• 제목/요약/키워드: Korean Anthracite

검색결과 195건 처리시간 0.024초

삼천포와 서천 화력발전소에서 발생하는 석탄회중의 중금속 함량에 관한 연구 (Content of Heavy Metals in Coal Fly Ash from the Samcheonpo and the Seocheon Power Plant)

  • 윤정한;오근창;김용웅;신방섭
    • 자원환경지질
    • /
    • 제28권2호
    • /
    • pp.147-154
    • /
    • 1995
  • Coal fly ashes collected from the Samcheonpo and the Seocheon Power Plants were analyzed for major and minor components and heavy metals such as As, Cd, Co, Cr, Cu, Ga, Hg, Mo, Ni, Pb, Sb, V and Zn in order to suggest basic data to apply coal fly ash as fertilizer or soil ameliorator. The specific gravity of the samples was less than 2.0, and amounts of organic matter range from 5.0% to 12.3%. The identified minerals by XRD were mainly quartz, mullite and pyrite in anthracite coal, and mainly quartz and mullite in bituminous coal. Generally, the contents of heavy metal elements analyzed were lower less than those of soil, though higher in some samples. Element couples of some elements( e.g., As-Mo, Zn ; Mo-As, Sb, V, Zn ; Sb-Zn ) show positive correlations with each other, but the high correlations of toxic elements such as As, Pb, Cd and Hg indicate to give attention to apply coal fly ash as fertilizer or soil ameliorator.

  • PDF

여과-Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화 (Inactivation of Ralstonia Solanacearum using Filtration-Plasma Process)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제23권6호
    • /
    • pp.1165-1173
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor in nutrient solution culture, a filtration-DBD (dielectric barrier discharge) plasma reactor was investigated for the Ralstonia solanacearum which causes bacterial wilt in aquiculture. The filtration-DBD plasma reactor system of this study was consisted of filter, plasma reactor, reservoir. The DBD plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the inactivation of R. solanacearum with filter media type in filter reactor ranked in the following order: anthracite > fiber ball > sand > ceramic ball > quartz ceramic. In filtration + plasma process, disinfection effect with the voltage was found to small. In disinfection time of 120 minutes, residual R. solanacearum concentration was 1.17 log (15 CFU/mL). When the continuous disinfection time was 120 minute, disinfection effect was thought to keep the four days. In sporadic operation mode of 30 minutes disinfection - 24 hours break, residual R. solanacearum concentration after five days was 0.3 log (2 CFU/mL). It is considered that most of R. solanacearum has been inactivated substantially.

농촌지역의 효율적인 간이 상수처리에 관한 연구 (A Study on Efficient Simple Water Supply System in Rural Areas)

  • 이홍근;백남원;백도현
    • 한국환경보건학회지
    • /
    • 제22권3호
    • /
    • pp.103-115
    • /
    • 1996
  • The purpose of this study was to establish acceptable criteria for the design of simple water treatment plant in rural areas. To develop efficient simple water treatment methods for rural areas, water quality in the study areas was investigated and rapid and slow filtrations in pilot-scale were tested under various conditions. The main results of this study are as follows. It was found that the water qualities of the study areas exceed the drinking water standards, which implies that some treatments are required in rural areas. Treatment efficiencies of both rapid sand and dual-media (sand and anthracite) filtration without pre-treatment such as flocculation and sedimentation are very low, which were turned out to be unadequate for the rural areas. Treatment efficiencies of both vertical and horizontal slow filtration without chlorination are very high for consumed $KMnO_4, NH_3-N, NO_3-N$, turbidity, and very low for coliform and bacteria. Treatment efficiencies of both vertical and horizontal slow filtration with chlorination are very high over the most pollutants. A slow filtration with chlorination is efficient for the rural areas. An adequate depth of sand layer is over 60 cm. A horizontal filtration is more economical than a vertical filtration. A horizontal filtration can be operated for a relatively long periods of time without sand washing or replacement because clogging is removed by simple back-washing.

  • PDF

낙동강 하류원수에 적합한 여과지의 여재구성 (The adaptive filter configuration for down stream of Naktong river)

  • 김상구;류동춘;이영식;손진언
    • 한국환경과학회지
    • /
    • 제4권5호
    • /
    • pp.95-95
    • /
    • 1995
  • This study was carried out to evaluate the variations of headloss rate and of specific deposit to depths with effective size of media and configuration of filter layer during algae blooming period. 0.51mm size media was disqualified because most of headloss occurred rapidly below 5cm from surface layer however 0.91mm size media acted deep filtration more than 20cm from top, as result 0.91mm sixte media filter had 2∼3 times longer filtration time than 0.51mm sixte media filter, but 0.91mm size media have break-through potentiality. multi-layer filter with 1.02mm anthracite and 0.51mm sand had large deposit volume in upper layer that could longer filtration time, moreover smaller media in lower layer that could protect break-through.

