• 제목/요약/키워드: Korean tooth models

검색결과 246건 처리시간 0.024초

발치 및 비발치 치료증례에서의 치료전후 치열궁형태의 변화에 관한 연구 (A STUDY OF THE VARIANCES IN PRE- AND POST-TREATMENT DENTAL ARCH SHAPES IN EXTRACTION AND NON-EXTRACTION CASES)

  • 한홍;차경석
    • 대한치과교정학회지
    • /
    • 제21권1호
    • /
    • pp.223-238
    • /
    • 1991
  • This study was carried out in order to findout the amount of tooth movement, the changes arch size and the changes in arch morphology following orthodontic treatment and to provide a guideline for to predict post-treatment arch morphology. The sample group for this study consists of 15 males and 22 females, totalling in 37 persons, who received orthodontic treatment at Orthodontic Department of Dankook Univ. Dental Hospital. They are classified into Extraction Class I treatment group (E I), Non-extraction Class I treatment group (N I), and Non-extraction Class III treatment group (N III), according to their pre-treatment malocclusion state and methods of treatment. Following conclusions and averaged dental arch form for each group were obtained by cephalometric linear measurements and dental arch measurements using pre- and post-treatment lateral cephalograms and plaster study models. 1. Intercanine width were reduced in max. of both EI and NI during the period of treatment, 2. Intermolar width were reduced in max. of EI and increased in max. of NI. Therefore although there was no difference between these two groups before the treatment, intermolar width of the max, of NI was wider than that of E1 after the treatment. 3. PMV-incisor distance and PMV-canine distance were decreased in both max. and mand. of EI and that of NI, during the period of treatment. PMV-molar distance was decreased in both max. and mand. of NI and in mand. of NIII. 4. Items that showed stability during the treatment were: max. & mand. PMV-molar distance, mand. intercanine and intermolar width in EI; mand. intercanine and intermolar width in NI; mand. & max. PMV-incisor distance, PMV-canine distance, max. PMV-molar distance and max. & mand. intercanine and intermolar width in NIII. 5. The differences in averaged canine and molar variances to post-treatment dental arch form were present only in EI and in NI. There was no variance between maxilla and mandible in each group.

  • PDF

Effect of bite force on orthodontic mini-implants in the molar region: Finite element analysis

  • Lee, Hyeon-Jung;Lee, Kyung-Sook;Kim, Min-Ji;Chun, Youn-Sic
    • 대한치과교정학회지
    • /
    • 제43권5호
    • /
    • pp.218-224
    • /
    • 2013
  • Objective: To examine the effect of bite force on the displacement and stress distribution of orthodontic mini-implants (OMIs) in the molar region according to placement site, insertion angle, and loading direction. Methods: Five finite element models were created using micro-computed tomography (microCT) images of the maxilla and mandible. OMIs were placed at one maxillary and two mandibular positions: between the maxillary second premolar and first molar, between the mandibular second premolar and first molar, and between the mandibular first and second molars. The OMIs were inserted at angles of $45^{\circ}$ and $90^{\circ}$ to the buccal surface of the cortical bone. A bite force of 25 kg was applied to the 10 occlusal contact points of the second premolar, first molar, and second molar. The loading directions were $0^{\circ}$, $5^{\circ}$, and $10^{\circ}$ to the long axis of the tooth. Results: With regard to placement site, the displacement and stress were greatest for the OMI placed between the mandibular first molar and second molar, and smallest for the OMI placed between the maxillary second premolar and first molar. In the mandibular molar region, the angled OMI showed slightly less displacement than the OMI placed at $90^{\circ}$. The maximum Von Mises stress increased with the inclination of the loading direction. Conclusions: These results suggest that placement of OMIs between the second premolar and first molar at $45^{\circ}$ to the cortical bone reduces the effect of bite force on OMIs.

