• 제목/요약/키워드: L-Tube

검색결과 794건 처리시간 0.025초

하절기 태양열 시스템 적용을 위한 이중진공관 히트파이프형 집열기 열성능의 실험적 연구 (An Experimental Study for Apply Solar System on Thermal Performance of Heat Pipe Type Solar Collector using a Glass Concentric Evacuated Tube in a Summer)

  • 강창호;배찬효;홍정규;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1646-1651
    • /
    • 2004
  • This paper has been carried out to find the thermal efficiency and operating characteristics of heatpipe type solar collector using a glass concentric evacuated tube(CETC) during summer. In an experiment the flow rate of water in collector are 1.5l/min. Collector efficiency is $50{\sim}60%$ during time. The solar radiation appeared in a clear day is efficiency high. Efficiency curve fitted first order polynomial show that $F_{R}$$({\tau}{\alpha})$ and $F_{R}U_{L}$=1.316 is 0.601 and 1.316 respectively.

  • PDF

Clinical In Vivo Bio Assay of Glucose in Human Skin by a Tattoo Film Carbon Nano Tube Sensor

  • Ly, Suw Young;Lee, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제34권3호
    • /
    • pp.595-601
    • /
    • 2017
  • In vivo assay of glucose detection was described using a skin tattoo film electrode (STF), and the probe was made from carbon nano tube paste modification film paper. Here in the square-wave stripping anodic working range obtained of $20-100mgL^{-1}$ within an accumulation time of 0 seconds only in sea water electrolyte solutions of pH 7.0. The relative standard deviations of 50 mg glucose that were observed of 0.14 % (n=12), respectively, using optimum stripping accumulation of 30 sec, the low detection limit (S/N) was pegged at 15.8 mg/L. The developed results can be applied to the detect of in vivo skin sensing in real time. Which confirms the results are usable for in vitro or vivo diagnostic clinical analysis.

3포트 ER 밸브 개발을 위한 분산계 ER유체의 유동특성에 관한 연구 (A Study on Flow Characteristics of Dispersive ER Fluids for Development of 3-port ER Valves)

  • 장문제;장성철;염만오;이동극;김기홍
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.125-131
    • /
    • 2005
  • The purpose of the present study is to examine the flow characteristics of ER fluids between 2 port and 3 port rectangular tube brass electrodes. ER fluid is made silicon oil mixed with $2-3wt\%$ starch having hydrous particles. Flow visualization of the ER fluids were obtained by CCD camera measuring those of the clusters using an image processing technique. This research found the flow $rate(Q_L)$ with 0 kV /mm, 0.5kV/mm and 1.0kV/mm for $Q_L\;=\;0,\;0$ and $5.73cm^3/s$. When the strength of the electric field increased, the cluster of ER fluids are clearly strong along the rectangular tube and the flow rate(Q) decreased.

  • PDF

Fast initialization of a F!T tube

  • Willemsen, Oscar H.;Hoppenbrouwers, Jurgen J.L.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.122-125
    • /
    • 2003
  • We describe a new method to initialize the raster and convergence of a flat intelligent tracking (F!T) tube. By splitting up the initialization algorithm into three parts, it can comply with the variety of boundary conditions that are stated for a consumer product. Experiments on raster initialization have shown that the new algorithm speeds up the initialization by one order of magnitude.

  • PDF

$CO_2$ 흡수용 $100Nm^3$/hr급 Vortex Tube의 에너지분리 특성에 관한 실험적 연구 (An Experimental Study on the Energy Separation of the $100Nm^3$/hr Vortex Tube for $CO_2$ Absorption)

  • 김창수;한근희;박성영
    • 청정기술
    • /
    • 제16권3호
    • /
    • pp.213-219
    • /
    • 2010
  • 볼텍스튜브는 고압의 가스를 이용하여 고온 가스와 저온 가스를 분리하거나 입자상 물질의 분리에 사용할 수 있는 장치이다. 이러한 볼텍스튜브의 에너지분리 특성과 물질분리 특성을 활용하여, 연소가스로부터 $CO_2$를 흡수하는 장치의 핵심부품으로 적용할 수 있다. 본 연구에서는 $CO_2$ 흡수용 볼텍스튜브의 기본설계 자료를 구축하기 위하여 에너지분리 성능실험을 수행하였다. 설계를 위한 기초 자료를 확보하기 위하여, 볼텍스 발생기의 오리피스 직경, 노즐면적비 및 튜브의 길이가 에너지분리 특성에 미치는 영향력을 실험을 통하여 분석하였다. 결과적으로 오리피스 직경이 볼텍스튜브의 성능에 지배적인 설계인자임을 확인하였으며, 노즐면적비와 튜브길이의 영향력은 미미하였다. 오리피스 직경이 작고(Dc=0.6D), 노즐면적비가 중간 이상(AR=0.14~0.16)이며, 튜브 길이가 긴 모델(L=16D)이 저온 출구 측과 고온 출구 측의 열전달에서 가장 우수한 성능을 나타내었다. 본 연구의 결과는 $CO_2$흡수용 $100Nm^3$/hr급 볼텍스튜브의 기본설계 자료로 활용될 예정이다. 볼텍스튜브를 적용한 $CO_2$흡수 공정을 적용하면 기존의 대형 흡수탑 대비 상당한 공간과 에너지의 절감 효과가 기대된다.

