기 위한 수문학적 인 지하수 흐름 모델을 개발하였다. 이 모델은 물리적인 개념에 기본하였으며, Lumped-parameter를 이용하였다. 개발된 지하수 흐름 모델은 두 모델을 조합하여 구성되어 있으며, 비포화대 흐름을 위해서는 수정된 abcd 모델을, 포화대 흐름에 대해서는 시간 지체 효과를 고려할 수 있는 선형 저수지 모델을 이용하였다. 지하수 흐름 모델은 토층의 두께, 산사면의 경사각, 포화투수계수, 잠재 증발산 량과 같은 불확실한 상수들과 a, b, c, 그리고 K와 같은 자유모델변수들을 가진다. 자유모델변수들은 유입-유출 자료들로부터 평가할 수 있으며, 이를 위해서 본 논문에서는 Gauss-Newton 방법을 이용한 Bard 알고리즘을 사용하였다. 서울 구로구 시흥동 산사태 발생 지역의 산사면에 대하여 개발된 모델을 적용하여 예제 해석을 수행함으로써, 지하수 흐름 모델이 산사태 발생 예측을 위하여 이용할 수 있음을 입증하였다. 또한, 매개변수분석 연구를 통하여, 변수 a값은 작은 변화에 대하여 목적함수값에 큰 변화를 일으키므로 a의 값에 대한 최적값을 구하는 것이 가장 중요한 요소라는 결론을 얻었다.

  • PDF

Dermal Absorption and Body Distribution of $^{125}I-rhEGF$ in Hairless Mice (헤어리스마우스 피부 국소에 적용된 $^{125}I-rhEGF$의 피부흡수 및 체내 분포)

  • Lee, Jeong-Uk;Chung, Seok-Jae;Lee, Min-Hwa;Shim, Chang-Koo
    • YAKHAK HOEJI
    • /
    • v.41 no.6
    • /
    • pp.737-748
    • /
    • 1997
  • Distribution of rhEGF in the skin, plasma and several organ tissues following topical application of $^{125}I-rhEGF$ (0.4${\mu}$Ci) solution in 25% Pluronic F-127 on 154$mm^2$ normal and damaged (burned and stripped) skins of hairless mice was examined. The radioactivity in the stripped skin tissues increased as a function of time, and was 10-20 times higher than that in the normal and burned skins. The fractions of intact drug in the skin tissues were 40-60% for the normal and burned skins, and 60-80% for the stripped skin. It indicates that the stratum corneum layer behaves as a barrier for the dermal penetration of the drug. The radioactivity in the plasma was much higher for the stripped skin than for the normal and burned skins. However, the concentration of intact drug in the stripped skin was comparable to those in the normal and burned skins indicating most severe degradation (or metabolism) of the drug in the stripped skin. As a result, the fraction of intact drug in the plasma was lowest for the stripped skin (<10%). Body organ distribution of the drug was much higher for the stripped skin. The concentration in the stomach. Both in total radioactivity and intact drug, showed more than 10-times higher value than in the other organs (liver, kidney and spleen). The fraction of intact drug in each organ tissue was below 10-20%. And generally lowest for the stripped skin. The lowest fraction of the drug for the stripped skin could not be explained by the activity of the aminopeptidases in the skin since it was lower for the stripped skin than for the normal skin. Thereover, the fraction of intact drug appears to be determined by the balance between dermal uptake and systemic elimination of the drug, for example. The mechanism of dermal uptake of rhEGF was examined by topical applying 200${\mu}$l of 25% Pluronic F-127 solution containing 0.4 ${\mu}$Ci of $^{125}I-rhEGF$ and 0.14${\mu}$Ci of $^{14}C$-inulin (a marker of passive diffusion). The radioactivity of $^{125}I-rhEGF$ at each sampling time point (0.5, 1, 2, 4 and 8hr) was correlated (p<0.05) with the corresponding radioactivity of $^{14}C$-inulin. It appears to indicate the rhEGF may be uptaken into the skins mainly by the passive diffusion. This hypothesis was supported by the constant specific binding of EGF to the skin homogenates regardless of the skin models. Receptor mediated endocytosis (RME) appears to contribute negligibly, if any, to the overall uptake process.