Three-dimensional analysis of the distal movement of maxillary 1st molars in patients fitted with mini-implant-aided trans-palatal arches

  • Miresmaeili, Amirfarhang;Sajedi, Ahmad;Moghimbeigi, Abbas;Farhadian, Nasrin
    • 대한치과교정학회지
    • /
    • 제45권5호
    • /
    • pp.236-244
    • /
    • 2015
  • Objective: The aim of this study was to investigate three-dimensional molar displacement after distalization via miniscrews and a horizontal modification of the trans-palatal-arch (TPA). Methods: The subjects in this clinical trial were 26 Class II patients. After the preparation of a complete set of diagnostic records, miniscrews were inserted between the maxillary 2nd premolar and 1st molar on the palatal side. Elastic modules connected to the TPA exerting an average force of 150-200 g/side parallel to the occlusal plane were applied. Cone-beam computed tomography was utilized to evaluate the position of the miniscrews relative to the adjacent teeth and maxillary sinus, and the direction of force relative to molar furcation. The distances from the central point of the incisive papilla to the mesiopalatal cusps of the 1st maxillary molars and the distances between the mesiopalatal cusps of the left and right molars were measured to evaluate displacement of the maxillary molars on the horizontal plane. Interocclusal space was used to evaluate vertical changes. Results: Mean maxillary 1st molar distalization was $2.3{\pm}1.1mm$, at a rate of $0.4{\pm}0.2mm/month$, and rotation was not significant. Intermolar width increased by $2.9{\pm}1.8mm$. Molars were intruded relative to the neighboring teeth, from 0.1 to 0.8 mm. Conclusions: Distalization of molars was possible without extrusion, using the appliance investigated. The intrusive component of force reduced the rate of distal movement.

Unilateral maxillary central incisor root resorption after orthodontic treatment for Angle Class II, division 1 malocclusion with significant maxillary midline deviation: A possible correlation with root proximity to the incisive canal

  • Imamura, Toshihiro;Uesugi, Shunsuke;Ono, Takashi
    • 대한치과교정학회지
    • /
    • 제50권3호
    • /
    • pp.216-226
    • /
    • 2020
  • Root resorption can be caused by several factors, including contact with the cortical bone. Here we report a case involving a 21-year-old female with Angle Class II, division 1 malocclusion who exhibited significant root resorption in the maxillary right central incisor after orthodontic treatment. The patient presented with significant left-sided deviation of the maxillary incisors due to lingual dislocation of the left lateral incisor and a Class II molar relationship. Cephalometric analysis demonstrated a Class I skeletal relationship (A point-nasion-B point, 2.5°) and proclined maxillary anterior teeth (upper incisor to sella-nasion plane angle, 113.4°). The primary treatment objectives were the achievement of stable occlusion with midline agreement between the maxillary and mandibular dentitions and appropriate maxillary anterior tooth axes and molar relationship. A panoramic radiograph obtained after active treatment showed significant root resorption in the maxillary right central incisor; therefore, we performed cone-beam computed tomography, which confirmed root resorption along the cortical bone around the incisive canal. The findings from this case, where different degrees of root resorption were observed despite comparable degrees of orthodontic movement in the bilateral maxillary central incisors, suggest that the incisive canal could be an inducing factor for root resorption. However, further investigation is necessary to confirm this assumption.

와동내에 조사된 열의 전도양상에 관한 연구 (A STUDY FOR THERMAL CONDUCTIVITY OF IRRADIATED CAVITY)

  • 백병주;김재곤;허선;이두철;윤현두
    • 대한소아치과학회지
    • /
    • 제25권3호
    • /
    • pp.583-597
    • /
    • 1998
  • The purpose of this study was to evaluate temperature change occurred in enamel, dentin and pulp due to the heat from cavity prepration with laser. We made three models had different cavity depth: cavity depth of model A was 3.52mm, model B was 2.32mm, model C was 1.16mm. We irradiated cavity base with thermal capacity of $30J,100J,300J/cm^2s$ during few seconds and studied the change of temperature in tooth during 10 seconds, and estimated change of thermal capacity by different irradiated site and exposure time. At $300J/cm^2$ irradiation for 2 seconds, the temperature of irradiated surface was elevated fast according to irradiated thermal energy during 1 second. In proportion to continuous exposure time, temperature elevated slowly. The surface temperature was $1370^{\circ}C$. After discontinue of thermal irradiation, the heat of irradiated surface was diffused in dentin and pulp and the greatest temperature was made. The greatest temperature was disappeared within 10 seconds The greatest temperature of the inner part of model brought about very severe change by different depth. Temperature in pulp was raised by the greater irradiated energy density and exposure time.

