• Title/Summary/Keyword: Korea Medicine Information

Search Result 3,024, Processing Time 0.036 seconds

Development of Wireless Ambulatory Measurement System based on Inertial Sensors for Gait Analysis and its Application for Diagnosis on Elderly People with Diabetes Mellitus (관성센서 기반의 무선보행측정시스템 개발 및 노인 당뇨 환자 보행 진단에의 응용)

  • Jung, Ji-Yong;Yang, Yoon-Seok;Won, Yong-Gwan;Kim, Jung-Ja
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.48 no.2
    • /
    • pp.38-46
    • /
    • 2011
  • 3D motion analysis system which is currently widely used for walking analysis has limitations due to both necessity of wide space for many cameras for measurement, high cost, and complicated preparation procedure, which results in low accessability in use and application for clinical diagnosis. To resolve this problem, we developed 3-dimensional wireless ambulatory measurement system based on inertial sensor which can be easily applicable for clinical diagnosis for lower extremity deformity and developed system was evaluated by applying for 10 elderly people with diabetes mellitus. Developed system was composed of wireless ambulatory measurement module that consists of inertial measurement unit (IMU) which measures the gait characteristics, microcontroller which collects and precesses the inertial data, bluetooth device which transfers the measured data to PC and Window's application for storing and processing and analyzing received data. This system will utilize not only to measure lower extremity (foot) problem conveniently in clinical medicine but also to analyze 3D motion of human in other areas as sports science, rehabilitation.

Comparison of Attitude Toward Antidepressants Between Medical and Surgical Group Outpatients in a Korean University Hospital (일 대학병원 내과계열 및 외과계열 외래 환자들의 항우울제에 대한 태도 및 인식에 대한 연구)

  • Lee, Sang-Soo;Seo, Jeok-Seok;Moon, Seok-Woo;Nam, Beom-Woo
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.16 no.1
    • /
    • pp.52-58
    • /
    • 2008
  • Objectives : Antidepressants are prescribed by not only psychiatrists but also general practitioners. However, patients' negative attitude and stigma against antidepressants are major obstacles to prescribe antidepressants in nonpsychiatric outpatient departments. We, therefore, examined patients' attitude toward antidepressant in medical and surgical group outpatient in Korea. Methods : Short item questionnaire was applied to medical group and surgical group outpatients who consented to this survey in a Korean university hospital. 100 medical and 100 surgical outpatients were surveyed. The questionnaire contained sociodemographic information, previous recognition of antidepressant, and general attitude toward attidepressants. Results : Of the 212 recipients, exclusive of erroneous and missing ones, we analyzed 200 recipients. 1) We found negative attitude toward antidepressants among both medical and surgical outpatients. 2) Medical group outpatients are answered more' antidepressants cause physically ill. 3) The persons who didn't take previously antidepressants showed more negative attitudes. 4) The most reason why they refuse to take antidepressants is concerns of side effects of antidepressants. Conclusion : There are highly negative attitude toward antidepressants between medical and surgical group outpatients. Study findings suggest the need for an active education on antidepressants to nonpsychiatric outpatients to maximize their therapeutic effect and compliance.

  • PDF

Susceptibility-Contrast-Enhanced MR Venography of Cat Brain Using Tailored RF Pulse at High Magnetic Field of 4.7 Tesla Superconducting Magnet (4.7T 고자장 초전도 자석에서 Tailored RF를 이용한 고양이 뇌의 자화율 강조영상법에 의한 자기공명혈관 조영술)

