• Title/Summary/Keyword: Knee Arthroplasty

Search Result 158, Processing Time 0.03 seconds

The Analysis of Hospital Characteristics affecting Blood Transfusion to the patients under Knee or Hip Total Replacement Arthroplasty (슬관절과 고관절 전치환술 환자의 수혈에 영향을 미치는 병원특성 요인 분석)

  • Oh, Ji-Young;Kim, Sang-Mi;Lee, Seong-A
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4031-4039
    • /
    • 2015
  • The problems related with blood supply shortage and the stability of blood transfusion are on the rise, as it is expected that the blood doners will decrease but the blood use amount for aged population will increase, owing to low birth and aged population increase. The purpose of this study is to analyze the hospital characteristics which affect patients receiving and non-receiving blood transfusion for the knee and hip total replacement arthroplasty. Data were collected from Health Insurance Review and Assessment Service's 2011 sample data, and 5,370 inpatients were abstracted from them. Logistic regression analysis was performed, using SPSS 20. Independent variables used are hospital characteristics variables and patient characteristics variables. Hospital characteristics variables are hospital type, ownership, residence and the number of usable beds, and patient characteristics variables are gender, age, severity, type of anesthesia, main diagnosis, whether or not of anemia and insurance class. At the result of this study, it was found that hospital type, region, gender, age, severity, main diagnosis and whether or not of anemia were the factors that mostly affected the blood transfusion for knee arthroplasty. And hospital type, residence, gender, age, severity, type of anesthesia and whether of not of anemia were the factors that mostly affected the blood transfusion for hip arthroplasty. In addition to that, it is expected that this research which analyzed the present state of blood transfusion and its influence factors are cost effective, and would make a good use of preliminary data for good quality of medical service.

Changes in Korean Knee Score and Range of Motion after the Implementation of Structured Nursing Exercise Programs for Patients underwent Total Knee Arthroplasty: A Retrospective Study (슬관절 전치환술 환자를 위한 구조화된 운동교육 프로그램 후 한국형 슬관절 점수와 슬관절 운동범위 변화: 후향적 조사연구)

  • Park, Yu Ra;Park, Wanju
    • Journal of muscle and joint health
    • /
    • v.25 no.2
    • /
    • pp.61-74
    • /
    • 2018
  • Purpose: The purpose of this study was to examine the factors affecting changes in Korean Knee Score (KKS) and ranges of motion (ROM) of the knee after the structured exercise programs for the patients with total knee arthroplasty. Methods: This was a retrospective study using electronic medical records from January 2015 to February 2017, and the subject of this study was a total of 124 out of 434 patients underwent total knee replacement operation. They took part in a structured step-by-step exercise program conducted by orthopedic nurses, and then were evaluated for KKS and Knee ROM for 12 weeks after operation. Results: Post-intervention scores increased significantly in the KKS subdomains including pain and symptoms (t=-22.31, p<.001), function (t=-20.68, p<.001), evaluation of floor life (t=-14.18, p<.001), socioemotional function (t=-28.94, p<.001) over time. As for the change in the ROM, knee extension (t=9.23, p<.001) and knee flexion (t=4.04, p<.001) showed a statistically significant changes over time. Conclusion: This study illuminated the factors affecting the changes in pain and symptom, physical function, evaluation of floor life, socioemotional function and range of motion after structured exercise training programs for knee arthritis patients.

Safety of Temporary Use of Recycled Autoclaved Femoral Components in Infected Total Knee Arthroplasty: Confirming Sterility Using a Sonication Method

  • Park, Hyung-Jin;Kim, Hee-June;Kim, Shukho;Kim, Seong-Min;Mun, Jong-Uk;Kim, Jungmin;Kyung, Hee-Soo
    • Clinics in Orthopedic Surgery
    • /
    • v.10 no.4
    • /
    • pp.427-432
    • /
    • 2018
  • Background: The purpose of this study was to evaluate the usefulness of sonication technique for microbiological diagnosis and the sterility of the recycled autoclaved femoral components from infected total knee arthroplasty (TKA) using a sonication method. Methods: Nineteen femoral implants explanted from patients with infected TKA were sterilized with a standard autoclave method. Standard culture of the fluid before and after sonication of the sterilized implants was performed to detect pathogenic microorganisms. Additional experiments were performed to evaluate the sterility of the recycled implant by inducing artificial biofilm formation. Methicillin-resistant Staphylococcus aureus (MRSA) was inoculated into 10 implants and sterilization in a standard autoclave was performed, and then the fluid was cultured before and after sonication. Results: Two of the 19 sterilized implants were positive for growth of bacteria after sonication, whereas no growth was detected in the cultured fluid from the sterilized implants before sonication. The bacteria were Staphylococcus species in all two cases. In one of 10 implants inoculated with MRSA, the culture was positive for growth of bacteria both before and after sonication. However, Staphylococcus epidermidis was cultured from both occasions and thus this implant was thought to be contaminated. Conclusions: We found sonication for identification of pathogens could be helpful, but this finding should be interpreted carefully because of the possibility of contamination. Sterilization of an infected femoral implant with an autoclave method could be a good method for using the temporary articulating antibiotic spacer in two-stage revision arthroplasty.

