• Title/Summary/Keyword: L-curve

Search Result 1,388, Processing Time 0.029 seconds

A Study on the Fracture Resistance Curve and Effect of Side Grooves of SG365 Material (SG365강의 파괴저항곡선과 측면홈효과에 관한 연구)

  • 임만배
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.14-21
    • /
    • 2001
  • SG-365 steel is an important material End used for manufacturing a pressure vessel and gas piping. In this investigation, the elastic plastic fracture toughness of this material is evaluated by the unloading compliance method according to the ASTM E8l3-97 and E1152-97 method on the smooth and side groove In specimens. The effect of smooth and side groove is studied on the elastic plastic fracture toughness. The side grooved specimen is very useful in estimation of the $J_{IC}$. Because it is much easier than the smooth specimen to the onset of the ductile tearing by the R curve method. Besides. it improves the accuracy of toughness values, decreases the scattering of them and crack tunneling effect and shear lip by the side groove.

  • PDF

An approach of using ideal gradating curve and coating paste thickness to design concrete performance-(2) Experimental work

  • Wang, H.Y.;Hwang, C.L.;Yeh, S.T.
    • Computers and Concrete
    • /
    • v.10 no.1
    • /
    • pp.35-47
    • /
    • 2012
  • The ideal gradating curve is used in this study to estimate densified aggregate blended ratio and total surface area of aggregate, there by under assigned paste amount of concrete, and coating paste thickness can then be deduced. Four groups of concrete mixtures were prepared and the corresponding concrete properties, such as workability, compression strength, ultrasonic velocity, surface resistivity and chloride ion penetration, were measured and finally the results are interpreted in terms of "coating thickness". The result shows as the coating thickness of the concrete is higher than critical one, the coating thickness on aggregate does affect the workability, and whatever workability is required the superplasticizer can be adjusted to achieve the demand workability. Under a fixed paste quality at the same age, coating paste thickness is inversely proportional to the concrete properties, especially as the coating thickness gets thinner.

An approach of using ideal grading curve and coating paste thickness to evaluate the performances of concrete-(1) Theory and formulation

  • Wang, H.Y.;Hwang, C.L.;Yeh, S.T.
    • Computers and Concrete
    • /
    • v.10 no.1
    • /
    • pp.19-33
    • /
    • 2012
  • The performance of a concrete is significantly influenced by its mixture proportion and the coating thickness on aggregate surface. The concrete in this study is designed by estimating the blending ratio of aggregate using a densified mixture design algorithm (DMDA) based on an ideal grading curve and estimating the paste volume as the sum of the amount of paste needed to provide an assigned coating paste thickness. So as to obtain appropriate concrete amount, and thus can accurately estimate the property of concrete. Deduction of this mix design formula is simple and easy understanding, and meanwhile to obtain result is fast. This estimation model of mix design is expected to reward to industry and effectively upgrade concrete quality.

The Mesh Selectivity of Trawl Cod-end for the Compressed From Fishes (측편형어류에 대한 트롤 끝자루의 망목선택성)

