• Title/Summary/Keyword: Korean song

Search Result 46,923, Processing Time 0.077 seconds

Physiological Responses of Rhododendron mucronulatum and R. indicum with Shading Treatment in Autumn Season (가을철 차광 처리에 따른 진달래와 영산홍의 생리적 반응)

  • Lee, Kyung-Jae;Song, Ki-Sun;Chung, Young-Suk;Yoon, Taek-Seong;Hong, Sung-Kwon;Kim, Jae-Hyun;Lee, Sang-Woo;Kim, Jong-Jin
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.403-408
    • /
    • 2010
  • This study was carried out to investigate the physiological responses of $Rhododendron$ $mucronulatum$ Turcz. and $R.$ $indicum$ (L.) Sweet seedlings with 0%, 35%, 55% and 75% shading of full sunlight in polyethylene film house. The shading treatments were performed during the late growth season for each species (from Sept. 9 to Nov. 5, 2008). The shading treatment was effective in reducing the daily temperature by 0.9 to $1.7^{\circ}C$ during September and by 0.8 to $1.7^{\circ}C$ during October. Before the shading treatments, the water content of $R.$ $mucronulatum$ and $R.$ $indicum$ amounted to 68.5% and 66.3%, respectively. The water contents of two species after 75% shading treatment period decreased to 66.2% (3.4% reduction) and 65.9% (0.6% reduction), respectively. Notably, both species had a similar tendency indicating less reduction rate of water content with 75% shading. $R.$ $indicum$ showed higher photosynthetic capacity with higher level of shading, and its photosynthetic capacity reached the highest level ($9.63{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$). On the other hand, shading-treated $R.$ $indicum$ showed higher intercellular $CO_2$ concentration, stomatal conductance and transpiration rate (55% shading > 35% shading > 75% shading) than non-treated ones. In addition, non-treated seedlings showed higher water use efficiency than treated ones. In particular, it was found that the leaf color of $R.$ $mucronulatum$ turned equivalent to purple under full sunlight, while its leaf color kept equivalent more to green with higher level of shading, as evidenced even in naked eyes. According to comprehensive analysis using Munsell Color Chart on potential leaf color variations of $R.$ $mucronulatum$ depending on the level of shading, it was found that relatively many leaf colors under full sunlight were equivalent to R (red) and Y (yellow) chart, while relatively many leaf colors with higher level of shading were equivalent to G (green) and Y chart, where the latter still showed green color.

Evaluation of Early Productivity of High Density 'Fuji' Apple Orchards by Planting Well-feathered Trees/M.9 EMLA ('후지' 사과의 우량 측지묘/M.9 EMLA를 이용한 밀식재배원의 조기 생산성 평가)

  • Yang, Sang-Jin;Park, Moo-Yong;Song, Yang-Yik;SaGong, Dong-Hoon;Yoon, Tae-Myung
    • Horticultural Science & Technology
    • /
    • v.28 no.3
    • /
    • pp.374-380
    • /
    • 2010
  • Well-feathered (5.2 feathers, stem diameter 13 mm) trees of 'Fuji' apple/ M.9 EMLA were planted at $4.0{\tiems}1.5$ m and whip trees (stem diameter 10 mm) of 'Fuji'/M.26 at $4.0{\times}2.0$ m were trained to the slender spindle. The productivity and yield efficiency of two orchard systems were compared for 6 years. The canopy volume of the tree/M.9 EMLA reached $2.07m^3$ in 2nd year and increased slowly to almost the targeted tree volume of $2.9m^3$ in 4th year. Trees/M.26 grew slowly at the begin but from 3rd year the tree volume expanded quickly to reach $5.6m^3$ in 5th year, covering over the allowed space. Yield of M.9 EMLA per 10a increased from 0.3 ton in 2nd year to 4.6 ton in 5th year, and 5.0 ton in 6th year, but yield of M.26 per 10a increased from 0.5 ton in 3rd to 2.9 ton in 6th year. Cumulative yield per 10a up to 6th year was 13.9 ton for M.9 EMLA but only 9.8 ton for M.26. Fruit weight for M.9 EMLA was heavier than that for M.26. In conclusion, the high density planting system with well-feathered trees/M.9 EMLA was better than the conventional wide planting system with whip trees/M.26.

