• Title/Summary/Keyword: Koh Chang

Search Result 990, Processing Time 0.028 seconds

MVP Chemotherapy and Hyperfractionated Radiotherapy for Stage III Unresectable Non-Small Cell Lung Cancer - Randomized for Maintenance Chemotherapy vs. Observation; Preliminary Report (제 3 기의 진행성 비소세포 폐암에서의 MVP 복합 항암 용법과 다분할 방사선 치료 -추가 항암 요법에 대한 임의 선택-)

  • Choi, Euk-Kyung;Chang, Hye-Sook;Suh, Cheol-Won;Lee, Kyoo-Hyung;Lee, Jung-Shin;Kim, Sang-Hee;Choi, Chul-Joon;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Won-Dong;Kim, Sam-Hyun;Sohn, Kwgng-Hyun
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.215-219
    • /
    • 1991
  • To evaluate the effect of MVP chemotherapy and hyperfractionated radiotherapy in Stage III unresectable non small cell lung cancer (NSCLC), authors have conducted a prospective randomized study since January 1991, Stage IIIa or IIIb unresectable NSCLC patients were treated with hyperfractionated radiotherapy (120 cGy/fx BID) up to 6500 cGy following 3 cycles of induction MVP (Mitomycin C 6 mg/$m^2$, Vinblastine 6 mg/$m^2$, Cisplatin 60 mg/$m^2$) and randomized for either observation or 3 cycles of maintenance MVP chemotherapy. Until August 1991, 18 patients were registered to this study. 4 cases were stage IIIa and 14 were stage IIIb. Among 18 cases 2 were lost after 2 cycles of chemotherapy, and 46 were analyzed for this preliminary report. The response rate of induction chemotherapy was $62.5\%$ : partial response, $50\%$ and minimal response, $12.5\%$. Residual tumor of the one partial responder was completely disappeared after radiotherapy. Among 6 cases who were progressed during induction chemotherapy, 4 of them were also progressed after radiotherapy. All patients were tolerated BID radiotherapy without definite increase of acute complications, compared with conventional radiotherapy group. But at the time of this report, one patient expired in two month after the completion of the radiotherapy because of treatment related complication. Although the longer follow up is needed, authors are encouraged with higher response rate and acceptable toxicity of this treatment. Authors believe that this study is worthwhile to continue.

  • PDF

Shattering Ratio of Manganese Nodule and Physical Properties of Powdered Manganese Nodule and Sea eottom Sediment (망간단괴의 분화율과 망간단괴 분말 및 해저퇴적물의 물리적 특성)

  • Choi, Hun-Soo;Kang, Jung-Seock;Chang, Se-Won;Koh, Sang-Mo;Um, In-Kwon
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.277-287
    • /
    • 2007
  • To understand the effects of the powdered manganese nodule and sea bottom sediment pumped up with nodules on the mining process, the shattering ratio of manganese nodule and their physical properties are analyzed. The self shattering ratio and crushing shattering ratio are about 27% and about 3%, respectively. Then total shattering ratio is about 30%. The initial turbidity of the powdered manganese nodule and the bottom sediment show high, i.e., about 3,100 and 1,850 respectively. But their turbidities decrease rapidly with time. After 1 hour, turbidity of the powdered manganese nodule drops to about 1,570 and that of the bottom sediment to 1,310. The turbidity of Na-bentonite changes from 820 to 730 after 1 h and to 700 after 2 h. The viscosity of powdered manganese nodule is $1.4{\sim}1.5cP$, and the viscosity of bottom sediment is less than 1 cP. The viscosity fo Na-bentonite is initially 37.2 and increase with time to 86.4 cP after 30 min. The high initial turbidity of powdered manganese nodule is due to dark color of the powder. The high specific gravity makes rapid precipitation and then decreases the turbidity rapidly. The bottom sediment shows high initial turbidity because of easy suspension with very fine particle size. But it cannot be hydrated and formed gel in suspension, then it is easily precipitated. However Na-bentonite is hydrated to the expended state and makes gel state, then it shows high turbidity and high viscosity. These physical properties of the powdered manganese nodule suggest that the powder of manganese nodule should not make scaling inside of lifting pipe or pump. And the bottom sediment lifted up with manganese nodule should not play the role of drilling mud shch as Na-bentonite.