  • PDF

이유보충식 도입 시기에 따른 유아기 우식증 관련성 연구: 2008~2015년도 국민건강영양조사 자료 이용 (Relationship between Complementary Feeding Introduction and Early Childhood Caries: Results from the Korea National Health and Nutrition Examination Survey 2008-2015)

  • 연미영;신혜선;이행신
    • 대한지역사회영양학회지
    • /
    • 제24권2호
    • /
    • pp.97-105
    • /
    • 2019
  • Objectives: This study examined whether the infant feeding type and duration are related to the introduction of complementary feeding, and whether the appropriate introduction of complementary feeding in infancy is related to tooth decay in toddlers. Methods: The subjects were 1,521 toddlers among 2~3 year old children in the Korea National Health and Nutrition Examination Survey from 2008 to 2015. The toddlers were divided into the appropriate group (4~6 months) and delayed group (>6 months) according to the timing of complementary feeding introduction. Results: The delayed group were 26.5% of subjects and the formula feeding period in the appropriate group and delayed group was 8.4 and 10.3 months, respectively (P=0.002). On the other hand, there was no difference in the breastfeeding period between the appropriate group and delayed group (P=0.6955). Early childhood caries was more common in the delayed group (P=0.0065). The delayed introduction of complementary feeding was associated with a risk of early childhood caries according to the logistic models (OR 1.81, 95% CI 1.27-2.57). Conclusions: The introduction of complementary feeding is associated with early childhood caries. Therefore, the importance of the proper introduction of complementary feeding in infancy should be emphasized, and public relations and education for maternal care and breastfeeding should be provided through health care institutions.

Clinical effects of different prescriptions on the inclination of maxillary and mandibular incisors by using passive self-ligating brackets

  • Savoldi, Fabio;Sangalli, Linda;Ghislanzoni, Luis T. Huanca;Dalessandri, Domenico;Gu, Min;Mandelli, Gualtiero;Paganelli, Corrado
    • 대한치과교정학회지
    • /
    • 제52권6호
    • /
    • pp.387-398
    • /
    • 2022
  • Objective: Controlling the incisal inclination is fundamental in orthodontics. However, the relationship between the inclination prescription and its clinical outcome is not obvious, and the incisal inclination changes generated by different bracket prescriptions were investigated. Methods: Twenty-eight non-extraction dental Class II patients (15 females, 13 males; mean age = 12.9) were retrospectively analyzed. Patients were treated using passive self-ligating fixed appliances with three inclination prescriptions for maxillary incisors (high, standard, low), and two for mandibular incisors (standard, low). Clinical outcomes were compared among different prescriptions, and regression analysis was used to explain the effects of bracket prescriptions and to understand the prescription selection criteria (α = 0.05). Results: For maxillary central incisors, low and high prescriptions were related to linguoversion (p = 0.046) and labioversion (p = 0.005), respectively, while standard prescription maintained the initial dental inclination. Maxillary lateral incisors did not show significant changes. For mandibular incisors, low prescription led to linguoversion (p = 0.005 for central incisors, p = 0.010 for lateral incisors), while standard prescription led to labioversion (p = 0.045 for central incisors, p = 0.005 for lateral incisors). The factors affecting inclination changes were the imposed change and selected prescription, while prescription selection was influenced by the initial dental inclination and initial intercanine distance. Conclusions: The direction of correction of incisal inclination can be controlled by choosing a certain prescription, but the final inclination may show limited consistency with it. The amount of imposed inclination change was the most relevant predictor of the clinical outcome.

