• 제목/요약/키워드: Korean liquid

검색결과 17,437건 처리시간 0.04초

Comparison of Liquid-based Cytology and Conventional Smear in the Evaluation of Sputum Cytology

  • Back, Oun-Cheol
    • 대한임상검사과학회지
    • /
    • 제45권1호
    • /
    • pp.26-31
    • /
    • 2013
  • The cytology of sputum specimens, at a medical facility in Korea, is using the liquid-based cytology and conventional smear method. It confirms the diagnosis using conventional smear methods and the liquid-based cytology. In addition, the diagnosis uses two kinds of each method, compares the suitability, sensitivity and specificity for each test and tries to understand the efficient method needed. It divided sputum specimens in half and liquid-based cytology. A conventional smear method was conducted and the Papanicolaou's staining was conducted using Autostainer. Diagnosed each slide of staining produced smear slides specimens by using an optical microscope. The result of the liquid-based cytology and conventional smear method was that the liquid-based cytology was of a higher-grade than the conventional smear method. It was 36.8%, and 62.8% in the same condition. But only one case was of a lower grade. Liquid-based cytology showed 86.2% of adequacy, 31.0% of sensitivity and 97.5% of specificity. The conventional smear method showed 54.4% of adequacy, 19.6% of sensitivity and 100% of specificity. If it was conducted with two methods at the same time, the results would be similar to the liquid-based cytology. In conclusion, liquid-based cytology has a more superior adequacy and sensitivity than the conventional smear method. The combination of the two methods is similar to the result of only conducting a liquid-based cytology. Conducting a liquid-based cytology rather than the combination of the two ways of sputum cytoscopy, is to be considered as an efficient method to achieve diagnostic accuracy, reduce labor of clinical technologist and pathologist, and to reduce the expense of patients.

  • PDF

액상 과망간산칼륨 적용시 육계 깔짚의 특성 평가 (Assessing the Impact of Liquid Potassium Permanganate on Litter Quality of Poultry)

  • 최인학
    • 한국환경과학회지
    • /
    • 제29권1호
    • /
    • pp.119-122
    • /
    • 2020
  • The effects of liquid potassium permanganate (KMnO4) on the litter quality of poultry were investigated. Two-hundred-forty 0-day-old broiler chickens (Arbor Acres) were randomly assigned to two treatments with four replicated pens of 30 chickens each. Treatment liquid KMnO4 at a rate of 50 g of liquid KMnO4/kg of poultry litter was sprayed onto the litter surface using a small hand pump; others served as a control that was applied without liquid KMnO4 additions. Compared with controls, the treatment liquid KMnO4 showed no differences in pH, total nitrogen and ammonia concentration. It was concluded that liquid KMnO4 did not significantly increase poultry litter quality. Mechanisms relating to increasing litter pH and ammonia using liquid KMnO4 are an oxidant agent (not acid-foaming agents).

Rene80/B/Rene80계의 액상확산 접합과정 -B분말 도포법을 이용한 액상확산접합 (Liquid Phase Diffusion Bonding Procedure of Rene80/B/Rene80 System -Liquid Phase Diffusion Bonding Using B Powder Coating Method)

  • 정재필;강춘식
    • Journal of Welding and Joining
    • /
    • 제13권2호
    • /
    • pp.132-138
    • /
    • 1995
  • Rene80 superalloy was liquid phase diffusion bonded by using boron(B) as an insert material, where B has high diffusivity and higher melting point as an insert material. Bonding procedure and bonding mechanism of Rene80/B/Rene80 joint were investigated. As results, liquid metal was produced by solid state reaction between base metal and insert material on bonding zone. The liquid metal was produced preferentially at the grain boundary. Except for production of liquid metal, other bonding procedure was nearly same as TLP(Transient Liquid Phase) bonding. Bonding time, however, was reduced compared to prior result of TLP bonding. By bonding S.4ks at l453K, Ren80/B/Rene80 joint was isothermally solidified and homogenized where thickness of insert material was 7.5.mu.m.

  • PDF

평면 교반조에서의 $CO_2$ 기체흡수에서 교반속도에 따른 기-액 계면 면적에 관한 연구 (A Study on Gas-Liquid Interfacial Areas with the Stirrer Spends for A$CO_2$bsorption in Agitated Vessel)

  • 박문기;문영수
    • 한국환경과학회지
    • /
    • 제3권4호
    • /
    • pp.403-408
    • /
    • 1994
  • Catalytic slurry reactors, in which a solid maintained in the rom of fine particles suspended in a liquid, are frequently used in chemical and biochemical and industries. In these processes the particle loading is normally low so that the effects of particles on the liquid-film mass transfer coefacent and the gas-liquid interface area are assumed to be negligible. But it is known from the works, amongst others, that the finely powdered activated carbon can increase the gas-liquid mass transfer significantly in surface-aerated reactors. The stirred cell (13.2cm inside diameter) contained four baffles and at the stirring speeds range of 80 ∼ 300ppm, the gas-liquid interfacial area could be considered as that of the cross section of the vessel (that is, 130.1cm2). When the stirrer speeds were increased, the effective interfacial area was slightly higher than the geometric area and was obtained experimentally from the Danckwerts plots. Key Words : gas-liquid interfacial area, Duckwert's Plot stirred dell. mass transfer coefficient.