Eco-friendly and efficient in situ restoration of the constructed sea stream by bioaugmentation of a microbial consortium (복합미생물 생물증강법을 이용한 인공해수하천의 친환경 효율적 현장 수질정화)

  • Yoo, Jangyeon;Kim, In-Soo;Kim, Soo-Hyeon;Ekpeghere, Kalu I.;Chang, Jae-Soo;Park, Young-In;Koh, Sung-Cheol
    • Korean Journal of Microbiology
    • /
    • v.53 no.2
    • /
    • pp.83-96
    • /
    • 2017
  • A constructed sea stream in Yeongdo, Busan, Republic of Korea is mostly static due to the lifted stream bed and tidal characters, and receives domestic wastewater nearby, causing a consistent odor production and water quality degradation. Bioaugmentation of a microbial consortium was proposed as an effective and economical restoration technology to restore the polluted stream. The microbial consortium activated on site was augmented on a periodic basis (7~10 days) into the most polluted site (Site 2) which was chosen considering the pollution level and tidal movement. Physicochemical parameters of water qualities were monitored including pH, temperature, DO, ORP, SS, COD, T-N, and T-P. COD and microbial community analyses of the sediments were also performed. A significant reduction in SS, COD, T-N, and COD (sediment) at Site 2 occurred showing their removal rates 51%, 58% and 27% and 35%, respectively, in 13 months while T-P increased by 47%. In most of the test sites, population densities of sulfate reducing bacterial (SRB) groups (Desulfobacteraceae_uc_s, Desulfobacterales_uc_s, Desulfuromonadaceae_uc_s, Desulfuromonas_g1_uc, and Desulfobacter postgatei) and Anaerolinaeles was observed to generally decrease after the bioaugmentation while those of Gamma-proteobacteria (NOR5-6B_s and NOR5-6A_s), Bacteroidales_uc_s, and Flavobacteriales_uc_s appeared to generally increase. Aerobic microbial communities (Flavobacteriaceae_uc_s) were dominant in St. 4 that showed the highest level of DO and least level of COD. These microbial communities could be used as an indicator organism to monitor the restoration process. The alpha diversity indices (OTUs, Chao1, and Shannon) of microbial communities generally decreased after the augmentation. Fast uniFrac analysis of all the samples of different sites and dates showed that there was a similarity in the microbial community structures regardless of samples as the augmentation advanced in comparison with before- and early bioaugmentation event, indicating occurrence of changing of the indigenous microbial community structures. It was concluded that the bioaugmentation could improve the polluted water quality and simultaneously change the microbial community structures via their niche changes. This in situ remediation technology will contribute to an eco-friendly and economically cleaning up of polluted streams of brine water and freshwater.

A Study of the Insulin and the C-Peptide Responses to Oral Glucose Load in Nondiabetic and Diabetic Subjects (정상인(正常人) 및 당뇨병환자(糖尿病患者)에서의 경구당부하시(經口糖負荷時) 혈중(血中) Insulin과 C-Peptide의 변동(變動))

