• Title/Summary/Keyword: Korean Medicine Information Center

Search Result 1,475, Processing Time 0.027 seconds

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

Gender Differences in Pain in Cancer Patients (성별에 따른 암환자의 통증 차이)

  • Kim, Hyun-Sook;Lee, So-Woo;Yun, Young-Ho;Yu, Su-Jeong;Heo, Dae-Seog
    • Journal of Hospice and Palliative Care
    • /
    • v.4 no.1
    • /
    • pp.14-25
    • /
    • 2001
  • Purpose : To determine whether there exist gender differences in pain in Korean cancer patients and whether the depression and performance that are often expressed differently between men and women with cancer interact with pain. Method : The results of survey were collected from 140 in- and out-patients (78 male and 62 female) who had cancer treatment at one of the university hospital in Seoul for four months from February of 1999. The severity and interference of pain were examined with the self-reported survey based on Korean version of Brief Pain Inventory (BPI-K). Demographic and clinical information for all patient were compiled by reviewing their medical records, and the level of depression was examined with the Korean version of Beck Depression Inventory (BDI-K). Usual statistical methods, e.g., frequences, means and SDs were used to characterize the sample. The chi-square tests for categorical data and t-test for numerical data were used for group comparison. And the correlation between variables were performed using Pearson correlation coefficient. Resuts : 1) The mean scores of the worst pain for last 24-hours measured with the pain severity of BPI-K were 5.77 in male and 6.45 in female. The pain interference of BPI-K in men was in the order of mood (5.49), enjoy (5.36), and work (5.00), and in women were work (7.48), enjoy (7.16), and mood (6.53). 2) In pain severity, significant difference was found between men and women in the average pain for last 24-hours (t=-2.130, P=.035). In pain interference, significant difference was found between men and women in activity (t=-2.450, P=.015), mood (t=-2,321, P=.022), walk (t=-2.762, P=.007), work (t=-4.946, P=.000), relate (t=-2.595, P=.010), sleep (t=-2.071, P=.040), enjoy (t=-3.198, P=.001). 3) It was found that the items of pain and depression are significantly correlated in men but not in women. Men also exhibited higher correlation in the items of pain and performance status than women. Conclusions : Women report significantly greater average pain for last 24-hours and for all items of pain interference than men. Pain and depression are significantly correlated in men. The results of this study suggest that gender differences in pain should be considered for planning effective pain management program.

  • PDF

Age-related Changes in Luteinizing Hormone and Testosterone Levels in Korean Men (한국 남성의 혈중 Luteinizing Hormone과 Testosterone 수준의 연령-관련 변화)

  • Lee, Sung-Ho;Ahn, Ryun-Sup;Kwon, Hyuk-Bang
    • Development and Reproduction
    • /
    • v.12 no.1
    • /
    • pp.57-66
    • /
    • 2008
  • Changes in luteinizing hormone (LH), serum testosterone (T), and salivary T levels with age were examined in Korean men. Serum was obtained from 167 Korean men of different ages ($20{\sim}69\;y$), and the serum LH and T levels were measured. Saliva samples were also obtained, and the salivary T level was determined. The LH levels did not change considerably until 40 y of age (20s, $2.5{\pm}1.0$; 30s, $2.7{\pm}1.5$; and 40s, $2.5{\pm}1.8\;mIU/mL$) but increased significantly around 50 y (50s, $3.7{\pm}1.8$ and 60s, $3.1{\pm}1.7\;mIU/mL$). Further, the serum T levels also did not change until 40 y of age (20s, $5.3{\pm}2.6$, 30s, $4.4{\pm}1.4$, 40s, $4.1{\pm}1.5\;ng/mL$) but decreased significantly at 50 y (50s, $3.4{\pm}1.5$; 60s, $2.6{\pm}0.8\;ng/mL$). The salivary T levels also showed small changes until the age of 40 y ($20s{\sim}40s$, $0.11{\pm}0.015\;ng/mL$) but decreased significantly at 50 y ($0.08{\pm}0.03\;ng/mL$). Thus, the relative ratio of salivary T to serum T levels did not change significantly in all the ages examined ($2.4{\pm}0.9%$). Linear regression analysis predicted that the LH levels increased 1.5%/y while the serum and salivary T levels decreased 1%/y and 0.8%/y, respectively. The serum T/LH ratio did not change considerably until the age of 40 y ($20s{\sim}40s$, $2.27{\pm}0.14$) but decreased significantly ($1.2{\pm}1.0$) at 50 y. Age-related changes in the salivary T/LH ratio were very similar to those in the serum T/LH ratio. These results demonstrated that LH and T levels in serum or saliva did not change considerably until 40 y of age; instead, in Korean men, from 50 y of age, the LH level increased, while the T level decreased. This suggests that primary testicular failure that occurred due to aging (approximately 50 y) and caused this phenomenon. The present study also shows that the salivary T level can be an indicator of the free T level in serum although the salivary T level correlates weakly with the total T level in serum (r=0.53). Thus, information regarding salivary T levels may be useful for studying the age-related changes occurring in male testicular physiology.

