• 제목/요약/키워드: L-C Resonance

검색결과 199건 처리시간 0.031초

Radiographic Parameters of Segmental Instability in Lumbar Spine Using Kinetic MRI

  • Jang, Se-Youn;Kong, Min-Ho;Hymanson, Henry J.;Jin, Tae-Kyung;Song, Kwan-Young;Wang, Jeffrey C.
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권1호
    • /
    • pp.24-31
    • /
    • 2009
  • Objective : To investigate the effectiveness of radiographic parameters on segmental instability in the lumbar spine using Kinetic magnetic resonance imaging (MRI). Methods : Segmental motion, defined as excessive (more than 3 mm) translational motion from flexion to extension, was investigated in 309 subjects (927 segments) using Kinetic MRI. Radiographic parameters which can help indicate segmental instability include disc degeneration (DD), facet joint osteoarthritis (FJO), and ligament flavum hypertrophy (LFH). These three radiographic parameters were simultaneously evaluated, and the combinations corresponding to significant segmental instability at each level were determined. Results : The overall incidence of segmental instability was 10.5% at L3-L4, 16.5% at L4-L5, and 7.3% at L5-S1. DD and LFH at L3-L4 and FJO and LFH at L4-L5 were individually associated with segmental instability (p<0.05). At L4-L5, the following combinations had a higher incidence of segmental instability (p<0.05) when compared to other segments : (1) Grade IV DD with grade 3 FJO, (2) Grade 2 or 3 FJO with the presence of LFH, and (3) Grade IV DD with the presence of LFH. At L5-S1, the group with Grade III disc and Grade 3 FJO had a higher incidence of segmental instability than the group with Grade I or II DD and Grade 1 FJO. Conclusion : This study showed that the presences of either Grade IV DD or grade 3 FJO with LFH at L4-L5 were good indicators for segmental instability. Therefore, using these parameters simultaneously in patients with segmental instability would be useful for determining candidacy for surgical treatment.

AE 기법을 이용한 외부수압을 받는 복합재 원통의 균열 검출 (Crack Detection of Composite Cylinders under external pressure using the Acoustic Emission)

  • 박진하;최진호;권진회
    • Composites Research
    • /
    • 제24권3호
    • /
    • pp.25-30
    • /
    • 2011
  • 복합재료의 비파괴 검사 방법에 관한 연구는 복합재료의 신뢰성 및 안전성을 개선시키는데 매우 중요하다. AE기법은 소성변형, 섬유파손, 모재균열 또는 박리에 의해 생성되는 탄성파에서 감지되는 변형 에너지를 감지하여 결함을 평가하는 기법이다. 본 논문에서는 외부 수압을 받는 필라멘트 와인딩 복합재 원통과 샌드위치 원통의 수압시험이 수행되었고, PVDF센서로부터 측정된 AE 신호특성을 분석하였다. 또한, L-C 동조회로와 Band-pass filter 회로를 가진 AE 신호분석기를 설계, 제작 하였으며, 필라멘트 와인딩 원통과 샌드위치 원통에 대한 수압실험에서 제작된 AE 신호분석기의 균열 검출 능력을 평가하였다.

유공방파제의 반사특성에 관한 수리실험 (Hydraulic Experiments for the Reflection Characteristics of Perforated Breakwaters)

  • 박우선;전인식;이달수
    • 한국해안해양공학회지
    • /
    • 제5권3호
    • /
    • pp.198-203
    • /
    • 1993
  • 유공방파제의 반사특성을 규명하기 위하여 파고 및 주기가 다른 여러 규칙파를 대상으로 유수실의 폭과 유공벽의 형태를 변화시키며 수리실험을 수행하였다. 실험결과, 유공방파제의 반사특성은 유수실 폭과 유수실내 파장의 비(B/L$_{c}$)에 민감하게 반응하며, B/L$_{c}$가 0.2인 부근에서 최소의 반사율을 보임을 알 수 있었다. 이러한 현상은 주로 유수실내에서의 공진현상에 기인한 것으로 판단된다. 유공벽형태(종슬리트, 횡슬리트 또는 원형 구멍)의 변화는 반사율면에 있어서 약간의 변화를 초래할 수는 있어도, 전반적인 반사특성 변화에는 영향을 주지 못함을 확인하였다.하였다.