Study on combustion and emission characteristics of chars from low-temperature and fast pyrolysis of coals with TG-MS

  • Liu, Lei;Gong, Zhiqiang;Wang, Zhenbo;Zhang, Haoteng
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.522-528
    • /
    • 2020
  • To achieve the clean and efficient utilization of low-rank coal, the combustion and pollutant emission characteristics of chars from low-temperature and fast pyrolysis in a horizontal tube furnace were investigated in a TG-MS analyzer. According to the results, the combustion characteristic of chars was poorer than its parent coals. The temperature range of gaseous product release had a good agreement with that of TGA weight loss. Gaseous products of samples with high content of volatile were released earlier. The NO and NO2 emissions of chars were lower than their parent coals. Coals of high rank (anthracite and sub-bituminous) released more NO and NO2 than low rank coals of lignite, so were chars from coals of different ranks. SO2 emissions of char samples were lower than parent coals and did not show obvious relationship with coal ranks.

Seasonal variation of assimilable organic carbon and its impact to the biostability of drinking water

  • Choi, Yonkyu;Park, Hyeon;Lee, Manho;Lee, Gun-Soo;Choi, Young-june
    • Environmental Engineering Research
    • /
    • 제24권3호
    • /
    • pp.501-512
    • /
    • 2019
  • The seasonal effects on the biostability of drinking water were investigated by comparing the seasonal variation of assimilable organic carbon (AOC) in full-scale water treatment process and adsorption of AOC by three filling materials in lab-scale column test. In full-scale, pre-chlorination and ozonation significantly increase $AOC_{P17\;(Pseudomonas\;fluorescens\;P17)}$ and $AOC_{NOX\;(Aquaspirillum\;sp.\;NOX)}$, respectively. AOC formation by oxidation could increase with temperature, but the increased AOC could affect the biostability of the following processes more significantly in winter than in warm seasons due to the low biodegradation in the pipes and the processes at low temperature. $AOC_{P17}$ was mainly removed by coagulation-sedimentation process, especially in cold season. Rapid filtration could effectively remove AOC only during warm seasons by primarily biodegradation, but biological activated carbon filtration could remove AOC in all seasons by biodegradation during warm season and by adsorption and bio-regeneration during cold season. The adsorption by granular activated carbon and anthracite showed inverse relationship with water temperature. The advanced treatment can contribute to enhance the biostability in the distribution system by reducing AOC formation potential and helping to maintain stable residual chlorine after post-chlorination.

유동층 연소로에서 국내탄 회재의 마모 특성 (Attrition Characteristics of Korean Antracite Ash in Fluidized Bed Combustors)

  • 이시훈;김상돈;김재성;이종민
    • 공업화학
    • /
    • 제17권5호
    • /
    • pp.547-551
    • /
    • 2006
  • ASTM D5757-95에 따른 입자 마모 측정기와 lab-scale 유동층 연소로에서 국내 무연탄 회재와 모래의 입자 마모 특성을 실험하였다. 기체유속에 따른 마모 특성으로 비산 회재의 입도 분포, 마모 속도, 마모율 등을 측정하였다. 일반적으로 유동층 층물질로 사용되는 모래보다 회재가 마모에 취약해 비산 회재의 발생이 높았으며 마모지수의 경우 5배 정도 높게 나타났다. 기체 유속 변화에 따라 입자의 마모에 의해 미세 입자의 생성이 지속적으로 발생하였으며 다음과 같은 식을 따른다. $$\frac{dW}{dt}=-3.18{\times}10^{-7}(U-U_{mf})W$$.

사각형 중간맨홀에서의 유사 퇴적 분석 및 산정식 제안 (Analysis and Suggestion of Estimation Equation for Sedimentation in Square Manholes with Straight Path)