  • PDF

Safety and Reactogenicity of the Inactivated Poliomyelitis Vaccine (PoliorixTM) in Korea (2006-2012) (우리나라 영아에서 주사용 소아마비 백신(PoliorixTM)의 안전성 및 이상반응에 대한 연구)

  • Sin, Jong Beom;Park, Moon Sung;Ma, Sang Hyuk;Choi, Young Youn;Shin, Son Moon;Kim, Won Duck;Kuriyakose, Sherine;Ulianov, Liliana;Hardt, Karin
    • Pediatric Infection and Vaccine
    • /
    • v.20 no.3
    • /
    • pp.139-146
    • /
    • 2013
  • Objective: As per the requirement of Korean Food and Drug Administration, this post-marketing surveillance was conducted in Korea to evaluate the safety and reactogenicity of Poliorix$^{TM}$ following its introduction in 2006. Methods: In this open, multicenter study, the vaccine was administered as per the current practice of Korean doctors and in reference to the guidebook by the Korean Pediatric Society and as indicated in the Korean label which was as follows - for primary vaccination three doses were given to infants at ages 2, 4 and 6 months whereas, for the booster dose a single dose was given to children aged 4-6 years. Safety data during this six year surveillance was collected using diary cards which were distributed to the parents to record adverse events. Results: A total of 639 subjects were enrolled into the study. Of these, 617 subjects and 22 subjects received the vaccine as a primary and booster dose, respectively. At least one unsolicited symptom was reported in 11.4% (73/639) of the subjects during the 7-day follow-up period; upper respiratory tract infection (2.5%;16/639) was the most frequently reported unsolicited symptom. One subject reported at least one unsolicited symptom (gastroenteritis) of grade 3 intensity within the 31-day post-vaccination period. Approximately 1.7% (11/639) of subjects reported 13 serious adverse events (SAEs). All SAEs were resolved by the end of the study. Conclusion: In Korea, primary and booster vaccination with Poliorix$^{TM}$ was well-tolerated in healthy subjects when administered according to the prescribing information as part of routine clinical practice.

  • PDF

Development and relative validity of semi-quantitative food frequency questionnaire for Korean adults (한국인을 위한 반정량 식품섭취빈도 조사지의 개발 및 타당도 연구)

  • Kim, Sohye;Lee, Jung Sug;Hong, Kyung Hee;Yeom, Hye Sun;Nam, Yeon Seo;Kim, Ju Young;Park, Yoo Kyung
    • Journal of Nutrition and Health
    • /
    • v.51 no.1
    • /
    • pp.103-119
    • /
    • 2018
  • Purpose: This study was implemented to develop and validate the semi-quantitative food frequency questionnaire (SQ-FFQ) to assess energy, carbohydrates, fat, protein, minerals, and vitamins as well as fatty acids and alcohol in Korean adults. Methods: The SQ-FFQ consisted of 88 food items, and 12 food groups were selected based on information of frequently consumed foods from the Korean Health and Nutrition Examination survey. Each portion size was categorized as one of three amounts: small (0.5 times), medium (1 time), and large (1.5 times). A total of 111 subjects finished 3-day diet records and the SQ-FFQ. The relative validity of SQ-FFQ was assessed by comparison with the 3-day diet records. Results: The mean nutrient intakes obtained from the SQ-FFQ were estimated to be greater than those of the two 3-day dietary records. Spearman's correlation coefficient between the two methods was the highest for energy (r = 0.583; p < 0.001) and lowest for saturated fatty acid (r = 0.121). Correlation coefficients were energy (r = 0.583; p < 0.001), carbohydrates (r = 0.500; p < 0.001), protein (r = 0.466; p < 0.001), fat (r = 0.411; p < 0.001), dietary fiber (r = 0.467; p < 0.001), alcohol (r = 0.527; p < 0.001), calcium (r = 0.409; p < 0.001), phosphorus (r = 0.499; p < 0.001), potassium (r = 0.418; p < 0.001), magnesium (r = 0.427; p < 0.001), and zinc (r = 0.464; p < 0.001), respectively, for all subjects. Conclusion: The developed SQ-FFQ in this study seems to be useful for estimating nutritional status, particularly energy, carbohydrates, protein, fat, dietary fiber, alcohol, calcium, phosphorus, potassium, magnesium, and zinc of Korean adults.