  • PDF

Estimation of Ground and Excited State Dipole Moments of Coumarin 450 by Solvatochromic Shift Method

  • Naik, L.R.;Math, N.N.
    • Journal of Photoscience
    • /
    • 제12권2호
    • /
    • pp.57-61
    • /
    • 2005
  • The ground and excited state dipole moments of Coumarin 450 (C 450) laser dye were measured at room temperature in several solvents of varying dipole moments. The ground state dipole moment (${\mu}_g$) is estimated by using the modified Onsagar model and the excited state dipole moments (${\mu}_e$) were estimated by the method of solvatochromism as well as by utilizing the microscopic solvent polarity parameter ($E^N_T$). Further, the deviation of some of the points from the linearity of the $E^N_T$ versus Stokes shift indicates the existence of specific type of solute-solvent interaction. The excited state dipole moment of C 450 were found to be higher than those of the ground state and is interpreted in terms of the resonance structure of the molecule. A reasonable agreement has been observed between the values obtained by the method of solvatochromism and modified Onsagar model. It is observed that, corresponding to cyclohexane solution, the fluorescence maxima shift towards the red region with increasing the polarity of the solvents, hence the transition involved are of ${\pi}-{\pi}^*$ type.

  • PDF

Ultrafast Investigation of Vibrational Relaxation and Solvent Coordination Following Photodissociation of Cr$(CO)_6$

  • Seok-Beum Ko;Soo-Chang Yu;J. B. Hopkins
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권9호
    • /
    • pp.762-765
    • /
    • 1994
  • Picosecond time-resolved resonance Raman spectroscopy has been used to study the photochemistry of Cr(CO$)_6$ in cyclohexane following photoexcitation at 266 nm. Photodissociative loss of CO is found to occur within our pulse width of ${\leq}$5 ps by probing the 533 c$m^{-1}$ vibrational mode of ground state Cr(CO$)_6$. The subsequent dynamics after photodissociation are interpreted in terms of solvation, vibrational and electronic relaxations. The vibrational relaxation time of 100 ps and 83 ps are observed by monitoring v=O and v=l of the 381 c$m^{-1}$ transient mode, respectively. No evidence was found for solvation and electronic relaxation occurring on a time scale of ${\leq}$5 ps.

코일의 감은 횟수에 따른 초전도 무선전력전송 시스템 특성 분석 (Analysis of the Superconducting Wireless Power Transmission System Characteristics according to the Number of Turns of the Coil)

  • 박노아;최효상;정인성;최혜원
    • 전기학회논문지
    • /
    • 제67권3호
    • /
    • pp.485-489
    • /
    • 2018
  • Studies have been actively conducted on the magnetic-resonance wireless power transmission (WPT) for commercialization. Such studies are essential for improving the transmission efficiency. In the magnetic-resonance WPT, the inductance (L) and capacitance (C) vary significantly depending on the design of the coils, and the efficiency sharply changes accordingly. To address this problem, studies on the coil design are required. In this study, the S-parameter characteristics according to the number of turns of the coil were analyzed to improve the efficiency of the superconducting WPT. Superconducting coils were designed, and the reflection coefficient ($S_{11}$) according to the turns was analyzed. It was confirmed that the power transmission characteristics were improved as the reactance approached $0{\Omega}$

3차원 공동의 폭변화에 따른 초음속 유동에 대한 수치분석연구 (NUMERICAL ANALYSIS OF THREE DIMENSIONAL SUPERSONIC CAVITY FLOW FOR THE VARIATION OF CAVITY SPANWISE RATIO)