  • Lee, Myung-Chul;Choi, Sung-Jae;Kim, Eung-Jin;Min, Hun-Ki;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.17-32
    • /
    • 1977
  • The present study was undertaken to evaluate the significance of the insulin and the C-peptide rseponse to oral glucose loads in normal and diabetic subjects and to establish the effects of the obesity. In this study, the authors have measured plasma insulin and C-peptide by means of radioimmunoassay in 10 nonobese normal, 5 obese normal, 13 nonobese moderate diabetic patients, 9 obese moderate diabetic patients and 9 severe diabetic patients. The results obtained were as follows; 1. In 10 nonobese normal subjects, the plasma insulin level at fasting state and at 30, 60, 90, and 120 min after oral glucose loads were $15.7{\pm}3.4,\;48.3{\pm}9.8,\;40.4{\pm}6.7,\;37.4{\pm}6.5\;and\;26.0{\pm}4.2uU/ml(Mean{\pm}S.E.)$ and C-peptide were $1.9{\pm}0.3,\;3.9{\pm}0.6,\;6.3{\pm}0.6,\;5.7{\pm}0.5\;and\;4.0{\pm}0.5ng/ml$. The change of C-peptide was found to go almost parallel with that of insulin and the insulin value reaches to the highest level at 30 min whereas C-peptide reaches to its peak at 60min. 2. The plasma insulin level in 5 obese normal subjects were $38.9{\pm}12.3,\;59.5{\pm}12.3,\;59.2{\pm}17.1,\;56.1{\pm}20.0\;and\;48.4{\pm}17.2uU/ml$ and the C-peptide were $5.5{\pm}0.4,\;6.8{\pm}0.5,\;7.9{\pm}0.8,\;7.9{\pm}0.8\;and\;7.8{\pm}2.0ng/ml$. The insulin response appeared to be greater than nonobese normal subjects. 3. In 13 nonobese moderate diabetic patients, the plasma insulin levels were $27.1{\pm}4.9,\;44.1{\pm}6.0,\;37.3{\pm}6.6,\;35.5{\pm}8.1\;and\;34.7{\pm}10.7uU/ml$ and the C-peptide levels were $2.7{\pm}0.4,\;4.9{\pm}0.7,\;6.5{\pm}0.5,\;7.0{\pm}0.3\;and\;6.7{\pm}1.0ng/ml$. There was little significance compared to nonobese normal groups but delayed pattern is noted. 4. In 9 obese moderated diabetic patients, the plasma insulin levels were $22.1{\pm}7.9,\;80.0{\pm}19.3,\;108.0{\pm}27.0,\;62.0{\pm}17.6\;and\;55.5{\pm}10.1uU/ml$ and the C-peptide levels were $5.2{\pm}0.4,\;8.0{\pm}1.0,\;10.4{\pm}1.6,\;10.4{\pm}1.7\;and\;10.1{\pm}1.0ng/ml$ and its response was also greater than that of nonobese moderate diabetic patients. 5. The plasma insulin concentrations in 9 severe diabetic subjects were $8.0{\pm}3.8,\;12.1{\pm}3.5,\;16.8{\pm}4.6,\;19.6{\pm}5.2\;and\;15.0{\pm}5.0uU/ml$ and the C-peptide levels were $1.6{\pm}0.3,\;2.4{\pm}0.4,\;4.1{\pm}0.6,\;4.0{\pm}0.8\;and\;4.5{\pm}0.7ng/ml$ and the insulin and C-peptide responses were markedly reduced in severe diabetic groups. 6. There were-significant differences between each groups of patients on the magnitude of total insulin or C-peptide areas, the insulinogenic index and the C-peptide index.

  • PDF

Permanent Hypothyroidism after Radioactive Iodine($^{131}I$) Treatment in Diffuse Toxic Goiter (독성미만성갑상선종환자에서 방사성옥소(放射性沃素)($^{131}I$)투여후(投與後) 발생(發生)하는 영구적갑상선기능저하증(永久的甲狀腺機能低下症))