  • PDF

Thermal and chemical stability evaluation of white ceramic pigment for digital inkjet printing (디지털 잉크젯 프린팅용 흰색 세라믹 안료의 고온 및 화학적 안정성 평가)

  • Kwon, Jong-Woo;Lee, Ji-Hyeon;Lee, Jong-Heun;Hwang, Kwang-Taek;Kim, Jin-Ho;Han, Kyu-Sung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.5
    • /
    • pp.201-208
    • /
    • 2016
  • Ceramic pigments, which show good thermal and chemical stabilities, have been applied for various industry with development of digital printing technology. Ceramic inkjet printing has advantages of high efficiency of ink usage and eco-friendly process. Thus, the interest of the ceramic pigments with various function and color including CMYK (cyan, magenta, yellow, black) digital primary color is increasing. Here, we investigated the thermal and chemical stabilities of white ceramic pigment for digital inkjet printing process. The microstructure and crystal structure of MgO, $Al_2O_3$, $MgAl_2O_4$, $CeO_2$ were analyzed, and the stability with glaze were evaluated. In order to evaluate the applicability for digital inkjet printing, the chemical stability of white ceramic pigments at high temperature was investigated by characterization of the mixed color properties with CMYK ceramic pigments after firing process.

External Morphology of the American Leafminer, Liriomyza trifolii (Diptera: Agromyzidae), on Tomato with Scanning Electron Microscope (주사전자현미경을 이용한 토마토에 발생하는 아메리카잎굴파리(Liriomyza trifolii)의 외부형태적 특징)

  • Youn, Young-Nam;Kim, Ki-Duck;Park, Su-Jin;Kim, Nam-Sung;Seo, Mi-Ja;Chae, Soon-Yong
    • Korean Journal of Agricultural Science
    • /
    • v.27 no.1
    • /
    • pp.13-19
    • /
    • 2000
  • The external morphology of male and female of Liriomyza trifolii (Burgess) was studied using the scanning electron microscopy (SEM). Three types of sensilla were identified on the funicle of antennae. The trichoid sensilla were most conspicious and distributed with a characteristic sharp structure at the apical end. Basiconic sensilla were showed distal curvature about $13{\mu}m$ long and $1.2{\mu}m$ to $1.4{\mu}m$ in diameter. Grooved sensilla were showed a finger-like projections at the peg apex. The function of these sensilla likely to be olfactory. The mouthparts were adapted for sucking food, and formed a elongate rostrum which was incorporated with labrum. The labrum was a small and flap-like shape. The slender and paired maxillary palp seemed to combine with each other lengthwise to long tube. The tarsus typically consisted of 5 segments, which might be variously modified, principally by thickening or flattening. The segment beared a pair of claws. Beneath the claws, there was a pair of pad-like pulvillia and a bristle-like median empodium. L. trifolii might secreted on the pulvillus and empodium an adhesive substance that enable them to cling to smooth surfaces. Male terminalia was complicated. The name 'aedeagus' seemed the best available general term for the copulatory organ, otherwise, female terminalia was usually relatively simple. This structure was reduced and formed a telescopic, eversible, and tubular ovipositor.

  • PDF

Expression of Intercellular Adhesion Molecule-1 in Human Idiopathic Pulmonary Fibrosis (인체 특발성 폐섬유증에서 Intercellular Adhesion Molecule-1의 발현에 관한 연구)

