• 제목/요약/키워드: Korean inclination

검색결과 1,590건 처리시간 0.028초

경사진 평행평판 내 혼합대류 열전달 특성에 관한 수치적 연구 (A Numerical Study on the Characteristic of Mixed Convection Between Inclined Parallel Plates)

  • 박일용;배대석;권오붕
    • 동력기계공학회지
    • /
    • 제10권2호
    • /
    • pp.29-35
    • /
    • 2006
  • Two-dimensional numerical simulation has been performed to investigate mixed convection heat transfer between inclined parallel plates with bottom-heated and top-cooled uniformly. The ratio of parallel plate length to height is 9.33, Prandtl number is 909(that of silicone oil at 298K) and Rayleigh number is 8600. In the ranges of the Reynolds number Re from 0 to 1.8 and the angle of inclination ${\theta}$ from 0 to 90 degree. The governing equations are discretized using the finite volume method. In this study, the effects of the Reynolds number, the angle of inclination, and the local and mean Nusselt numbers are presented and discussed. It is found that the periodic flow of mixed convection between inclined parallel plates is shown at $0^{\circ}{\leq}\;{\theta}<30^{\circ},\;Re<0.063$, and the flow pattern can be classified into three patterns which depend on Reynolds number and the angle of inclination. The minimum average Nusselt numbers occur at Re=0.05 regardless of the angle of inclination.

  • PDF

A Comparison of the Heat Transfer Performance of Thermosyphon Using a Straight Groove and a Helical Groove

  • Han Kyuil;Cho Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • 제19권12호
    • /
    • pp.2296-2302
    • /
    • 2005
  • This study is focused on the comparison of heat transfer performance of two thermosyphons having 60 straight and helical internal grooves. Distilled water has been used as working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, the inclination angle and operating temperature were used as experimental parameters. The heat flux and heat transfer coefficient are estimated from experimental results. The conclusions of this study may be summarized as follows; Liquid fill charge ratio, inclination angle and geometric shape of grooves were very important factors for the operation of thermosyphon. The optimum liquid fill charge ratio for the best heat flux were $30\%$. The heat transfer performance of helically grooved tube was higher than that of straight grooved tube in low inclination angle (less than $30^{\circ}$), but the results were opposite in high inclination angle (more than $30^{\circ}$). As far as optimum inclination angle concerns, range of $25^{\circ}\~30^{\circ}$ for a helically grooved tube and about $40^{\circ}$ for a straight grooved tube are suggested angles for the best results.

Shade Avoidance and the Regulation of Leaf Inclination in Rice

  • Shin, Juhee;Park, Phun Bum
    • Rapid Communication in Photoscience
    • /
    • 제3권3호
    • /
    • pp.53-55
    • /
    • 2014
  • The shade avoidance syndrome is a morphological and physiological response when plants are exposed to shade. Recent work in Arabidopsis had begun to define the molecular components of the shade avoidance syndrome in dicotyledonous model plant. However, little is known about the shade avoidance response networks in agriculturally important monocotyledon crops such as rice. Here, we found that the degree of bending at the lamina joint is inversely proportional to the R:FR ratio. To elucidate which phytochrome is involved in this response, we did lamina joint inclination assay with the rice phytochrome-deficient mutants (osphyA, osphyB, and osphyC) and the wild type plants. Whereas the osphyA and osphyC knockout mutants bent at the lamina joint in the far-red rich condition as the wild type plants, the osphyB knockout mutants no longer bent at the lamina joint in the far-red rich condition. These results suggest that PHYB acts as a sole photoreceptor in the lamina joint inclination response in rice.

경지 균평 작업을 위한 자동 표고 측정에 관한 연구 (A Study on the Automatic Level Measurement for Land Leveling)

  • 김종안;김수현;곽윤근
    • Journal of Biosystems Engineering
    • /
    • 제22권3호
    • /
    • pp.269-278
    • /
    • 1997
  • An automatic level measurement system was developed to level the land fer direct seeding of rice. A laser transmitter/receiver set was used to measure land-level. The inclination error occurred in level measurement on irregular land surface could be compensated by attaching rotating mass. The level measuring experiments were performed on three kinds of different shapes(step, random, sine). This system could accurately measure step level of which amplitude was 40mm in 0.5s, random level change within $\pm$ 5mm maximum measurement error, and sine level change of which spatial frequency was 0.5m-1. To verify performance of the inclination error compensation system, frequency transfer function(acceleration input vs. inclination error) was computed by spectral analysis. The inclination error was decreased about 20㏈ by error compensation system.

  • PDF

낮은 핀을 가진 경사 써모사이폰의 열전달 성능에 관한 실험적 연구 (Experimental study on heat transfer inside inclined thermosyphon with low integral-fins)

  • 조동현;권혁홍
    • 설비공학논문집
    • /
    • 제10권2호
    • /
    • pp.165-172
    • /
    • 1998
  • An experimental study on the heat transfer of the inclined thermosyphon with low integral-fins in which boiling and condensation occurred is performed to investigate its heat transfer performance. Water and CFC-30 have been used as the working fluids. The operating temperature and the inclination angle of thermosyphon have been used as the experimental parameters. The heat flux input and the inclination angle $\theta$ towards the vertical position were varied in steps. The heat transfer rate in the thermosyphon was depended upon the inclination angle. In addition, it is to obtain the overall heat transfer coefficients and the characteristics as a operating temperature for the practical applications.