  • Park, Seon-Yang;Lee, Jung-Sang;Lee, Hong-Kyu;Koh, Chang-Soon;Lee, Mun-Ho
    • The Korean Journal of Nuclear Medicine
    • /
    • v.11 no.1
    • /
    • pp.39-48
    • /
    • 1977
  • Radioactive iodine(RAI), principally $^{131}I$, effectively controls hyperthyroidism in the majority of patients. The subsequent development of hypothyroidism, however, has been of increasing concern since it was first pointed out by Chapman and Maloof in 1955. And the steady increase of late hypothyroidism during the passage of time was known with its relation with dosage of RAI. The authors have investigated the development of hypothyroidism in 935 patients with diffuse toxic goiter(DTG) who were treated with ($RAI^{131}I$) at the Seoul National University Hospital from 1960 to 1977 to reveal its relation with the number of RAI treatments, dosage of RAI, age of patients and exophthalmos with the following results. 1) The incidence of hypothyroidism by year after RAI therapy among 631 patients with DTG who were treated with single RAI regimen was 7.4%(1 year), 11.8%(2 year), 16.2%(3 year), 22.1%(4 year) and 25.5%(5 year), and that among 163 patients given multiple RAI treatments was 8.6%(1 year), 10.4%(2 year), 13.3%(3 year), 29.1%(4 year), and 54.1%(5 year)respectively showing much higher year1y increments from 4 years after RAI treatment. in comparison with the former. 2) Among 550 patients in the lower dose group treated with single RAI regimen less than 5.0mCi ($Mean{\pm}S.D.:\;4.3{\pm}0.6mCi$), the incidence of hypothyroidism by year after RAI treatment was 6.8%(1 year), 11.4%(2 year), 15.4%(3 year), while among 81 patients in the higher dose group given single RAI treatment not less than 5.5 mCi ($Mean{\pm}S.D.:\;6.3{\pm}0.5mCi$) it was 12.0%(1 year), 15.4%(2 year) and 20.4%(3 year) respectively. However, the duration till euthyroid state after RAI therapy in the two groups was $5.1{\pm}3.6$ months and $4.8{\pm}2.8$ months respectively showing no statistically signficant difference (p>0.1). 4) The incidence of hypothyroidism after RAI treatment in patients younger than 30 years of age was 4.3%(1 year) and 7.7%(2 year); in patients from 30 years to 49 years of age, 5.8%(1 year) and 11.1%(2 year); and in those older than 50 years, 11.0%(1 year) and 14.4%(2 year). The data revealed rising incidence of hypothyroidism with increase of patients' age. 4) Among 116 patients with exophthalmos the incidence of hypothyroidism by year after RAI treatment was 7.1%(1 year) and 12.1%(2 year) while that among 184 patients without exophthalmos was 7.3%(1 year) and 12.2%(2 year) respectively. With the above data the authors could conclude that the hypothyroidism in patients with DTG who were treated by RAI developed more frequently than reported by others in Korea till now, and increased with the passage of time, the yearly increments from 4 years after RAI treatment increasing markedly in the multiple dose group, and the incidence could be reduced by decreasing the administered RAI doe not increasing the duration till euthyroid state after RAI therapy.

  • PDF

A Study on Skin Status with Acoustic Measurements of Skin Friction Noise (피부 마찰 소음 측정을 통한 피부 상태 연구)

  • Chang, Yun Hee;Seo, Dae Hoon;Koh, A Rum;Kim, Sun Young;Lim, Jun Man;Han, Jong Seup;Lee, Sang Hwa;Park, Sun Gyoo;Kim, Yang Han
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.42 no.2
    • /
    • pp.103-109
    • /
    • 2016
  • Efficacy of cosmetics has been mainly evaluated by qualitative and quantitative methods based on visual sense, tactile sense and skin structure until now. In this study, we suggested a novel evaluation method for skin status based on sound; measuring and analyzing the rubbing noise generated by applying cosmetics. First, the rubbing noise was measured at a close range by a high-sensitivity microphone in anechoic environment, and the noises were analyzed by 1/3 octave band analysis in frequency-domain. Three conditions, 1) before washing, 2) after washing and 3) after application of cosmetics, were compared. As a result, sound pressure level (SPL) of rubbing noise after washing was larger than that of before washing, and the SPL of rubbing noise after cosmetic application was the smallest. Furthermore, the energy of rubbing noise after application was higher than that of the before and after washing conditions in a low frequency band (lower than 2 kHz region). Conversely, the energy of rubbing noise after application was much lower than the others in a high-frequency band (upper than 2 kHz region). This change of energy distribution was described as a balloon-skin model. High SPL in the low frequency region after the cosmetic applications was due to the increase of "flexibility index", while SPL in the high frequency region significantly decreased because of the attenuation which is related to "softness index". Therefore, we developed two indices based on the spectrum-energy difference for evaluating skin conditions. This proposed method and indices were verified via skin flexibility and roughness measurement using cutometer and primos respectively. These results suggest that acoustic measurement of skin friction noise may be a new skin status evaluation method.

