• Title/Summary/Keyword: L-Tube

Search Result 794, Processing Time 0.03 seconds

Operative Treatment of Congenitally Corrected Transposition of the Great Arteries(CCTGA) (교정형 대혈관 전위증의 수술적 치료)

  • 이정렬;조광리;김용진;노준량;서결필
    • Journal of Chest Surgery
    • /
    • v.32 no.7
    • /
    • pp.621-627
    • /
    • 1999
  • Background: Sixty five cases with congenitally corrected transposition of the great arteries (CCTGA) indicated for biventricular repair were operated on between 1984 and september 1998. Comparison between the results of the conventional(classic) connection(LV-PA) and the anatomic repair was done. Material and Method: Retrospective review was carried out based on the medical records of the patients. Operative procedures, complications and the long-term results accoding to the combining anomalies were analysed. Result: Mean age was 5.5$\pm$4.8 years(range, 2 months to 18years). Thirty nine were male and 26 were female. Situs solitus {S,L,L} was in 53 and situs inversus{I,D,D} in 12. There was no left ventricular outflow tract obstruction(LVOTO) in 13(20%) cases. The LVOTO was resulted from pulmonary stenosis(PS) in 26(40%)patients and from pulmonary atresia(PA) in 26(40%) patients. Twenty-five(38.5%) patients had tricuspid valve regurgitation(TR) greater than the mild degree that was present preoperatively. Twenty two patients previously underwent 24 systemic- pulmonary shunts previously. In the 13 patients without LVOTO, 7 simple closure of VSD or ASD, 3 tricuspid valve replacements(TVR), and 3 anatomic corrections(3 double switch operations: 1 Senning+ Rastelli, 1 Senning+REV-type, and 1 Senning+Arterial switch opera tion) were performed. As to the 26 patients with CCTGA+VSD or ASD+LVOTO(PS), 24 classic repairs and 2 double switch operations(1 Senning+Rastelli, 1 Mustard+REV-type) were done. In the 26 cases with CCTGA+VSD+LVOTO(PA), 19 classic repairs(18 Rastelli, 1 REV-type), and 7 double switch operations(7 Senning+Rastelli) were done. The degree of tricuspid regurgitation increased during the follow-up periods from 1.3$\pm$1.4 to 2.2$\pm$1.0 in the classic repair group(p<0.05), but not in the double switch group. Two patients had complete AV block preoperatively, and additional 7(10.8%) had newly developed complete AV block after the operation. Other complications were recurrent LVOTO(10), thromboembolism(4), persistent chest tube drainage over 2 weeks(4), chylothorax(3), bleeding(3), acute renal failure(2), and mediastinitis(2). Mean follow-up was 54$\pm$49 months(0-177 months). Thirteen patients died after the operation(operative mortality rate: 20.0%(13/65)), and there were 3 additional deaths during the follow up period(overall mortality: 24.6%(16/65)). The operative mortality in patients underwent anatomic repair was 33.3%(4/12). The actuarial survival rates at 1, 5, and 10 years were 75.0$\pm$5.6%, 75.0$\pm$5.6%, and 69.2$\pm$7.6%. Common causes of death were low cardiac output syndrome(8) and heart failure from TR(5). Conclusion: Although our study could not demonstrate the superiority of each classic or anatomic repair, we found that the anatomic repair has a merit of preventing the deterioration of tricuspid valve regurgitations. Meticulous selection of the patients and longer follow-up terms are mandatory to establish the selective advantages of both strategies.

  • PDF

Evaluation of SharpIR Reconstruction Method in PET/CT (PET/CT 검사에서 SharpIR 재구성 방법의 평가)

