• Title/Summary/Keyword: Korean case drop

Search Result 552, Processing Time 0.033 seconds

A Study on Flow Analysis at Ball Valve according to Opening and Shutting Angle (개폐 각도에 따른 볼 밸브에서의 유동 해석에 관한 연구)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.2
    • /
    • pp.46-51
    • /
    • 2011
  • This study result is obtained by flow analysis according to opening and shutting angle of ball valve. As opening and shutting angle becomes larger, vortex flow becomes smaller and flow rate becomes increased. And the pressure drop is shown to be smaller at the inlet and outlet of ball. As this angle becomes larger, mass flow rate becomes increased. Its rate becomes increased abruptly in case of opening and shutting angle at more than $60^{\circ}$.This analysis result can be applied usefully with no leak at pipe system field by the optimum control of mass flow rate according to opening and shutting of ball valve.

Finite Element Analysis of ICFPD Method for the Defect Detection of Railway Axle (철도차량 차축 결함에 대한 집중 유도 전위차법 탐상의 유한요소 해석)

  • Goo B.C.;Lim C.H.;Kwon S.J.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.24-27
    • /
    • 2005
  • The NDT(Non-Destructive Testing) is valid fur the defect detection of rolling stocks because it can be used to detect defects in invisible places. For example, in case of wheelsets fatigue cracks are initiated in the wheel seat that suffers from fretting fatigue damage. But the conventional ICFPD method can not be applied to detect such cracks in press-fit area of the axle by some technical problems. In this study, we introduced a new ICFPD (Induced Current Focusing Potential Drop) method that can be applied in press-fit area of the axle. And we performed the finite element analysis of the new ICFPD method using measured electromagnetic properties of the wheel and axle. It seems that our approach is very useful f3r the detection of defects in invisible places.

  • PDF

A Case Report on the Idiopathic Conjunctivitis Treated by CHUNA Manual Therapy (경추 추나를 이용하여 치료한 특발성 결막염 치험 1례)

  • Choi, You-Seok;Kim, Dae-Pil;Park, Young-Hoi;Keum, Dong-Ho;Kang, Ji-Hun
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.5 no.1
    • /
    • pp.109-116
    • /
    • 2004
  • Objective : There is no case report on the Idiopathic Conjunctive treated by CHUNA manual therapy in oriental medicine. We experienced a patient with the Idiopathic Conhunctivitis improved by CHUNA manual therapy in X-ray imagine and visual analogue scale(VAS), and we report It. Methods : During the patient with the Idiopathic Conjunctivitis was treated CHUNA manual therapy, we examined cervial X-ray and evaluated the patient's symptoms by VAS and counting eye drop. And we observed whether the change exist or not in X-ray. Result : Symptoms(Red eye, eye xerosis) was improved significally, and the X -ray image was improved. Conclusion : Conjunctivitis was generally treated steroid eye drop and conservative treatment. But CHUNA manual therapy may be more effective in the Idiopathic Conjunctivitis, if more clinical studies and researchs are accomplished.

  • PDF

Analysis on Thermal Environment of Marathon Course in 2011 Daegu World Championship in Athletics (대구 세계육상선수권대회 마라톤 구간의 열환경변화분석)

  • Baek, Sang-Hun;Oh, Sang-Hak;Jung, Yong-Hun;Jung, Eung-Ho
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.881-890
    • /
    • 2011
  • In this study, thermal environment changes for a marathon course of IAAF World Championship, Daegu 2011 were modeled to provide improvements of thermal environment, so that runners could have the maximum condition and citizens pleasant streets. The three biggest size of intersections were selected for the study. Envi-met, 3G microclimate model, were used for a thermal environment analysis and three different cases - present status, planting roadside tree scenario, and roof-garden scenario - were compared. The followings are the results of the study. 1. The highest thermal distribution were shown at 1 p.m., but there was no significant difference between a thermal distribution at 1 p.m. and that at 5 p.m. since a heat flux from buildings affects thermal distributions rather than insolation does. 2. Tree planting or adding environmental friendly factors might lead a temperature drop effect, but the effect was not significant for areas covered with impermeability packing materials such as concrete or asphalt (especally, for Site case 2) 3. The combination of tree planting and adding environmental friendly factors also brought a temperature drop effect (Site 1 and 2) and this case showed even better result if green spaces (especially, parks) were closed.

