• Title/Summary/Keyword: Korean medical

Search Result 64,496, Processing Time 0.093 seconds

Investigation of Domestic and Foreign Unexpected Antibodies for Emergency Blood Transfusion (응급수혈을 위한 비예기 항체의 국내·외 실태조사)

  • Weonjoo, Hwang;Sang-Hee, Lee;Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.279-284
    • /
    • 2022
  • Certain pre-transfusion tests are not commonly performed during emergency blood transfusion. In this study, we reviewed and analyzed the data of post-blood transfusion antibody screening tests to establish the effects of unexpected antibodies causing hemolytic transfusion reactions. We reviewed information published domestically and internationally, and selected the data of 68,602 antibody screening tests and 528 antibody identification tests conducted at P hospital. We found that unexpected antibody positive (1198,1.74%), Rh type (161, 30.49%), Lewis type (67, 12.69%), others (Di (a), 28, 5.30%). The anti-E type positive was 93 (17.61%), and that of the cases with anti-C (13, 2.46%). Only data of domestic cases were included for analysis that were published before 2007, which established the presence of antibodies of the following types and numbers of cases: anti-E (196, 22.45%), anti-Le a (82, 9.39%), and anti-E+C (60, 6.87%). In 2018, anti-E (107, 17.12%), anti-E+Canti-E+C (56, 8.96%), and anti-Di a (28, 4.48%) were detected. In other domestic cases, S hospital was detect to anti-E, anti-Le a, anti-E+C. The Anti-E, anti-D, anti-E+C, and anti-C+E were detected in D hospital. In Saudi Arabia, Anti-D, anti-E, and anti-Jka was detected. The Anti-M, Anti-N, Anti-Le (a), and Anti-D were detected in India. Requests for emergency blood transfusion increased 1.8 times after the opening of the trauma center. This study has the disadvantage of being a cross-sectional study. additional studies are needed to provide basic information on alternative treatments that can increase the safety and reduce the side effects of hemolytic transfusion in emergency transfusion situations.

A Study on the Status and Editors' Perceptions of the Data Sharing Policies of International Journals Published in Korea (한국의 국제 학술지 데이터 공유 정책 현황 및 편집인 인식에 관한 연구)

  • Seo Young Bai;Jihyun Kim
    • Journal of the Korean Society for information Management
    • /
    • v.40 no.3
    • /
    • pp.25-54
    • /
    • 2023
  • At a time when open data receives attention as an international trend, there is a need to discuss the role of international journals in Korea to support data sharing. Based on surveys and interviews of editors from the international journals, we identified factors affecting the policy adoption and examined the journal editors' perception on the adoption and components of the data sharing policy. As a result, scholarly journals that have adopted or are planning to adopt policies have recognized that data sharing is an international trend and can contribute to research development, but they stressed that efforts to improve the perception of data sharing were still necessary. Educational activities and compensation for sharing data were needed at scholarly journals' and communities' level. Also, components perceived important and selected by more than half of the editors as mandatory were 'data availability statement', 'data sharing level', 'data sharing method', and 'data citation'. While scholarly journals do not always need to mandate data sharing, it was necessary to mention conditions where data cannot be shared through data availability statements. The role of the organization developing and operating a repository appropriate for situations in Korea was also emphasized. In addition, by identifying factors affecting the policy adoption, significant differences were found in Journal Impact Factor quartiles, publication type, and subject area. This finding indicated that journals with a high impact factor are likely to have resources to support data sharing, and open access or hybrid journals are likely to have interest in open data as a part of open science. In the medical research area, active movements for data sharing in academic communities have promoted the adoption of data sharing policies. This study would be used as basic data to facilitate the adopton and operation of scholarly journals' data sharing policies in Korea.