  • Kim, Jung-Yul;Kang, Chun-Koo;Park, Hoon-Hee;Lim, Han-Sang;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.12-16
    • /
    • 2012
  • Purpose : In conventional PET image reconstruction, iterative reconstruction methods such as OSEM (Ordered Subsets Expectation Maximization) have now generally replaced traditional analytic methods such as filtered back-projection. This includes improvements in components of the system model geometry, fully 3D scatter and low noise randoms estimates. SharpIR algorithm is to improve PET image contrast to noise by incorporating information about the PET detector response into the 3D iterative reconstruction algorithm. The aim of this study is evaluation of SharpIR reconstruction method in PET/CT. Materials and Methods: For the measurement of detector response for the spatial resolution, a capillary tube was filled with FDG and scanned at varying distances from the iso-center (5, 10, 15, 20 cm). To measure image quality for contrast recovery, the NEMA IEC body phantom (Data Spectrum Corporation, Hillsborough, NC) with diameters of 1, 13, 17 and 22 for simulating hot and 28 and 37 mm for simulating cold lesions. A solution of 5.4 kBq/mL of $^{18}F$-FDG in water was used as a radioactive background obtaining a lesion of background ratio of 4.0. Images were reconstructed with VUE point HD and VUE point HD using SharpIR reconstruction algorithm. For the clinical evaluation, a whole body FDG scan acquired and to demonstrate contrast recovery, ROIs were drawn on a metabolic hot spot and also on a uniform region of the liver. Images were reconstructed with function of varying iteration number (1~10). Results: The result of increases axial distance from iso-center, full width at half maximum (FWHM) is also increasing in VUE point HD reconstruction image. Even showed an increasing distances constant FWHM. VUE point HD with SharpIR than VUE point HD showed improves contrast recovery in phantom and clinical study. Conclusion: By incorporating more information about the detector system response, the SharpIR algorithm improves the accuracy of underlying model used in VUE point HD. SharpIR algorithm improve spatial resolution for a line source in air, and improves contrast recovery at equivalent noise levels in phantoms and clinical studies. Therefore, SharpIR algorithm can be applied as through a longitudinal study will be useful in clinical.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Quality and Storage Characteristics of Low Salted Onion and Five Cereals-Doenjang (저염 양파 오곡된장의 품질 및 저장 특성)

  • Shin, A-Ga;Lee, Ye-Kyung;Jung, Yoo-Kyung;Kim, Soon-Dong
    • Food Science and Preservation
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 2008
  • The quality and storage characteristics of low salted onion and five cereals-doenjang (DFO) were investigated. At the DFO, soybean koji ($57{\sim}62%$), onion (3%) and salt (8%) were mixed with equal amount of rice, barley, glutinous millet and glutinous indian millet ($10{\sim}30%$), and water ($7{\sim}12%$). The storage of DFO was done by vacuum packing in polypropylene tube, and sterilized at $121^{\circ}C$. The fermentation and storage was conducted for 60 days at $25^{\circ}C$ at each condition. Control doenjang (GD) was the salinity of 16% soybean doenjang that was not sterilized and packed in plastic containers for storage. During the fermentation, pH of DFO was lower than GD. The pH maintained stability during the storage, and revealed to be lowered, as the proportion of mixed cereals was higher. During the fermentation of DFO, the brix degree revealed to be higher than GD and maintained s1ability during the storage. During the fermentation and storage, the amino nitrogen content of DFO was ranged $400{\sim}470mg%$ by showing higher content than GD and maintained stable content during the storage. During the fermentation, the activities of protease and ${\beta}$-amylase were maintained to be high at DFO, but the activities during the storage were high at GD. The color $L^*$ value of DFO during fermentation and storage maintained higher values than GD, but $a^*$ value revealed lower pattern. Total free amino acids of DFO was ranged $1,918{\sim}2,290mg%$ which was higher than GD that recorded 1,291 mg%. When the sensory evaluation was conducted for DFO that was fermented and stored for 60 days, the DFO mixed with $20{\sim}30%$ of cereals resulted to have more savory taste, flavor, and sweeter than GD, and overall acceptability for color and overall taste was high.

Gastric Dilatation and Volvulus in Shih-tzu (시츄에서 발견된 위확대염전)

  • Moon, Joon Ho;Kim, Hyun Ah;Ryu, Minok;Jang, Min;Ji, Seoyeon;Lee, Inhyung;Yoon, Junghee;Choi, Mincheol;Youn, Hwayoung;Lee, Byeong Chun;Jang, Goo
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.255-258
    • /
    • 2015
  • Gastric dilatation and volvulus (GDV) is an acute and life-threatening disease most commonly affecting large- and giant-breed dogs. However a 17-year-old Shih-tzu (4 kg, spayed female) was hospitalized for acute GDV. Repeated unproductive retching, lethargy, and excessively enlarged abdomen were observed. Physical examination indicated that the patient had suffered from hypothermia ($36.5^{\circ}C$), tachycardia (240 bpm), slowed capillary refill time (> 2 sec.), and pale mucous membrane. Grade III murmur with normal lung sound was auscultated. Abdominal palpation revealed that tympanic regions existed in both the left and right sides. Systolic blood pressure decreased gradually from 220 to 40 mmHg within 4 hours. In blood analysis, slight azotemia was observed by blood urea nitrogen (BUN; 29.1 mg/dl) and creatinine (1.6 mg/dl). Blood lactate concentration (8.13 mmol/l) was severely elevated. Additionally, dilatation and volvulus of the stomach was observed by radiograph. Supportive oxygen, heat, fluid, and drugs were administered with gastric decompressions (e.g., gastrocentesis and nasogastric tube). However the patient entered into comatose status with uncontrollable systolic blood pressure, despite the administration of dobutamine intravenously. The case was closed by euthanasia, considering welfare and age. We finally diagnosed the patient as a GDV, thus this is the first GDV case report in small-breed dog such as Shih-tzu.

