Evaluation of Image Quality According to Presence or Absence of Upper limbs in Scan Field of View During CT Examinations (Including LUNG MAN) (CT 검사 시 스캔 범위 내 상지 유무에 따른 영상의 질 평가(LUNG MAN 포함))

  • Zhang, Yuying;Zheng, Haoyang;Jung, Kang-gyo;Cho, Yu-Jin;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.40 no.4
    • /
    • pp.567-573
    • /
    • 2017
  • The purpose of this study was to evaluate whether or not there was artifact when the upper limb could not be lifted to the top of the head during multi-detector computed tomography(MDCT) scans of the chest and abdomen. Contrast radiography of the human and chest phantom was performed with 128channal MDCT. Under the same conditions(120 kVp, 110 mAs, standard algorithm)both hands lifted up and put down each time in the human experiment. In the chest phantom experiment, the radiography was carried out when the upper limb phantom was adjusted at a certain distance(0, 3, 7 cm) from the chest phantom. Subsequently, the values of Noise, CT number, SNR, and CNR were measured in the field of concern. The noise value of fat, rib, and muscle increased when the arm was lifted in humans(0.79, 47.8, 27%). Furthermore, when the upper limb was lowered, the noise value of muscle and lung increased in the phantom(31.2, 9.4%). In addition, the noise value of the muscles and lung decreased by 5, 25.12% and 5.6, 15.35% as the upper limb moved about 0,3,7cm away from the chest. When the chest and abdominal radiography were performed, in the case of the presence of other parts outside the inspection area, the probability of artifact was minimal while the distance was more than 3cm away from the upper limb to the chest and abdomen.

The Role of Air-Vacuum Cushion Device in Patients with Rectal Cancer in Radiation Therapy (직장암 환자에서 방사선치료시 Air-vacuum Cushion의 유용성)

  • Kim Ki-Hwan;Cho Moon-June;Kang No-Hyun;Kim Dong-Wuk;Kim Jun-Sang;Jang Ji-Young;Kim Jae-Sung
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.287-292
    • /
    • 2001
  • Prupose : We analyzed setup errors induced by using air-vacuum cushion as immobilization device in patients with rectal cancer. Materials and methods : We had treated the twenty patients with rectal cancer by 6 MV, 10 MV X-ray from Aug. 1998 to Aug. 1999 at Chungnam National University Hospital. All patients were treated at prone position. They were separated to two groups, control group, 10 patients using styrofoam, and test group, 10 patients using styrofoam and air-vacuum cushion. We measured errors of posterior field for x, y axis and lateral field for z, y axis with simulation film and EPID image using a matching technique. Results : In control group, the mean displacement values of pelvic bone landmark for x axis and y axis were 0.02 mm. 0.78 mm, respectively and the standard deviations of systematic error were 2.13 mm, 2.40 mm, respectively and the standard deviation of random error were 1.46 mm. 1.51 mm, respectively. In test group, the mean displacement values of x axis and y axis were -0.33 mm. 0.81 mm, respectively and the standard deviations of systematic error were 1.71 mm, 3.08 mm, respectively and the standard deviations of random errors were 1.40 mm. 1.88 mm, respectively. The mean displacement values of z axis and y axis were 2.98 mm. 0.74 mm, respectively and the standard deviations of systematic error were 4.75 mm, 2.65 mm, respectively and standard deviations of random error were 2.69 mm. 1.86 mm, respectively. The statistical difference of field size by using air vacuum cushion between two groups in posterior direction and lateral direction was not shown. Conclusion : We think that use of air-vacuum cushion may not be an advantage for improving setup accuracy in rectal cancer patients.

  • PDF

In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes (토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가)

  • Minar, Maruf;Hwang, Ya-won;Choi, Seok-hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The aim of the study was to assess the in vitro effect of 808-nm InGaAs diode laser on rabbit articular chondrocyte proliferation and sulphated glycosaminoglycan (sGAG) synthesis in alginate bead. Previous studies revealed either positive or negative stimulatory effects of laser on different types of cells. A 808-nm InGaAs diode laser at 1.0W power output was used to irradiate the rabbit chondrocytes in alginate beads with energy densities of $31J/cm^2$ (G 1) and $62J/cm^2$ (G 2) corresponding to the experimental groups for 10 seconds and 20 seconds, respectively at 24, 48, 72 and 96 hours after seeding. Control group was left untreated. MTT assay was performed at 1 week and 2 weeks after the $1^{st}$ laser irradiation in alginate beads. sGAG synthesis in alginate beads at 1 week and 2 weeks were determined by DMMB assay. Histological evaluation for cellular distribution and sGAG deposition around the cells were performed by alcian blue stain. MTT assay revealed no positive stimulatory effect in cell proliferation in alginate bead. DMMB assay results showed significantly increased sGAG production in G 2 chondrocytes at 2 weeks. Image analysis of alcian blue stained slides also showed significantly higher percentage of positive alcian blue stain in G 2 chondrocytes. This result suggests that 808-nm InGaAs diode laser with 1.0 W power output although cannot stimulate cell proliferation it can increase the cell secretion activity and sGAG deposition in alginate beads.