호스피스 전달체계 모형

  • Choe, Hwa-Suk
    • Korean Journal of Hospice Care
    • /
    • v.1 no.1
    • /
    • pp.46-69
    • /
    • 2001
  • Hospice Care is the best way to care for terminally ill patients and their family members. However most of them can not receive the appropriate hospice service because the Korean health delivery system is mainly be focussed on acutly ill patients. This study was carried out to clarify the situation of hospice in Korea and to develop a hospice care delivery system model which is appropriate in the Korean context. The theoretical framework of this study that hospice care delivery system is composed of hospice resources with personnel, facilities, etc., government and non-government hospice organization, hospice finances, hospice management and hospice delivery, was taken from the Health Delivery System of WHO(1984). Data was obtained through data analysis of litreature, interview, questionairs, visiting and Delphi Technique, from October 1998 to April 1999 involving 56 hospices, 1 hospice research center, 3 non-government hospice organizations, 20 experts who have had hospice experience for more than 3 years(mean is 9 years and 5 months) and officials or members of 3 non-government hospice organizations. There are 61 hospices in Korea. Even though hospice personnel have tried to study and to provide qualified hospice serices, there is nor any formal hospice linkage or network in Korea. This is the result of this survey made to clarify the situation of Korean hospice. Results of the study by Delphi Technique were as follows: 1.Hospice Resources: Key hospice personnel were found to be hospice coordinator, doctor, nurse, clergy, social worker, volunteers. Necessary qualifications for all personnel was that they conditions were resulted as have good health, receive hospice education and have communication skills. Education for hospice personnel is divided into (i)basic training and (ii)special education, e.g. palliative medicine course for hospice specialist or palliative care course in master degree for hospice nurse specialist. Hospice facilities could be developed by adding a living room, a space for family members, a prayer room, a church, an interview room, a kitchen, a dining room, a bath facility, a hall for music, art or work therapy, volunteers' room, garden, etc. to hospital facilities. 2.Hospice Organization: Whilst there are three non-government hospice organizations active at present, in the near future an hospice officer in the Health&Welfare Ministry plus a government Hospice body are necessary. However a non-government council to further integrate hospice development is also strongly recommended. 3.Hospice Finances: A New insurance standards, I.e. the charge for hospice care services, public information and tax reduction for donations were found suggested as methods to rise the hospice budget. 4.Hospice Management: Two divisions of hospice management/care were considered to be necessary in future. The role of the hospice officer in the Health & Welfare Ministry would be quality control of hospice teams and facilities involved/associated with hospice insurance standards. New non-government integrating councils role supporting the development of hospice care, not insurance covered. 5.Hospice delivery: Linkage&networking between hospice facilities and first, second, third level medical institutions are needed in order to provide varied and continous hospice care. Hospice Acts need to be established within the limits of medical law with regards to standards for professional staff members, educational programs, etc. The results of this study could be utilizes towards the development to two hospice care delivery system models, A and B. Model A is based on the hospital, especially the hospice unit, because in this setting is more easily available the new medical insurance for hospice care. Therefore a hospice team is organized in the hospital and may operate in the hospice unit and in the home hospice care service. After Model A is set up and operating, Model B will be the next stage, in which medical insurance cover will be extended to home hospice care service. This model(B) is also based on the hospital, but the focus of the hospital hospice unit will be moved to home hospice care which is connected by local physicians, national public health centers, community parties as like churches or volunteer groups. Model B will contribute to the care of terminally ill patients and their family members and also assist hospital administrators in cost-effectiveness.