Influence of Seasonal incidence and Defoliation Degree of Marssonina Blotch on Fruit Quality and Shoot Growth of 'Fuji'/M.9 Apple Tree (갈색무늬병의 시기별 이병 및 낙엽 정도가 '후지'/M.9 사과나무의 과실품질 및 신초생장에 미치는 영향)

  • Park, Moo-Yong;Sagong, Dong-Hoon;Kweon, Hun-Joong;Do, Yun-Su;Song, Yang-Yik;Lee, Dong-Hyuk
    • Horticultural Science & Technology
    • /
    • v.31 no.5
    • /
    • pp.523-530
    • /
    • 2013
  • This study investigated the influence of seasonal incidence and defoliation degree caused by Marssonina blotch (Diplocarpon mali Harada et Sawamura) on shoot growth and fruit quality of 'Fuji'/M.9 apple tree. The occurrence of marssonina blotch in Gunwi region was observed from the mid of July 2009, and percentage of defoliation was about 10% in the end of October. In 2010, that started in the early of June. By the end of September, percentage of defoliation was 20% and it reached 50% in late October. Secondary growth of terminal shoot in 2010 was three times as much as that in 2009. In 2009, the soluble solid contents and the red color (hunter a value) during fruit maturation increased to $13.8^{\circ}Brix$ and 16.2, respectively. In 2010, the soluble solid content during fruit maturation remained in the $12.1-12.6^{\circ}Brix$ range after early October, and the red color began to increase after the end of September when the percentage of defoliation was 20%. As for fruit quality by defoliation degree, the red color decreased when defoliation percentage of bourse shoot at the end of October was more than 30%. Fruit weight and soluble solids also decreased when defoliation percentage was more than 50%. Fruit length and diameter of over 30% defoliation treatments begun to decrease after the middle of August, compared with those of under 30% defoliation treatment. Photosynthetic rate of the leaves that was located at the secondary growth of bourse shoot was similar to that of leaves which was located at the middle of bourse shoot. However, the size and the soluble solid content of fruit were not affected by photosynthesis activities of bourse shoot leaves which was develop in the secondary shoot growth.

Effect of Rainwater Sprinkling System Utilization for Reducing Heat Stress in Milking Cows during Intense Heat Time (폭염시 착유우 고온스트레스 경감을 위한 빗물관수시스템 이용 효과)

  • Choi, Dong-Yoon;Cho, Sung-Back;Park, Kyu-Hyun;Yang, Seong-Hak;Hwang, Ok-Hwa;Kwag, Jung-Hoon;Jeong, Kwang-Hwa;Song, Jun-Ik;Yoo, Yong-Hee;Ahn, Hee-Kwon
    • Journal of Animal Environmental Science
    • /
    • v.18 no.sup
    • /
    • pp.21-28
    • /
    • 2012
  • Since the temperature during summer is higher than the temperature which is suitable for milking cows, high temperature stress have severely affected dairy farmers due to decreased milk production. This study was carried out to investigate the effect of rainwater sprinkling system for reducing heat stress in milking cows during intense heat time. Treatment conditions were divided into 2 types ; No rainwater sprinkling (T1) and Rainwater sprinkling (T2). Temperature in the milking cow shed, feed intake, milk yield, respiration rate and rectal temperature were measured to investigate the effect of hot environment on the physiological, productive responses in milkig cows. The results obtained are summarized as follows : The daily milk yields were 24.5 and 27.4 kg per head in T1 and T2 during experimental period. The respiration rate was significantly higher in T1 than those of T2. The rectal temperature in T1 ($40.6^{\circ}C$) was higher than those of T2 ($39.8^{\circ}C$). It was suggested that rainwater sprinkling system installed in the dairy cow shed was effective means to reduce heat stress of milking cow.

Study on the Development of Measuring System for Fermentation Degree of Liquid Swine Manure Using Visible Ray (가시광선을 이용한 돈분뇨 액비 부숙도 측정장치 개발에 관한 연구)

  • Choi, D.Y.;Kwag, J.H.;Park, K.H.;Song, J.I.;Kim, J.H.;Kang, H.S.;Han, C.B.;Choi, S.W.;Lee, C.S.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.227-236
    • /
    • 2010
  • This study was conducted to develop an measuring system and method for fermentation degree of liquid swine manure by visible ray. The constituent changes of liquid swine manure were examined. pH gradually increased with time, but EC gradually decreased. Malodor strength decreased gradually with aeration treatment with time. Control needed more time to decrease malodor strength than aeration treatment. In aeration treatment, there was no germination of seeds (radish, chinese cabbage) up to 6 weeks and germination rate at 15th week was over 50%. However, in control, there was no germination up to end of experiment. Circular chromatography method showed that there was change after 10th week in aeration treatment but there was no change up to end of experiment in control. As a result, the fermentation degree of liquid swine manure would have relations among pH, EC, germination rate, malodor concentration, and reaction of circular chromatography. The simple analytical instrument for liquid swine manure consisted of a tungsten halogen and deuterium lamp for light source, a sample holder, a quartz cell, spectrometer for spectrum analyzer, a malodour measuring device, a software, etc. Results showed that the simple analytical instrument that was developed can approximately predict the fermentation degree of liquid swine manure by visible ray. Generally, the experiment proved that the simple analytical instrument was reliable, feasible and practical for analyzing the fermentation degree of liquid swine manure.