Prevalence and Patterns of Congenitally Missing Teeth among Pediatric Patients Aged 8 - 16 in Pusan National University Dental Hospital (부산대학교 치과병원에 내원한 8 - 16세 환자의 선천성 치아 결손 유병률 및 유형 평가)

  • Eunjin Kim;Soyoung Park;Eungyung Lee;Taesung Jeong;Jonghyun Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.50 no.2
    • /
    • pp.179-191
    • /
    • 2023
  • The purpose of this study was to investigate the prevalence and patterns of congenitally missing teeth in permanent teeth excluding third molars, in patients aged 8 to 16 years who visited Pusan National University Dental Hospital from January 2010 to February 2021. This retrospective study evaluated tooth agenesis and the pattern of missing teeth represented by the tooth agenesis code by reviewing panoramic radiographs and electronic medical records of 11,759 patients, including 5,548 females and 6,211 males. The prevalence of congenitally missing teeth was 10.74% (females 11.95%, males 9.66%, p < 0.0001). Patients with tooth agenesis had an average of 2.22 missing teeth, and congenitally missing teeth occurred more frequently in the mandible (8.39%) than in the maxilla (4.52%, p < 0.0001). The mandibular second premolar (58.19%) was the most frequently missing tooth. The second premolar was the most frequently missing tooth in all quadrants (30.10%, 31.67%, 43.14%, and 35.59%) when a single tooth was absent, while the first and second premolars were the most commonly absent teeth (11.69%, 11.47%, 5.94%, and 5.24%) when two or more teeth were missing. In the relationship between maxillary-mandibular antagonistic quadrants and full mouth, the 1st to 4th place of the missing patterns were all involved with the 1st and 2nd premolars. This study can be clinically helpful in establishing a treatment plan for patients with missing teeth. In addition, it can be used as basic data for molecular biological research to find out the relationship between tooth agenesis and specific genes.

Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position (구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구)

  • Soo-Young Hong;Seon-Ki Lee;Jin-Han Lee;Jae-In Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.2
    • /
    • pp.101-112
    • /
    • 2023
  • Purpose. This retrospective study was to investigate the survival and complication rates of posterior single implant according to the implant diameters, lengths and position. Materials and methods. Patients who had been restored single implant prosthesis in the posterior area by the three prosthodontists in the department of prosthodontics, Daejeon dental hospital of Wonkwang university, in the period from February 2014 to May 2018 were selected for the study. A total of 505 patients with 697 implants were observed. The survival and complications of implants were investigated using electronic medical records and radiographs. Fixture diameters, lengths, position, patient's sex and age were assessed as possible factor affecting the survival and complications of implants. Results. 3-year cumulative survival rates of posterior single implants were 98.5% and 5-year cumulative survival rates were 94.4%. 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm (97.0%) than implants with diameter ≤ 4.0 mm (89.5%), and in females (98.8%) than males (92.4%). There were statistically significant differences (P < .05). The mechanical complication rate was 20.1% and the biological complication rate was 4.7%. Complications occurred in order of abutment screw loosening (7.5%), decementation (6.3%), proximal contact loss (3.7%) and so on. Abutment screw loosening occurred more frequently in the lower molar region (10.5%), in males (9.5%) than females (5.1%), and in patients aged < 65 years (9.4%) than patients aged ≥ 65 years (5.1%). There were statistically significant differences (P < .05). Conclusion. The 5-year cumulative survival rates were higher in implants with diameter > 4.0 mm than implants with diameter ≤ 4.0 mm and in females than males. Abutment screw loosening which was the most commonly occurring complication occurred more frequently in the lower molar region, in males than females, and in patients aged < 65 years than patients aged ≥ 65 years. There were statistically significant differences.