ANTIMICROBIAL EFFECT OF ANTIBIOTICS AND ROOT CANAL CEMENTS ON THE PREDOMINANT PATHOGENIC ANAEROBIC MICROFLORA IN ROOT CANALS (근관내 주요 혐기성 병인균에 대한 수종 항생제와 근관충전용 세멘트의 항균효과에 관한 연구)

  • Bae, Kwang-Shik
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.2
    • /
    • pp.515-525
    • /
    • 1993
  • The purpose of this study was to evaluate the susceptibility of anaerobic microorganisms to certain antibiotics and root canal cements. Prevotella intermedia(Bacteroides intermedius) ATCC 25611(serotype A), Fusobacterium nucleatum ATCC 25586, Actinomyces viscosus ATCC 15987 which are the predominant pathogenic anaerobes in dental root canals were cultured in BHI for 48 hours(Fig.1). After each $200{\mu}l$ of those broths with microorganisms was streaked on each surface of blood agar plate, 2 to 5 antibiotic discs which are impregnated with Tetrncycline, Erythromycin, Ampicillin, Clindamycin, or Vancomycin were applied on each surface of blood agar plate and cultured for 5 days anaerobically in the anaerobic chamber (Fig.2). 15 antibiotic discs for each kind of antibiotics and each species of microorganisms were tested. Also each kind of root canal cement tubes which include Zinc oxide eugenol cement, Zinc phosphate cement, Calcium hydroxide powder+DD.W., Calcium hydroxide paste(Pulpdent Tempcanal), or Vitapex(Table 1) were applied on the inoculated BAPs after $200{\mu}l$ of each experimental species of microorganisms was streaked on the surface of blood agar plates, and they were cultured for 5 days anaerobically in the anaerobic chamber(Fig.3). The sensitivity(antimicrobial effect) was determined by the diameter of the inhibition zone. The results are as follows: 1. The results of antibiotic susceptibility test(Table 2) 1) All of the tested antibiotics had antimicrobial activity with various degrees. 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Erythromycin($37.87mm{\pm}2.20$) was largest, those to Tetracycline($26.20mm{\pm}2.96$), Vancomycin($21.53mm{\pm}1.96$), Clindamycin($18.73mm{\pm}0.96$) was smaller than former orderly, and That to Ampicillin ($7.87mm{\pm}0.83$) was smallest. 3) In Actinomyces viscosus, the diameter of inhibition zone to Erythromycin($28.73mm{\pm}1.22$) was largest, those to Ampicillin($21.73mm{\pm}1.03$), Clindamycin($21.33mm{\pm}1.59$) was similarly next order, that to Vancomycin($19.00mm{\pm}1.96$) was smaller than Clindamycin, and that to Tetracycline($11.93mm{\pm}0.70$) was smallest. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Ampicillin($31.07mm{\pm}1.91$) was largest, that to Erythromycin($28.87mm{\pm}0.92$), Clindamycin($20.47mm{\pm}1.51$), Vancomycin ($16.73mm{\pm}0.96$), Tetracycline ($12.13mm{\pm}1.06$) are smaller than former orderly. 2. The results of root canal cements and pastes(Table 3) 1) The external diameter of tube is 4mm, so 4mm of the inhibition zone diameter means non-susceptable. Prevotella intermedia (old Bacteroides intermedius) was non-susceptable to Calcium hydroxide powder+D.D.W., Calcium hydroxide paste(pulpdent Tempcanal), and Actinomyces viscosus was non-susceptable to Zinc phosphate cement, Calcium hydroxide powder + D.D.W., Calcium hydroxide paste(pulpdent Tempcanal). 2) In Prevotella intermedia (old Bacteroides intermedius), the diameter of inhibition zone to Zinc oxide eugenol cement($13.67mm{\pm}3.30$) was largest, that to Vitapex($9.20mm{\pm}2.96$), Zinc phosphate cement($6.13mm{\pm}2.07$) was smaller than former. 3) In Actinomyces viscosus, the diameter of inhibition zone to Zinc oxide eugenol cement($17.40mm{\pm}5.20$) was largest and that to Vitapex($8.80mm{\pm}1.70$) was next order. 4) In Fusobacterium nucleatum, the diameter of inhibition zone to Vitapex($42.33mm{\pm}17.2$) was largest and those to Calcium hydroxide paste(Pulpdent Tempcanal)($14.47mm{\pm}3.72$) and Zinc oxide eugenol cement($8.93mm{\pm}2.71$), Zinc phosphate cement($8.20mm{\pm}2.27$), Calcium hydroxide powder+D.D.W.($5.53mm{\pm}2.10$)was next orderly. And then In Zinc oxide eugenol cement and Zinc phosphate cement group, two of fifteen samples showed no inhibition zone, in Calcium hydroxide powder + D.D.W. group, 8 of 15 samples showed no inhibition zone.