A Study on Livestock Odor Reduction Using Water Washing System (수세탈취시스템을 이용한 축산악취저감에 관한 연구)

  • Jeon, Kyoung-Ho;Choi, Dong-Yoon;Song, Jun-Ik;Park, Kyu-Hyun;Kim, Jae-Hwan;Kwag, Jung-Hoon;Kang, Hee-Sul;Jeong, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • The odor problem in the livestock is increasing by 7% annually. Most importantly, the livestock odor problem in swinery accounts for the maximum ratio (54%). In this study, we reviewed the possibility of deodorizing swinery using an odor reduction device that can be used with the water washing system. First, the study confirmed that the solubility of odor gas, which was hydrogen sulfide, was very low regardless of the contact time with solvent, but the solubility of methyl mercaptan was found to increase along with the increase in time. The solubility of other odor gases, such as dimethyl sulfide, dimethyl disulfide and ammonia, was considerably high. Consequently, it is considered that if the odor reduction device for the water washing system deodorization is used in a swinery, the time during which the exhaust gas is in contact with usable water must be extended, or solvent quantity must be expanded. However, it is predicted that although hydrogen sulfide is easily generated in the anaerobic condition, it is difficult to expect high odor reduction efficiency because this gas has low solubility in water, especially in case it is used in the deodorization of the water washing system. The result of the solubility experiment using the bench-scale device practically manufactured represented the higher odor reduction ratio than expected. This result was possible because the removal efficiency of dust particles could be reached up to 93%. Therefore, it is judged that also the odor gas absorbed on dust particles could be removed by removal of dust. Consequently, it is expected that the higher order reduction ratio will be possible by structural improvement for increasing contact with water and odor gas.

Effects of Concentration and Size of Porous Calcium Silicate (PCS) in Broiler Feeds on Performances, Fly Generation and Malodorous Gas Emission (Porous Calcium Silicate(PCS)의 급여수준 및 PCS 입자 크기가 육계의 성장, 파리 및 악취 발생에 미치는 영향)

  • Jeon, B.S.;Song, J.I.;Jeon, J.H.;Kwag, J.H.;Kang, H.S.;Choi, H.C.;Kim, T.I.;Lee, E.S.;Nahm, K.H.
    • Journal of Animal Environmental Science
    • /
    • v.15 no.2
    • /
    • pp.115-130
    • /
    • 2009
  • Three experiments on the addition of Porous Calcium Silicate (PCS) to broiler feed were conducted at different time periods in the same house. Each treatment had 4 replicates with 12 chicks in each treatment. Weight gain and feed intake were higher ($P{\le}0.05$) in the control groups. Feed conversions' were better ($P{\le}0.05$) in the PCS group, 3.0% PCS and 20 mesh size of PCS than the control group from 21 to 49 days, and for the overall period. $NH_3$ and $H_2S$. gas production were decreased ($P{\le}0.05$) when zeolite was added in broiler feeds. 1.5% or 3.0% PCS in broiler feed was better ($P{\le}0.05$) than the 4% PCS. More than 90 mesh size PCS was better ($P{\le}0.05$) in controlling $CO_2$ production in the 5th period than the 20 or 50 mesh size or control groups. The control and PCS groups produced more flies ($P{\le}0.05$) than zeolite group during the 2nd and 3rd weeks. The 3.0% or 4.5% PCS or 50 or 90 mesh size of PCS in broiler feed produced more flies than the 20 mesh size or control groups although 50 or 90 mesh size of PCS during 5th week tended to have lower fly production than the 20 mesh size of PCS and control group.

  • PDF

Effects of Different Ventilation Systems on Rearing Growing-finisher and Indoor Environment in a High Rise Hog Building (고상식 돈사내에서 환기시스템별 환경조사 및 육성비육돈 사육 효과)