Protective Effects of Trifolium pratense L. Extract against H2O2-induced Oxidative Stress in HaCaT Keratinocytes (인간 피부각질세포에서 Hydrogen peroxide로 유도된 산화적 스트레스에 대한 붉은 토끼풀 추출물의 세포 보호 효과)

  • Mi Song Shin;You Kyeong Lee;Seo Young Choi;Ji Sun Hwang;Parkyong Song;Hyeon Cheal Park;Keun Ki Kim;Hong-Joo Son;Yu-Jin Kim;Kwang Min Lee
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.2
    • /
    • pp.223-232
    • /
    • 2023
  • Oxidative stress plays a significant role in the pathogenesis of various skin conditions, resulting in cellular and tissue damage that can contribute to the development of skin tone unevenness, roughness and wrinkles. In this study, we found that Trifolium pratense L. extract (TE) attenuated oxidative-induced damage in HaCaT cells and elucidated the underlying molecular mechanism. Our finding demonstrated that TE effectively protected HaCaT cells against H2O2-induced cell death by inhibiting caspase-3 activation, downregulating Bax and upregulating Bcl-2, and attenuating the activation of three mitogen-activated protein kinases (MAPKs). Our results suggest that TE has remarkable cytoprotective properties against oxidative damage in HaCaT cells and could serve as a complementary or alternative approach to prevent and treat skin damage.

Comparative Study of Compliance for Venous Thromboembolism Prophylaxis (American College of Chest Physicians Guideline and American College of Orthopedic Surgeons Guideline) in High Risk Patients with a Venous Thromboembolism (정맥혈전 색전증 고위험군에서 시행한 혈전색전 예방요법(American College of Chest Physicians 지침 및 American College of Orthopedic Surgeons 지침)의 준수율 비교 연구)

  • Suh, You-Sung;Nho, Jae-Hwi;Jang, Byung-Woong;Kang, Deokwon;Won, Sung-Hun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.4
    • /
    • pp.317-326
    • /
    • 2019
  • Purpose: To compare and analyze the rate of prevention of two venous thromboembolism prophylaxis guidelines in patients with artificial joint arthroplasty and hip joint fracture. Proper prophylaxis for preventing thromboembolism in orthopedic surgery is significant because of this fetal complication. Materials and Methods: This study compared and retrospective analyzed the rate of prevention using the medical records and radiographs of patients who underwent orthopedic surgery from March 2009 to February 2011 according to the American College of Chest Physicians (ACCP) guidelines and from March 2012 to February 2014 according to the American Academy of Orthopedic Surgeons (AAOS) guidelines. Results: The guidelines for venous thromboembolism prophylaxis have been applied to patients with artificial joint replacement and hip joint fracture, the compliance rate of the ACCP guidelines was 56.0% before surgery, 67.0% after surgery with chemical prophylaxis, and 80.5% with mechanical prophylaxis. In addition, the compliance rate of the AAOS guidelines was 74.1% with chemical prophylaxis, and 88.3% with mechanical prophylaxis, which was higher than the ACCP guidelines. The compliance rates of mechanical and chemical prophylaxis before and after surgery of the ACCP guidelines, and the compliance rate of mechanical and chemical prophylaxis of the AAOS guidelines were compared and analyzed. The results revealed statistical significance (p<0.05) before and after total knee replacement arthroplasty and hip joint fracture internal fixation and total high risk orthopedic surgery. Conclusion: Raising the compliance rate of prophylaxis of venous thromboembolism in high risk orthopedic surgery is necessary and people should follow the guidelines for a unified direction depending on which situation they are in.

Comparison of the Outcomes after Primary Total Hip Arthroplasty Using a Short Stem between the Modified Anterolateral Approach and Direct Anterior Approach with a Standard Operation Table (일반 수술 침대와 짧은 대퇴 주대를 이용한 인공 고관절 전 치환술의 직접 전방 도달법과 변형된 전 측방 도달법에 따른 결과 비교)