  • Jeong, Sun-Beom;Lee, Ju-Hee;Kim, Sam-Gon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.4
    • /
    • pp.247-259
    • /
    • 1993
  • The fishing experiment was carried out by the training ship Saebada in order to analyse the mesh selectivity for trawl cod-end, in the Southern Korea Sea and the East China Sea from June. 1991 through August, 1992. The trawl cod-end used in this experiment has the trouser type of cod-end with cover net. and the mesh selectivity was examined for the five kinds of the opening of mesh in its cod-end part. A total of 163 hauls, of which having mesh size 51.2mm ; A 89, 70.2mm ; B 54, 77.6mm ; C 55, 88.0mm ; D 52 and 111.3mm ; E 20 were used respectively. Selection curves and selection parameters were calculated by using a logistic function, S=1/(1+exp super(-(aL+b)) ). The mesh election master curves were estimated by S=1/(1+exp super(-[a(L/M)+$\beta$]) ). and the optimum mesh size were calculated with (L/M) sub(50) of master curve. In these cases 'a' and '$\alpha$' are slope, 'b' and '$\beta$' are intercept. 'L' is body length of the target species of fishes, 'M' is the mesh size, and 'S' denotes mesh selectivity. In this report, the four species of compressed form fishes were taken analized according to fish shape, and 'S' denotes mesh selectivity. In this report, the four species of compressed form fishes were taken analized according to fish shape, and the results obtained are summarized as follows: 1. Red seabream Pagrus major(Temminct et Schlegel) and yellow porgy Dentex tumifrons(Temminct et Schlegel) ; Selection rate in each mesh size of A, B, C, D and E were 99.7%, 97.5%, 91.4%, 76.7% and 57.8% respectively. Selection parameters 'a' and 'b' of mesh sizes C, D and E were 2.65 and -28.62, 4.40 and -77.73, 2.31 and -46.99, and their selection factors were 1.39, 2.10, 1.83 respectively. Selection parameters of master curve '$\alpha$' and '$\beta$' were 3.05 and -5.65 respectively, and (L/M) sub(50) was 1.85. The optimum mesh size of Red seabream was 141mm. 2. Filefish Thamnaconus modestus (Gunther) ; Selection rate in each mesh size of A, B, C, D and E were 99.6%, 98.3%, 91.2%, 80.0% and 48.6% respectively. Selection parameters 'a' and 'b' of mesh sizes C, D and E were 5.82 and -55.10, 2.92 and -36.90, 3.91 and -63.09, and their selection factors were 1.35, 1.44, 1.45 respectively. Selection parameters of master curve '$\alpha$' and '$\beta$' were 3.02 and -4.32 respectively, and (L/M) sub(50) was 1.43. The optimum mesh size was 129mm. 3. Target dory Zeus faber Valenciennes ; Selection rate in each mesh size of A, B, C, D and E were 99.7%, 100%, 83.2%, 91.6% and 65.0% respectively. Selection parameters 'a' and 'b' of mesh sizes C, D and E were 3.85 and -32.46, 4.19 and -57.38, 2.45 and -40.03, and their selection factors were 1.09, 1.56, 1.47 respectively. Selection parameters of master curve '$\alpha$' and '$\beta$' were 2.64 and -3.53 respectively, and (L/M) sub(50) was 1.34. The optimum mesh size was 127mm. 4. Butterfish Psenopsis anomala (Temminct et Schlegel) ; Selection rate in each mesh size of A, B, C, D and E were 99.2%, 34.1%, 46.5%, 14.3% and 2.4% respectively. Selection parameters 'a' and 'b' of mesh sizes B, C and D were 5.35 and -71.70, 5.07 and -69.25, 3.31 and -62.06 and their selection factors were 1.91, 1.75, 2.13 respectively. Selection parameters of master curve '$\alpha$' and '$\beta$' were 3.16 and -6.24 respectively, and (L/M) sub(50) was 1.98. The optimum mesh size was 71mm.

  • PDF

Bioconjugation by dual heterobifunctional coupling method: Use of the conjugates for the detection of dopamine (서로 다른 두 작용기를 이용한 결합법에 의한 접합체: 도파민 면역분석법)

  • Ryu, Ji-Eun;Rhee Paeng, In-Sook
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.537-543
    • /
    • 2010
  • Dopamine (DA) is an important neurotransmitter molecule of catecholamines. Its deficiency could lead to brain disorder such as Parkinson's disease and schizophrenia. Therefore, it is necessary to establish a suitable analytical technique with sensitivity and simplicity. A competitive enzyme-linked immunosorbent assay for DA has been optimized and characterized. Assay sensitivity is controlled by two factors in competitive immunoassay. One is a nature and concentration of competitor, and the other is those of binder, antibody. Thus, optimization was performed: BSA-DA conjugate and antibody-avidin conjugate were prepared by dual heterobifunctional coupling method using SATA and SMCC. Assay condition was optimized with $6.66\;{\mu}gmL^{-1}$ of BSA-DA and $4.17{\times}10^{-10}\;M$ of antibody-avidin conjugate. A dose-response curve was constructed, and a limit of detection and a dynamic range for DA were accomplished to $2.3{\times}10^{-2}\;{\mu}g\;mL^{-1}$ and four orders of magnitude ($1.0{\times}10^{-7}\;M$ to $1.0{\times}10^{-3}\;M$), respectively. Calibration curve was constructed on dynamic range and least-squares regression of this data gave the following relationship: absorbance = -0.1098 log[DA]+0.0353 ($R^2$ = 0.9956).

Electro-optical Characteristics in the Vortical-Alignment 1/4$\pi$ Cell by photoalignment Method (광배향법을 이용한 VA-l/4$\pi$셀의 전기 광학 특성)

  • 이윤건;황정연;서대식;김재형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.369-372
    • /
    • 2001
  • We studied the electro-optical (EO) performance in the vertical-alignment (VA) - l/4$\pi$ cell photoaligned with polarized UV exposure on a homeotropic photopolymer surfaces. Excellent voltage-transmittance curve in the VA - l/4$\pi$ cell photoaligned with polarized UV exposure for 3 min on the photopolymer containing cholesterol group of 8% can be achieved. The V-T characteristics in the VA-l/4$\pi$ cell photoaligned on the photopolymer surface can be improved by increasing cholesteryl group. For response time measurement, the transmittance characteristics of the VA-l/4$\pi$ cell photoaligned on the photopolymer surface was better than that of the VA-l/4$\pi$ cell rubbingaligned on a polyimide(Pl) surface.