The Clinical Outcome of Dedifferentiated Chondrosarcoma (역분화 연골육종의 임상 결과)

  • Kong, Chang-Bae;Lee, Seung Yong;Song, Won-Seok;Cho, Wan-Hyeong;Koh, Jae-Soo;Jeon, Dae-Geun
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.2
    • /
    • pp.164-171
    • /
    • 2019
  • Purpose: A dedifferentiated chondrosarcoma is a rare lethal tumor characterized by a low grade chondrosarcoma juxtaposed with a high grade dedifferentiated sarcoma, such as osteosarcoma, fibrosarcoma. The aim of our study was to document the clinical manifestation and oncologic outcomes of a dedifferentiated chondrosarcoma. Materials and Methods: This study identified 11 patients who were diagnosed and treated for dedifferentiated chondrosarcoma between January 2007 and December 2016. The identified cohort was then reviewed regarding age, sex, symptom onset, tumor location, magnetic resonance imagings (MRIs), surgical margin, and pathologic diagnosis. The time to local recurrence and/or metastasis, follow-up duration, and the patients' final status were analyzed. Results: The patients were comprised of 7 males and 4 females with a mean age of 54 years (range, 33-80 years). The location of the tumor was in the femur in 6 cases, pelvis in 4 cases, and metatarsal in 1 case. The average tumor diameter was 12.7 cm (range, 6.0-26.1 cm). At the time of diagnosis, 2 patients showed pathologic fracture; 1 patient was Enecking stage IIA, 9 patients were stage IIB, and 1 patient was stage III. Eight patients were classified as a primary dedifferentiated chondrosarcoma and 3 patients were secondary. One of the primary lesions was misinterpreted initially as a low grade chondroid lesion by MRI and underwent curettage. Local recurrence occurred in 8 cases and distant metastasis occurred in 10 cases with a mean duration of 8 months (range, 2-23 months) and 7 months (range, 1-32 months), respectively. The three-year overall survival of patients with dedifferentiated chondrosarcoma was 18%, and 10 patients died due to disease progression. Conclusion: Dedifferentiated chondrosarcoma developed lung metastases in the early period of the clinical courses and the prognosis was dismal.

The Long-term Follow-up Study of Therapeutic Effects of 8 French Catheter for Spontaneous Pneumothorax (자연 기흉의 치료에서 8 French 도관삽입의 치료 효과에 대한 장기적 관찰)