  • Park, Myung-Sik;Yoon, Sun-Jung;Choi, Seung-Min;Cho, Hong-Man;Chung, Woochull;Kang, Kyung-Rok
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.244-253
    • /
    • 2019
  • Purpose: Total hip arthroplasty was performed using a direct anterior approach (DAA) on an ordinary operation table and a short femoral stem. The clinical radiographic results were evaluated by a comparison with those performed using the modified hardinge (anterolateral approach, ALA) method. Materials and Methods: From January 2013 to November 2015, 102 patients who underwent total hip arthroplasty using DAA (DAA group) and the same number of patients using ALA (ALA group), both performed by a single surgeon, were compared and analyzed retrospectively. The operation time and amounts of bleeding were compared, and the improvement in post-operative pain, ambulatory capacity and functional recovery of the hip joint were checked. The location of insertion of the acetabular cup and femoral stem were evaluated radiologically, and the complications that occurred in the two groups were investigated. Results: The amount of bleeding was significantly smaller in the DAA group (p=0.018). Up to 3 weeks postoperatively, recovery of hip muscle strength was significantly higher in the DAA group (flexion/extension strength p=0.023, abduction strength p=0.031). The Harris hip score was significantly better in the DAA group for up to 3 months (p<0.001) and the Koval score showed significantly better results in the DAA group up to 6 weeks (p≤0.001). The visual analogue scale score improvement was significantly higher in the DAA group by day 7 (p=0.035). The inclination angle (p<0.001) and anteversion angle (p<0.001) of the acetabular cup were located in the safe zone of the DAA group more than in the ALA group, and there was no statistically significant difference in the position of the femur stem and leg length difference. During surgery, two cases of greater trochanter fracture occurred in the DAA group (p=0.155). Conclusion: The DAA performed in the ordinary operation table using a short femoral stem showed post-operative early functional recovery. Because a simple to use fluoroscope was used during surgery with an anatomical position familiar to the surgeon, it is considered to be useful for the insertion of implants into the desired position and for an approach that is useful for the prevention of leg length differences.

Incidence and Associated Factors of Delirium after Orthopedic Surgery (정형외과 수술 후 발생한 섬망의 발생 빈도와 관련 인자)

  • Lee, Si-Wook;Cho, Chul-Hyun;Bae, Ki-Cheor;Lee, Kyung-Jae;Son, Eun-Seok;Um, Sang-Hyun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.157-163
    • /
    • 2019
  • Purpose: To investigate the incidence and associated factors of delirium after orthopedic surgery. Materials and Methods: A total of 2,122 cases, who were older than 20 years and underwent orthopedic surgery at a single medical center during a one year period were included. Among them, 132 patients who were diagnosed with delirium after surgery under the Diagnostic and Statistical Manual of Mental Disorders-V criteria and medicated under the consultation of a psychiatrist were included in the study The differences in the incidence of delirium and several affecting factors were analyzed. Results: The overall incidence of delirium after surgery was 6.2% (132 in 2,122 cases). The mean age of the delirium group was 77.4 years (range, 54-92 years), which was higher than that of the non-delirium group (58.1 years). The percentage of women in the delirium group was 63.6% (84 in 132 cases), which was higher than that of the women in the non-delirium group (49.0%). The incidence of delirium after surgery was 9.3% (85 in 916 cases) due to trauma and 3.9% (47 in 1206 cases) due to disease. The incidence of postoperative delirium according to the surgical region was 29.2% (7 in 24 cases) in two or more regions, 13.7% (72 in 526 cases) in the hip, and 9.6% (14 in 146 cases) in the spine, 3.5% (20 in 577 cases) in the knee-lower leg, 2.5% (5 in 199 cases) in the foot-ankle, 2.4% (11 in 457 cases) in the shoulder-elbow, and 1.6% (3 in 189 cases) in the forearm-wrist-hand. Delirium occurred more rapidly in women and surgery due to disease, and the duration of delirium was longer in patients with dementia and major depressive disorders. Conclusion: The incidence of postoperative delirium was high in cases of surgery due to trauma and in cases of surgery in two or more sites. The incidence of postoperative delirium according to a single surgical region was higher in the order of the hip, spine, and knee. Active intervention is needed regarding the correctable risk factor.