  • PDF

Quantitative Analysis of Digital Radiography Pixel Values to absorbed Energy of Detector based on the X-Ray Energy Spectrum Model (X선 스펙트럼 모델을 이용한 DR 화소값과 디텍터 흡수에너지의 관계에 대한 정량적 분석)

  • Kim Do-Il;Kim Sung-Hyun;Ho Dong-Su;Choe Bo-young;Suh Tae-Suk;Lee Jae-Mun;Lee Hyoung-Koo
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.202-209
    • /
    • 2004
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed radiation energy. The visible light photons are converted into electric signal in the amorphous silicon photodiodes which constitute a two dimensional array. In order to produce good quality images, detailed behaviors of DR detectors to radiation must be studied. The relationship between air exposure and the DR outputs has been investigated in many studies. But this relationship was investigated under the condition of the fixed tube voltage. In this study, we investigated the relationship between the DR outputs and X-ray in terms of the absorbed energy in the detector rather than the air exposure using SPEC-l8, an X-ray energy spectrum model. Measured exposure was compared with calculated exposure for obtaining the inherent filtration that is a important input variable of SPEC-l8. The absorbed energy in the detector was calculated using algorithm of calculating the absorbed energy in the material and pixel values of real images under various conditions was obtained. The characteristic curve was obtained using the relationship of two parameter and the results were verified using phantoms made of water and aluminum. The pixel values of the phantom image were estimated and compared with the characteristic curve under various conditions. It was found that the relationship between the DR outputs and the absorbed energy in the detector was almost linear. In a experiment using the phantoms, the estimated pixel values agreed with the characteristic curve, although the effect of scattered photons introduced some errors. However, effect of a scattered X-ray must be studied because it was not included in the calculation algorithm. The result of this study can provide useful information about a pre-processing of digital radiography.

  • PDF

Effectiveness of Drain Insertion and Irrigation in the Treatment of Septic Arthritis of the Knee under Local Anesthesia (국소 마취하 배액관 삽입 및 세척을 통한 화농성 슬관절염의 치료의 효용성)

  • Yi, Jin Woong;Oh, Byung Hak;Heo, Youn Moo;Jang, Min Gu;Min, Young Ki;Seo, Kyung Deok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.4
    • /
    • pp.310-316
    • /
    • 2021
  • Purpose: Septic arthritis of the knee is an orthopedic emergency that requires early diagnosis and surgical treatment. This study examined the effectiveness of drain insertion and irrigation in the treatment of septic arthritis of the knee under local anesthesia. Materials and Methods: A retrospective study was conducted on nine cases (eight patients) diagnosed with septic arthritis of the knee from September 2017 to February 2020 and treated with drain insertion and irrigation under local anesthesia. After penetrating through the superolateral portal to the superomedial portal and inserting the drain, daily irrigation of approximately 3 L of normal saline was done. The following were investigated: age, sex, underlying disease, cause, degree of osteoarthritis, time from diagnosis to surgery, duration of hospitalization, duration of normalization of C-reactive protein, and smear and culture. Results: The initial white blood cell count of joint fluid was 71,472±51,667/mm3 (32,400-203,904/mm3), and polymorphic leukocytes were 91.1%±2.6% (86%-95%). The average time from diagnosis to surgery was 8.3±1.3 hours (6-10 hours), and the irrigation period was 8.2±3.2 days (4-15 days). The average length of hospitalization was 20.8±8.7 days (9-37 days). There was no reoperation or recurrence. Smear and culture tests were not identified. Conclusion: In the treatment of septic arthritis of the knee, the insertion of a drain tube and irrigation under local anesthesia is a relatively fast and simple method to reduce pain by repetitive draining of purulent joint fluid and can be used as an alternative treatment for patients with a risk of general or spinal anesthesia.