  • Shin, Jong-Wook;Lee, Byoung-Hoon;An, Chang-Hyeok;Choi, Jae-Sun;Yoo, Jee-Hoon;Lim, Seong-Yong;Kang, Yoon-Jung;Koh, Hyung-Ki;Kim, Jae-Yeol;Na, Moon-Jun;Park, In-Won;Sobn, Dong-Suep;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1094-1104
    • /
    • 1997
  • Background : Spontaneous pneumothoraces(SP) are divided into primary spontaneous pneumothoraces (PSP) which develop in healthy individuals without underlying pulmonary disorders and secondary spontaneous pneumothoraces(SSP) which occur in those who have underlying disorders such as tuberculosis or chronic obstructive lung diseases. Yet there is no established standard therapeutic approach to this disorder, i.e., from the spectrum of noninvasive treatment such as clinical observation with or without oxygen therapy, to aggressively invasive thoracoscopic bullectomy or open thoracotomy. Although chest tube thoracostomy has been most widely used, the patients should overcome pain in the initiation of tube insertion or during indwelling it potential infection and subcutaneous emphysema. Thus smaller-caliber tube has been challenged for the treatment of pneumothorax. Previously, we studied the therapeutic efficacy of 8 French catheter for spontaneous pneumothorax. But there has been few data for effectiveness of small-caliber catheterization in comparison with that of chest tube. In this study, we intended to observe the long-term effectiveness of 8 French catheter for the treatment of spontaneous pneumothoraces in comparison with that of chest tube thoracostomy. Method : From January, 1990 to January, 1996, sixty two patients with spontaneous pneumothoraces treated at Chung-Ang University Hospital were reviewed retrospectively. The patients were sub-divided into a group treated with 8 French catheter(n=23) and the other one with chest tube insertion(n=39). The clinical data were reviewed(age, sex, underlying pulmonary disorders, past history of pneumothorax, size of pneumothorax, follow-up period). And therapeutic effect of two groups was compared by treatment duration(duration of indwelling catheter or tube), treatment-associated complications and recurrence rate. Results : The follow-up period(median) of 8 French catheter group and chest tube group was 28 and 22 months, which had no statistical significance. Ther was no statistically significant difference of clinical characteristics between two groups with SP, PSP, SSP. The indwelling time of 8 French catheter group was $6.2{\pm}3.8$ days, which was significantly shorter than that of chest tube group in SP, $9.1{\pm}7.5$ days(p=0.047). In comparison of treatment-related complication in PSP, 8 French catheter group as 6.25% of complication showed lower tendency than the other group as 23.8% (p=0.041 ; one-tailed, p=0.053; two-tailed). The recurrence rate in each group of SP was 17.4%, 10.3%, which did not show any statistically significant difference. Conclusion : Treatment with 8 French catheter resulted in shorter indwelling time in sponteous pneumothorax, and lower incidence of treatment-related complication in primary spontaneous pneumothorax. And the recurrence rate in each of treatment group showed no statistically significant difference. So, we can recommend the 8 French small-caliber catheter for the initial therapy for spontaneous pneumothorax for the replacement of conventional chest tube thoracostomy. But further prospective study with more subjects of spontaneous pneumothorax will be needed for the evaluation of effectiveness of 8 French cateter.

  • PDF

Studies on the Hemodynamic Changes in Cirrhosis of the Liver (간경변증(肝硬變症)에서의 혈역학적(血力學的) 변화(變化)에 관(關)한 연구(硏究))

  • Kim, Jung-Il;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.11-27
    • /
    • 1970
  • Cardiac output, plasma volume and renal plasma flow were determined to evaluate hemodynamic changes in 29 patients with cirrhosis of the liver. The results obtained were as follows. 1. The mean plasma volume was 3793+895ml and it was significantly higher than the normal controls. The mean blood volume ($5266{\pm}1222ml$) and blood volume per kg body weight ($95.7{\pm}23.41ml$) were also increased significantly. The mean plasma volume per kg body weight ($69.1{\pm}19.1ml$) showed increased tendency and the mean difference between blood volume and plasma volume per kg body weight ($26.4{\pm}7.05ml$) was in lower limit of normal range. 2. The mean cardiac output was $7708{\pm}2652ml/min$ and it was significantly increased. The mean cardiac index ($4924{\pm}1998ml/min/M^2$), stroke volume ($96.2{\pm}34.2ml/beat$), stroke index ($62.3{\pm}27.34ml/M^2$) and fractional cardiac index ($1.54{\pm}0.577$) were also increased significantly. The mean total -peripheral resistance was $1664{\pm}753.8\;dynes\;sec\;cm^{-5}M^2$ and it was significantly lower than the normal controls. 3. The mean renal plasma flow was $537{\pm}146.8ml/min/1.73M^2$ and it was normal to decreased tendency. The mean endogenous creatinine clearance ($66.7{\pm}23.0ml/min/1.73M^2$) was significantly decreased. Filtration fraction was variable, but it was slightly lower than normal in most cases. The mean renal fraction of cardiac output ($11.4{\pm}6.27%$) was relatively decreased. 4. Although renal plasma flow was normal or decreased in general, it was definitely diminished in patients with creatinine clearance less than $60ml/min/1.73M^2$, resistant ascites, and signs of azotemia (elevated BUN and serum creatinine). 5. Diminished glomrular filtration rate with low filtration fraction and decreased renal fraction of cardiac output observed strongly supported increased renal afferent arteriolar resistance. 6. Renal circulatory impairment preceded azotemia or oroliguria in cirrhosis. 7. Clinical findigns and liver function were not correlated with hemodynamic changes, except for esophageal varices associated with high cardiac output obsedved. 8. No definite correlation of renal hemodynamics with plasma volume or cardiac output was found.