  • PDF

Differences in Patients' and Family Caregivers' Ratings of Cancer Pain (암환자와 그 가족간호자가 지각하는 환자의 통증강도 차이)

  • Kim, Hyun-Sook;Yu, Su-Jeong;Kwon, Shin-Young;Park, Yeon-Hee
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.1
    • /
    • pp.42-50
    • /
    • 2008
  • Purpose: Undertreatment of canter pain, especially due to the differences in the perception of pain between the patients and caregivers, is a well recognized problem. The purpose of this study were to determine if there exist differences in communication about pain intensity scores between patients and their family caregivers in Korea. Methods: A total of 127 patient-family caregiver dyads who have experienced canter pain participated in this study at a hospital in Seoul for six months. The data were obtained by fare to face interview with a structured questionnaire based on Brief Pain Inventory-Korean version and other previous researches. The clinical information for all patients was compiled by reviewing their medical records. Results: Patients' 'worst-pain for 24-hour' and 'right-now-pain' scores estimated by family caregivers were significantly higher than those by patient themselves. The degree of agreement between patients and family caregivers in the estimate of patients' 'worst-pain for 24-hour' intensity categories was 78.7% for 'severe pain', 40% for 'no pain', 27.5% for 'mild pain' and 22.9% for 'moderate pain'. In case of 'right-now-pain' intensity categories, the agreement was 50% for 'severe pain', 47.2% for mild pain, 46.3% for 'no pain', and 26.3% for 'moderate pain'. Conclusion: This study demonstrates that the degree of agreement between patients and family caregivers in the estimate of patients 'pain intensity categories was less than 50% except for 'severe pain'. The results indicate that Korean family caregivers tend to overestimate the canter pain intensity of their caring patients, especially, when a lancer patient has 'moderate' or 'mild pain'. Health Providers are advised to educate patient-family caregiver dyads to use a pain measurement scale to promote their agreement in pain Intensity stores. Further analyses and studies are needed to identify the factors and differences that influence their communication about pain intensity scores between patients and their family caregivers.

  • PDF

A Research on Service and Awareness of Dental Coordinators by Manpower at Dental Care Service Institutions - Centering on Manpower Other than Dentists (치과코디네이터 업무 및 인식에 관한 조사연구 - 치과의사를 제외한 기타 인력을 중심으로)

  • Choi, Boo-Keun;Han, Su-Jin;Kwon, Soon-Bok;Jung, Jae-Yeon;Cho, Myung-Sook;Hwang, Yoon-Sook
    • Journal of Korean society of Dental Hygiene
    • /
    • v.6 no.4
    • /
    • pp.437-453
    • /
    • 2006
  • To analyze dental hygienists and other manpower at dental care service institutions where a dental coordinator was working among about 200 dental care service institutions in Seoul, Gyeonggi Province, and Incheon as of June 2005 for contents of training for dental coordinators, opinions of qualification of dental coordinators, present and future services provided by dental coordinators, and awareness of dental coordinators and to provide basic data about future services, roles, and cultivation of dental coordinators, a survey was conducted and 216 copies returned were analyzed, obtaining the following results. 1. 83.8 percent needed an educational program for dental coordinators as an educational content; 41.7% had awareness of the educational content; and 83.8 percent insisted that over the intermediate level of curricula should be taken. Dental coordinator cultivation institutions identified included the institution under the control of the Korean Dental Hygienists Association and the education center for the department of dental hygiene; 76.9% insisted that an appropriate qualifying examination should be necessary. They suggested the central government department and the local government as a certification institution; 39.4% insisted that financial support for the education should be provided by financing education alone. Only 28.7% experienced dental coordinator education and 73.1% hoped to serve as a dental coordinator. They were found to expect a rise in payment(64.4%) and in the title(46.8%) after completion of the educational program. 2. 66.2% saw a dental hygienist as the most appropriate for a dental coordinator; clinical career (39.4%) and practical capacity(29.2%) were suggested as requirements for a dental coordinator; and a period of over three years(47.2%) was suggested for appropriate dental career. 3. Dental coordinators' present services included 'reservation management' for customer management, 'staff service training' for organization management, 'understanding of customer reception attitudes and actions' for self-management, 'hospital information management' for hospital marketing, 'acceptance' for hospital affairs management, and 'hospital environment management' for hospital facilities management; their future services included 'acquisition of ability to use a foreign language' for self-management, followed by 'staff service training' for organization management, 'training and counseling' for customer management, 'acquisition of counseling capacity' for self-management, 'complaining customer reception' for customer management, and 'marketing strategy implementation' for hospital marketing. 4. After comparing dental hygienists and other manpower in terms of dental coordinators' future services, dental hygienists showed interest in 'acquisition of ability to use a foreign language,' 'staff service training,' 'complaining customer reception,' and 'acquisition of counseling capacity' while other manpower showed interest in 'acquisition of ability to use a foreign language,' 'document data management,' 'acquisition of basic service manner,' 'acquisition of counseling capacity,' 'manpower management,' 'establishment and evaluation of a marketing strategy,' and 'education and counseling.' 5. As for awareness of dental coordinators, they were thought of as helpful in improving image of a dental clinic; it was found that continuous training should be necessary to develop dental coordinators' capacity; dental coordinators' services should be important and contribute to patients' qualitative satisfaction.