Development of Dose Planning System for Brachytherapy with High Dose Rate Using Ir-192 Source (고선량률 강내조사선원을 이용한 근접조사선량계획전산화 개발)

  • Choi Tae Jin;Yei Ji Won;Kim Jin Hee;Kim OK;Lee Ho Joon;Han Hyun Soo
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.283-293
    • /
    • 2002
  • Purpose : A PC based brachytherapy planning system was developed to display dose distributions on simulation images by 2D isodose curve including the dose profiles, dose-volume histogram and 30 dose distributions. Materials and Methods : Brachytherapy dose planning software was developed especially for the Ir-192 source, which had been developed by KAERI as a substitute for the Co-60 source. The dose computation was achieved by searching for a pre-computed dose matrix which was tabulated as a function of radial and axial distance from a source. In the computation process, the effects of the tissue scattering correction factor and anisotropic dose distributions were included. The computed dose distributions were displayed in 2D film image including the profile dose, 3D isodose curves with wire frame forms and dosevolume histogram. Results : The brachytherapy dose plan was initiated by obtaining source positions on the principal plane of the source axis. The dose distributions in tissue were computed on a $200\times200\;(mm^2)$ plane on which the source axis was located at the center of the plane. The point doses along the longitudinal axis of the source were $4.5\~9.0\%$ smaller than those on the radial axis of the plane, due to the anisotropy created by the cylindrical shape of the source. When compared to manual calculation, the point doses showed $1\~5\%$ discrepancies from the benchmarking plan. The 2D dose distributions of different planes were matched to the same administered isodose level in order to analyze the shape of the optimized dose level. The accumulated dose-volume histogram, displayed as a function of the percentage volume of administered minimum dose level, was used to guide the volume analysis. Conclusion : This study evaluated the developed computerized dose planning system of brachytherapy. The dose distribution was displayed on the coronal, sagittal and axial planes with the dose histogram. The accumulated DVH and 3D dose distributions provided by the developed system may be useful tools for dose analysis in comparison with orthogonal dose planning.

Expression of Yippee-Like 5 (YPEL5) Gene During Activation of Human Peripheral T Lymphocytes by Immobilized Anti-CD3 (인체 말초혈액의 활성화 과정 중 yippee-like 5 (YPEL5) 유전자의 발현 양상)

  • Jun, Do-Youn;Park, Hye-Won;Kim, Young-Ho
    • Journal of Life Science
    • /
    • v.17 no.12
    • /
    • pp.1641-1648
    • /
    • 2007
  • Yippee-like proteins, which have been identified as the homolog of Drosophila yippee protein containing a zinc-finger domain, are known to be highly conserved among eukaryotes. However, their functional roles are still poorly understood. Recently we initiated ordered differential display (ODD)-polymerase chain reaction (PCR) to isolate genes of which expressions are altered following activation of human T cells. On the ODD-PCR image, one PCR-product detected in unstimulated T cells was not detectable at the time when the activated T cells traversed near $G_1/S$ boundary following activation by immobilized anti-CD3. Cloning and nucleotide sequence analysis revealed that the PCR-product was yippee-like 5 (YPEL5) gene, which was known as a human homolog of the Drosophila yippee gene. Northern blot analysis confirmed the amount of ${\sim}2.2$ kb YPEL5 mRNA expression detectable in unstimulated T cells was sustained until 1.5 hr after activation and then rapidly declined to undetectable level by 5 hr. Ectopic expression of YPEL5 gene in human cervix epitheloid carcinoma HeLa cells caused a significant reduction in cell proliferation to the level of 47% of the control. Expression of GFP-YPEL5 fusion protein in HeLa cells showed its nuclear localization. These results demonstrated that the expression level of human YPEL5 mRNA was negatively regulated in the early stage of T cell activation, and suggested that YPEL5 might exert an inhibitory effect on the cell proliferation as a nuclear protein.

