• 제목/요약/키워드: Korean squid

검색결과 892건 처리시간 0.021초

단일층 $d^2B_{z}$/dxdy SQUID 2차 미분기 설계 및 제작 (Fabrication of sing1e layer $d^2B_{z}$/dxdy second-order SQUID gradiometer)

  • 황윤석;박승문;이순걸;김인선;박용기
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.109-113
    • /
    • 2003
  • We have developed a planar-type single layer second-order $high-T_{c}$ SQUID gradiometer, which can detect the $d^2$$B_{z/}$dxdy of the second-order field gradient. This SQUID gradiometer consists of four-way 'clover-leaf' pick-up loops and is coupled directly to a 4-junction dc SQUID in such a way that the coupling polarity of the two diagonal loops is opposite to that of the other two loops. The pickup loops are intrinsically balanced for both uniform field and the 1 st-order field gradient. The $YBa_2$$Cu_3$$O_{7}$ thin film was made by pulsed laser deposition method on $SrTiO_3$ single crystal substrate and patterned by photolithography with Ar ion milling technique. Response of this gradiometer was tested for both uniform field and the 2nd-order field gradient. Details of the design, fabrication, and results will be discussed.

  • PDF

저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작 (Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

비자기 차폐 환경에서의 SQUID를 이용한 비파괴 평가 시스템에 대한 연구 (Nondestructive Evaluation System using SQUID in Magnetically Un-shielded Environment)

  • 정순희;황윤석;최희석;김진태;임해용;김인선;권혁찬;박용기;박종철;이순걸;이동훈;김동호
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.54-57
    • /
    • 1999
  • 본 연구에서는 SQUID를 이용한 비파괴 평가 시스템을 제작, 측정하였다. 이 시스템은 비자기 차폐 환경에서 작동할 수 있도록 설계하였고, 측정 자기 센서로는 dc 및 rf-SQUID gradiometer를 사용하였다. 비자기 차폐 환경에서 ${\sim}$nT의 미세 자기 신호를 검출하였고, 공간적으로 변화하는 외부 자기 신호를 측정, 분석하였다. 또한, 측정된 자기 신호를 통해 dc-SQUID와 rf-SQUID에 대한 비교를 했다.

  • PDF

40-채널 SQUID 시스템의 제작 및 뇌자도 측정 (Construction and Operation of a 40-channel SQUID System for Neuromagnetic Measurements)

  • 이용호;김진목;권혁찬;이상길;임청무;박용기;박종철
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.27-32
    • /
    • 1999
  • We developed a 40-channel superconducting quantum interference device (SQUID) system for neuromagnetic measurements. The main features of the system are use of double relaxation oscillation SQUID (DROS), and planar gradiometer for measuring tangential field components. The DROSS with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature electronics and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. The average noise of the 40 channels is around 1.2 fT/cm/${\sqrt{Hz}}$ at 100 Hz, corresponding to the field noise of 5 fT/${\sqrt{Hz}}$ at 100 Hz, operated inside a magnetically shielded room. The 40-Channel system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계 (YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF

Construction of a 40-channel SQUID System and Its Application to Neuromagnetic Measurements

  • Lee, Y.H.;Kim, J.M.;Kwon, H.C.;Park, Y.K.;Park, J.C.;Lee, D.H.;Ahn, C.B.
    • Progress in Superconductivity
    • /
    • 제2권1호
    • /
    • pp.20-26
    • /
    • 2000
  • A 40-channel superconducting quantum interference device (SQUID) system was constructed for measuring neuromagnetic fields. Main features of the system are the use of double relaxation oscillation SQUIDs (DROSs), and planar gradiometers measuring magnetic field components tangential to the head surface. The DROSs with high flux-to-voltage transfers enabled direct readout of the SQUID output by room-temperature dc preamplifiers and simple flux-locked loop circuits could be used for SQUID operation. The pickup coil is an integrated first-order planar gradiometer with a baseline of 40 mm. Average noise level of the 40 channels is around 1.2 $fT/cm/{\surd}Hz$ at 100 Hz, corresponding to a field noise of 5 $fT/{\surd}Hz$, operated inside a magnetically shielded room. The SQUID insert was designed to have low thermal load, minimizing the loss of liquid helium. The constructed system was applied to measure auditory-evoked neuromagnetic fields.

  • PDF

Stability of Antioxidant Properties and Essential Amino Acids in Squid Viscera Hydrolysate Produced using Subcritical Water

  • Kim, Ryoung-Hee;Asaduzzaman, A.K.M.;You, Chi-Hong;Chun, Byung-Soo
    • Fisheries and Aquatic Sciences
    • /
    • 제16권2호
    • /
    • pp.71-78
    • /
    • 2013
  • Subcritical water hydrolysis was carried out in a batch reactor to produce valuable materials, such as low-molecular weight (MW) peptides and essential amino acids with antioxidant properties, from heat-dried squid viscera. Hydrolysis of squid viscera was performed at 160 to $280^{\circ}C$ for 3 min. The yield was increased by increasing the temperature and pressure, while the protein content of squid viscera hydrolysate decreased with increasing temperature. Low-MW peptides were detected in all hydrolysates by sodium dodecyl sulfate polyacrylamide gel electrophoresis. The highest yields of free and structural amino acids in heat-dried squid viscera hydrolysate were at $160^{\circ}C$ and were $411.95{\pm}1.15$ and $346.62{\pm}1.25$ mg/100 g, respectively. All essential amino acids were detected in viscera hydrolysates; leucine was the most abundant. Antioxidant activities of hydrolysates were highest at $220^{\circ}C$. Greater than $98{\pm}0.26%$ of the ABTS antioxidant activity was retained in hydrolysates after long-term heat treatment.

Nitrogen-14 NQR using High-Tc RF SQUID

  • He, D.F.;Tachiki, M.;Itozaki, H.
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2007년도 High Temperature Superconductivity Vol.XVII
    • /
    • pp.7-7
    • /
    • 2007
  • PDF