  • PDF

Evaluation of Temperature and Humidity of a Thermo-Hygrostat of PET/CT Equipment using a Temperature and Humidity Sensor(BME 280) (온·습도센서(BME 280 센서)를 이용한 PET/CT 장비의 항온 항습기 온·습도 평가)

  • Ryu, Chan-Ju;Kim, Jeong-A;Kim, Jun-Su;Yun, Geun-Yeong;Heo, Seung-Hui;Hong, Seong-Jong
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.15-22
    • /
    • 2020
  • PET(Positron Emission Tomography) devices are used as PET/CT or PET/MRI devices fused with the devices of CT or MRI for obtaining anatomical information. Therefore, the devices are constructed in circular ring-type structure whose length of gantry(the main part of filming) becomes wider and the interior depth becomes longer in comparison to other common medical equipments. scintillator, one of the components in PET devices, is inside the gantry, and as it is consisted of crystal which is sensitive to the change of temperature and humidity, large temperature change can cause the scintillator to be damaged. Though scintillator located inside the gantry maintains temperature and humidity with a thermo-hygrostat, changes in temperature and humidity are expected due to structural reasons. The output value was measured by dividing the inside of the gantry of the PET/CT device into six zones, each of which an Adafruit BME 280 temperature and humidity sensor was placed at. A thermo-hygrostat keeps the temperature and humidity constant in the PET/CT room. As the measured value of temperature and humidity of the sensor was obtained, the measured value of temperature and humidity appeared in the thermohygrostat was taken at the same time. Comparing the average measured values of temperature and humidity measured at each six zones with the average values of the thermo-hygrostat results in a difference of 2.71℃ in temperature and 21.5% in humidity. The measured temperature and humidity of PET Gantry is out of domestic quality control range. According to the results of the study, if there is continuous change in temperature and humidity in the future, the aging of the scintillator mounted in the PET Gantry is expected to be aging, so it is necessary to find a way to properly maintain the temperature and humidity inside the Gantry structure.

Prospective for Successful IT in Agriculture (일본 농업분야 정보기술활용 성공사례와 전망)

  • Seishi Ninomiya;Byong-Lyol Lee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.2
    • /
    • pp.107-117
    • /
    • 2004
  • If doubtlessly contributes much to agriculture and rural development. The roles can be summarized as; 1. to activate rural areas and to provide more comfortable and safe rural life with equivalent services to those in urban areas, facilitating distance education, tole-medicine, remote public services, remote entertainment etc. 2. To initiate new agricultural and rural business such as e-commerce, real estate business for satellite officies, rural tourism and virtual corporation of small-scale farms. 3. To support policy-making and evaluation on optimal farm production, disaster management, effective agro-environmental resource management etc., providing tools such as GIS. 4. To improve farm management and farming technologies by efficient farm management, risk management, effective information or knowledge transfer etc., realizing competitive and sustainable farming with safe products. 5. To provide systems and tools to secure food traceability and reliability that has been an emerging issue concerning farm products since serious contamination such as BSE and chicken flu was detected. 6. To take an important and key role for industrialization of farming or lam business enterprise, combining the above roles.