• 제목/요약/키워드: Korean inclination

검색결과 1,590건 처리시간 0.031초

나노인덴터에 의한 ITO / Glass 박막재의 기계적 특성 (Mechanical Properties of ITO / Glass Thin Film by Indentation Method)

  • 윤한기;김도형;신도훈
    • 한국해양공학회지
    • /
    • 제21권1호
    • /
    • pp.59-63
    • /
    • 2007
  • The thin film of indium tin oxide (ITO) was prepared using the inclination opposite target type DC magnetron sputtering equipment onto the glass substrate at room temperature, using oxidized ITO with In2O3 and SnO2in a weight ratio of 9:1. The elastic modulus and hardness of the ITO thin films, prepared at different deposition conditions, were determined through anano-indentation experiment. The work pressure was varied from $2.6{\times}10-1\;to\;8.3{\times}10-1Pa$. The results show that the variation of work pressure during film deposition could vary significantly, according to the elastic modulus and hardness of the ITO thin films. It also can be seen that a minimum value exists in the film resistivity for the ITO thin films, prepared according to the variation of work pressure. However, the ITO film produced at room temperature had a microstructure in which a X ray diffraction peak is not clear, regardless of the work pressure.

기울기 센서를 이용한 타워크레인의 기울어짐 측정방안에 관한 연구 (A study on the Inclination measurement with tilt sensor on the tower crane)

  • 강신혁;공정식;권오상;장문석;신운철;이동광;장철웅;정기호;염문진;이응혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.91-92
    • /
    • 2007
  • 산업현장에서 사용되는 타워크레인의 전도 상황을 측정하기 위한 시스템은 현재 풍속계에 의존하고 있는데, 풍속계의 경우 타워크레인의 기울어짐을 정략적으로 측정할 수 없는 센서이기 때문에 정확한 상황 판단이 어렵고, 운전자나 관리자의 판단이 필요한 문제를 갖는다. 그래서 보다 정확한 정도를 측정하기 위해 타워크레인의 지브(jib) 휘어짐과 타워축의 휘어짐을 측정하여 정량적인 위험 상황을 경보 할 수 있는 전도 측정 장치가 필요하기 때문에 타워크레인의 좌/우 및 상/하 기울어짐에 대한 정량적인 측정이 가능한 기울기 센서를 이용한 센서 시스템을 구축하고, 타워크레인의 동작 위험성을 알리기 위한 경보 기법을 구축 했다.

  • PDF

스크린 메쉬형 가변전열 히트파이프에서 NCG양에 따른 작동특성 변화 (Influence of NCG Charging Mass on the Thermal Characteristics of Variable Conductance Heat Pipe with Screen Mesh Wick)

  • 서정세;박영식;강창호;정경택;박기호;이기우
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1400-1405
    • /
    • 2004
  • Experimental study is performed to investigate the effect of heat load and operating temperature on the thermal performance of a heat pipe with screen mesh wick. The heat pipe was designed in 200 screen meshes, 500mm length and 12.7mm O.D tube of copper, water as working fluid(4.8g) and nitrogen as non-condensible gas(NCG). The heat pipe used in this study has evaporator, condenser and adiabatic section, respectively. Experimental data of axial wall temperature distribution is presented for heat transport capacity, the temperature of cooling water of condenser, inclination angle, and operating temperature. For the results from this study, it is found that, for the same charging mass of working fluid, the initial operating temperature and the overall wall temperatures of heat pipe are higher for NCG charging mass of $5.0{\times}10^{-6}kg$ and $3.4{\times}10^{-6}kg$, than that of $1.0{\times}10^{-6}kg$.

  • PDF

히트파이프식 제설설비의 열응답 특성에 관한 연구 (A Study on the Thermal Response Characteristics of Snow Removing Facilities using Heat Pipe)

  • 이영수;장영석
    • 태양에너지
    • /
    • 제17권4호
    • /
    • pp.45-56
    • /
    • 1997
  • 본 연구는 제설설비에 히트파이프를 사용할때 기술적, 경제적 문제에 대해서 고찰하고, 히트파이프식의 제설구조물를 제작 설비하는 경우의 적용범위와 작동조건에 따라 전열효과를 실험적으로 검토한 것이다. 제설 제빙용으로 개발된 히트파이프식 설비는 히트파이프 배열의 피치에 관계없이 상호보완적으로 작동하였으며 제설설비를 위해 충분한 성능을 보였다. 작동액체의 충전량은 증발기의 체적을 기준으로 하여 $0.96{\sim}1.3$배인 경우가 가장 적합 하였다. 가열액체의 온도가 증가할수록 안정한 운전이 가능하였고 경사도는 4.5도에서 9도사이가 가장 양호했다. 경사가 크고 가열매체 입구온도가 증가할 때 온도진동수는 증가하고 진폭은 감소하고 열전달 효과는 크게 나타났다.

  • PDF

방위각 및 경사각을 고려한 지역별 태양광 모듈 배치안 검토 (A Study on the Photovoltaic Module Layout Considering the Azimuth and Inclination in Region)

  • 박성현;서장후
    • 설비공학논문집
    • /
    • 제24권6호
    • /
    • pp.461-466
    • /
    • 2012
  • Recently, building energy systems with solar collector and solar module have increased to improve energy problem, a heat island, a global warming and carbon dioxide emissions. In this study, value of solar radiation in areas was analyzed using TRNSYS simulation, and the optimum tilt and orientation angle for installing a photovoltaic module was examined. Average values of the weather data in the past twenty years in areas were used as input data. The results show that the tilt angle of a photovoltaic module for gaining the annual maximum solar radiation varies in different localities, and values of the annual solar radiation gained by using the variable photovoltaic module increased by 2.5 percent as compared with that gained by using the fixed photovoltaic module. When fixed photovoltaic module is installed, it should be examined the tilt and orientation angle for installing a photovoltaic module was examined.

