• Title/Summary/Keyword: L-filter

Search Result 1,058, Processing Time 0.03 seconds

A Study on LLCL Filter to Reduce Harmonic Current of Grid Connected Power Inverter (계통연계형 인버터의 고조파 전류저감을 위한 LLCL 필터에 관한 연구)

  • An, Byoung-Woong;Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl;Lim, Byung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • In this paper, the new LLCL filter is proposed for grid connected three-phase PWM inverter for passive damping. LLCL filter inserts a small inductor in the branch of the capacitor of the traditional LCL filter to compose a series resonant circuit to reduce the switching-frequency component on grid current. Using LLCL filter, the switching-frequency current ripple components can be attenuated much better than the LCL filter, leading to a decrease in the total inductance. However, the resonance phenomena caused by zero impedance from the addition of LC branch in LLCL filter can be a big problem. Resonance phenomena of LLCL filter can be a source of grid system instability, so proper damping methods are required. However, it is difficult to apply a passive damping method in the conventional LLCL filter, because the damping resistor increase impedance of the LC branch. Therefore, switching frequency component of grid current can not much attenuated by low Q of LC series resonance effect. In this paper, a new LLCL filter is proposed to overcome the conventional LLCL filter with passive damping. The validity of the proposed method is proven by simulation and experimental result.

Layout of Long-pass-edge Filter Correspond with the Optical Transmission in Crystalline (수정체 광투과에 대응하는 LPE Filter 설계)

  • Kim, YongGeun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.57-63
    • /
    • 1999
  • The optical absorption and transmittance of cow' crystalline were measured by spectrophotometer in the 200~800nm wavelength regions. The optical absorptions of crystalline composed of a high absorption band in the UV-A, UV-B, and appeared the light transmittance edge in the 400nm wavelength region, and completely transmitted without the absorption in the high wavelength regions than 400nm. Also, the optical absorption and transmittance had no temperature dependence. The optical transmittance spectrum of crystalline concord with the thin film structure of $n_0/(0.5H)L(LH)^6(0.5H)/n_s$ and $n_0{\mid}(0.5LH0.5L)^kL/1.25{\mid}4.0$ of long-pass edge filter form. In the artificial crystalline and inter lens layout, long-pass edge filter layout can UV cut off.

  • PDF

Ambiguity Determination Technique for Multiple GPS Reference Stations using the Combination of L1/L2 Carrier Phase (L1/L2 측정치 조합을 이용한 GPS 기준국간 반송파 미지정수 결정 기법)

  • Park, Byung-Woon;Song, June-Sol;Kee, Chang-Don
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.705-713
    • /
    • 2011
  • In this paper, we introduce two techniques for resolving integer ambiguities between reference stations, which is one of the most important processes in Network RTK correction generation process. Each techniques uses Hatch filter and combination of L1/L2 measurements and we used simulation data and real data to evaluate performance of the techniques. For evaluating performance of each technique, we compared corrections generated from user site and Network RTK. As a result, Network RTK with the technique which uses Hatch filter improves user performance much more than single baseline RTK does. Residual of user is smaller than a half size of wavelength so it does not affect user integer ambiguity resolution, however, it contains significant bias error. On the other hand, when we used the technique which uses combination of L1/L2 measurements, residual error of user is largely reduced compared to the technique using Hatch filter.

The RMS Current Stress Reduction Technique in Link Capacitor of Two-stage AC/DC Converter (2단 AC/DC 컨버터의 링크 캐패시터 전류 스트레스 저감 기법)

  • Jang, Doo-Hee;Jung, Young-Jin;Roh, Chung-Wook;Hong, Sung-Soo;Han, Sang-Kyoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.449-456
    • /
    • 2009
  • The RMS(Root Mean Square) current stress reduction technique for the PFC link capacitor is proposed. Although the various parameter is exist for optimizing the link capacitor, the RMS current stress is the most weighty practical parameter. The proposed C-L filter can reduce effectively the RMS current stress by filtering the output current. And with the C-L-L-C filter proposed in this paper, the more RMS current stress can be reduce because it filters not only the output current, like C-L filter, but also the input current of DC/DC stage. The proposed filter is simple to design and have no effect on the control part of the PFC because of the very low crossover frequency. To confirm the validity of proposed filter, theoretical analysis, the design guide, verification of experimental results are presented.