  • Moon, Chi-Woong;Kim, Sang-Tae;Lee, Dae-Geun;Im, Tae-Hwan;No, Yong-Man;Cho, Jang-Hee;Lee, Yoon
    • Progress in Medical Physics
    • /
    • v.5 no.1
    • /
    • pp.55-66
    • /
    • 1994
  • After proving home-made imaging pulse sequences including tailored RF pulse by phantom, susceptibility-contrast-enhanced MR venograms of cat brain were obtained using tailored RF gradient-echo(TRGE) method. Sagittal MR imaging of the cat brain obtained by TRGE technique shows several veins, for example, dorsal sagittal sinus, straight sinus, vein of corpus callosum and internal cerebral vein, etc., compared with cats anatomical figure. Tailored RF waveform was generated by PASCAL language in ASPECT 3000 computer(Switzland, Bruker). Rectangular-shaped slice profile with bi-linear ramp function as phase distribution in the slice, at which maximum value was 2$\pi$, was fourier transformed to make tailored RF pulse. Experimental MR imaging parameters were TR/TE=205/10 msec, slice thickness TH=7mm, maxtrix size=256$\times$256, in-plane resolution=0.62$\times$0.31mm$^2$, and field of view(FOV)=8cm for both conventional gradient-echo(GE) imaging and TRGE imaging techniques.

  • PDF

Improvement of Fourier Transform Arteriography by Use of Ramped RF Profile and Dual Projections (경사 윤곽의 고주파 펄스와 이중 투사법에 의한 Fourier 변환 동맥 혈관 촬영법의 성능 향상)

  • Jung, K. J.;Kim, I. Y.;Lee, M. W.;Yi, Y.
    • Investigative Magnetic Resonance Imaging
    • /
    • v.6 no.1
    • /
    • pp.41-46
    • /
    • 2002
  • The Fourier transform arteriography (FTA) exploits the periodic variation of arterial flow velociety of arterial flow velocity in stnchronized with cardiac cycles. This technique is intrinsically unique compared to other modern techniques. This technique separates the arteries from the veins using the pulsatile arterial flow without using the presaturation RF pulses. Therefore, it has less RF deposition and is free from the dark band artifacts that can arise from retrograde flow and curved arteries. Furthermore, it is free from the artifacts induced by eddy currents. However, there are some drawbacks such as a single projection view and the saturation of arteries at the end of an imaging slab. These drawbacks are circumvented by applying recently developed techniques. The fast gradient switching capability of modern MRI systems enabled us to incorporate dual projection views into the conventional FTA sequence without increasing the repetition time. In addition, signals from the distal arteries were enhanced by use of a ramped RF pulse and therefore the distal arteries were less saturated. By use of the FTA sequence with dual projection views and the ramped RF pulse, we acquired the sagittal and coronal projection views of femoral arteriograms simultaneously with more enhanced signals of distal arteries than the conventional FTA.

  • PDF

Instant noodle consumption is associated with cardiometabolic risk factors among college students in Seoul

  • Huh, In Sil;Kim, Hyesook;Jo, Hee Kyung;Lim, Chun Soo;Kim, Jong Seung;Kim, Soo Jin;Kwon, Oran;Oh, Bumjo;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • v.11 no.3
    • /
    • pp.232-239
    • /
    • 2017
  • BACKGROUND/OBJECTIVES: Increased consumption of instant noodles has recently been reported to be positively associated with obesity and cardiometabolic syndrome in South Korea, which has the highest per capita instant noodle consumption worldwide. This study aimed to investigate the association between instant noodle consumption and cardiometabolic risk factors among college students in Seoul. SUBJECTS/METHODS: The study subjects consisted of 3,397 college students (1,782 male; 1,615 female) aged 18-29 years who participated in a health checkup. Information on instant noodle consumption was obtained from the participants' answers to a question about their average frequency of instant noodle intake over the 1 year period prior to the survey. RESULTS: Statistical analysis using a general linear model that adjusted for age, body mass index, gender, family income, health-related behaviors, and other dietary factors important for cardiometabolic risk, showed a positive association between the frequency of instant noodle consumption and plasma triglyceride levels, diastolic blood pressure, and fasting blood glucose levels in all subjects. Compared to the group with the lowest frequency of instant noodle intake (${\leq}1/month$), the odds ratio for hypertriglyceridemia in the group with an intake of ${\geq}3/week$ was 2.639 [95% confidence interval (CI), 1.393-5.000] for all subjects, while it was 2.149 (95% CI, 1.045-4.419) and 5.992 (95% CI, 1.859-21.824) for male and female students, respectively. In female students, diastolic blood pressure was also higher among more frequent consumers of instant noodles. CONCLUSIONS: Our results suggest that frequent consumption of instant noodles may be associated with increased cardiometabolic risk factors among apparently healthy college students aged 18-29 years.