  • Park, Sung-Soo;Shin, Dong-Ho;Kim, Tae-Wha;Lee, Dong-Hoo;Lee, Jung-Hee;Lee, Jung-Dal
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.185-191
    • /
    • 1993
  • Background: Intercellular adhesion molecule-1(ICAM-1) is a 90 kD surface glycoprotein, associated with ${\alpha}_L{\beta}_2$ and ${\alpha}_M{\beta}_2$ subunit of integrins, that serve as cell-cell and cell-substratum adhesion molecules and help regulate cellular morphology, differentiation, and proliferation. The adhesion molecules likely play important roles in maintaining the normal structure and function of the lung. ICAM-1 system among many cell adhesion molecules is importantly issuing in the pathogenesis of idiopathic pulmonary fibrosis. Methods : By using $IgG_1$ monoclonal antibody for ICAM-1, we investigated immunohistochemically the expression of ICAM-1 in the formalin-fixed, paraffin-embedded tissue sections of the 3 normal cases and 6 pieces of tissues taken 3 cases with idiopathic pulmonary fibrosis. Results : In the 3 normal cases, the expressions of ICAM-1 were not discernible. Up-regulation of the ICAM-1 expression was showed in the interstitial fibroblast cells of alveolar septa in 5 pieces and proliferated alveolar pneumocytes in 1 piece among 6 pieces of tissues taken 3 cases with idiopathic pulmonary fibrosis. Conclusion : It was concluded from these findings that up-regulation of the ICAM-1 expression may be related to pathogenesis of idiopathic pulmonary fibrosis.

  • PDF

Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis (지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향)

  • Park, Hyun-Soo;Lim, Sung-Bin;Chung, Chin-Hyung;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.2
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

A Study of Safflower Seed Extracts on Bone Formation in Vitro (홍화인 추출물이 골 형성에 미치는 영향에 관한 실험실적 연구)

  • Lee, Seong-jin;Choi, Ho-Chul;Sun, Ki-Jong;Song, Jae-Bong;Pi, Sung-Hee;You, Hyung-Keun;Shin, Hyung-Shik
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.461-474
    • /
    • 2005
  • The ultimate goal of periodontal therapy is the regeneration of periodontal tissue and the repair of function. For more than a decade there have been many efforts to develop materials and methods of treatment to promote periodontal tissue regeneration. Recently many efforts are concentrated on the regeneration potential of material used in traditional medicine. Safflower(Carthamus tinctorius L.) seed extract(SSE) have long clinically used in Korea to promote bone formation and prevent osteoporosis. The purpose of this study was to examine the effects of SSE on bone formation in human osteoblastic cell line. Human fetal osteoblastic cell line(hFOB 1.19) was cultured with DMEM and SSE($1{\mu}g/ml$, $10{\mu}g/ml$, $100{\mu}g/ml$, $1mg/ml$) at $34^{\cdot}C$ with 5% $CO_2$ in 100% humidity. The proliferation, differentiation of the cell was evaluated by several experiments. Cell proliferation was significantly increased at $10{\mu}g/ml$, $100{\mu}g/ml$, 1mg/ml of SSE after 3 and 7 days incubation(p<0.05). Cell spreading assay was significantly increased at $100{\mu}g/ml$ of SSE after 3 days and $1{\mu}g/ml$, $10{\mu}g/ml$, $100{\mu}g/ml$, 1mg/ml of SSE after 7 days(p<0.05). Alkaline Phosphatase(ALP) level was significantly increased in $10{\mu}g/ml$, $100{\mu}g/ml$, 1mg/ml of SSE(p<0.05). Collagen synthesis was significantly increased at $10{\mu}g/ml$, $100{\mu}g/ml$, 1mg/ml of SSE(p<0.05). A quantified calcium accumulation was significantly increased at $10{\mu}g/ml$, $100{\mu}g/ml$ of SSE(p<0.05). ALP and osteocalcin mRNA was expressed in $100{\mu}g/ml$ of SSE by RT-PCR. These results indicate that SSE are capable of increasing osteoblasts mineralization and may play an important role in bone formation.

Photoelastic Stress Analysis of Fixed Partial Dentures (가공의치(架工義齒)에 작용(作用)하는 Stress에 관(關)한 광탄성학적(光彈性學的) 분석(分析))