Image Evaluation for Optimization of Radiological Protection in CBCT during Image-Guided Radiation Therapy (영상유도 방사선 치료 시 CBCT에서 방사선 방호최적화를 위한 영상평가)

  • Min-Ho Choi;Kyung-Wan Kim;Dong-Yeon Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.305-314
    • /
    • 2023
  • With the development of medical technology and radiation treatment equipment, the frequency of high-precision radiation therapy such as intensity modulation radiation therapy has increased. Image-guided radiation therapy has become essential for radiation therapy in precise and complex treatment plans. In particular, with the introduction of imaging equipment for diagnosis in a linear accelerator, CBCT scanning became possible, which made it possible to calibrate and correct the patient's posture through 3D images. Although more precise reproduction of the patient's posture has become possible, the exposure dose delivered to the patient during the image acquisition process cannot be ignored. Radiation optimization is necessary in the field of radiation therapy, and efforts to reduce exposure are necessary. However, when acquiring 3D CBCT images by changing the imaging conditions to reduce exposure, there should be no image quality or artefacts that would make it impossible to align the patient's position. In this study, Rando phantom was used to scan and evaluate images for each shooting condition. The highest SNR was obtained at 100 kV 80 mA 25 ms F1 filter 180°. As the tube voltage and tube current increased, the noise decreased, and the bowtie filter showed the optimal effect at high tube current. Based on the actual scanned images, it was confirmed that patient alignment was possible under all imaging conditions, and that image-guided radiation therapy for patient alignment was possible under the condition of 70 kV 10 mA 20 ms F0 filter 180°, which showed the lowest SNR. In this study, image evaluation was conducted according to the imaging conditions, and low tube voltage, tube current, and small rotation angle scan are expected to be effective in reducing radiation exposure. Based on this, the patient's exposure dose should be kept as low as possible during CBCT imaging.

Research on Radiation Shielding Film for Replacement of Lead(Pb) through Roll-to-Roll Sputtering Deposition (롤투롤 스퍼터링 증착을 통한 납(Pb) 대체용 방사선 차폐필름 개발)

  • Sung-Hun Kim;Jung-Sup Byun;Young-Bin Ji
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.441-447
    • /
    • 2023
  • Lead(Pb), which is currently mainly used for shielding purposes in the medical radiation, has excellent radiation shielding functions, but is continuously exposed to radiation directly or indirectly due to the harmfulness of lead itself to the human body and the inconvenience caused by its heavy weight. Research on shielding materials that are human-friendly, lightweight, and convenient to use that can block risks and replace lead is continuously being conducted. In this study, based on the commonly used polyethylene terephthalate (PET) film and the fabric material used in actual radiation protective clothing, a multi-layer thin film was realized through sputtering and vacuum deposition of bismuth, tungsten, and tin, which are metal materials that can shield radiation. Thus, a shielding film was produced and its applicability as a radiation shielding material was evaluated. The radiation shielding film was manufactured by establishing the optimized conditions for each shielding material while controlling the applied voltage, roll driving speed, and gas supply amount to manufacture the shielding film. The adhesion between the parent material and the shielding metal thin film was confirmed by Cross-cut 100/100, and the stability of the thin film was confirmed through a hot water test for 1 hour to measure the change of the thin film over time. The shielding performance of the finally realized shielding film was measured by the Korea association for radiation application (KARA), and the test conditions (inverse wide beam, tube voltage 50 kV, half layer 1.828 mmAl) were set to obtain an attenuation ratio of 16.4 (initial value 0.300 mGy/s, measured value 0.018 mGy/s) and damping ratio 4.31 (initial value 0.300 mGy/s, measured value 0.069 mGy/s) were obtained. by securing process efficiency for future commercialization, light and shielding films and fabrics were used to lay the foundation for the application of films to radiation protective clothing or construction materials with shielding functions.