• Title/Summary/Keyword: L-Mode

Search Result 1,512, Processing Time 0.027 seconds

Nondestructive bending Strength Evaluation of Woodceramics Using Resonance Frequency Mode (I) - Carbonizing Temperature -

  • Byeon, Hee-Seop;Ahn, Sang-Yeol;Oh, Seung-Won;Piao, Jin-Ji
    • Journal of the Korean Wood Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.8-14
    • /
    • 2004
  • Nondestructive evaluation (NDE) technique method using a resonance frequency mode was carried out for woodceramics produced at different carbonizing temperatures (600℃, 800℃, 1000℃, 1200℃, 1500℃) at the phenol resin impregnation rate of 70%, for three kinds of species (Pinus densifora, Pinus koraiensis, Larix leptolepis), respectively. There was a poor relationship between density and static bending MOR. However, close correlations were found between dynamic MOEd and static bending MOR, and between static MOEs and MOR. Especially, the correlation coefficient was highest between MOEd and static bending MOR. Therefore, the MOEd using the resonance frequency mode is useful as a NDE method for predicting the MOR of woodceramics produced at different carbonizing temperatures.

Lasing mode and Beam Profile Analysis of DFB Laser with an Anti-reflection Coated Mirror (무반사 면을 갖는 DFB 레이저의 발진 모드와 빔 분포 해석)

  • Kwon, Keeyoung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.727-732
    • /
    • 2020
  • In this paper, when a refractive index grating and a gain grating were simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, a dielectric film coating was applied so that reflection did not occur on the right mirror surface, so that 𝜌r=0. In case of δL > 0, the threshold gain and the beam distribution in the longitudinal direction and the radiated power ratio Pl/Pr of the oscillation mode were compared for the cases of the phase of 𝜌l=π and π/2. If the phase of 𝜌l=π, in order to obtain a low threshold current and high frequency stability, κL should be greater than 8. In the case of the phase of 𝜌l= π/2, when κL is larger than 4.0, the oscillation gain starts to be lower than when the phase of 𝜌l=π. In order to lower the threshold current of a oscillation mode and enhance the frequency stability, κL should be greater than 8.

An Interactive Robotic Cane for Blind Travelers

  • Shim, Inbo;Yoon, Joongsun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.119.6-119
    • /
    • 2002
  • $\textbullet$ Introduction $\textbullet$ A Robotic Cane "RoJi" $\textbullet$ Shared Navigation Control $\textbullet$ Autonomous Control Mode $\textbullet$ User Control Mode $\textbullet$ Navigation $\textbullet$ Summary

  • PDF

Evaluation and Test of Slenderness Ratio Effect on Buckling Characteristics of Thin Cylindrical Structures Subjecting the Shear Loads (전단하중을 받는 얇은 원통구조물의 세장비에 따른 좌굴특성 평가 및 시험)

  • 구경회;김종범;이재한
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.3
    • /
    • pp.535-543
    • /
    • 2002
  • The purpose of this paper is to investigate the slenderness ratio effect on buckling characteristics of thin cylindrical structures subjecting the shear loads in detail. To do this, the buckling strength evaluations were carried out with using the evaluation formulae proposed by J. Okada. From the results of the buckling strength evaluations, the three types of staled cylindrical test specimen, which have L/R=3.1, 1.6, and 1.0, are determined for the numerical analyses and tests. From results, target slenderness ratio over L/R=3 results in dominant bending buckling mode, smaller slenderness ratio under L/R=1 results in dominant shear buckling mode, and near L/R=1.6 region shows the mixed buckling mode which has the bending and shear buckling mode simultaneously. Most results of buckling characteristics obtained by the numerical analyses and the evaluation formulae we in good agreement with those of tests.

Numerical Study on the Effect of Changes of Geometric Shape of Diesel Particulate Filter on Light-Off Characteristics and Transient Thermal Behavior during Regeneration (디젤입자상물질필터의 기하학적 형상변화가 재생과정 중 활성화 특성 및 비정상 온도거동에 미치는 영향에 관한 수치적 연구)

  • Jeong, Soo-Jin;Lee, Sang-Jin;Kim, Woo-Seung;Lee, Chun-Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.68-76
    • /
    • 2006
  • The minimization of maximum DPF wall temperature and the fast Light-off during regeneration are the targets for the high durability of the DPF system and the high efficiency of regeneration. In order to predict transient thermal response of DPF, one-channel numerical modeling has been adopted. The effect of the ratio of length to diameter(L/D), cell density, the amount of soot loading on temporal thermal response and regeneration characteristics has been numerically investigated under two different running conditions: city driving mode and high speed mode. The results indicate that the maximum wall temperature of DPF increase with increasing 'L/D' in 'High speed mode'. For 'City driving mode', the maximum wall temperature decreases with increasing 'L/D' in the range of $'L/D{\geq}0.6'$. The maximum temperature decreases with increasing cell density because heat conduction and heat capacity are increased. It is also found that the effect of amount of soot loading on light-off time is negligible.