외부 튜브 길이가 긴 수직 환상공간 내부의 풀비등 열전달 (Pool Boiling Heat Transfer in a Vertical Annulus with a Longer Outside Tube)

  • 강명기
    • 대한기계학회논문집B
    • /
    • 제36권8호
    • /
    • pp.775-782
    • /
    • 2012
  • 수직으로 설치된 하부폐쇄 환상공간 내부의 풀비등 열전달 메카니즘을 알기 위하여 환상공간의 튜브 길이를 0.3m와 0.6m 사이에서 변경하였다. 실험을 위해 0.2m의 가열 길이를 갖는 직경 19.1mm인 스테인리스강 튜브와 대기압 상태 하에 있는 물을 사용하였다. 외부 튜브 길이가 열전달에 미치는 영향을 분명하게 살펴보기 위해 환상공간에 대한 결과를 환상공간이 없는 단일튜브에 대한 결과와 서로 비교하였다. 동일 열유속에서 외부튜브 길이의 증가는 틈새간격이 3.5mm인 경우에는 열전달계수의 증가하지만 틈새간격이 15.5mm인 경우에는 열전달계수가 감소하였다. 이러한 경향의 주된 원인은 액체교란의 차이로서 설명된다.

수직 액막형 흡수기의 성능 최적화에 관한 연구 (Study on the Optimization of Absorption Performance of the Vertical Tube Absorber with Falling Film)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제17권9호
    • /
    • pp.830-838
    • /
    • 2005
  • The present study investigated the optimization of the absorption performance of the vertical absorber tube with falling film by considering heat and mass transfer simultaneously. Effects of film Reynolds number, geometric parameters by insert device (spring) and flow pattern on heat and mass transfer performances have been also investigated. Especially, effects of coolant flow rate and the flow pattern by geometric parameters has been observed for the total heat and mass transfer rates through both numerical and experimental studies. Based on both predicted values, the optimal coolant flow rate was predicted as 1.98 L/min. The maximum absorption rate of the spring inserted tube was increased by the maximum of $20.0\%$ than those for uniform film of bare tube. Average Sherwood numbers and Nusselt numbers were increased as Reynolds numbers increased under the dynamic and geometric conditions showing the maximum absorption performance.

Convective Boiling of R-l34a in a Bundle of Smooth Tubes

  • Kim, Jung-Oh;Cho, Jin-Pyo;Kim, Nae-Hyun;Choi, Kuk-Kwang
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제10권2호
    • /
    • pp.79-87
    • /
    • 2002
  • In this study, flow boiling experiments were performed using R-134a on a plain tube bundle. Tests were conducted for the following range of variables; quality from 0.1 to 0.9, mass flux from 8kg/$m^2$s to 26 kg/$m^2$s and heat flux from 10kW/$m^2$ to 40kW/$m^2$. The heat transfer coefficients were strongly dependent on the heat flux. However, they were almost independent on the mass flux or quality. The data are compared with the modified Chen model, which predicted satisfactorily ($\pm$30%) the data. The Original Chen model, however, did not adequately predict the effect of quality. The reason may be attributed to the flow pattern of the present test, where the bubbly flow prevailed for the entire test range. The heat transfer coefficients of the tube bundle were 6~40% higher than those of the single tube pool boiling.

수처리용 유전체장벽 플라즈마 반응기에 대한 기초 연구 (A Basic Study of Plasma Reactor of Dielectric Barrier Discharge for the Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제20권5호
    • /
    • pp.623-630
    • /
    • 2011
  • This study investigated the degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) by using dielectric barrier discharge (DBD) plasma. The DBD plasma reactor of this study consisted of a quartz dielectric tube, titanium discharge (inner) and ground (outer) electrode. The effect of shape (rod, spring and pipe) of ground electrode, diameter (9~30 mm) of ground electrode of spring shape and inside diameter (4~13 mm) of quartz tube, electrode diameter (1~4 mm), electrode materials (SUS, Ti, iron, Cu and W), height difference of discharge and ground electrode (1~15.5 cm) and gas flow rate (1~7 L/min) were evaluated. The experimental results showed that shape of ground electrode and materials of ground and discharge electrode were not influenced the RNO degradation. The thinner the diameter of discharge and ground electrode, the higher RNO degradation rate observed. The effect of height gap of discharge between ground electrode on RNO degradation was not high within the experimented value. Among the experimented parameters, inside diameter of quartz tube and gas flow rate were most important parameters which are influenced the decomposition of RNO. Optimum inside diameter of quartz tube and gas flow rate were 7 mm and 4 L/min, respectively.

엇갈림 관군에서 원관 주위의 열전달에 미치는 파울링 영향에 관한 실험적 연구 (An Experimental Study of Fouling Effect on the Heat Transfer Around a Tube in Staggered Tube Banks)

  • 김민수;백병준;박복춘
    • 대한기계학회논문집B
    • /
    • 제24권11호
    • /
    • pp.1478-1485
    • /
    • 2000
  • An experimental study has been performed to investigated the forced convection heat transfer characteristics of 6 circular cylinders in staggered arrangement in a cross flow of air. The water scale deposited on condenser wall of power plant was used to investigate the effect of roughness of scaled surfaces. The relative roughness*average diameter of scale/cylinder diameter) was in a range of k/d=0.0066, 0.0111, 0.0167, 0.0222 and 0.0278. The cylinder spacings(L/d) varies from 1.5 to 4.0 where L denote the cylinder spacings along and normal to the upstream uniform flow direction. The Reynolds number was varied in a range of 10, 000$\leq$ Re $\leq$ 50,000. The local and mean Nusselt numbers were investigated as a function of scale roughness, the cylinder spacing and Reynolds number. The results are compared with those of clean cylinder and inline tube bank, subsequently the mean fouling resistance over the entire circumference was estimated from those results as a function of scale roughness, the cylinder spacing and Reynolds number.