  • Yoo, Y.H.;Jeong, J.W.;Park, K.H.;Song, J.I.;Ko, Y.G.;Kim, S.W.;Lee, I.B.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.193-204
    • /
    • 2010
  • The goal of this study was to develop a high-rise hog building(HRHB) for growing-fattening stages. HRHB was two story building and was suitable for specific environment in Korea. Manure was treated in a first floor and pigs were raised on the slatted second floor. Three ventilation systems - 1) duct inlet to wall exhaust system(V1), 2) eave inlet to wall exhaust system(V2), and 3) ceiling inlet to wall exhaust system(V3) - were used. This experiment was conducted during winter and from summer to fall. Air temperature, air speed, ammonia, hydrogen sulfide in HRHB, and swine growth rate were measured. During winter, air temperature in V1 system tended to be slightly high without any effect of outside air temperature. Maximum temperature from summer to fall was between 33.4 and $33.8^{\circ}C$ and there was no significant difference among systems. Continuously measured daily temperature was lower in V2 system than other systems and the fluctuation of air temperature was high. Air speed in V1 and V2 systems were similar (0.02~0.21 m/s), and was 0.04~0.15 m/s in V3 during winter. From summer to fall, air speed in V1, V2, and V3 systems were 0.10~0.41 m/s, 0.10~0.83 m/s, and 0.11~0.26 m/s, respectively. V2 system showed bigger fluctuation of air speed than other systems. During winter, the highest concentrations of ammonia in V1, V2, and V3 systems were 7.0, 3.5, and 8.7 ppm, respectively. Hydrogen sulfide was not detected. The highest concentrations of ammonia from summer to winter in V1, V2, and V3 systems were 6.1, 2.8, and 5.6 ppm, respectively. Swine growth showed no statistical significance among systems. However, daily weight gain was approximately 4% higher in V1 and V3 than in V2. Feed intake/daily weight gain was approximately 4% higher in V1 than other systems. From summer to fall, daily weight gain in V1 and V3 tended to approximately 3% higher than other systems, and feed intake/daily weight gain was approximately 2% higher in V1 than other systems. Hence, V2 system for the ventilation system of HRHB should not be utilized.

Evaluation on Heating Effects of Geothermal Heat Pump System in Farrowing House (지열 난방시스템을 이용한 분만돈사의 난방효과 분석)

  • Choi, H.C.;Park, Jae-Hong;Song, J.I.;Na, J.C.;Kim, M.J.;Bang, H.T.;Kang, H.G.;Park, S.B.;Chae, H.S.;Suh, O.S.;Yoo, Y.S.;Kim, T.W.
    • Journal of Animal Environmental Science
    • /
    • v.16 no.3
    • /
    • pp.205-215
    • /
    • 2010
  • Geothermal heat pump system (GHPS) is an energy-efficient technology that use the relatively constant and renewable energy stored in the earth to provide heating and cooling. With the aim of using GHPS as a heating source, it's possibilities of application in farrowing house were examined by measuring environmental assessment and sow's performance. A total of 96 sows were assigned to 2 pig housings (GHPS and conventional housing) with 48 for four weeks in winter season. During the experimental period, indoor maximum temperature in GHPS-housing was measured up to $26.7^{\circ}C$, average temperature could maintain $21.2^{\circ}C$. The mean value of dust levels and $CO_2$, $NH_3$ and $H_2S$ gas emissions were decreased in GHPS-housing compare with those of conventional housing. Litter size, birth weight, parity and weaning weight did not differ between housings. However, feed intake of sow in GHPS-housing was lower than that of conventional housing. In energy consumption for heating, electric power consumption increased in GHPS-housing than the conventional housing, a 2,250 kwh increase, whereas there is no fuel usage for heater in GHPS-housing. Amount of ground water circulated for heating in cold weather for earth heat exchanger was 8.4-12.9 ton per day. In conclusion, GHPS may have environmental benefits and effectiveness of heating in farrowing housing and affect the performance in sows.

Study on the Ventilation System Applicability of High-rise Hog Building for Growing-fattening (고상식 육성비육돈사에 적합한 환기시스템에 관한 연구)

  • Yoo, Yong-Hee;Song, Jun-Ik;Choi, Dong-Yoon;Chung, Eui-Soo;Jeon, Kyoung-Ho;Lee, Poong-Yeon;Kim, Sang-Woo;Jeung, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 2010
  • The goal of this study was to develop a suitable ventilation system for high-rise hog building (HRHB) for growing-fattening with combined slatted floor pen in second story and in situ manure management system in Korea. The HRHB was constructed as 29m long, 9m wide and 7.6m high for outer dimension with an indoor height of 3.1m and 2.4 for lower and upper floor, respectively. Ventilation systems for each treatment were installed in separated rooms of HRHB. The ventilation types installed in each room were following 3 types: ventilation type 1 (V1), where air was pulled through a circular duct inlet and exhausted by fans; ventilation type 2 (V2), where air was pulled through eave inlet (side ceiling inlet) and exhausted by fans; and ventilation type 3 (V3), where air was pulled through baffled ceiling inlet and exhausted by fans. For each ventilation system, investigated air velocity under minimum, medium and maximum ventilation ratio and air flow pattern inside. The results were as follows; For air flow pattern from top to bottom, V1 showed a homogeneous vertical type, V2 showed a bilateral symmetry type and V3 showed an vertical umbrella type. Under minimum ventilation ratio, air velocity in upper floor (80cm above the slated floor) was similar for V1, V2, and V3. Under maximum ventilation ratio, air velocity in upper floor was undeviating for V1 (0.10~0.26m/s) and varied for V2 (0.12~0.63m/s) while those for V3 was relatively slow and less varied (0.07~0.15m/s). In conclusion, Duct inlet type (V1) can be applied to the development of a new HRHB with additional evaluations such as field test hog feeding.