Design and Fabrication of Flat-Type $L_{1}-B_{8}$ Mode Ultrasonic Motors (평판형 $L_{1}-B_{8}$ 모드 초음파 전동기의 설계 및 제작)

  • U, Sang-Ho;Kim, Woo-Tae;Shin, Soon-In;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11b
    • /
    • pp.414-417
    • /
    • 2001
  • Recently, developments of device using characteristics of ceramics as a new technical material is in progress. While doing so, Ultrasonic motor which is a part of research & development of piezo-actuator by piezo-effects is being used in the various applications. So, we fabricated a flat-type $L_{1}-B_{8}$ mode Ultrasonic motor and measured the operation characteristics of its. The size of USM is 80*20*1.5[$mm^{3}$](length*width*thickness) and is constructed with stator by piezo-ceramics and stainless elastic body and rotator by bearings. As results of experiments, the fastest speed of revolution(v), the maximum torque(T) and the efficiency( $\eta$ ) were 37.5[cm/sec], 5.0[ $mN{\cdot}m$ ] and 1.17[%] respectively when 27.9[kHz], 150[gf], 50[V] were applied. So, we think this $flat-type_{1}-B_{8}$ mode Ultrasonic motor is able to be used for applications in forwarding device of a paper or electric card and so on.

  • PDF

MODE CONTROL OF GUIDED WAVE IN MAGNETIC HOLLOW CYLINDER USING ELECTROMAGNETIC ACOUSTIC TRANSDUCER ARRAY

  • FURUSAWA, AKINORI;KOJIMA, FUMIO;MORIKAWA, ATSUSHI
    • Nuclear Engineering and Technology
    • /
    • v.47 no.2
    • /
    • pp.196-203
    • /
    • 2015
  • The aim of this work is to demonstrate a method for exciting and receiving torsional and longitudinal mode guided waves with an electromagnetic acoustic transducer (EMAT) ring array. First of all, a three-dimensional guided wave simulator is developed in order to numerically analyze the propagation of the guided wave. The finite difference time domain method is used for the simulator. Second, two guided wave testing systems using an EMAT ring array are provided: one is for torsional mode (T-mode) guided wave and the other is for longitudinal mode (L-mode). The EMATs used in the both systems are the same in design. A method to generate and receive the T- and L-mode guided waves with the same EMAT is proposed. Finally, experimental and numerical results are compared and discussed. The results of experiments and simulation agree well, showing the potential of the EMAT ring array as a mode controllable guided wave transmitter and receiver.

E-H Mode Transition Properties of Cylindrical ICP Hg:Kr

  • Yang Jong-Kyung;Pack Kwang-Hyun;Lee Jong-Chan;Park Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.124-130
    • /
    • 2005
  • In this paper, we designed a cylindrical type light source having an electromagnetic principle of inductively coupled plasma, and measured its electrical-optical properties. Using the transformer principle, an electrically equivalent circuit cylindrical type light source was analyzed. According to the parameters of electromagnetic induction, which were diameter of coil with cpO.3$\~$ 1.2mm, number of turns with 4$\~$ 12 turns, distance with 40$\~$ l20mm and RF power with 10$\~$ 150W, the electrical .md optical properties were measured. When the diameter of the coil was cp0.3mm, number of turns was 8 and distance was 40mm, and the maximum brightness of 29,730 cd/m$^{2}$ was shown with RF power l50W. The relationship between electromagnetic induction and plasma discharges was demonstrated using the mode transition from E-mode to H-mode

L2/L3 based Proxy Scheme for Sleepy Node In IoT (IoT에서 L2/L3 기반 Sleepy Node 지원 기법)

  • Youn, JooSang;Hong, Yong-Geun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.01a
    • /
    • pp.65-66
    • /
    • 2014
  • 본 논문에서는 IoT 환경에서 자주 발생하는 작은 디바이스의 sleep mode 동작의 문제점을 정의하고 이를 해결하기 위한 L2/L3 기반 데이터 전송 및 전달 기법을 제안한다. 본 논문에서 논하는 이슈는 현재 IETF lwig WG에서 위제로 다루어지는 지고 있다. 기존 인터넷 프로토콜은 현재 sleepy node를 지원하는 방법이 없다. 따라서 타겟 노드가 sleep mode로 동작할 경우 메시지 손실이 발생하며 이를 혼잡 손실로 판단하여 불필요한 재전송을 수행하게 된다. 이는 CN의 에너지 사용 측면에서 비효율적이다. 따라서 본 논문에서는 이런 문제를 극복하기 위해서 L2/L3 기능만으로 sleepy node를 지원하는 기법을 제안하며 제안된 기법은 기존 인터넷 프로토콜의 수정 없이 낮은 오버헤드로 동작할 수 있는 기법이다.

  • PDF

Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography (전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가)

  • Kim, Jeong Jin;Jang, Seong Won;Park, Jang Heum;Lee, Kwan Seob;Ha, Dong Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF