• 제목/요약/키워드: L Resonator

검색결과 82건 처리시간 0.027초

Analysis of non-uniformly perforated muffler in concentric resonator type

  • Delaigue Antoine;Ih Jeong-Guon;Guyader Jean L.
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2001년도 추계학술발표대회 논문집 제20권 2호
    • /
    • pp.379-382
    • /
    • 2001
  • In the muffler industry, the main purpose of the research works is to determine a way to increase the TL (Transmission Loss) properties of the muffler, without deteriorating the back pressure influence. In order to obtain better results, several works have been done by changing the geometrical characteristics of the muffler or the type of the muffler. This work will focus on the perforated muffler components with concentric chamber, to investigate the effect of a non-uniform porosity along the inner perforated tube of the muffler on the TL. It is noted that varying the perforation ratio affects the peaks frequencies of the TL, especially fer $2\pi < kL < 4\pi$ (in the case of L : 200mm for the concentric resonator). The magnitudes of the TL, for this range of frequencies, vary noticeably by changing the porosity distribution.

  • PDF

High-Q $Yba_2Cu_3O_{7-\delta}$ 고온초전도체 공진기를 이용한 주파수 튜닝이 가능한 고성능 발진기 제작 (Fabrication of a High-performance Oscillator with a Tunable High-Q HTS $YBa_2Cu_3O_{7-\delta}$ Resonator)

  • 양우일;이재훈;허정;이상영
    • 대한전자공학회논문지TC
    • /
    • 제42권7호
    • /
    • pp.63-70
    • /
    • 2005
  • 위상잡음(phase noise)이 작은 발진기(oscillator)는 주파수 대역의 효율적 활용과 고속의 데이터 전송을 가능하게 하는 통신 시스템의 구축과 Doppler 효과를 이용하는 RADAR의 제작을 위한 핵심소자로서 발진기의 위상잡음은 공진부의 loaded Q($Q_{L}$)값이 클수록 작아진다. 본 논문에서는 고온초전도 $YBa_2Cu_3O_{7-\delta}$(YBCO) 박막을 사용하여 $TE_{011}$ 모드 고온초전도 YBCO-루타일 공진기를 제작하고 이 공진기가 공진단으로 사용된 발진기 특성의 시뮬레이션, 발진기 제작 및 위상잡음 측정 연구를 수행하였다. 23.5 K 및 $TE_{01\delta}$ 모드 공진주파수인 8.545 GHz에서 $Q_{L}$=180000 인 고온초전도 YBCO-루타일 공진기를 사용하여 제작된 발진기의 위상잡음은 1 KHz offset에서 -104.8 dBc/Hz 정도의 매우 작은 값을 지님을 확인하였다. Piezoactuator를 이용한 상온에서의 발진기 주파수의 튜닝 결과를 제시하고, 이러한 공진기가 사용된, 튜닝 가능한 고성능 발진기의 제작 가능성에 대해 논의하였다.

Nanoelectyomechanical Resonator Design and Performance Analysis

  • T. J. Kouh;Kim, D. H.;K. L. Ekinci
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2004년도 춘계학술대회 논문집
    • /
    • pp.538-541
    • /
    • 2004
  • We describe a method for the detection of nanometer scale displacements of nanoelectromechanical resonators. We also present an analysis of the mechanical motion of these devices. We evaluate the effectiveness of the detection technique by detecting displacements from a series of nanomechanical doubly clamped beam resonators with decreasing dimensions.

  • PDF

고주파 레조네이터용 변성 $PvTiO_3$계 세라믹스의 공진특성 (Resonant Properties of Modified $PvTiO_3$System Ceramics for High frequency Resonator)

  • 민석규;류주현;박창엽;김종선;윤현상;정회승
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.976-980
    • /
    • 2001
  • In this study, P $b_{0.88}$(L $a_{a}$N $d_{l-a}$)$_{0.08}$(M $n_{1}$3/S $b_{2}$3/)$_{0.02}$ $Ti_{0.98}$ $O_3$system ceramics were manufactured for 20 MHz class resonator application. Electromechanical coupling factor, mechanical quality factor and dynamic range of 3rd overtone thickness vibration mode were measured as the variations of La and Nd molar ratio. Mechanical quality factor and dynamic range at $\alpha$=0.6 composition ceramics showed the highest value of 2, 691 and 52.37 dB, respectively. The tempearture coefficient of resonant frequency measured from -2$0^{\circ}C$ to 8$0^{\circ}C$ showed an excellent value of 5ppm/$^{\circ}C$ at $\alpha$ = 1 composition ceramics. ceramics.s.

  • PDF

준 마이크로파 발진기를 이용한 비 침습 혈당 센서 (Non-Invasive Blood Glucose Sensor By Sub-Microwave Oscillator)

  • 윤기호
    • 한국융합학회논문지
    • /
    • 제8권9호
    • /
    • pp.9-16
    • /
    • 2017
  • 본 연구는 비 침습 방식으로 인체 혈당변화를 감지하여 준 마이크로파 대역의 발진 주파수 변화로 나타내는 발진기 센서를 제안하였다. 마이크로스트립 선로의 접지 면에 형성된 유도성 슬롯(inductive slot)과 생체조직 사이에 전자기적 결합을 통해 공진기로 구현되었으며, 능동회로를 연결하여 발진기를 구현하였다. 생체 조직을 가상한 팬텀 박스를 이용하였고, 3단계(0, 400, 800 mg/dL)의 혈당 농도 수준을 변화시켰을 때 공진기의 공진주파수가 상향 이동하는 것을 시뮬레이션 하였다. 시제품을 제작하여 인체 대신 돼지의 생체를 이용하여 실험한 결과, 1,100 MHz 부근에서 400 mg/dL의 혈당 농도변화 대비 약 14 MHz의 발진 주파수 천이가 관찰되어 혈당 센서에 적용할 수 있음을 확인하였다.

음향에너지를 이용한 내부 혼합형 이유체 분사노즐의 분무특성 (Spray Characteristics of Internal-Mixing Twin-Fluid Atomizer using Sonic Energy)

  • 조형건;강원수;석지권;이근선;이충원
    • 한국분무공학회지
    • /
    • 제4권3호
    • /
    • pp.32-41
    • /
    • 1999
  • In this research, internal-mixing twin-fluid atomizer using sonic energy is designed and manufactured. We are trying to intimate high efficiency twin-fluid atomizer to obtain good liquid atomization in the low pressure region. Define of geometric form of atomizer, characteristics of spray is influenced by position, depth and height variation of cavity resonator, variation of sound intensity and resonant sound frequency with liquid flow rate. The liquid atomization is promoted by multi-stage disintegration of mixing flow of gas with liquid and the optimum condition of position and depth of cavity resonator according to sonic energy is obtained from the condition at a=2.5mm and L=2mm. The velocity distribution of droplets shows negative value due to recirculation region at the center of axial, and as the radial direction distance is far, the velocity distribution of droplets decrease slowly after having a maximum value. However velocity and SMD show nearly uniform distribution at the down stream and as result compared to Nukiyama and Tanasawa's equation. atomization of mixing flow with air and liquid dispersing from the outlet of the nozzle is promoted by the effect of collision at the cavity resonator.

  • PDF

Re-enterant 공동 공진기의 주파수 가변 특성에 관한 실험적 고찰 (An Experimental Study on the Tuning Characteristics of a Re-enterant cavity resonator)

  • 김진구;홍의석
    • 한국통신학회논문지
    • /
    • 제12권2호
    • /
    • pp.133-138
    • /
    • 1987
  • 본 논문에서는 Re-enterant 공동 공진기의 내부 도체봉 길이 변화에 따른 공진 주파수의 가변특성을 실험정그로 고찰하였다. 실험시 제작된 공진기는 동축 케이블과 원형 도파관을 경합한 형태로서 동축 케이블의 내부 도체봉의 길이를 축방향으로 면화시킬 수 있도록 하여, 내부 도체봉의 임의의 길이에 대한 Tmonq 모드의 공진 주파수를 측정하였다. 경과의 타당성을 입증하기 위해서 실험 경과와 여러 사람들의 이론치를 비교하였다. 본 실험의 결과는 파장계, 공진기?l 증폭기의 공진 회로의 설계및 제작에 활용할 수 있으며 마이크로 웨이브 집적회로(MIC, Microwave Integrated Circuits)나 여과기에 사용되는 유전체 공진기의 공진 주파수를 가변시키는데도 사용할 수 있다.

  • PDF

고유함수 전개법을 이용한 비대칭 유전체 원주공진기의 공진특성 해석 (The Analysis of Resonance Characteristics of Asymmetric Dielectric Rod Resonator by Using Eigenfunction Expansion Method)

  • 민경호;류원열;최현철
    • 센서학회지
    • /
    • 제8권5호
    • /
    • pp.407-413
    • /
    • 1999
  • 유전체 원주 공진기의 공진주파수는 대칭성을 이용한 전기벽과 자기벽 개념을 도입해서 매우 정확하게 계산할 수 있으나, 유전체 공진기를 지지하기 위한 지지대의 존재 및 지지대의 유전율 등의 영향으로 인하여 유전체 원주 공진기의 구성이 실제로는 비대칭성을 가지므로, 비대칭 유전체공진기의 공진특성을 조사할 필요가 있다. 본 논문에서는 고유함수 전개법을 이용하여 도체 공동 내에 비대칭적으로 위치한 유전체 원주 공진기의 공진특성을 추출하는 관계식을 유도하고 공진주파수를 계산하였다. 실험을 통하여 계산된 공진주파수가 정확함을 확인하였고, 비대칭성이 있는 경우 TE 모드나 하이브리드 모드의 경우보다 TM 모드에 있어서 그 영향이 더 큼을 알 수 있었다.

  • PDF

수직형 폴리머 마이크로링 공진기 기반의 글루코스 바이오 센서 (Refractometric Glucose Biosensor Incorporating a Vertically Coupled Microring Resonator in Polymeric Waveguides)

  • 김건덕;손근식;이학순;김기도;이상신
    • 한국광학회지
    • /
    • 제19권2호
    • /
    • pp.127-131
    • /
    • 2008
  • 본 논문에서는 굴절률 감지 방식의 수직 결합형 폴리머 마이크로링 공진기 기반 글루코스 바이오 센서를 제안하고 구현하였다. 이 센서에서 상부 클래딩 역할을 하는 글루코스 분석 대상물의 농도 변화는 링 공진기의 공진파장 이동을 측정함으로써 얻어진다. 특히, 센서의 감도를 향상시키기 위해 다음과 같은 방법을 사용하였다. 첫째로, 분석 대상물에 근접한 유효굴절률을 갖는 폴리머 도파로 구조를 공진기 센서에 도입하였다. 둘째로, 분석 물질의 접촉면적을 확대하기 위해 측면 클래딩층이 충분히 식각된 pedestal 링 도파로 구조를 사용하였다. 제안된 공진기 센서는 빔전파 방법을 사용하여 설계하고 분석하였다. 사용된 코어 및 클래딩용 폴리머의 굴절률은 각각 1.430과 1.375였으며, 링 반경은 $400\;{\mu}m$였다. 이 때 얻어진 도파로의 유효굴절률은 ${\sim}1.390$였으며 글루코스 수용액의 굴절률 1.333와 매우 근접하였다. 제작된 소자의 기본적인 전달특성은 FSR(free spectral range) 0.66 nm, 대역폭 ${\sim}0.15\;nm$, Q 값 10,000 이었다. 1550 nm 광파장 대역에서 얻어진 측정 결과를 살펴보면, 센서 감도는 ${\sim}0.28\;pm$/(mg/dL)였으며, 이에 따른 굴절률 변화 감도는 ${\sim}200\;nm/RIU$였다.

900MHz ZigBee System 응용 분포소자형 Band Pass Filter 설계 (Design of Distributed Band Pass Filter for 900MHz ZigBee System applications)

  • 이중근;유찬세;김동수;원광호;이우성
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.163-166
    • /
    • 2005
  • Multilayer LTCC technology enables RF modules to be reduced dramatically by taking advantage of the three dimension flexibility. Compared to a conventional two dimensional PCB, LTCC allows higher density, reduced size, and lower cost. In this research, BPF based on LTCC for 900MHz ZigBee application was implemented which can replace SAW filter with using the material of the Dupont9599's dielectric constant 7.8. And distributed baud pass filter for 900MHz ZigBee system applications is presented. Using resonator stripline and capacitance, 2nd order band pass filter was designed. Adjusting resonator's length and capacitance is easy to tune at accurate center frequency by shifting band because ZigBee system is using narrow bandwidth, $902MHz^{\sim}928MHz$. Also resonator has no limitation in space, so reducing size is possibile. Designed filter had I.L. 2.8dB at 915MHz and attenuation at 815MHz, 1015MHz was 16dB, 15dB, respectively. Therefore, the sharpe cut-off and good insertion loss for ZigBee system application.

  • PDF