  • 김정수;송주일;임창수;윤세의
    • 상하수도학회지
    • /
    • 제26권2호
    • /
    • pp.177-189
    • /
    • 2012
  • Sediment load deposited in sewers and manholes reduces not only the capacity of pipes but also the efficiency of the whole sewer system. This causes the inundations of the low places and overflows at manholes, Moreover, sulfides and bad odor can occur due to deposited sediment with organic loads in manholes. Movements of sediment load in manholes are complicated depending on manhole size, location, inside structure, sediment load type, and time. Therefore, it is necessary to understand the movements of sediment load in manholes by experiments. In this study, experiments were implemented by a square manhole with straight path to measure deposited sedimentation quantity. The experimental apparatus was consisted of a high water tank, an upstream tank, test pipes, a sediment supplier, a manhole, and a downstream tank to measure the experimental discharge. The quantity of deposited sediment load was measured by different conditions, such as the inflow condition of sediment(continuous and certain period), the amount of inflow sediment, discharge, and the type of sediment. Jumoonjin sand(S=2.63, D50=0.55mm), general sand(GS, S=2.65, D50=1.83mm) and anthracite (S=1.45, D50=0.80mm) were employed for the experiment. The velocities in inflow pipe were 0.45 m/s, 0.67 m/s, and 0.9 m/s. Sediment load movement and sedimentation quantity in manhole were influenced by many factors such as velocity, shear stress, viscosity, amount of sediment, sediment size, and specific gravity. Suggested regression equations can estimated the quantity of deposited sediment in the straight path square manholes. The connoted equations that were evaluated through the experimental study have velocity range from 0.45 to 0.9m/sec. The study results illustrates that appropriation of design velocity ragne between 1.0 and 2.0m/sec could implement to maintain and manage manholes.

급성(急性) CO 중독시(中毒時) 고압산소요법(高壓酸素療法)의 치료효과(治療效果)에 관(關)한 연구(硏究) (A Study on the Therapeutic Effectiveness of Hyperbaric Oxygenation on Acute CO poisoning)

  • 윤덕로;이강현
    • Journal of Preventive Medicine and Public Health
    • /
    • 제5권1호
    • /
    • pp.17-23
    • /
    • 1972
  • Carbon Monoxide poisoning is one of the most serious Public health problems in Korea. The incidence rate. officially reported has been known to be the highest in the world. This high incidence is mainly due to the wide prevalence of anthracite coal briquette as the domestic fuel for unique Korean heating system called 'ondol,' The coal briquette gas contains around 3-5% of Carbon Monoxide. A nation-wide effort to eliminate or reduce this serious hazards has produced little effect and the most hospitals are offering very ineffective measures such as oxygen inhalation through nasal catheter. Author has believed that this preventable accident should be approached by the secondary preventive measure because of our socio-economic status do not allow us optimistic results from primary preventive measure as far as the problem of CO poisoning is concerned. Author has treated 466 patients during 30 months period by Hyperbaric Oxygenation at Seoul National University Hospital. The results found are as follows. 1. Female has a higher incidence rate than male and the age group between 15-29 years showed highest incidence. 2. The recovery time depends on the time when the patients arrived at hospital. Earlier the arrival time, shorter the recovery time. 3. Some objective signs are representing typical physiological response to tissue hypoxia. 4. Therapeutic effectiveness of Hyperbaric Oxypenation is confirmed by such indices as recovery rate, Admission rate and average stay in hospital. Futher, these results are cocordant with other reports on the clinical value of Hyperbaric Oxygenation in the treatment of CO poisoning.

  • PDF

여과 성능향상을 위한 이단이층 복합여과시스템의 공정선정 연구 (A Study on the Process Selection for Two-stage and Dual Media Filtration System for Improving Filtration Performance)

  • 송시범;조민;남상호;우달식
    • 상하수도학회지
    • /
    • 제21권2호
    • /
    • pp.203-214
    • /
    • 2007
  • This study aimed at researching the process selection for two-stage and dual media filtration system, as a technology substituting the existing sand filter without expanding the site when retrofitting an old filter bed or designing a new one. In order to select the process for optimum complex filtration system, three running conditions have been tested. Test results demonstrated that Run 3 in which the 1st stage was filled with anthracite and coarse sand, and the 2nd stage was filled up with activated carbon and fine sand reduced the head loss and the load of turbidity substances. Also, Run 3 showed better performance in removing TOC, particle counts, THMFP and HAAFP, compared to other two conditions. 99 % of Cryptosporidium was removed. Bisphenol-A was rarely removed from the 1st stage of coarse sand and 2nd stage of fine sand, but 99 % of it was removed from the 2nd stage of activated carbon. In conclusion, when it is required to retrofit an old rapid filter bed or design a new one for the purpose of improving filtration performance, the following two-stage and dual media filtration system is suggested: the 1st stage of filter bed needs to be filled up with coarse sand to remove turbidity as the pretreatment for extending duration of filtering, the top part of 2nd stage needs to be filled up with granular activated caron to remove dissolved organic matters and others as the main process, and finally the bottom part of 2nd stage needs to be filled up with fine sand as the finishing process.