• Title/Summary/Keyword: L-box flow test

Search Result 27, Processing Time 0.019 seconds

Flow Properties of Polypropylene Fiber Reinforced High flow Concrete (폴리프로필렌 섬유보강 고유동 콘크리트의 유동 특성)

  • Noh, Kyung-Hee;Sung, Chan-Yong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.4
    • /
    • pp.57-63
    • /
    • 2004
  • This study was performed to evaluate flow properties of polypropylene fiber reinforced high flow concrete. Test results were showed that the slump, slump flow and L-type compacting were decreased with increasing the content of polypropylene fiber. But, the Box-type passing and air content were increased with increasing the content of polypropylene fiber. The slump was $25.5{\sim}27.5cm$, the slump flow was $60{\sim}65cm$, the Box-type passing was $2{\sim}6cm$, the L-type compacting was excellent and air content was $2.7{\sim}3.2cm%$ by the polypropylene fiber content 0.2%, respectively. This concrete can be used for high flow concrete.

Engineering Property of Polyprofilene Fiber Reinforced High Flowable Concrete (폴리프로필렌섬유 보람 고유동 콘크리트의 공학적 특성)

  • Noh, Kyung-Hee;Kim, Young-Ik;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.185-188
    • /
    • 2002
  • This study is performed to examine the engineering properties of polyprofilene fiber reinforced high flowable concrete. For the estimation of the flow ability and filling ability, the slump flow, box height difference and L-shape filling appearence are measured and compared. The test result shows that the slump flow and L-shape filling appearence is decreased with increase containing polyprofilene fiber and box height difference is increased with increase containing polyprofilene fiber. Also, compressive strength is decreased with increase containing polyprofilene fiber.

  • PDF

Model for Flow Analysis of Fresh Concrete Using Particle Method with Visco-Plastic Flow Formulation (점소성 유동 입자법에 의한 굳지 않은 콘크리트의 유동해석 모델)

  • Cho, Chang-Geun;Kim, Wha-Jung;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.3
    • /
    • pp.317-323
    • /
    • 2008
  • In the current study, A model for the flow analysis of fresh and highly flowable concrete has been developed using a particle method, the moving particle semi-implicit (MPS) method. The phenomena on the flow of concrete has been considered as a visco-plastic flow problem, and the basic governing equation of concrete particle dynamics has been based on the Navier-Stokes equation in Lagrangian form and the conservation of mass. In order to formulate a visco-plastic flow constitutive law of fresh concrete, concrete is modeled as a highly viscous material in the state of non-flow and as a visco-plastic material in the state of flow after reaching the yield stress of fresh concrete. A flow test of fresh concrete in the L-box was simulated and the predicted flow was well matched with the experimental result. The developed method was well showed the flow motion of concrete particles because it was formulated to be based on the motion of visco-plastic fluid dynamics.

An Experimental Study on the Fluidity of High Flowing Concrete Affected by Fine Aggregate Types (고유동콘크리트의 각종 유동특성에 미치는 세골재의 영향에 관한 실험적 연구)

  • 김규용;신홍철;최세진;강희관;조성현;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.04a
    • /
    • pp.220-226
    • /
    • 1997
  • High flowing concrete has flowability, passability, segregation resistance and so on, and there are so many influence factor to affect to fluidity of high flowing concrete, therefore it is so difficult to evaluate exactly the properties in fresh state. This study is to analyze and evaluate thefluidity of high flowing concrete affected by fine aggregate with test method such as, slump-flow test, V-lot test, L-flow test, Box filling test.

  • PDF

Rheology Property of Steel Fiber Reinforced High Performance Concrete (강섬유 보강 고성능 콘크리트의 유동 특성)

  • Kim, Young-Ik;Sung, Chan-Yong
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.205-208
    • /
    • 2002
  • This study is performed to examine the flowability and filling ability of steel fiber reinforced high performance concrete. For the estimation of the flowability and filling ability, slump flow, box height difference and L-shape filling appearence are measured and compared. The test result shows that the slump flow is $60{\pm}5cm$ to make no difference with containing steel fiber, box height difference is increased with increasing steel fiber and L-shape filling appearence is to bad with increasing steel fiber. But, proper containg of steel fiber is considered to be applied for high performance concrete without decreasing of slump flow and filling ability.

