• Title/Summary/Keyword: Korean tooth models

Search Result 246, Processing Time 0.029 seconds

A Study on Crack Fault Diagnosis of Wind Turbine Simulation System (풍력발전기 모사 시스템에서의 균열 결함 진단에 대한 연구)

  • Bae, Keun-Ho;Park, Jong-Won;Kim, Bong-Ki;Choi, Byung-Oh
    • Journal of Applied Reliability
    • /
    • v.14 no.4
    • /
    • pp.208-212
    • /
    • 2014
  • An experimental gear-box was set-up to simulate the real situation of the wind-turbine. Artificial cracks of different sizes were machined into the gear. Vibration signals were acquired to diagnose the different crack fault conditions. Time-domain features such as root mean square, variance, kurtosis, normalized 6th central moments were used to capture the characteristics of different crack conditions. Normal condition, 1 mm crack condition, 2mm crack condition, 6mm crack condition, and tooth fault condition were compared using ANFIS and DAG-SVM methods, and three different DAG-SVM models were compared. High-pass filtering improved the success rates remarkably in the case of DAG-SVM.

A Study on the Age Estimation by Attrition of the Adult Teeth (성인치아의 교모도를 이용한 연령추정에 관한 연구)

  • 안휘준;박준상;고명연
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.85-99
    • /
    • 1998
  • In order to estimate the tooth-age by degree of attrition, the author has studied 605 stone models from 1996 to 1997. All of the attrition were classified and analyzed by 8 degrees. The result were as follows : 1. The degree of attrition in male was higher than that in female for same age group and especially, canine and first premolar showed the most prominent difference in sex. 2. The most severe attrition in posterior teeth was first molar followed by second molar, first premolar and second premolar in decreasing order of sequence. 3. The coefficient of correlation and relation equations by the degree of attrition were obtained.

  • PDF

The Role of Immune Response in Periodontal Disease (치주질환의 면역학)

  • Kim, Kack-Kyun
    • IMMUNE NETWORK
    • /
    • v.3 no.4
    • /
    • pp.261-267
    • /
    • 2003
  • The periodontal diseases are infections caused by bacteria in oral biofilm, a gelatinous mat commonly called dental plaque, which is a complex microbial community that forms and adhere to tooth surfaces. Host immune-pathogen interaction in periodontal disease appears to be a complex process, which is regulated not only by the acquired immunity to deal with ever-growing and -invading microorganisms in periodontal pockets, but also by genetic and/or environmental factors. However, our understanding of the pathogenesis in human periodontal diseases is limited by the lack of specific and sensitive tools or models to study the complex microbial challenges and their interactions with the host's immune system. Recent advances in cellular and molecular biology research have demonstrated the importance of the acquired immune system in fighting the virulent periodontal pathogens and in protecting the host from developing further devastating conditions in periodontal infections. The use of genetic knockout and immunodeficient mouse strains has shown that the acquired immune response, in particular, $CD4^+$ T-cells plays a pivotal role in controlling the ongoing infection, the immune/inflammatory responses, and the subsequent host's tissue destruction.

Design and The Characteristic Analysis of the linear pulse motor for X-Y table (X-Y테이블 구동용 리니어 펄스모터의 설계와 특성해석)

  • Park, Chang-Soon;Kwon, Tae-Gun
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.182-184
    • /
    • 2001
  • Linear pulse Motor(LPM) are used a field where smooth linear motion is required, and it's position accuracy higher than that of a lead. According to the advantage such as simplicity of mechanical frame, high reliability, precise open_loop operation, low inertia etc LPM is applied largely where it have made motor of this kind more and more attractive in many application areas such as factory automation and high speed positioning. This paper is researched to analyze for thrust force characteristic of hybrid LPM. Both the thrust and normal force are very sensitive to the airgap and tooth pitches of the force and platen. To find the optimal design parameter on the hybrid LPM for the embroidery machine. For the field analysis, the finite element method(FEM) is employed for calculating the force. The reluctance models will be used the magnetic permeance of airgap under static-conditions. The forces between forcer and platen have been calculated using the virtual work mathod.

  • PDF

An Investigation on Vibration Characteristics of Vehicle Transmission (차량변속기의 진동특성에 대한 연구)

  • 배명호;이형우;박노길
    • Journal of KSNVE
    • /
    • v.10 no.1
    • /
    • pp.107-116
    • /
    • 2000
  • The gear whine noise caused by tooth profile, elastic deformation, machining error, wear is directly correlated with the transmission error of mating gear. It is very important to build up the synthesized countermeasure by the modeling of the excitation forces and analyzing the vibratory characteristics. The mathematical models on the elements of vehicle transmission which is composed of helical gears, bearings, shafts and cases are developed. The elements are assembled by the substructure synthesis method. The cases of transmission are modeled by ANSYS. The system model of vehicle transmission is also verified by the experiments.