  • PDF

The Measurement of Blood Loss and Its Effect on Red Cell Survival Studies with $^{51}Cr$ (실혈(失血)이 적혈구수명(赤血球壽命) 측정(測定)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Lee, Mun-Ho;Lee, Jung-Sang;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.1
    • /
    • pp.27-36
    • /
    • 1970
  • 적혈구(赤血球) 수명의 측정에는 $^{51}Cr$-표지적혈구법(標識赤血球法)이 임상적(臨床的)으로 이용(利用)되고 있으며 이는 이론상(理論上) steady state 즉(卽) 측정기간(測定期間)동안 순환(循環) $^{51}Cr$량(量)-적혈구량(赤血球量)이 일정(一定)할 때에 한(限)하여 유효(有效)하며 unsteady state 때는 true red cell survival을 알기 위하여서는 측정치에 영향을 주는 요인(要因)에 대하여 각각(各各) 교정(校正)해 줄 필요(必要)가 있다. 이 요인(要因)중에 특히 실혈(失血)로 인(因)한 영향에 관(關)하여는 계통적인 연구(硏究)가 적다. 이에 저자(著者)들은 $^{51}Cr$표지적혈구법(標識赤血球法)을 이용(利用)하여 실혈(失血)이 적혈구(赤血球) 수명측정(測定)에 미치는 영향을 인체(人體)에서 실험 관찰하여 몇가지 성적을 얻었다. 연구대상(硏究對象)은 총(總) 56명(名)의 청장년(靑壯年)으로 급성실혈군(急性失血群)과 만성실혈군(慢性失血群)으로 구분(區分)하여 급성실혈군(急性失血群)은 위장출혈등(胃腸出血等)이 없는 2대(代)의 의대생(醫大生)으로 $^{51}Cr$표지적혈구법(標識赤血球法)을 사용하여 적혈구(赤血球) 수명을 측정하는 동안($10{\sim}14$ 일간(日間)) 1일당(日當) 10ml(6명(名)), 25ml(4명(名)), 50ml(4명(名)), 75ml(4명(名)), 100ml(6명(名))를 각각(各各) 사혈(瀉血)한 군(群)과 10일간(日間) 1,000ml를 사혈한 군(群) 즉 200ml씩 5회(回)(4명(名)), 500ml씩 2회(回)(4명(名))로 세분(細分)하였으며 만성실혈군(慢性失血群)은 직업적인 공혈자(供血者)로 반복사혈로 생긴 9명(名)의 빈혈자와 십이지장충증(十二指腸蟲症)에 감염(感染)되어 구충(驅蟲)한 중등도(中等度)의 철결핍성 빈혈환자 7명(名)으로 나누어 관찰하였다. 측정(測定) 방법(方法)으로는 Gray 및 Sterling법(法)을 개설한 방법(方法)으로 $^{51}Cr$표지적혈구(標識赤血球)의 계측시료(計測試料)로서 전혈(全血) 및 적혈구(赤血球)를 사용(使用)하였다. 실험(實驗)성적은 1. 1일당(日當) 실혈량(失血量)이 증가(增加)할수록 적혈구(赤血球)수명($T\frac{1}{2}$)은 짧아짐을 알 수 있었다. 즉(卽) 1일당(日當) $20{\sim}50ml$ 사혈군에서는 $T\frac{1}{2}$이 현저히 짧아지는 rapid phase을 나타내고 1일당(日當) 50ml이상(以上) 사혈군에서는 짧아지는 정도(程度)가 완만한 slow phase을 나타낸다(Fig. 6). 2. 