  • PDF

Simulation Study of an e-Beam Addressed Liquid Crystal Display for Projection

  • Zhou, Fushan;Yang, Deng-Ke;Molitor, R.J.
    • Journal of Information Display
    • /
    • 제3권4호
    • /
    • pp.8-12
    • /
    • 2002
  • We have carried out a simulation study on an e-beam addressed liquid crystal projection display in which the liquid crystal is switched by the electric field of the charge, produced by an electron beam, on the surface of the display. We calculated the electric field produced by the surface charge, the liquid crystal director configuration and the profile of the transmitted light. We studied the factors affecting the resolution of the display and the effect of pretilt angle on the performance of the display. The e-beam addressed liquid crystal projection display potentially has the advantages of high resolution and high brightness.

Dielectric and Electro-Optical Properties of Ceramic Nanoparticles Doped Liquid Crystals

  • Porov, Preeti;Chandel, Vishal Singh;Manohar, Rajiv
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권2호
    • /
    • pp.69-78
    • /
    • 2016
  • Liquid crystals are important materials because of their applications in display technology and many other scientific applications. Different mixtures of liquid crystals and their doped samples have gained interest because a single liquid crystal compound cannot fulfill all the required parameters for the display application. The doping can be accomplished with dyes, polymers, or composite nanoparticles among other substance. The addition of nanoparticles can modify the physical properties of the host liquid crystal and enhances the performance of electro-optical devices. The present study is focused on investigations of possible changes in dielectric and electro optical properties of liquid crystals caused by doping with ceramic nanoparticles. Including smaller nanoparticles were found to be better candidates for use in suppressing the unwanted ion effects in liquid crystal displays.

Ni/B/Ni 액상확산접합계의 액상폭에 관한 연구 (A Study on the Width of Liquid Layer of Ni/B/Ni Diffusion Bonding System)

  • 정재필;강춘식
    • Journal of Welding and Joining
    • /
    • 제13권4호
    • /
    • pp.147-154
    • /
    • 1995
  • In order to study the bonding mechanism of Ni/B/Ni transient liquid phase bonding system, width of liquid layers were calculated, where in this system melting point of insert material(B) is higher than bonding temperature and melting point of base metal(Ni). Caclulated values were compared with experimental ones which were measured by bonding Ni/B/Ni system at 1433-1474K under vacuum atmosphere. As results, the width of initial liquid layer of Ni/B/Ni system was calculated as $W_{IL}$ = $W_{o}$[1 + {2.100..rho.$_{S/}$ ( $X_{3}$ + $X_{4}$)..rho.$_{Ni}$ }-.rho.$_{S/}$.rho. Ni/], and it was nearly same with experimental values. Maximum width of liquid layer, width of liquid layer during isothermal solidification and isothermal solidification time were calculated also.o.o.o.

  • PDF

GH형 LCD에 있어서 액정 및 2색성 색소의 분자형상과 배향질서도와의 관계 (Relation between molecular structure and order parameter of liquid crystals and dyes in GH-LCD)

  • 박우상
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권10호
    • /
    • pp.989-994
    • /
    • 1997
  • In a Guest-Host cell the orientational ordering of dyes doped into liquid crystals has been investigated. To evaluate the influence of the host liquid crystals on the ordering of the dyes we have measured precisely the ordering parameters of the liquid crystals by using the dichroic ratio of the absorbances for infrared light polarized parallel and perpendicular to the diector. Our experimental results show that the ordering of the dyes can be expressed as a function of not only the molecular structure of the dyes but also the order parameter of the liquid crystals. These functions are dependent on the kinds of the liquid crystals and the dyes. Particularly the combination such as anthraquinone dyes doped into cyanobiphenyl liquid crystals show a very high ordering parameter. This is considered due to a strong intermolecular interaction between the dipoles of both liquid crystals and dyes.

  • PDF

The Vibration Performance Experiment of Tuned Liquid Damper and Tuned Liquid Column Damper

  • Kim Young-Moon;You Ki-Pyo;Cho Ji-Eun;Hong Dong-Pyo
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.795-805
    • /
    • 2006
  • Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs ; easy to install in existing structures : effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.

Diffusion Range and Pool Formation in the Leakage of Liquid Hydrogen Storage Tank Using CFD Tools

  • Kim, Soohyeon;Lee, Minkyung;Kim, Junghwan;Lee, Jaehun
    • 공업화학
    • /
    • 제33권6호
    • /
    • pp.653-660
    • /
    • 2022
  • In liquid hydrogen storage tanks, tank damage or leakage in the surrounding pipes possess a major risk. Since these tanks store huge amounts of the fluid among all the liquid hydrogen process facilities, there is a high risk of leakage-related accidents. Therefore, in this study, we conducted a risk assessment of liquid hydrogen leakage for a grid-type liquid hydrogen storage tank (lattice-type pressure vessel (LPV): 18 m3) that overcame the low space efficiency of the existing pressure vessel shape. Through a commercially developed three-dimensional computational fluid dynamics program, the geometry of the site, where the liquid hydrogen storage tank will be installed, was obtained and simulations of the leakage scenarios for each situation were performed. From the computational flow analysis results, the pool formation behavior in the event of liquid hydrogen leakage was identified, and the resulting damage range was predicted.