Assessing the removal efficiency of Synedra sp. through analysis of field data from water treatment plants

  • Seo, Dae-Keun;Kim, Yeong-Kwan
    • Membrane and Water Treatment
    • /
    • v.11 no.2
    • /
    • pp.141-149
    • /
    • 2020
  • Prechlorination could increase the removal efficiency of Synedra, but there was no significant effect of increasing the amount of chlorine added. However, a removal efficiency of greater than 80% was noted when ozone was injected at concentrations greater than 2 mg/L. Also, it was found that on addition of polyamine, a removal efficiency of 80% or more could be achieved. As a result of the analysis of field operation data from the water treatment plants G and B, it was found that at water treatment plant G, the filter run time decreased to 10 hours or less when only coagulant was injected, but the filter run time increased to around 40 hours when polyamine (3 mg/L) was also injected. The Synedra population in the raw water subsequently increased to 2,340 cells/mL, and the filter continued running for more than 20 hours. At water treatment plant B, the average Synedra removal efficiency was 56% when only coagulant was injected, and the filter run time decreased drastically with the increasing population of Synedra in the raw water. However, the removal efficiency of Synedra reached 79% when polyamine was injected together with the coagulant, 90% when ozone was also injected, and 95% when polyamine and ozone were injected together and the filter continued running for over 50 hours. The filter run time was maintained at 60 hours when a Synedra population of 6,890 cells/mL flowed into the Paldang water source, but the filter run time with Synedra at 1,960 cells/mL decreased rapidly from 65 hours to 35 hours when the ratio of the size of the individual Synedra reaching 250 ㎛ or more, increased from 38% to 94%. Therefore, the size of the Synedra is considered to be a factor that significantly influences filter clogging, as well as the size of the Synedra population.

Design and Experiment of a Miniaturized Waveguide Band-Pass Filter Using L-Type Inverter and Small Resonant Aperture (L형 아이리스와 투과 공진 개구를 이용한 소형화된 도파관 여파기 설계 및 실험)

  • Choi, Jin-Young;Kim, Byung-Mun;Cho, Young-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.4
    • /
    • pp.457-467
    • /
    • 2012
  • In this paper, a miniaturized band-pass filter structure, which comprises the irises of small resonant aperture and L-type irises inverter, is proposed. Ridged circular aperture iris is chosen as an elementary resonator. L-type iris which is placed between two adjacent elementary resonators is newly proposed as impedance inverter in order to reduce longitudinal length of the proposed filter. The fabricated minimized filter has 400 MHz bandwidth at the 10 GHz center frequency and the whole size is reduced to 70 % in length compared to conventional filter.

The Clinical Effects of Leukocyte-Depleting Filter on Cardiopulmonary Bypass (체외순환 시 백혈구 제거필터 사용의 임상효과)

  • 박경택;최석철;최국렬;정석목;최강주
    • Journal of Chest Surgery
    • /
    • v.34 no.6
    • /
    • pp.454-464
    • /
    • 2001
  • Background: It has been recognized that systemic inflammatory reaction and oxygen free radical formed by activated leukocyte in the procedure of cardiopulmonary bypass(CPB) frequently produce postoperative cardiac and pulmonary dysfunction. The purpose of this study was to evaluate the efficacy of leukocyte-depleting filters in the cardiopulmonary bypass circuit for patients undergoing open heart surgery(OHS). Material and method: The study involved 15 patients who underwent OHS with a Leukoguard-6 leukocyte filter placed in the arterial limbs of the bypass circuit(filter group, n=15) and 15 patients who did not have the filter(control group, n=15). We analyzed the differences between the groups in intraoperative changes of peripheral blood leukocyte and platelet counts, pre- and postbypass changes of malondialdehyde(MDA), troponin-T(TnT), 5'-nucleotidase(5'-NT) in coronary sinus blood, spontaneous recovery rate of heart beat after CPB, pre-and postoperative cardiac index(Cl) and pulmonary vascular resistance(PVR), and the amounts of postoperative bleeding and sternal wound complication. Result: During CPB, total leukocyte count of the filter group(9,567$\pm$ 842/㎣) was significantly less than that of the control group(13,573+1,167/㎣) (p<0.01), but there was no significant difference in platelet count between the groups. Postoperative levels of MDA(3.78+0.32 $\mu$mol/L vs 5.86+0.65 $\mu$mo1/L, p<0.01), TnT(0.40$\pm$0.04 ng/mL vs 0.59$\pm$0.08 ng/mL, p<0.05) and 5'-NT(3.88$\pm$0.61 U/L vs 5.80$\pm$0.90 U/L, p<0.05) were all significantly lower in the filter group than the control group. Postoperative Cl was higher in the filter group than the control group(3.26$\pm$0.18 L/$m^2$min vs 2.75$\pm$0.17 L/$m^2$/min, p=0.05). PVR of the filter group was lower than that of the control group(65.87$\pm$7.59 dyne/sec/cm$^{5}$ vs 110.80+12.22 dyne/sec/cm$^{5}$ , p<0.01). Spontaneous recovery rate of heart beat in the filter group was higher than that in the control group(12 patients vs 8 patients, p<0.05). Postoperative wound infection occurred in one case in the filter group and 4 case in the control group(p<0.05). Postoperative 24 hour blood loss of the filter group was more than that of the control group (614$\pm$107 mL vs 380+71 mL, p=0.05).