Assessment of Hyperperfusion by Brain Perfusion SPECT in Transient Neurological Deterioration after Superficial Temporal Artery-Middle Cerebral Artery Anastomosis Surgery (천측두동맥-중대뇌동맥 문합술 후 발생한 일과성 신경학적 악화에서 뇌관류 SPECT를 이용한 과관류 평가)

  • Lee, Jeong-Won;Kim, Yu-Kyeong;Lee, Sang-Mi;Eo, Jae-Sun;Oh, Chang-Wan;Lee, Won-Woo;Paeng, Jin-Chul;Kim, Sang-Eun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.4
    • /
    • pp.267-274
    • /
    • 2008
  • Purpose: Transient neurological deterioration (TND) is one of the complications after extracranial-intracranial bypass surgery, and it has been assumed to be caused by postoperative transient hyperperfusion. This study was performed to evaluate the relationship between TND and preoperative and postoperative cerebral perfusion status on brain perfusion SPECT following superficial temporal artery - middle cerebral artery (STA-MCA) anastomosis surgery. Materials and Methods: A total of 60 STA-MCA anastomosis surgeries of 56 patients (mean age: $50{\pm}16$ yrs; M:F=29:27; atherosclerotic disease: 33, moyamoya disease: 27) which were done between September 2003 and July 2006 were enrolled. The resting cerebral perfusion and cerebral vascular reserve (CVR) after acetazolamide challenge were measured before and 10 days after surgery using 99mTc-ethylcysteinate dimer (ECD) SPECT. Moreover, the cerebral perfusion was measured on the third postoperative day. With the use of the statistical parametric mapping and probabilistic brain atlas, the counts for the middle cerebral artery (MCA) territory were calculated for each image, and statistical analyses were performed. Results: In 6 of 60 cases (10%), TND occurred after surgery. In all patients, the preoperative cerebral perfusion of affected MCA territory was significantly lower than that of contralateral side (p=0.002). The cerebral perfusion on the third and tenth day after surgery was significantly higher than preoperative cerebral perfusion (p=0.001, p=0.02). In TND patients, basal cerebral perfusion and CVR on preoperative SPECT were significantly lower than those of non-TND patients (p=0.01, p=0.05). Further, the increases in cerebral perfusion on the third day after surgery were significant higher than those in other patients (p=0.008). In patients with TND, the cerebral perfusion ratio of affected side to contralateral side on third postoperative day was significantly higher than that of other patients (p=0.002). However, there was no significant difference of the cerebral perfusion ratio on preoperative and tenth postoperative day between patients with TND and other patients. Conclusion: In patients with TND, relative and moderate hyperperfusion was observed in affected side after bypass surgery. These finding may help to understand the pathophysiology of TND.

Precise, Real-time Measurement of the Fresh Weight of Lettuce with Growth Stage in a Plant Factory using a Nutrient Film Technique (NFT 수경재배 방식의 식물공장에서 생육단계별 실시간 작물 생체중 정밀 측정 방법)

  • Kim, Ji-Soo;Kang, Woo Hyun;Ahn, Tae In;Shin, Jong Hwa;Son, Jung Eek
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.77-83
    • /
    • 2016
  • The measurement of total fresh weight of plants provides an essential indicator of crop growth for monitoring production. To measure fresh weight without damaging the vegetation, image-based methods have been developed, but they have limitations. In addition, the total plant fresh weight is difficult to measure directly in hydroponic cultivation systems because of the amount of nutrient solution. This study aimed to develop a real-time, precise method to measure the total fresh weight of Romaine lettuce (Lactuca sativa L. cv. Asia Heuk Romaine) with growth stage in a plant factory using a nutrient film technique. The total weight of the channel, amount of residual nutrient solution in the channel, and fresh shoot and root weights of the plants were measured every 7 days after transplanting. The initial weight of the channel during nutrient solution supply (Wi) and its weight change per second just after the nutrient solution supply stopped were also measured. When no more draining occurred, the final weight of the channel (Ws) and the amount of residual nutrient solution in the channel were measured. The time constant (${\tau}$) was calculated by considering the transient values of Wi and Ws. The relationship of Wi, Ws, ${\tau}$, and fresh weight was quantitatively analyzed. After the nutrient solution supply stopped, the change in the channel weight exponentially decreased. The nutrient solution in the channel slowly drained as the root weight in the channel increased. Large differences were observed between the actual fresh weight of the plant and the predicted value because the channel included residual nutrient solution. These differences were difficult to predict with growth stage but a model with the time constant showed the highest accuracy. The real-time fresh weight could be calculated from Wi, Ws, and ${\tau}$ with growth stage.

EFFECT OF ROTATIONAL SPEED OF PROTAPERTM ROTARY FILE ON THE CHANCE OF ROOT CANAL CONFIGURATION (ProTaperTM로 근관성형시 회전 속도 변화가 근관형태에 미치는 영향)