Suggestion of a Basis Color and Standardization for Observing a Person's Face Color of Ocular Inspection (한방 망진의 찰색을 위한 표준화 및 색 기준 설정안의 제안)

  • Lee, Se-Hwan;Kim, Bong-Hyun;Cho, Dong-Uk
    • The KIPS Transactions:PartB
    • /
    • v.15B no.5
    • /
    • pp.397-406
    • /
    • 2008
  • Despite the effectiveness of oriental medical practice in the diagnosis of symptoms and providing cure to it, the preferences in western medicinal values is socially prevalent. The diagnosis of a disease using western medicinal practices provides us with an objective diagnostic result, however, decisions by oriental doctors are based on their heuristic intuitions developed by practice and experience. Objective solutions for the cure of symptoms using oriental medical therapy can have a high impact on the world market. Therefore, development of diagnostic machines based on oriental therapy can enhance the Ocular Inspection which is evaluated as one of the best diagnostic treatment among Oriental Medical Science, is not researched much compared to other diagnoses. Because there is no color diagnosis rules for digital machines to analyze the actual color, looking at the person's face color is one of the most important components to diagnose the disease or illness. The thesis proposes the implementation of absolute observing a person's face color standards of the color settings for objective diagnosis. As a results, comparative digital color analysis for observing a person's face color can be the most effective rule based Color scheme system to diagnose disease. A standard solution for the researching conditions is suggested to reduce the variable which may occur depending on the differences between the researching conditions.

Plasma D-dimer Can Effectively Predict the Prospective Occurrence of Ascites in Advanced Schistosomiasis Japonica Patients

  • Wu, Xiaoying;Ren, Jianwei;Gao, Zulu;Xu, Yun;Xie, Huiqun;Li, Tingfang;Cheng, Yanhua;Hu, Fei;Liu, Hongyun;Gong, Zhihong;Liang, Jinyi;Shen, Jia;Liu, Zhen;Wu, Feng;Sun, Xi;Niu, Zhongzheng;Ning, An
    • Parasites, Hosts and Diseases
    • /
    • v.55 no.2
    • /
    • pp.167-174
    • /
    • 2017
  • China still has more than 30,000 patients of advanced schistosomiasis while new cases being reported consistently. D-dimer is a fibrin degradation product. As ascites being the dominating symptom in advanced schistosomiasis, the present study aimed to explore a prediction model of ascites with D-dimer and other clinical easy-achievable indicators. A case-control study nested in a prospective cohort was conducted in schistosomiasis-endemic area of southern China. A total of 291 patients of advanced schistosomiasis were first investigated in 2013 and further followed in 2014. Information on clinical history, physical examination, and abdominal ultrasonography, including the symptom of ascites was repeatedly collected. Result showed 44 patients having ascites. Most of the patients' ascites were confined in the kidney area with median area of $20mm^2$. The level of plasma D-dimer and pertinent liver function indicators were measured at the initial investigation in 2013. Compared with those without ascites, cases with ascites had significantly higher levels of D-dimer ($0.71{\pm}2.44{\mu}g/L$ vs $0.48{\pm}2.12{\mu}g/L$, P=0.005), as well ALB (44.5 vs 46.2, g/L) and Type IV collagen (50.04 vs $44.50{\mu}g/L$). Receiver operating characteristic curve analyses indicated a moderate predictive value of D-dimer by its own area under curve (AUC) of 0.64 (95% CI: 0.54-0.73) and the cutoff value as $0.81{\mu}g/L$. Dichotomized by the cutoff level, D-dimer along with other categorical variables generated a prediction model with AUC of 0.76 (95% CI: 0.68-0.89). Risks of patients with specific characteristics in the prediction model were summarized. Our study suggests that the plasma D-dimer level is a reliable predictor for incident ascites in advanced schistosomiasis japonica patients.

