• Title/Summary/Keyword: L-지표

Search Result 1,354, Processing Time 0.025 seconds

Changes of Physicochemical Characteristics and Development of New Quality Indices for Industry-produced Koji Kochujang (공장산 고오지 고추장의 이화학적 특성변화 및 품질지표 개발)

  • Kim, Young-Soo;Cha, Jin;Jung, Sung-Won;Park, Eun-Ji;Kim, Jung-Ok
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.453-458
    • /
    • 1994
  • 43 Kinds of physicochemical characteristics of koji kochujang prepared by a standardized industrial process were determined and analyzed statistically during storage for 105 days at $37^{\circ}C$. The characteristics which showed significant correlation with storage period after preparation of kochujang were 12 items, which included sensory preference for flavor and taste, Hunter tristimulus values($L,\;a,\;b,\;{\{\delta}E$), HMF, capsanthin, formol nitrogen, threonine, water and water activity. Seven of the items were related with color attributes of kochujang. Especially, tristimulus values showed significant correlation with sensory preference for color of kochujang. In this regard, tristimulus values should be recommended as new quality indices of national standard for industry-produced koji kochujang. Means and standard deviations of tristimulus values of 27 kinds of industry-produced koji kochujang in the market were $28.21{\pm}1.48,\;a=9.37{\pm}2.54,\;b=4.35{\pm}2.19\;and\;{\delta}E=30.09{\pm}2.42.$.

  • PDF

Evaluation of the Present Management Conditions for the Facilities in Moodeung-san Provincial Park (무등산(無等山) 도립공원(道立公園) 시설물(施設物)의 관리상태(管理狀態) 평가(評價)와 개선방안(改善方案))

  • Kim, Sang-Oh;Oh, Kwang-In
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.4
    • /
    • pp.590-600
    • /
    • 1998
  • This study applied the normative approach to establish evaluative standards for the facilities in Moodeung-san Provincial Park. Based on the established evaluative standards, this study examined the present facility managerial conditions of the park, and suggested some management alternatives to solve the identified problems. Data were collected by on-site survey and a mail-back questionnaire during August of 1996 in Moodeung-san Provincial Park. Out of 1,173, 519 respondents (44.2%) were used for the analysis. According to the results, three indicators out of five established indicators except 'adequacy of garbage cans' and 'adequacy of trail-guidance facilities' were in worse conditions than the established evaluative standards. The three indicators were 1) adequacy of toilets, 2) cleanness of toilets, 3) waiting time for using public transportations. The present condition for 'adequacy of trail-guidance facilities' was the same with the evaluative standard. This study suggested some management strategies to improve these problematic conditions, and introduced how managers may use these information for the facility management of the park.

  • PDF

Total Coliforms and Fecal Coliforms as Microbial Indicators of Waterborne Enteric Viruses in Korean Surface Water (한국 지표수에서 수인성 장관계 바이러스에 대한 지표 미생물로서 총 대장균군과 분원성 대장균군)

  • Lee, Gyucheol;Lee, Heesuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.6
    • /
    • pp.885-892
    • /
    • 2006
  • In order to investigate whether or not Total Coliforms (T.C.) and Fecal Coliforms (F.C.) are compatible as indicator microorganisms of waterbome enteric viruses, a total of 192 surface water samples from 24 locations in Korea were tested for T.C., F.C., and human enteric viruses from July 2003 to January 2006. Altogether, the number of T.C. in each samples was ranged from $0{\sim}5.3{\times}10^4$ colony forming unit(CFU)/100mL, and the number of F.C. ranged from $0{\sim}5.0{\times}10^3CFU/100mL$ per sample. Thirty-three percent of the samples tested positive for human enteric viruses after the total culturable virus assay. The results of the statistical analysis showed that T.C. and F.C. had a significant correlation with turbidity and temperature, but the waterbome enteric viruses did not. When compared to the number of T.C. or F.C. per sample, the concentration of waterbome enteric viruses was not found to be correlated. In conclusion, it is suggested that T.C. and F.C. may not be sufficient microbial indicators of waterbome enteric viruses in the samples analyzed in this study. However, further research is needed to find other microbial indicators of waterbome enteric viruses and to develop more advanced and sensitive methods to detect waterborne enteric viruses.

The Effects of Misutkaru Water Drink on Relieving Constipation and Physiological Measurements: A Preliminary Study for the Development of Convergent Misutkaru Water Drink Intake Program in Patients with Hemodialysis (혈액 투석 환자의 변비 완화 및 생리적 지표 향상을 위한 융합형 미숫가루 음용 섭취 프로그램 개발 예비 조사)

  • Shin, Na-yeon;Park, Hyo-sun
    • Journal of Convergence for Information Technology
    • /
    • v.9 no.5
    • /
    • pp.40-47
    • /
    • 2019
  • The purpose of this study aimed to develop the misutkaru water drink intake program that was possible to compare the effects of misutkaru drink on relieving constipation and physiological measurementson relieving constipation of the patients with hemodialysis. This study was non-equivalent control group pretest-posttest design with 42 patients in a general hospital in S city, Korea. During the experiment, the participants had to drink misutkaru water in the morning and past the 7 days after intake as constipation assessment scale, potassium and phosphorus were measured. The data were examine using t-test, Fisher's exact test, paired t-test. After misutkaru drinking intervention, constipation (z=-2.66, p=.002) decreased significantly improvement. This suggests that misutkaru water drinking intervention improved constipation in patients with hemodialysis.

Quality of Surface Water for lrrigation around Controlled Horticultural Area in Gyeongnam (경남지방 시설원예지 농업용 지표수의 수질 현황)

  • Heo, Jong-Soo;Ha, Yeong-Rae;Seo, Jeoung-Yoon;Cho, Ju-Sik;Lee, Sung-Tae;Lee, Hong-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.4
    • /
    • pp.356-364
    • /
    • 1997
  • To investigate the water quality status of agricultural water source for greenhouse area in Gyeongnam, the surface water quality was examined six times from October in 1995 to March in 1996 at five areas in Gyeongnam. The pH values of surface water were in the range of 6.6${\sim}$9.1 pH in Kimhae and Changnyong areas were out of range in 6.0${\sim}$8.5 which was water quality standard for agriculture. The DO values of surface water were relatively high with average 10.0mg/l in Kimhae, Changnyong, Sacheon and Chinju areas except for Haman area. The BOD values of surface water exceeded water quality standard for agriculture(8.0mg/l) in three sites and one site in Haman and Sacheon, respectively. The COD values of surface water exceeded water quality standard for agriculture(8.0mg/l) in Kimhae, Changnyong and Haman. The ${NH_4}^+-N$ values in surface water of Changnyong and Haman areas were 1.21mg/l and 2.75mg/l, respectively. The average values of $NO_3\;^--N$ in surface water was appropriate for agriculture. The values of $K^+,\;Na^+,\;Mg^{2+},\;Ca^{2+},\;{PO_4}^{3-}$ and $SO_4^{2-}$ in Haman were the highest of those of the others. And Pb was below 0.1mg/l which was water quality standard for agriculture. The average values of Cu, Cd and Zn were below water quality standard for agriculture. Between COD and SS in surface water was positively correlated with r$=0.799^{{\ast}{\ast}}$. BOD in surface water was positively correlated with $NH_4\;^+-N,\;PO_4\;^{3-},\;SS,\;K^+,\;Na^+$ and $Cl^-$. Surface water pollution status of agricultural water source of greenhouse areas in Gyeongnam was in order of Chinju< Sacheon< Kimhae< Changnyong< Haman area.

  • PDF

Analysis of Fish Compositions and Ecological Indicator Characteristic in Masan Reservoir. (마산저수지의 어류 종조성 및 생태 지표 특성 분석)

  • Han, Jung-Ho;Lee, Eui-Haeng;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.42 no.2
    • /
    • pp.212-220
    • /
    • 2009
  • In this study, we analyzed fish compositions and ecological characteristics such as trophic guilds and tolerance guilds in association with water quality characteristics in Masan Reservoir during November 2008. Total number of species were 12 species (6 families) and the dominant species were Zacco platypus, Hemiculter eigenmanni, and Pseudorasbora parva. We found three Korean endemic species and one exotic species, Carassius cuvieri. According to the analysis of ecological indicator characteristics, relative proportion of tolerant and omnivore species was 98% of the total indicating that probably, the fauna was influenced by physical habitat disturbance and physicochemical degradations. Fish distribution analysis along with littoral zone showed that the most fishes (${\sim}$95%) were observed in the littoral zone where emerged macrophytes were well developed. Also, substrate analysis indicated that the most species were found near silt area (11 species, 91.7%), so that the significant differences were found between the substrate types. Analysis of water quality indicated that concentrations of total phosphorus (TP) and chlorophyll-a (ChI-a) as a lake trophic indicator were judged as eutrophic states, respectively and COD as an indicator of organic matter pollution averaged 10.9 mg $L^{-1}$. Based on the water quality, this system were influenced by the nutrient enrichments and organic matter. The degradations of water quality in Masan Reservoir resulted in trophic compositions of fish (increase of omnivore species) and the dominance of tolerant fish. This Monitoring data may contribute changes of fish fauna and compositions in relation to habitat modifications and chemical water quality degradations in the future.