A Therapeutic Effect of Ozonated Oil on Bovine Mastitis (젖소 유방염에 대한 Ozonated oil의 치료효과)

  • Jo Sung-Nam;Liu Jianzhu;Lee Sang-Eun;Hong Min-Sung;Kim Duck-Hwan;Kim Myung-Cheol;Cho Sung-Whan;Jun Moo-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.22 no.4
    • /
    • pp.318-321
    • /
    • 2005
  • Forty- nine quarters from 24 lactating cows with chronic mastitis were selected. The cows were raised on dairy farms in Gongju, Jochiwon and Yeongi in Chungnam province, and Iksan in Jeonbuk province, Korea. The 49 quarters with bovine mastitis were divided into control (7 quarters) and experimental (42 quarters) groups. The experimental quarters were assigned to experimental group A (10 quarters, somatic cell count: $50-100\times10^4/ml)$, experimental group B (14 quarters, somatic cells count: $100-300{\times}10^4/ml)$, and experimental group C (18 quarters, somatic cells count: $>300\times10^4/ml$), according to the number of the somatic cells in their milk. The quarters of control group were treated with norfloxacin ointment (10 g/tube) based on the result of sensitivity, twice a day for 3 days. The quarters or experimental groups were infused 10ml or ozonated oils twice a day for 3 days. After treatment, the milk of the control group contained non-significantly lower numbers of somatic cells and bacteria on day 7, compared with pretreatment levels. Experimental groups A, B and C had lower somatic and bacterial cells in their milk on day 7, compared with pretreatment levels. Experimental group B and C had significantly lower numbers of somatic cells in their milk ell day 7 than before treatment (p<0.01). However, no significant difference in somatic cell numbers was detected between the control alld experimental groups. It was concluded that ozone therapy with ozonated oil applied on bovine mastitis might be effective.

Transformation of Nitrogen Derived from Solid Piggery Manure in Soil under Aerobic or Anaerobic Incubation Condition (혐기(嫌氣) 및 호기조건하(好氣條件下)에서 토양처리(土壤處理)된 돈분(豚糞) 중(中) 질소형태변화(窒素形態變化))

  • Yun, Sun-Gang;Jung, Kwang-Yong;Yoo, Sun-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.26 no.2
    • /
    • pp.121-126
    • /
    • 1993
  • The behaviors of inorganic nitrogen derived from solid animal waste in soil has been received too much concern partly because nitrate which occurred from nitrification can act as a pollutant to soil and groundwater and partly because the loss of nitrogen from surface soil by downward movement of water is disadvantageous in the view of plant nutrient. This present study was conducted to get fundamental imformations on nitrogen behavior and to provide improved basical concepts on the management of animal waste. Fresh or fermented pig manure was mixed with a sandy loam soil in the ratio of 2:1(soil:pig manure), packed into test tube and incubated at $30^+/-1^{\circ}C$ for 8 weeks under aerobic- or anaerobic condition. Sample tubes were taken at the one week interval and analyzed on pH, the amount of $CH_4$ produced under anaerobic condition and inorganic nitrogen. The pH of soil treated with fresh pig manure under anaerobic condition was lowered by 1.87 unit compared to that of under aerobic condition, but at the treatment with fermented pig manure, pH change was very little between aerobic and anaerobic condition. The coefficients of regressional equations which were obtained from pH and incubation time were -0.114 in fresh pig manure and -0.089 in fermented pig manure, and the extent of pH decrease due to incubation was greater in fresh pig manure than that of fermented pig waste. No differences in the amounts of $CH_4$ produced under anaerobic condition between fresh and fermented pig manure was observed until 3 weeks of incubation, however, after that the amount of $CH_4$ produced in fresh pig manure was abruptly increased and cumulative amont of $CH_4$ was reached 8.6 mole/g. K values on $CH_4$ production in fresh and fermented pig manure was 0.211 mole/g/day and 0.046 mole/g/day, respectively, for 5 weeks from the 3rd to the 8th week. $NH_4-N$ concentration at aerobic condition with fresh pig manure treatment was lowered by passing time of incubation, but $NO_3-N$ concentration was elevated from 11.2 ppm at initial state to 67.3 ppm after incubation and this trend on $NH_4-N$, $NO_3-N$ concentration was very similar to the treatment of fermented pig manure. While $NH_4-N$ concentration under anaerobic condition was greatly increased. $NO_3-N$ concentartion was not only very low but also no great changes, that was ranged from 4 to 8 ppm.

  • PDF