The Analysis of the Number of Donations Based on a Mixture of Poisson Regression Model (포아송 분포의 혼합모형을 이용한 기부 횟수 자료 분석)

  • Kim In-Young;Park Su-Bum;Kim Byung-Soo;Park Tae-Kyu
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • The aim of this study is to analyse a survey data on the number of charitable donations using a mixture of two Poisson regression models. The survey was conducted in 2002 by Volunteer 21, an nonprofit organization, based on Koreans, who were older than 20. The mixture of two Poisson distributions is used to model the number of donations based on the empirical distribution of the data. The mixture of two Poisson distributions implies the whole population is subdivided into two groups, one with lesser number of donations and the other with larger number of donations. We fit the mixture of Poisson regression models on the number of donations to identify significant covariates. The expectation-maximization algorithm is employed to estimate the parameters. We computed 95% bootstrap confidence interval based on bias-corrected and accelerated method and used then for selecting significant explanatory variables. As a result, the income variable with four categories and the volunteering variable (1: experience of volunteering, 0: otherwise) turned out to be significant with the positive regression coefficients both in the lesser and the larger donation groups. However, the regression coefficients in the lesser donation group were larger than those in larger donation group.

A simulation study of speech perception enhancement for cochlear implant patients using companding in noisy environment (잡음 환경에서 압신을 이용한 인공 와우 환자의 언어 인지 향상 시뮬레이션 연구)

  • Lee Young-Woo;Ji Yoon-Sang;Lee Jong-Shil;Kim In-Young;Kim Sun-I.;Hong Sung-Hwa;Lee Sang-Min
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.43 no.5 s.311
    • /
    • pp.79-87
    • /
    • 2006
  • In this study, we evaluated the performance of a companding strategy as a preprocessing for speech enhancement and noise reduction. The proposed algorithm is based on two tone suppression that is human's hearing characteristics. This algorithm enhances spectral peak of speech signal and reduces background noise, however it has tradeoff characteristics between speech distortion and noise reduction due to limited channel number and nonlinear block. Therefore, we designed two different companding structures that have relative characteristics of noise reduction and speech distortion and found suitable companding structures by difference of individual speech perception ability in noise environment. Thus we proposed speech perception enhancement of cochlear implant user in noise environment with low SNR. The performance of the proposed algorithm was evaluated through 5 normal hearing listeners using noise band simulation. Improvement of speech perception was observed for all subjects and each subject preferred the different type of companding structure.

Longitudinal measurements of tooth mobility following orthodontic treatment (교정치료 후 치아동요도 감소에 대한 종단적 계측연구)

  • Hwang, Hyeon-Shik;Kim, Wang-Sik;Kim, Jeong-Moon;Mcnamara, James A. Jr.
    • The korean journal of orthodontics
    • /
    • v.40 no.1
    • /
    • pp.34-39
    • /
    • 2010
  • Objective: The aim of the present study was to evaluate the changes in tooth mobility following orthodontic treatment and to obtain information regarding the guideline of retainer wear duration during the post-treatment period. Methods: The sample consisted of twenty patients who had been treated with edgewise appliances. The mobility of the maxillary teeth from the central incisor to the first molar was measured bilaterally by way of the $Periotest^{(R)}$, a non-invasive, electronic device that provides an objective measurement of the reaction of the periodontium to a defined impact load. Tooth mobility was monitored at the time of the removal of the orthodontic appliances and subsequently at three-month intervals during the two years following appliance removal. Results: Tooth mobility decreased rapidly for the first six months and then decreased at a slower rate during the next six months; no statistically significant decrease in mobility was observed during the second year following appliance removal. Conclusions: The results of the present study suggest that adequate tooth stabilization is critical during the first six months following appliance removal and that continued wearing of retainers is recommended at least until twelve months after the completion of orthodontic treatment.