  • Cho, Won-Haeng
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.18 no.1
    • /
    • pp.15-35
    • /
    • 1980
  • The purpose of this study was to investigate stresses in the various components of fixed partial dentures restoring the posterior teeth of the lower jaw, and to measure quantitatively the effects of certain modifications in structural design on the stresses in the restorations using two-dimensional photoelasticity. Two-dimensional photoelastic methods were used in this study. Several models of fixed partial dentures were constructed. Shoulder less margins and anatomic occlusal reduction were incorporated in Model 1. Rounded shoulders and flat occlusal reduction were incorporated in Model 2, while Model 3 was a cantilever fixed partial denture. Other similar fixed partial dentures were constructed with V and U notches deliverately included in the region of the fixed joints for comparative reasons. The birefringent materials used in this study were PSM-1 and PSM-5 in standard sheets. PSM-1 was used for constructing the substructure, and PSM-5 was used in making the components of the fixed partial dentures. The two materials were used in the construction of composite photoelastic models. Improved artificial stone was used to represent dental cement in luting the composite photoelastic models. Static loading procedures were used at preplanned sites to represent occlusal loads in the mouth. 35 mm color and B/W film were used to record isochromatics in accordance with photoelastic procedures. Data reduction was performed using the grid method, which helped in, the mathematical integration procedure (Shear difference method) to separate the principal stresses. The results were as follows. 1. Fixed partial dentures do not function in bending as a symmetrical beam. Alternate areas of tension and compression were demonstrated when multiple contact loading was used. 2. The weakest part in posterior fixed partial dentures is the fixed joint. 3. (1) Models I and modified Model I were loaded on the pontic using a 50 pound vertical static load. The shear stress near the posterior fixed joint in Model 1 (U notches) was+129.4 p.s.i., and at the same fixed joint in modified Model 1 (V notches) was+239.4 p.s.i. The concentration of stress in fixed joint was reduced by 50% when U notches replaced the V notches. (2) Modified Model 2 was loaded using a multiple contact loader at a total load of 125 pounds. The difference between the principal stresses (${\sigma}_1-{\sigma}_2$), shear stress, at the V notches was+600 p.s.i., and at the U notches was+3l7 p.s.i. The shear stress was reduced by 50% when U notches replaced the V notches. V-grooves at the fixed joints should be avoided, and should be replaced by regular shaped U-grooves. 4. Cantilever fixed partial dentures had much higher stresses at the fixed joint than fixed partial dentures that were attached at both ends.

  • PDF

Flexual strength of resins for provisional fixed prostheses (임시 고정성 보철물 제작용 레진의 굽힘강도)

  • Choi, Myoung-Ah;Ahn, Seung-Geun;Cho, Kuk-Hyeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.16 no.3
    • /
    • pp.221-227
    • /
    • 2000
  • Provisional fixed partial dentures(FPDs) are an important part of many prosthodontic treatment procedures. These provisional fixed prostheses must fulfill biologic, mechanical, and esthetic requirements to be considered successful. Consideration of all these factors and requirements are important because provisional resin restorations may be worn over a long period to assess the results of periodontal and endodontics therapies, and also during the restorative phase of implant reconstructive procedures. This in vitro study examined flexual strength of four resins commonly used for fixed provisional prostheses. The effects of polymerization conditions were also evaluated. The four resins tested were : Caulk Temporary bridge resin(L.D. Caulk Co. Dentsply International Millford), Jet(Lang Dental Mfg. Co. Chicago. ILL. U.S.A), Alike (Coe Laboratories. Inc. Chicago. ILL. U.S.A) and Tokuso Curefast (Coe Laboratories. Inc. Chicago. ILL. U.S.A) The test specimens were 65mm long, 14mm wide, and 3.5mm thickness. 10 specimens of four resins were cured for 15 minutes at atmospheric pressure and 10 specimens of four resins were cured at an additional pressure of approximately 20 psi. A total of 80 specimens were prepared. The flexual strength was determined by three-point bending test. Data were analysed with the Paired samples T-test and Tukey student-range test Within the limitations imposed in this study, the following conclusions can be drawn : 1. Under the condition of bench curing, Caulk Temporary bridge resin showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Jet, Tokuso Curefast, Alike, and Caulk Temporary bridge resin demonstrated significantly higher strength than other resins. 2. Under the condition of pressure curing, Jet showed the highest flexual strength. In decreasing order, the flexual strength of the other materials was as follows : Caulk Temporary bridge resin, Tokuso Curefast, and Alike. There were all statistically significant differences among four resins 3. There was a statistically significant difference between bench- and pressure-cured specimens in all four materials.

  • PDF