Heat Transfer Characteristics of Fin-Tube Heat Exchanger using Two-Port Tube of Small Inner Diameter by Mechanical Expansion (연결세경관을 이용한 휜관형 열교환기의 기계확관에 의한 전열특성)

  • Lee, Sangmu;Park, Byung-Duck
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.11
    • /
    • pp.428-433
    • /
    • 2016
  • The fin and tube heat exchanger using a two-port tube has in air-conditioner heat exchanger because heat transfer performance. This study investigates the feasibility of a fin and tube heat exchanger using two-port copper tube by mechanical expansion. The optimum size of the tube-expanding bullet for the heat exchanger using two-port tube was through numerical calculation. The heat exchanger using a two-port tube was fabricated by mechanical expansion, and the heat exchanger performance was evaluated condensation and evaporation experiments. Compared to the heat exchanger of a conventional circular tube, the pressure drop per unit length of the heat exchanger with a two-port tube decreased. Compared to the heat exchanger using a conventional circular tube, the overall heat transfer coefficient of heat exchanger with a two-port tube increased up to 13% in the case of condensation, and up to 25% in the case of evaporation. The two-port tube heat exchanger outperforms conventional heat exchanger for air conditioner with a inner grooved circular tube.

The Case Report of Common Peroneal Nerve Palsy Treated with Musculoskeletal Ultrasound-guided Acupotomy Therapy (총비골신경마비의 근골격계 초음파를 이용한 침도치료 임상증례)

  • Kim, Sung-Ha;Park, Man-Young;Lee, Sang-Mi;Jung, Ho-Hyun;Park, Se-Woon;Park, Ok-Ju;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.29 no.5
    • /
    • pp.177-185
    • /
    • 2012
  • Objectives : The objective of this case report was to observe the effect of musculoskeletal ultrasound-guided acupotomy therapy on common peroneal nerve palsy. Methods : From June, 2010 to September, 2012, 3 patients clinically diagnosed as common peroneal nerve palsy were treated with general oriental medicine therapy (acupuncture, pharmacopuncture, moxibustion, cupping, physical therapy, herbal medication) and acupotomy. Results : The foot drop of the patients was remarkably improved. Conclusions : This study demonstrates that oriental medical treatment with acuputomy therapy hasnotable effect in improving symptoms of common peroneal nerve palsy. As though we had not widly experienced in this treatment, more research is needed.

Pressure and Flow Distribution in the Inlet Plenum of a Pebble Bed Modular Reactor (PBMR)

  • Ahmad, Imteyaz;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.244-249
    • /
    • 2005
  • Flow distribution and pressure drop analysis for an inlet plenum of a Pebble Bed Modular Reactor (PBMR) have been performed using Computational Fluid Dynamics. Three-dimensional Navier-Stokes equations have been solved in conjunction with $k-{\epsilon}$ model as a turbulence closure. Non-uniformity in flow distribution is assessed for the reference case and parametric studies have been performed for rising channels diameter, Reynolds number and angle between the inlet ports. Also, two different shapes of the inlet plenum namely, rectangular shape and oval shape, have been analysed. The relative flow mal-distribution parameter shows that the flow distribution in the rising channels for the reference case is strongly non-uniform. As the rising channels diameter decreases, the uniformity in the flow distribution as well as the pressure drop inside the inlet plenum increases. Reynolds number is found to have no effect on the flow distribution in the rising channels for both the shapes of the inlet plenum. The increase in angle between the inlet ports makes the flow distribution in the rising channels more uniform.