Force Assessment of Thermoformed and Direct-printed Aligners in a Lingual Bodily Movement of a Central Incisor Over Time: A 14-day In Vitro Study

  • Mary Linda Remley;Gabriel Ferreira Pessoa Carvalho Miranda ;Brent Bankhead;Julie McCray;Ki Beom Kim
    • Journal of Korean Dental Science
    • /
    • 제16권1호
    • /
    • pp.23-34
    • /
    • 2023
  • Purpose: This study aims to investigate the force delivery profile of thermoformed aligners (TFA) compared with direct-printed aligners (DPA) and to explore the effect of different activation amounts on forces and moments of respective groups. A secondary objective is to observe the amount of stress relaxation that occurs over the 7~14 days when aligners are maintained in a simulated intraoral environment. Materials and Methods: An in vitro setup was created to quantify forces and moments. It consisted of a three dimensional-printed base plate and segmented maxillary teeth, placed in a semi-enclosed chamber to maintain a temperature of 37℃. Ninety clear aligners were divided into nine groups of ten aligners each based on material types (Zendura, ATMOS, TC-85) and activation amounts. Aligners were created with 0.00, 0.25- and 0.50-mm activations for lingual bodily movement of the upper left central incisor and kept on models in the "stressed" position in a 37℃ water bath. Three force components acting on the upper left lateral incisor, upper left central incisor, and upper right central incisor were measured for each time point, beginning from the initial baseline measurement, 8 hours, 16 hours, 24 hours, 2 days, 3 days, 4 days, 5 days, 6 days, 7 days, and lastly, 14 days. Result: TC-85 aligners in every activation group showed less force on teeth than Zendura and ATMOS. Significant force levels from 0.0 mm activation were present and stayed consistent over the course of 14 days. Comparisons made for baseline measurements to 7-days and 14-days showed statistically significant change from the baseline force level. Conclusion: TC-85 aligners demonstrated lower, more consistent forces with fewer side effects. Aligners can generate forces even when no activation is programmed. No major decreases in force levels over time were observed; the intra-oral clinical simulated environment and length of observation time could contribute to this.

Periodontal health status, oral microbiome, white-spot lesions and oral health related to quality of life-clear aligners versus fixed appliances: A systematic review, meta-analysis and meta-regression

  • Ana Sandra Llera-Romero;Milagros Adobes-Martin;Jose Enrique Iranzo-Cortes;Jose Maria Montiel-Company;Daniele Garcovich
    • 대한치과교정학회지
    • /
    • 제53권6호
    • /
    • pp.374-392
    • /
    • 2023
  • Objective: Assess and evaluate the different indicators of oral health-related quality of life (OHRQoL) among patients treated with clear aligners (CAs) versus those treated with conventional fixed orthodontics (FAs). Methods: An electronic search was performed on the database is Web of Science, Scopus, and Embase databases. Randomized and non-randomized control trials, cross-sectional, prospective cohort and retrospective trials were included. Quality was assessed with risk of bias tool and risk of bias in non-randomised studies. Meta-analyses were performed with random effects models, estimating the standardized and non-standardized mean differences, odds ratio and risk ratio as the measure of effect. The effect on time was determined using a meta-regression model. Results: Thirty one articles were included in the qualitative synthesis and 17 in the meta-analysis. CAs had a significantly lower negative impact on QoL, with an "important" effect size, while the influence of time was not significant. Periodontal indicators plaque index (PI), gingival index (GI), probing depth (PD), and bleeding on probing show significantly better values in patients treated with CAs, with moderate to large effect sizes. PI and GI have a significant tendency to improve over time. In microbiological indicators, CAs present a lower biofilm mass without differences in the percentage of patients with high counts of Streptococcus mutans and Lactobacilli bacteria. The risk of white spot lesion onset is ten times lower in carriers of CAs. Conclusions: Patients wearing CAs show better periodontal indicators, less risk of white spot development, less biofilm mass and a better QoL than patients with FAs.

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구 (The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials)

  • 최석순;김기백;이경탁;전진훈;김재홍
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.