  • PDF

Flow Simulation of High Flow Concrete using Incompressible Smoothed Particle Hydrodynamics (ISPH) Method (ISPH 기법을 이용한 고유동 콘크리트의 유동 해석)

  • Kim, Sang-Sin;Chung, Chul-Woo;Lee, Chang-Joon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.1
    • /
    • pp.39-46
    • /
    • 2019
  • A three-dimensional flow simulation model for high flow concrete was developed using Incompressible Smoothed Particle Hydrodynamics (ISPH), which can solved Navier-Stokes equation with the assumption of a fluid to be incompressible. For the simulation, a computer program code for ISPH was implemented with MATALB programming code. A piecewise cubic spline function was used for the kernel function of ISPH. Projetion method was used to calculate the velocity and pressure of particles as a function of time. Fixed ghost particle was used for wall boundary condition. Free surface boundaries were determined by using virtual density of particles. In order to validate the model and the code, the simulation results of slump flow test, $T_{500}$ test and L-box test were compared with experimental ones. The simulation results were well matched with the experimental results. The simulation described successfully the characteristics of the flow phenomenon according to the change of the viscosity and yield stress of high flow concrete.

Optimization of Swirl Ratio of Intake Port in 11L LPLi Engine (11L급 LPLi방식 대형엔진의 흡기스월비 최적화 연구)

  • 이진욱;강건용;민경덕
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.3
    • /
    • pp.99-105
    • /
    • 2003
  • The configuration of intake port is a dominant factor of inlet air flow and mixture formation in an engine. In this study, as an available technology to optimum intake port, the flow box system using resine has been applied. So we presents a methodology for estimating inlet flow characteristics in this paper. This quantified experimental result shows good agreements with visualization data in a cylinder. We obtained the optimal value of swirl ratio and flow coefficient under steady flow rig test for new development of intake port for heavy-duty engine. From this results, the cylinder heat with a good evaluated swirl flow characteristics was developed and adapted for a 11L heavy-duty engine using the liquid phase LPG injection (LPLi) system. This .research expects to clarify major factor that make the intake port efficiently.

A Evaluation on the Field Application of High Strength Concrete for CFT Column (고강도 CFT용 콘크리트의 현장적용성 평가 및 장기거동 예측)

  • Park, Je Young;Chung, Kyung Soo;Kim, Woo Jae;Lee, Jong In;Kim, Yong Min
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.707-714
    • /
    • 2014
  • CFT (Concrete-Filled Tube) is a type of steel column comprised of steel tube and concrete. Steel tube holds concrete and the concrete inside tube takes charge of compressive load. This study presents structural performance of the CFT column which has 73~100 MPa high strength concrete inside. Fluidity, mechanical compression, pump pressure test in flexible pipe were conducted for understanding properties of the high strength concrete. Material properties were achieved by various experimental tests, such as slump, slump flow, air content, U-box, O-Lot, L-flow. In addition, mock-up tests were conducted to monitor concrete filling, hydration heat, compressive strength. From construction sites in Sang-am dong and University of Seo-kang, long-term behaviors could be effectively predicted in terms of ACI 209 material model considering elastic deformation, shrinkage and creep.

Flow Experiments and Analysis of Highly Flowable Concrete Considering the Effect of Dosages of SP Admixture and W/C Ratios (SP제 및 물시멘트비 영향을 고려한 초유동 콘크리트의 흐름 실험 및 해석)

  • Cho, Chang-Geun;Kim, Wha-Jung;Choi, Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.6
    • /
    • pp.671-677
    • /
    • 2014
  • In this research, flow experiments and simulation of highly flowable concrete has been attempted using a viscoplastic particle method varying with dosages of SP admixture and water-cement (W/C) ratios. Rheological and flow characteristics of flowable concrete manufactured in domestic products of cement, aggregates, and SP admixtures were investigated by experimental programs varying with mix proportions. From experiment, the predictive model of rheological characteristics of flowable concrete has been newly proposed considering with the effects of the W/C ratio and the dosage of SP admixture, and the effect of mixing proportion has also been incorporated into shear stress and strain rate curve of flowable concrete in the current method. A series of L-box flow test of highly flowable concrete varying with dosages of SP admixture and W/C ratios was compared with the proposed model.

An Experimental Study on the Property of High Performance Concrete for Concrete Filled Tube with Addition Content of Steel Fiber (강섬유 첨가량에 따른 콘크리트 충전강관용 고성능 콘크리트 특성에 관한 실험적 연구)

  • Seo, Il;Hong, Seok-Beom;Yoo, Jo-Hyeong;Park, Hee-Gon;Kim, Woo-Jae;Lee, Jae-Sam
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.213-214
    • /
    • 2012
  • This paper presents basic study to develop high performance concrete for concrete filled tube with addition content of steel fiber. In this study, all mixtures was added to nylon fiber (1.5 kg/㎥) and steel fiber was mixed by 0, 20 and 40 kg/㎥ respectively. To evaluate the property of high performance concrete was used to various test methods which were slump flow, air content, U-box test, O-lot test and L-flow(to 300 mm, 500 mm). Also, compressive strength test was measured by ages.

  • PDF