Comparison of Biomass by Forest Fire Type and Recovery at Samcheuk-si, Gangwon-do, Korea (산불 유형별 식생회복정도에 따른 현존생물량 비교)

  • Lim, Seok-Hwa;Kim, Jung-Sup;Shin, Jin-Ho;Bang, Je-Yong;Yang, Keum-Chul
    • Korean Journal of Environment and Ecology
    • /
    • v.26 no.4
    • /
    • pp.528-536
    • /
    • 2012
  • This study has compared the different types of forest fires(unburned, crown fire, ground fire) and the degree of vegetation recovery at Samcheuk-si, Gangwon-do by assessing the biomass and net primary production from July 2007 through July 2010. The research showed that the average biomass of unburned site(Un), crown fire site(C-1), crown fire site(C-3), ground fire site(G-2) were $181.20{\pm}5.39$, $62.04{\pm}4.38$, $131.09{\pm}14.38$, $63.39{\pm}2.72ton{\cdot}ha^{-1}$, respectively. And the research showed that the average net primary production of unburned site(Un), crown fire site(C-1), crown fire site(C-3), ground fire site(G-2) were $4.17{\pm}0.56$, $3.27{\pm}1.56$, $11.51{\pm}0.53$, $2.10{\pm}0.31ton{\cdot}ha^{-1}{\cdot}yr^{-1}$, respectively. Quercus mongolica $DH_{10}$(Diameter at the 10cm tree height) growth rate at each plot was compared to the crown fire site(C-1) in the annual average $1.21{\pm}0.55mm{\cdot}yr^{-1}$ at the speed of the fastest growth follows; showed crown fire site(C-3), ground fire site(G-2), unburned site(Un) appeared in the order. And that showed the growth rate of height was highest in the $15.43{\pm}4.57cm{\cdot}yr^{-1}$ at crown fire site(C-3), then the crown fire site(C-1), and ground fire site(G-2), and lowest in the unburned site(Un).

Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS (HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석)

  • Kim, Tae-Seung;Hong, Suk-Young;Kim, Jong-Eun;Lim, Hyun-Hee;Shin, Ho-Sang
    • Analytical Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 2012
  • A method to detect 37 volatile organic compounds (VOCs) in surface water was described based on headspace solid-phase micro extraction and gas chromatography-mass spectrometry. VOCs in water were vaporized for 30 min at 40 $^{\circ}C$ in a headspace vial and adsorbed on 85 ${\mu}m$ carboxen-polydimethylsiloxane. Under the established condition, the lowest quantification limit was 4.1-96 ng/L by using 4.0 mL water sample, and the relative standard deviation was less than 15% at concentrations of 0.05 and 0.50 ${\mu}g/L$. The detection limits meet lower concentration than 1/10 of the water quality criteria for VOCs established by the US EPA or Germany. The LOQ is a sensitivity which the monitoring for the establishing water quality criteria requires. When the proposed method was used to analyze the target compounds in sixteen surface water samples and total 16 VOCs were detected in surface water samples collected from Gum-River. Maximum concentrations of VOCs detected were not exceeded the EPA or Germany guidelines in any of the samples.

The Role of Tumor Necrosis Factor-$\alpha$ and Interleukin-$1{\beta}$ as Predictable Markers for Development of Adult Respiratory Distress Syndrome in Septic Syndrome (패혈증 증후군환자에서 성인성 호흡곤란 증후군 발생의 예측 지표서의 혈중 Tumor Necrosis Factor-$\alpha$와 Interleukin-$1{\beta}$에 관한 연구)