  • PDF

Comparison of the accuracy of digital models made from white light scanner by scanning method (스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지털 모형의 정확성 비교)

  • Kim, Ki-Baek;Lee, Gyeong-Tak;Kim, Jae-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.12 no.6
    • /
    • pp.1082-1089
    • /
    • 2012
  • Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix$^{(R)}$, GC Industrial Corp, Japan) of master model were taken and type IV stone(aesthetic-base gold$^{(R)}$, Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Finite element analysis of maxillary incisor displacement during en-masse retraction according to orthodontic mini-implant position

  • Song, Jae-Won;Lim, Joong-Ki;Lee, Kee-Joon;Sung, Sang-Jin;Chun, Youn-Sic;Mo, Sung-Seo
    • The korean journal of orthodontics
    • /
    • v.46 no.4
    • /
    • pp.242-252
    • /
    • 2016
  • Objective: Orthodontic mini-implants (OMI) generate various horizontal and vertical force vectors and moments according to their insertion positions. This study aimed to help select ideal biomechanics during maxillary incisor retraction by varying the length in the anterior retraction hook (ARH) and OMI position. Methods: Two extraction models were constructed to analyze the three-dimentional finite element: a first premolar extraction model (Model 1, M1) and a residual 1-mm space post-extraction model (Model 2, M2). The OMI position was set at a height of 8 mm from the arch wire between the second maxillary premolar and the first molar (low OMI traction) or at a 12-mm height in the mesial second maxillary premolar (high OMI traction). Retraction force vectors of 200 g from the ARH (-1, +1, +3, and +6 mm) at low or high OMI traction were resolved into X-, Y-, and Z-axis components. Results: In M1 (low and high OMI traction) and M2 (low OMI traction), the maxillary incisor tip was extruded, but the apex was intruded, and the occlusal plane was rotated clockwise. Significant intrusion and counter-clockwise rotation in the occlusal plane were observed under high OMI traction and -1 mm ARH in M2. Conclusions: This study observed orthodontic tooth movement according to the OMI position and ARH height, and M2 under high OMI traction with short ARH showed retraction with maxillary incisor intrusion.

A COMPARATIVE ANALYSIS OF THE ACCURACY OF IMPLANT IMPRESSION TECHNIQUES BY USING STRAIN GAUGE (Strain gauge를 사용한 임플랜트 인상법의 정확도 비교)

  • Han, Eu-Taek;Kim, Yung-Soo;Kim, Chang-Whe
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.539-549
    • /
    • 1995
  • The purpose of this study was to determine the accuracy of 3 implant impression methods by using strain gauge. The models used for this study were partially edentulous mandibular acrylic resin casts Model A, with two abutment analogs in #46,47 extraction site, represented two implant parallel to to the adjacent natural tooth. Model B represent an anterior implant parallel to the adjacene natural tooth and a posterior implant exhibiting a 15-degree lingual inclination. Master framework were fabricated on the master model, and 3 strain gauges were attached to a master framwork to determine the passivity of fit of the framework to sample casts made by the three impression techniques. The master framework was attached to each sample cast with gold screws, which were tightened with the torque driver to ensure a consistent toque application of 10 Ncm. Universal Digital Measuring System UCAM-5BT was used for strain measuring. Impression techniques studid were : 1. unsplinted tapered impression coping, polyvinyl siloxane, stock tray 2. unsplinted squared impression coping, polyether, custom tray 3. squared impression coping splinted with Duralay resin, polyether, custom tray Through analysis on data from this study, the following conclusions were obtained. 1. There were no statistically significant differences between the mean strain recorded from the sample casts made with the tree impression. But only strain values of model A(parallel group) Y-axis was signifcantly differed between Technique 1 and 3(P<0.05). 2. There was no statistically significant difference between model A(parallel group) and model B(15-degree divergent group).

  • PDF

RETENTIVE FORCES OF CLASPS OF REMOVABLE ORTHODONTIC APPLIANCES FOR CHILDREN (어린이에게 사용되는 가철식 교정장치용 clasp의 유지력비교)

  • Han, Jeong-Jae;Lee, Kwang-Hee;Kim, Dae-Eop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.2
    • /
    • pp.207-217
    • /
    • 1999
  • The purpose of this study was to compare the retentive forces of various types of clasps for removable orthodontic appliances for primary and mixed dentition. Seven metal models of a single tooth and two teeth were made, including maxillary left primary canine, first primary molar, second primary molar and first molar. Retentive forces of Adams clasp, circumferential clasp(C clasp), Jackson clasp, Duyzing clasp, arrowhead clasp, ball clasp, eyelet clasp, and triangular clasp were measured by Universal Testing Machine(Zwick Z020, Germany). The obtained results were as follows. 1. Jackson clasp and Adams clasp showed the highest retentive force among single tooth clasps. 2. C clasp showed the lowest retentive force, and there was no statistically significant difference in retentive force between mesial end C clasp and distal end C clasp. 3. Eyelet clasp showed the highest, and ball clasp showed the lowest retentive farce among clasps for interdental undercut. 4. Triangular clasp showed higher retentive force than ball clasp.

  • PDF

THE EFFECTS OF CLEFT ON MESIODISTAL DIMENSIONS OF PERMANENT TEETH IN UNILATERAL CLEFT LIP AND PALATE PATIENTS (순구개열이 영구치 근원심 폭경에 미치는 영향)

  • Bok, Jae-Kweon;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 1995
  • The purpose of this study was to investigate the effects of cleft on mesiodistal dimensions of permanent teeth in unilateral cleft lip and palate patients. Mesiodistal dimensions of permanent teeth were measured to the nearest 0.01mm on plaster models of 50 subjects with unilateral complete cleft lip and palate, 10 siblings and 50 Controls. The results were as follows : 1. Tooth size discrepancy in the cleft group was significant in all regions except maxillary cuspid, mandibular cuspid and mandibular first premolar. 2. Some of the mesiodistal dimensions of the teeth on the cleft side were significantly smaller than those of their antimeres on the non-cleft side in the cleft group. 3. A comparison of mesiodistal dimensions of the teeth for the right and left sides of the control group showed no statisically significant differences excepts maxillary lateral incisor. 4. Asymmetries of mesiodistal dimensions of the teeth in the sibling group was not found except maxillary first molar.

  • PDF