  • PDF

Case Study of Oriental Medicine Treatment with Acupotomy Therapy of the Peroneal Nerve Palsy through Ultrasound Case Report (근골격계 초음파를 이용한 침도침술의 비골신경 마비 증례 보고)

  • Kim, Sung-Ha;Park, Man-Young;Lee, Sang-Mi;Lee, Sang-Kwan;Lim, Jin-Young;Kim, Sung-Chul
    • Journal of Pharmacopuncture
    • /
    • v.14 no.1
    • /
    • pp.87-95
    • /
    • 2011
  • Purpose : In order to estimate clinical effects of Oriental Medicine Treatment with acupotomy therapy of Peroneal nerve Palsy. Methods : From 10th June, 2010 to 19th June, 2010, 1 female patient diagnosed as Peroneal nerve Palsy(clinical diagnosed) was treated with general oriental medicine therapy (acupuncture, pharmacopuncture, moxibustion, cupping, physical therapy, herbal medication) and acupotomy. Results : The patient's left foot drop was remarkably improved. Conclusions : This study demonstrates that oriental medical treatment with acuputomy therapy has notable effect in improving symptoms of peroneal nerve palsy. as though we had not wide experience in this treatment, more research is needed.

Design of the miniature Joule-Thomson refrigerator as a cryoprobe (저온 수술 프로브용 소형 Joule-Thomson 냉동기의 설계)

  • Hwang, Gyu-Wan;Jeong, Sang-Kwon;In, Se-Hwan
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.1
    • /
    • pp.86-90
    • /
    • 2007
  • The cryoprobe used in cryosurgery should be fabricated in milimeter-order size for its practical usage. In general a miniature J-T(Joule-Thomson) refrigerator is applied to a cryoprobe. In case of the miniature J-T refrigerator, the mass flow rate of working fluid is small due to considerable friction in a minute flow path. For that reason, the miniature J-T refrigerator has a limited cooling power. To obtain the large cooling power from the J-T refrigerator, the refrigerator should have large mass flow rate and effective J-T temperature drop. These quantities are closely related to the geometry of the heat exchanger and the expansion nozzle in a cryoprobe, and are contradictory. The large mass flow rate leads to the small J-T temperature drop and vice versa in the miniature J-T refrigerator. Therefore, the optimal design of a cryoprobe to achieve maximum cooling power at fixed tube size and fixed operating temperature is required. This paper presents the design procedure of such case.

Compensate Voltage Drop for Autotransformer-Fed AC Electric Railroad System with Single-Phase STATCOM (STATCOM을 이용한 교류 전기철도 급전시스템의 전압강하 보상)

  • 정현수;이승혁;김진오
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.5
    • /
    • pp.53-60
    • /
    • 2002
  • This paper presents exact autotransformer-fed AC electric railroad system modeling using constant current mode, and single-phase STATCOM(Static Synchronous Compensator) which has an effect on electric railroad system. An AC electric railroad is rapidly changing single-phase feeding electric power. To avoid voltage fluctuation under single phase loads, electric power should be received from a large source. The system modeling theory is based on the solution of algebraic. The AC electric railroad load model is nonlinear. Therefore this paper is considered nonlinear load using PSCAD/EMTDC. And the proposed modeling method is considered the line self-impedances and mutual-impedances that techniques for the AC electric railroad system modeling analysis, and that single-phase STATCOM can reliably compensate the voltage drop. In the case study, the allowance range of feeding voltage is 22.5∼27.5 kV, AT-fed AC electric railroad system circuit is analyzed by loop equation both normal and extension modes. The simulation objectives are to calculate the catenary and rail voltages with respect to ground, as the train moves along a section of line between two adjacent ATs. The results show that single-phase STATCOM can reduce the voltage drop in the feeding circuit and improve the power quality at AC electric railroad system by compensating the reactive power.