1일량(日量) 10ml 및 25ml식(式) 사혈한 군(群)의 적혈구수명(赤血球壽命)을 측정(測定)하는데 있어 적혈구(赤血球)를 사용하였을 때에는 $T\frac{1}{2}$측 정치에 유의한 차(差)가 없었으며 이 범위 내에서는 Hct., Hb. 및 혈청철치(血淸鐵値)도 역시 유의한 차(差)가 없었다. 3. 1일량(日量) 50ml 및 75ml, 100ml씩 사혈한 군(群)에서는 적혈구(赤血球)만을 사용(使用)하였을 때와 전혈(全血)을 시료(試料)로 하였을 때 사이에 $T\frac{1}{2}$의 측정치에 유의한 차(差)가 있었으며 이 때는 Hct., Hb. 및 혈청철치(血淸鐵値)에도 변화(變化)가 있었다. 즉(卽), 전혈(全血)을 사용한 적혈구(赤血球) 수명($T\frac{1}{2}$)의 측정치가 적혈구(赤血球)만를 사용(使用)한 적혈구(赤血球) 수명($T\frac{1}{2}$)의 측정치 보다 짧았다. 4. 일정(一定)기간(10 일(日)) 사혈의 총량(1000ml)이 같을 매는 200ml를 5회(回) 사혈한 군(群)이나 500ml를 2회(回) 사혈한 군(群) 사이에 적혈구(赤血球) 수명($T\frac{1}{2}$)에 유의(有義)한 차(差)를 볼 수 없었다. 5. 직업적 공혈자의 반복사혈로 인(因)한 만성(慢性) 빈혈환자 9명(名)에서의 $^{51}Cr$적혈구(赤血球)수명($T\frac{1}{2}$) 측정치는 평균(平均) 19.2일(日)로 짧아져 있으나 적혈구수명측정전후(赤血球壽命測定前後)에 충분(充分)한 철제(鐵劑)를 투여(投與)하여 Hct., Hb. 및 혈청철치(血淸鐵値)를 증가(增加)시켰으며 이때 볼 수 있었든 Hct치(値)를 규준(規準)하여 교정한 적혈구(赤血球)수명($T\frac{1}{2}$)은 거의 정상(正常)범위 안에 있어(27.6일(日)) 이러한 인자(因子)를 고려하지 않으면 잘못 이해할 수가 있다. 6. 구충자충(鉤蟲仔蟲)을 구충한 7명(名)의 중등도(中等度) 철(鐵)결핍성 빈혈환자에서의 적혈구(赤血球)수명($T\frac{1}{2}$) 측정치는 25일(日)$\sim$31일(日)로 평균(平均) 28일(日)이었으며, 이때 장 출혈량은 1일(日) $1.0{\sim}3.5ml$이었다. 단시일내의 급성실혈시에는 이와같은 소량의 실혈(失血)도 적혈구(赤血球)수명($T\frac{1}{2}$) 측정치에 영향을 보여 줌을 알 수 있었다. 따라서 이러한 정도의 실혈은 실험오차에 기인하는 것인지 아니면 장기 출혈에서는 이러한 소량의 실혈이 적혈구(赤血球)수명($T\frac{1}{2}$) 측정에 영향을 미치지 않는 것인지는 아직 확실히 말할 수 없다. 8. $^{51}Cr$-표지적혈구(標識赤血球)로 측정한 적혈구(赤血球)수명($T\frac{1}{2}$)은 측정시의 실혈량(失血量)에 큰 영향을 받음을 알 수 있으며 저자(著者)들은 $^{51}Cr$표지적혈구(標識赤血球)를 이용(利用)한 적혈구(赤血球) 수명 측정때 검사기간중 실혈량이 적혈구수명치(赤血球壽命値)에 미치는 관계를 상술(上述)한 실험치(實驗値)를 기초(基礎)로 하여 다음과 같을 교정식(校正式)을 고찰(考察)해 보았다. $^{51}Cr\;T\frac{1}{2}=17.0e^{-0.0495}+18.4e^{-0.000924x}$ 단(但) X : 1일(日) 실혈량(失血量)(단위(單位) ml)

  • PDF