  • PDF

Thermoluminescence (TL) of Minerals Separated from Irradiated Mussel

  • Yi, Sang-Duk;Oh, Man-Jin
    • Preventive Nutrition and Food Science
    • /
    • v.10 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • This study was carried out to determine whether detection of minerals separated from irradiated mussel could be could be done by thermoluminescence (TL) method. After the minerals were separated by sodium polytungstate solution (2.0 g/mL) from irradiated mussel, organic compounds remaining in the minerals were removed by acid-base treatment and dried at 50℃ overnight, and then the minerals were measured through TL. The TL intensities of separated minerals at different irradiation doses during storage conditions of room and darkroom were obtained. TL intensity of first glow curves for minerals separated from irradiated mussel showed linear increase from the control to 5 kGy and slight increase from 5 kGy to 10 kGy. Since glow curve ratios of G2, G3 and G4, calculated from re-irradiated minerals measured immediately after irradiation and after storage of three months were over 0.5, detection of irradiation was possible. G1, which showed the glow curve ratios above 0.1, was classified as non-irradiated samples because the unique first glow curve was not found within the recommended temperature interval (150-230℃). Hence, on the basis of TL intensity, and glow curve ratio and shape, it is possible to correctly identify irradaited mussels after mineral separation during storage.

ON THE HOMOGENEITY OF THE EXTINCTION LAW IN OUR GALAXY

  • Bondar, A.;Galazutdinov, G.;Patriarchi, P.;Krelowski, J.
    • Journal of The Korean Astronomical Society
    • /
    • v.39 no.3
    • /
    • pp.73-80
    • /
    • 2006
  • We analyze the extinction law towards several B1V stars-members of our Galaxy, searching for possible discrepancies from the galactic average extinction curve. Our photometric data allow to build extinction curves in a very broad range: from extreme UV till infrared. Two-colour diagrams, based on the collected photometric data from the ANS UV satellite, published UBV measurements and on the infrared 2MASS data of the selected stars, are constructed. Slopes of the fitted straight lines are used to build the average extinction curve and to search for discrepant objects. The selected stars have also been observed spectroscopically from the Terskol and ESO Observatories; these spectra allow to check their Sp/L's. The spectra of only about 30% of the initially selected objects resemble closely that of HD144470, considered as the standard of B1 V type. Other spectra either show some emission features or belong clearly to another spectral types. They are not used to build the extinction curve. Two-colour diagrams, constructed for the selected B1 V stars, showing no emission stellar features, prove that the interstellar extinction law is homogeneous in the Galaxy. Both the shape of the curve and the total-to-selective extinction ratio do not differ from the galactic average and the canonical value(3.1) respectively. The circumstellar emissions usually cause some discrepancies from the average interstellar extinction law; the discrepancies observed in the extraterrestrial ultraviolet, usually follow some misclassifications.

Mathematical Analysis of Growth of Tobacco (Nicotiana tabaccum L.) II. A New Model for Growth Curve (담배의 생장반응에 관한 수리해석적 연구 제2보 담배생장곡선의 신모형에 관하여)

  • Kim, Y.A.;Ban, Y.S.
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.27 no.1
    • /
    • pp.84-86
    • /
    • 1982
  • The experiment was conducted with three varieties (Hicks, Burley 21, and Sohyang) and cultivation type (Improved mulching, general mulching, and non mulching) of NC 2326 to model to curve of tabacco growth against time. The basic growth data were obtained by harvest method at intervals of ten days from transplanting at 7-8 times and analyzed by polynomial regression, orthogonal polynomial, and logarithmic transformation. It is shown that the C model of growth curve: T = A +$\sqrt{(1.4 AK + K)}$2K provides an excellent fit.

  • PDF

Determination of Rh(III) by Spectrofluorimetry Using Oxidation Reaction of Nile Blue (Nile Blue의 산화반응을 이용한 Rh(III)의 형광분광법적 정량)

  • Lee, Sang Hak;Lee, Myeong
    • Journal of the Korean Chemical Society
    • /
    • v.45 no.1
    • /
    • pp.25-30
    • /
    • 2001
  • A selective kinetic fluorimetric method for the determination of trace rhodium(Ⅲ), based on the catalytic effect of rhodium(Ⅲ) on the oxidation of nile blue by periodate have been studied. The effects of pH and concentrations of nile blue, sodium periodate, trioctyl phosphine oxide(TOPO) and temperature were investigated. The calibration curve for rhodium(Ⅲ) ion was linear over the range from 100 ng/mL to 0.1 ng/mL and the detection limit was 0.01 ng/mL under the optimal experimental conditions. Effects of interferences from several cations and anions for the determination of rhodium(Ⅲ) were also investigated.

  • PDF