LNG 플랜트 공정계통의 실패율이 가용도에 미치는 영향에 관한 연구 (A Study on the Availability with Failure Rate of Process for LNG Plant)

  • 강경원;윤명오;이홍철;황인주
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.358-363
    • /
    • 2012
  • The simulation investigation on the availability of LNG plant with scenario of failure events and failure rate has been carried out. This study focuses on the availability, productivity, criticality induced by failure rate of major equipment. The methodologies for simulation such as the equipment classification of LNG plant and failure type and event schematic are established. The availability and mean time to repair have second order function profile in the all cases except general equipment, but these profiles have different inclination. The production and criticality of the specified LNG plant, simulated by Monte-Carlo algorithm, is located in the range of P = 86~92% and PL = 6~13%.

진공 유리관 태양열 집열기에 열파이프의 적용을 위한 기초 연구 (A Study on Application of a Heat Pipe to an Evacuated Glass Tube Solar Collector)

  • 김철주
    • 태양에너지
    • /
    • 제12권2호
    • /
    • pp.9-17
    • /
    • 1992
  • This is an experimental work concerning about an application of a heat pipe to an evacuated-glass-tube solar collector system. A methanol heat pipe with length of 0.7 m and diameter of 8 mm was manufactured and tested to compare its performance with that of freon thermosyphon which was originally used in a solar collector system fabricated at Thermomax Co.. Then this methanol heat pipe was utilized to be one component, i.e. heat transfer element, of the present experimental model of a solar collector. This model was performed the operation test as its absorber plate was irradiated by infrared lamps. The following results were obtained. (1) The methanol heat pipe was showed a stable operation when the variation of axial heat transport was $0{\sim}40$ watts and that of inclination angle was $30{\sim}90^{\circ}$. (2) The heat transport capability of the heat pipe was proved to be higher than that of the thermosyphon, because the heat transport limitation of the latter was occured at about 30 watt. (3) The heat pipe in a solar collector was also showed good performance as it transmitted absorbed energy.

  • PDF

사면방재를 위한 무선센서 네트워크 기술연구 (Landslide Detection using Wireless Sensor Networks)

  • 김형우;이범교
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.369-372
    • /
    • 2008
  • Recently, landslides have frequently occurred on natural slopes during periods of intense rainfall. With a rapidly increasing population on or near steep terrain in Korea, landslides have become one of the most significant natural hazards. Thus, it is necessary to protect people from landslides and to minimize the damage of houses, roads and other facilities. To accomplish this goal, many landslide prediction methods have been developed in the world. In this study, a simple landslide prediction system that enables people to escape the endangered area is introduced. The system is focused to debris flows which happen frequently during periods of intense rainfall. The system is based on the wireless sensor network (WSN) that is composed of sensor nodes, gateway, and server system. Sensor nodes comprising a sensing part and a communication part are developed to detect ground movement. Sensing part is designed to measure inclination angle and acceleration accurately, and communication part is deployed with Bluetooth (IEEE 802.15.1) module to transmit the data to the gateway. To verify the feasibility of this landslide prediction system, a series of experimental studies was performed at a small-scale earth slope equipped with an artificial rainfall dropping device. It is found that sensing nodes installed at slope can detect the ground motion when the slope starts to move. It is expected that the landslide prediction system by wireless senor network can provide early warnings when landslides such as debris flow occurs.

  • PDF

이론적 해석에 의한 스크린 메쉬윅과 소결윅 히트파이프의 열수송 한계 비교 (Comparison of the Heat transport Limitations for Screen Mesh Wick and Sintered Metal Wick Heat Pipes by Theoretical Analysis)

  • 김근배;김유
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.267-274
    • /
    • 2004
  • 스크린 메쉬윅 및 소결윅 히트파이프의 열수송 한계를 예측하기 위한 이론적 해석을 수행하였다. 히트파이프의 직경은 8mm이고 작동유체는 물을 사용하였다 250메쉬 조건에서, 각각의 유효 모세관 반경(r$_{c}$ ), 기공률($\varepsilon$), 투과율(K)을 토대로 작동온도와 윅 두께 그러고 경사각에 따른 모세관압력과 열 수송 한계, 열 저항을 분석하였다. 작동온도가 높고 윅 두께가 증가할수록 모세관한계가 높아졌으며, 대체로 소결윅이 스크린적보다 높은 열수송 한계를 나타냈다. 스크린윅의 열저항이 소결윅보다 높았으며, 두 가지 모두 윅 두께가 증가함에 따라 열저항이 선형적으로 상승하였다.

The First Comprehensive Photometric Study of the Neglected Binary System V345 Cassiopeiae

  • Jeong, Min-Ji;Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.213-221
    • /
    • 2013
  • We present the first BVRI CCD photometric observations of V345 Cas made on 22 nights during the observing seasons in 2007-2008. Our light curves, resembling those of EB-type binary stars, are analyzed with the 2003 version of the Wilson-Devinney binary code. The photometric study shows that V345 Cas is a typical semi-detached binary system with the primary star being about ${\Delta}T$ = 2400 K hotter, two times more massive, but only 17% larger than the secondary star being filled with it's Roche-lobe. The orbit has a relatively large inclination of about $88^{\circ}$. A cool spot on the secondary component is modeled to explain a small light curve asymmetry. Absolute dimensions and related radiometric parameters of the eclipsing pair are calculated and their evolutionary states are discussed with the HR diagrams of mass-radius and temperature-luminosity. A period analysis of all available times of minima, including our measurements, indicates that the orbital period may vary in a cyclical way, unfortunately the secondary period for the variation can not be uniquely determined because of lack of present timing data.