  • 우철훈;김재수;최홍일
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 추계 학술대회논문집
    • /
    • pp.181-184
    • /
    • 2006
  • High-speed flight vehicle have various cavities. The supersonic cavity flow is complicated due to vortices, flow separation and reattachment, shock and expansion waves. The general cavity flow phenomena include the formation and dissipation of vortices, which induce oscillation and noise. The oscillation and noise greatly affect flow control, chemical reaction, and heat transfer processes. The supersonic cavity' flow with high Reynolds number is characterized by the pressure oscillation due to turbulent shear layer, cavity geometry, and resonance phenomenon based on external flow conditions, The resonance phenomena can damage the structures around the cavity and negatively affect aerodynamic performance and stability. In the present study, we performed numerical analysis of cavities by applying the unsteady, compressible three dimensional Reynolds-Averaged Navier-Stokes(RANS) equations with the ${\kappa}-{\omega}$ turbulence model. The cavity model used for numerical calculation had a depth(D) of 15mm cavity aspect ratio(L/D) of 3, width to spanwise ratio(W/D) of 1.0 to 5.0. Based on the PSD(Power Spectral Density) and CSD(Cross Spectral Density) analysis of the pressure variation, the dominant frequency was analyized and compared with the results of Rossiter's Eq.

  • PDF

공동의 폭 변화에 따른 3차원 초음속 공동 유동연구 (NUMERICAL ANALYSIS OF THREE DIMENSIONAL SUPERSONIC CAVITY FLOW FOR THE VARIATION OF CAVITY SPANWISE RATIO)

  • 우철훈;김재수
    • 한국전산유체공학회지
    • /
    • 제11권4호
    • /
    • pp.62-66
    • /
    • 2006
  • High-speed flight vehicle have various cavities. The supersonic cavity flow is complicated due to vortices, flow separation, reattachment, shock waves and expansion waves. The general cavity flow phenomena includes the formation and dissipation of vortices, which induce oscillation and noise. The oscillation and noise greatly affect flow control, chemical reaction, and heat transfer processes. The supersonic cavity flow with high Reynolds number is characterized by the pressure oscillation due to turbulent shear layer, cavity geometry, and resonance phenomenon based on external flow conditions. The resonance phenomena can damage the structures around the cavity and negatively affect aerodynamic performance and stability. In the present study, we performed numerical analysis of cavities by applying the unsteady, compressible three dimensional Reynolds-Averaged Navier-Stokes(RANS) equations with the ${\kappa}-{\omega}$ turbulence model. The cavity model used for numerical calculation had a depth(D) of 15mm cavity aspect ratio (L/D) of 3, width to spanwise ratio(W/D) of 1.0 to 5.0. Based on the PSD(Power Spectral Density) and CSD(Cross Spectral Density) analysis of the pressure variation, the dominant frequency was analyzed and compared with the results of Rossiter's Eq.

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

RF Integrated Electromagnetic-Noise Filters Incorporated with Nano-granular Co41Fe38AI13O8 Soft Magnetic Thin Films on Coplanar Transmission Line

  • Sohn, Jae-Cheon;Yamaguchi Masahiro;Lim, Sang-Ho;Han, Suk-Hee
    • Journal of Magnetics
    • /
    • 제10권4호
    • /
    • pp.163-170
    • /
    • 2005
  • The RF integrated noise filters are fabricated by photolithography. The stack for the electromagnetic noise filters consists of the nano-granular ($Co_{41}Fe_{38}AI_{13}O_8$) soft magnetic film / $SiO_2$ / Cu transmission line / seed layer (Cu/Ti) / $SiO_2$-substrate. A good signal-attenuation feature along with a low signal-reflection feature is observed in the present filters. Especially in the noise filter incorporated with a $Co_{41}Fe_{38}AI_{13}O_8$ magnetic film with lateral dimensions of $2000{\mu}m$ wide, 15 mm long and $1{\mu}m$ thick, the maximum magnitude of signal attenuation reaches -55 dB, and the magnitude of signal reflection is below -10 dB in the overall frequency range. And this level of signal attenuation is much larger than that of a noise filter incorporated with a Fe magnetic film.