  • PDF

Active Damping of LCL Filter for Three-phase PWM Inverter without Additional Hardware Sensors (추가적인 센서가 필요 없는 3상 PWM 인버터의 LCL 필터 능동댐핑)

  • An, Byoung-Woong;Shin, Hee-Keun;Kim, Hag-Wone;Cho, Kwan-Yuhl;Han, Byoung-Moon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.10-17
    • /
    • 2013
  • In this paper, a new active damping method of LCL filter without capacitor voltage sensors is proposed for 3 phase PWM Inverter. Normally, L filter or LCL filter is used as an output filter of grid connected PWM inverter. An LCL filter has more excellent performance than L filter to reduce harmonic current, so the small inductance value can be used. However, the resonance problem in LCL filter is happen due to the zero impedance by the addition of LC branch. To solve the resonance problem, the various active damping method has been proposed so far. Generally, the virtual resistor active damping methods is required to additional hardware sensors for measurement of capacitor voltage and current. In this paper, the new active damping method is proposed without any capacitor voltage or current sensors. In the proposed method, the resonance component of the capacitor voltage of LCL filter can be observed by a simple MRAS(Model Reference Adaptive System) observer without additional hardware sensors, and this component is suppressed by feedforward compensation. The validity of the proposed method is proven by simulation and experiment on the 3-phase PWM inverter system.

Development of Biological Filtration Process for Effective Nitrogen Removal in Tertiary Treatment of Sewage (생물막 여과반응기를 이용한 고도질소 제거법의 개발)

  • Jeong, Jin-Woo;Kim, Sung-Won;Tsuno, Hiroshi
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.2
    • /
    • pp.222-229
    • /
    • 2006
  • The treatment performance and operational parameters of a tertiary wastewater treatment process a biological filtration system were investigated. The biological filtration system consisted of a nitrification filter (Fiter 1) and a polishing filter with anoxic and aerobic parts (Filter 2). SS, T-C-BOD, and T-N in effluent were kept stable at less than 3, 5 mg/L, and 5 mgN/L, respectively, under a HRT in Filter (filter-bed) of 0.37~2.3 h. T-N at the outlet of Filter 2 were about 1~5 mgN/L under the condition of LV of 50~202 m/d. In Filter 2, denitrification was accomplished under LV of 50~168 m/d in a 1 m filter-bed. However, the denitrification capacity reached the maximum when the linear velocity was increased to 202 m/d. Relationship between increase in microorganism and headloss was clearer in Filter 2. As a result, the denitrification rate increased from 1.0~2.3 kgN/($m^3-filter-bed{\cdot}d$) as the headloss increased. The COD removal rate was 6.0~9.6 kgCOD/($m^3-filter-bed{\cdot}d$) when operated with Filters 1 and 2. These results mean that captured bacteria contributed a part of COD consumption and denitrification. The maximum nitrification and denitrification rate was 0.5 and 4 kgN/($m^3-filter-bed{\cdot}d$) in Filter 1 and 2.The ratio of backwashing water to the treated water was about 5~10 %. In Filter 1, wasted sludge in backwashing was only 0.7~5.3 gSS/($m^3$-treated water). In Filter 2, added methanol was converted into sludge and its value was 8.0~24 gSS/($m^3$-treated water). These results proved that this process is both convenient to install as tertiary treatment and cost effective to build and operate.

A New Sign Subband Adaptive Filter with Improved Convergence Rate (향상된 수렴속도를 가지는 부호 부밴드 적응 필터)

  • Lee, Eun Jong;Chung, Ik Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.335-340
    • /
    • 2014
  • In this paper, we propose a new sign subband adaptive filter to improve the convergence rate of the conventional sign subband adaptive filter which has been proposed to deal with colored input signal under the environment with impulsive noise. The existing sign subband adaptive filter does not increase the convergence speed by increasing the number of subband because each subband input signal is normalized by $l_2-norm$ of all of the subband input signals. We devised a new sign subband adaptive filter that normalizes each subband input signal with $l_2-norm$ of each subband input signal and increases the convergence rate by increasing the number of subband. We carried out a performance comparison of the proposed algorithm with the existing sign subband adaptive filter using a system identification model. It is shown that the proposed algorithm has faster convergence rate than the existing sign subband adaptive filter.