  • PDF

원통형 용기내의 상변화물질에서의 응고 열전달에 관한 연구 (경사각 변화의 영향) (A Study on Heat Transfer Phenomena during Solidification in a Circular Tube Containing Phase Change Material (Effect of Inclination))

  • 송하진;김영중;오수철;임장순
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.182-192
    • /
    • 1994
  • This paper focuses on the investigation of the heat transfer phenomena that occur inside the cylindrical tube. The inclination of the tube is adopted as a principal parameter varying from vertical to horizontal. The phase change material employed in this experiment is 99 percent pure n-docosane paraffin($C_{22}$ $H_{46}$). It is found that the amount of solidified mass during a prescribed solidifying period is not sensitive to the inclination of the tube but to the local layer thickness. It is studied that the latent energy is the largest contributor to the total extracted energy. The sensible energy($E_{s1}$, $E_{s2}$, $E_{s3}$) may not be negligible at the large wall-subcooling and initial-liquid-superheating, also at the first step of solidifying.

  • PDF

스크류펌프의 유량특성과 적용 (Flowrate characteristics and application of screw pump)

  • 임종순
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.614-625
    • /
    • 2004
  • The main purpose of this study is to get flowrate coefficient 'q' and to study characteristics of flowrate of screw pump. This study is based on Muskin's formula and depends on the computer simulation. The results of study are as follows. 1. Flowrate coefficient will reduce according to increase of inclination. The larger the pitch ratio is and the smaller the diameter ratio is, the more coefficient reduces. 2. As a rule, the coefficient increases according to reduction of the diameter ratio, but the coefficient tends to reduce when the ratio is less than 0.45. So, in actual application, it is recommended that the ratio should be above 0.45. 3. If the pitch ratio increases, the coefficient increases in case of small inclination and decreases in case of large inclination. 4. The coefficient increases according to number of windings. Especially, singles winding is not used in actual application because it has too small coefficient. 5. The coefficient decreases when the influent water level falls. Flowrate is almost zero when the water level is below $40\%$ of Filling Points.

  • PDF

교류전기장이 인가된 전선을 통해 전파하는 화염에 있어서 기울어진 각도가 미치는 영향에 대한 실험적 연구 (Experimental Study on effect of inclination angle for Spreading Flame over Wire with AC Electric Fields)

  • 임승재;김민국;박정;권오붕;정석호
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2015년도 제51회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.185-188
    • /
    • 2015
  • An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.

  • PDF

시상정중면에서 하악우각부 사이의 각도와 하악과두장축의 수평경사도간의 상호관계 (INTERRELATION BETWEEN THE ANGLE FORMED BY THE MIDSAGITTAL PLANE AND THE MANDIBULAR ANGLE AND THE HORIZONTAL INCLINATION OF THE CONDYLAR LONG AXIS)

  • 오완수;최순철
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.109-116
    • /
    • 1992
  • 저자는 경북대학교 치과대학 학생중 악관절의 기능장애의 병력 및 현증이 없고 안모가 단정한 정상인 56명을 대상으로 시상정중면에서 양측의 하악우각부사이의 각도와 하악과두장축의 수평경사도를 계측하여 통계학적으로 분석한 바 다음과 같은 결과를 얻었다. 1. 시상정중면에서 하악우각부 사이의 각도는 우측이 18.50±1.48°, 좌측이 19.30±1.55°였다. 2. 하악과두장축의 수평경사도는 우측이 19.25±7.56°, 좌측이 20.27±7.05°였다. 3. 두 각도간의 관계는 우측의 경우 y=20. 31-0.0094×(r=-0 482, p<0.01), 좌측의 경우 y=20.64-0.066×(r=-0.301, p<0.05)인 것으로 나타났다(y : 하악과두장축의 수평경사도, x : 시상정중면에서 하악우각부 사이의 각도).

  • PDF

연약지반 성토시의 기울기변화를 이용한 안정관리기법에 관한 실험적 연구 (A Experimental Study on the Stability Management Method using change of Inclination for Embankment on Soft Clay)

  • 류지훈;임종철;장지건
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.898-905
    • /
    • 2005
  • The settlement of embankment on soft clay includes shear settlement due to shear deformation. Even though the consolidation settlement is not related to lateral displacement, but shear settlement makes the embankment unstable because it deforms ground and decreases the ground strength. In order to determine the shear deformation behaviour during embankment construction, 3 cases (1B, 2B, and 3B) of rapid undrained loading tests on soft clays were performed. Shear settlement is consist of elastic settlement, plastic settlement and viscous settlement. Elastic settlement isn't considered because the range is small, therefore the first is the range of plastic displacement, and the second is that of viscous displacement in the displacement-time curve for each loading stage. After determining that the change in the inclination of the viscous displacement range is larger than in the plastic displacement range after the ground failure occurs for the loading stage, the stability management methods were suggested considering that it is hard to divide the plastic displacement range and the viscous displacement range. The stability management method was based on the ratio of the plastic displacement range's inclination and the viscous displacement range's inclination. A stability management method based on the ratio of the total inclination for each loading stage compared to the whole inclination in the initial loading stage was also recommended.

  • PDF