  • Seo, Min-Chul;Jeon, Yoon-Jeong;Kang, In-Chol;Kim, Dong-Jun;Hwang, Yun-Chan;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.179-185
    • /
    • 2006
  • This study was conducted to evaluate canal configuration after shaping by $ProTaper^{TM}$ with various rotational speed in J-shaped simulated resin canals. Forty simulated root canals were divided into 4 groups, and instrumented using by $ProTaper^{TM}$ at the rotational speed of 250, 300, 350 and 400 rpm. Pre-instrumented and post-instrumented images were taken by a scanner and those were superimposed. Outer canal width, inner canal width, total canal width, and amount of transportation from original axis were measured at 1, 2, 3, 4, 5, 6, 7 and 8 mm from apex. Instrumentation time, instrument deformation and fracture were recorded. Data were analyzed by means of one-way ANOVA followed by Scheffe's test. The results were as follows 1. Regardless of rotational speed, at the $1{\sim}2mm$ from the apex, axis of canal was transported to outer side of a curvature, and at 3~6 mm from the apex, to inner side of a curvature. Amounts of transportation from original axis were not sienifcantly different among experimental groups except at 5 and 6 mm from the apex. 2. Instrumentation time of 350 and 400 rpm was significantly less than that of 250 and 300 rpm (p<0.01). In conclusion the rotational speed of $ProTaper^{TM}$ files in the range of $250{\sim}400rpm$ does not affect the change of canal configuration, and high rotational speed reduces the instrumentation time. However appearance of separation and distortion of Ni-Ti rotary files can occur in high rotational speed.

Application of Chlorophyll Fluorescence Parameters for the Detection of Water Stress Ranges in Grafted Watermelon Seedlings (수박접목묘의 건조스트레스 범위 탐지를 위한 엽록소형광 지수의 적용)

  • Shin, Yu Kyeong;Kim, Yong Hyeon;Lee, Jun Gu
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.461-470
    • /
    • 2019
  • This study was carried out to quantify the drought stress in grafted watermelon seedlings non-destructively by using chlorophyll fluorescence (CF) imaging technique rather than the visual judgment. Six-day old watermelon seedlings were grown under uniform irrigation for 3 days, and then given drought stress. Afterward, the sensor for the measurement of water content in plug tray cell unit was used to classify the drought-stress level into nine groups from D1 (53.0%, sufficient moisture state) to D9 (15.7%, extremely dry stress), and the 16 CF parameters were measured. In addition, re-irrigation was performed on the drought stressed seedlings(D5 - D9) to determine the growth and photosynthesis recovery level, which was not confirmed by visual judgment. The kinetic curve patterns of CF in three different drought stressed seedling groups were found to be different for the early detection of drought stress. All the 16 CF parameters decreased continuously with exposure to drought stress and drastically decreased from D5 (32.1%) where the visual judgment was possible. The fluorescence decline ratio (Rfd_Lss) started to decrease from the initial drought stress level (D5 - D6), and the Maximum PSII quantum yield (Fv/Fm) was significantly decreased in the later extreme drought stress range (D7 - D9) by re-irrigation recovery test. Thus, Rfd_Lss and Fv/Fm parameters were finally selected as potent indicators of growth and photosynthesis recovery in the initial and later stages of drought stress. Also, to the differences in the numerical values of the individual chlorophyll fluorescence parameters, the drought stress level was intuitively confirmed through the image. These results indicate that Rfd and Fv/Fm can be considered as potential CF parameters for the detection of low and extremely high drought stress, respectively. Furthermore, Fv/Fm can be considered as the best CF parameters for recovery at re-irrigation.

Time-Lapse Crosswell Seismic Study to Evaluate the Underground Cavity Filling (지하공동 충전효과 평가를 위한 시차 공대공 탄성파 토모그래피 연구)

  • Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.1 no.1
    • /
    • pp.25-30
    • /
    • 1998
  • Time-lapse crosswell seismic data, recorded before and after the cavity filling, showed that the filling increased the velocity at a known cavity zone in an old mine site in Inchon area. The seismic response depicted on the tomogram and in conjunction with the geologic data from drillings imply that the size of the cavity may be either small or filled by debris. In this study, I attempted to evaluate the filling effect by analyzing velocity measured from the time-lapse tomograms. The data acquired by a downhole airgun and 24-channel hydrophone system revealed that there exists measurable amounts of source statics. I presented a methodology to estimate the source statics. The procedure for this method is: 1) examine the source firing-time for each source, and remove the effect of irregular firing time, and 2) estimate the residual statics caused by inaccurate source positioning. This proposed multi-step inversion may reduce high frequency numerical noise and enhance the resolution at the zone of interest. The multi-step inversion with different starting models successfully shows the subtle velocity changes at the small cavity zone. The inversion procedure is: 1) conduct an inversion using regular sized cells, and generate an image of gross velocity structure by applying a 2-D median filter on the resulting tomogram, and 2) construct the starting velocity model by modifying the final velocity model from the first phase. The model was modified so that the zone of interest consists of small-sized grids. The final velocity model developed from the baseline survey was as a starting velocity model on the monitor inversion. Since we expected a velocity change only in the cavity zone, in the monitor inversion, we can significantly reduce the number of model parameters by fixing the model out-side the cavity zone equal to the baseline model.