  • Koh, Youn-Suck;Jang, Yun-Hae;Kim, Woo-Sung;Lee, Jae-Dam;Oh, Soon-Hwan;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.5
    • /
    • pp.452-461
    • /
    • 1994
  • Background: Tumor necrosis factor(TNF)-$\alpha$ and Interleukin(lL)-$1{\beta}$ are thought to play a major role in the pathogenesis of the septic syndrome, which is frequently associated with adult respiratory distress syndrome(ARDS). In spite of many reports for the role of TNF-$\alpha$ in the pathogenesis of ARDS, including human studies, it has been reported that TNF-$\alpha$ is not sensitive and specific marker for impending ARDS. But there is a possibility that the results were affected by the diversity of pathogenetic mechanisms leading to the ARDS because of various underlying disorders of the study group in the previous reports. The purpose of the present study was to evaluate the roles of TNF-$\alpha$ and IL-$1{\beta}$ as a predictable marker for development of ARDS in the patients with septic syndrome, in which the pathogenesis is believed to be mainly cytokine-mediated. Methods: Thirty-six patients of the septic syndrome hospitalized in the intensive care units of the Asan Medical Center were studied. Sixteens suffered from ARDS, whereas the remaining 20 were at the risk of developing ARDS(acute hypoxemic respiratory failure, AHRF). In all patients venous blood samples were collected in heparin-coated tubes at the time of enrollment, at 24 and 72 h thereafter. TNF-$\alpha$ and IL-$1{\beta}$ was measured by an enzyme-linked immunosorbent assay (ELISA). All data are expressed as median with interquartile range. Results: 1) Plama TNF-$\alpha$ levels: Plasma TNF-$\beta$ levels were less than 10pg/mL, which is lowest detection value of the kit used in this study within the range of the $mean{\pm}2SD$, in all of the normal controls, 8 of 16 subjects of ARDS and in 8 in 20 subjects of AHRF. Plasma TNF-$\alpha$ levels from patients with ARDS were 10.26pg/mL(median; <10-16.99pg/mL, interquartile range) and not different from those of patients at AHRF(10.82, <10-20.38pg/mL). There was also no significant difference between pre-ARDS(<10, <10-15.32pg/mL) and ARDS(<10, <10-10.22pg/mL). TNF-$\alpha$ levels were significantly greater in the patients with shock than the patients without shock(12.53pg/mL vs. <10pg/mL) (p<0.01). There was no statistical significance between survivors(<10, <10-12.92pg/mL) and nonsurvivors(11.80, <10-20.8pg/mL) (P=0.28) in the plasma TNF-$\alpha$ levels. 2) Plasma IL-$1{\beta}$ levels: Plasma IL-$1{\beta}$ levels were less than 0.3ng/mL, which is the lowest detection value of the kit used in this study, in one of each patients group. There was no significant difference in IL-$1{\beta}$ levels of the ARDS(2.22, 1.37-8.01ng/mL) and of the AHRF(2.13, 0.83-5.29ng/mL). There was also no significant difference between pre-ARDS(2.53, <0.3-8.34ngfmL) and ARDS(5.35, 0.66-11.51ng/mL), and between patients with septic shock and patients without shock (2.51, 1.28-8.34 vs 1.46, 0.15-2.13ng/mL). Plasma IL-$1{\beta}$ levels were significantly different between survivors(1.37, 0.4-2.36ng/mL) and nonsurvivors(2.84, 1.46-8.34ng/mL). Conclusion: Plasma TNF-$\alpha$ and IL-$1{\beta}$ level are not a predictable marker for development of ARDS. But TNF-$\alpha$ is a marker for shock in septic syndrome. These result could not exclude a possibility of pathophysiologic roles of TNF-$\alpha$ and IL-$1{\beta}$ in acute lung injury because these cytokine could be locally produced and exert its effects within the lungs.

  • PDF

Blood Eosinophil and Serum Eosinophil Cationic Protein as a Marker of Bronchial Hyperresponsiveness in Children with Suspected Asthma (천식 증상 환아에서 기관지과민성의 지표로서 혈액 내 호산구와 혈청 호산구 양이온 단백(ECP))

  • Park, Yang;Kang, Hee;Kang, Eun Kyeong;Koh, Young Yull
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1577-1584
    • /
    • 2002
  • Purpose : Airway inflammation is considered to be a characteristic feature of asthma, and eosinophils are recognized as the most important inflammatory cells. This study aims to assess the importance of blood eosinophil count and serum eosinophil cationic protein(ECP) levels as a noninvasive marker of bronchial hyperresponsiveness(BHR) in children with suspected asthma. Methods : This study used data from 87 subjects with asthma-like symptoms(6-18 years old). The $FEV_1$ and provocative concentration producing a 20% fall in $FEV_1(PC_{20})$ on methacholin inhalation challenge test were measured. Four groups were classified based on $PC_{20}$[Group I : <2 mg/mL; Group II : 2-8 mg/mL; Group III : 8-18 mg/mL; Group IV : (18 mg/mL], and blood eosinophil count and serum ECP levels were analyzed. In addition, subjects were classified based on the cutoff value of $PC_{20}$(BHR positive group : <18 mg/mL; BHR negative group : (18 mg/mL). Then blood eosinophil count and serum ECP level were compared between these two groups. Results : Likelihood ratio test for trends revealed a significant association between the blood eosinophil count or serum ECP level, and the degree of BHR as measured by methacholine $PC_{20}$. Blood eosinophil count or serum ECP level was significantly higher in the BHR(+) group than in the BHR(-) group. Blood eosinophil count had a positive correlation with serum ECP level. Conclusion : Blood eosinophil count and serum ECP level may be a useful non-invasive clinical marker of BHR in subjects with suspected asthma. This supports the hypothesis that BHR in asthma is a consequence of airway eosinophilic inflammation.