The Comparison of Gait Analysis in Elderly Patients Before and After Total Knee Arthroplasty (노인의 무릎관절 전치환술에서 보행분석 비교)

  • Cho, Woon-Su;Kim, Sang-Yeong;Hwang, Tae-Yeon
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.2
    • /
    • pp.31-35
    • /
    • 2012
  • Purpose : The purpose of this study was to investigate the effect of kinematic variables by analysis of a gait in older. Methods : This study selected nine in older adults with osteoarthritis. The Kinematic variables during walk were compared analyzed using motion analysis. Results : The findings of this study are as follows. Stance time showed significant difference within-subject groups and interaction within-subjects and time. The swing and stride time showed a no significant interaction within-subjects and time. Swing time showed a no significant difference according to time and within-subjects. Stride time showed a significant difference according to time. But, stride time showed a no significant difference according to within-subjects. Conclusion : These findings of this study indicate that when the patients with total knee arthroplasty decreased stability. Therefore, stance and stride time showed increase when walking, because to decrease the weight bearing that is delivered to knee. And swing time showed decrease.

The Effect of Proprioceptive Neuromuscular Facilitation Exercise on the Range of Motion, Pain, and Functional Activity of Total Knee Arthroplasty Patients (고유수용성신경근촉진법 운동이 무릎관절 전치환술환자의 관절가동범위와 통증 및 기능적 활동에 미치는 영향)

  • Kim, Chang-Heon;Kang, Tae-Woo;Kim, Beom-Ryong
    • PNF and Movement
    • /
    • v.16 no.1
    • /
    • pp.75-83
    • /
    • 2018
  • Purpose: This study investigated the effects of proprioceptive neuromuscular facilitation (PNF) exercise on the range of motion (ROM), pain, and functional activity of patients who received total knee arthroplasty (TKA). The purpose of this study was to provide fundamental data regarding the use of PNF exercise among patients with musculoskeletal disease. Methods: Fourteen patients who received TKA were randomly divided into an experimental group (n=7) that took part in PNF exercise and a control group (n=7) that performed general rehabilitation exercise. Both groups performed the respective exercises for 30 minutes, five times a week for 2 weeks. For the measurement of ROM, the range of knee flexion was measured using a clinometer smartphone application. A visual analogue scale (VAS) was used for the measurement of the level of pain. The timed up and go test (TUG) was conducted to measure functional activity. A paired t-test was performed to compare within-group changes before and after the PNF exercise. Differences between the experimental group and control group were analyzed by an independent t-test. For all tests, the level of statistical significance was set at ${\alpha}=0.05$. Results: After the exercise, there was a significant within-group change in VAS and TUG scores in the experimental group and control group (p<0.01). There was also a significant between-group difference in VAS and TUG scores after the intervention (p<0.05). Conclusion: General rehabilitation exercise is commonly applied as a treatment for TKA patients and is relatively effective. The application of PNF exercise may be useful in such patients, considering its effects on ROM improvement, pain reduction, and functional enhancement.

A Comparison of Knee and Ankle Coronal Plane Alignment According to Quadriceps Exercise Method in Early Phase of Total Knee Arthroplasty: Lower Extremity Isometric Co-Contraction and Quadriceps Isolated Isometric Contraction (슬관절 전치환술 초기의 대퇴사두근 운동 방법에 따른 슬관절과 족관절의 관상면 정렬 비교: 하지 등척성 동시수축과 대퇴사두근 단독 등척성 수축)

  • Kim, Hyung-soo;Jeong, Young-hee
    • Physical Therapy Korea
    • /
    • v.23 no.1
    • /
    • pp.20-30
    • /
    • 2016
  • Background: Total knee arthroplasty (TKA) recovers the alignment of the knee joint, but fails to automatically restore the alignment and function of the hip and ankle joints. It may affect the alignment and stability of the knee joint, therefore therapeutic intervention in hip and ankle joint is necessary for the rehabilitation process after TKA. Objects: The aim of this study was to comparison of the effects of the two exercise methods on the coronal plane alignment after TKA. This study conducted an experiment by dividing subjects into a lower extremity isometric co-contraction group (LEIC) and a quadriceps isolated isometric contraction (QIIC) group. Methods: A total of 37 subjects were randomly assigned to the LEIC ($n_1$=19) or the QIIC ($n_2$=18). Exercise was applied to five times per week for three weeks, starting on the eighth day after surgery. Range of motion exercises were performed as a common intervention and then each group performed quadriceps isometric contraction exercises with 10 sets of 5 repetitions. Radiological imaging was performed prior to surgery, one month and six months after surgery. In addition, the hip-knee-ankle angle (HKA) and tibiotalar angle (TTA) were measured. Results: The HKA was close to neutral in the LEIC rather than the QIIC (p<.05). The LEIC showed varus and the QIIC exhibited valgus TTA (p<.05). In a comparison of HKA and TTA over time, there was no significant change in either group (p>.05). According to the comparison of the TTA before surgery, the LEIC showed significant changes in the varus direction (p<.05), while there was no significant change in the QIIC (p>.05). Conclusion: The LEIC method triggered changes in the TTA and brought the HKA close to the neutral. Thus, LEIC is more effective than QIIC in creating stability in the coronal plane alignment of the knee and ankle joints after TKA.

Comparison of Clinical Results and Risk of Patellar Injury between Attune and PFC Sigma Knee Systems

  • Song, Sang Jun;Kang, Se Gu;Park, Cheol Hee;Bae, Dae Kyung
    • Knee surgery & related research
    • /
    • v.30 no.4
    • /
    • pp.334-340
    • /
    • 2018
  • Purpose: The purposes of this study were to compare clinical results after total knee arthroplasty (TKA) using the Attune and PFC Sigma knee designs and to investigate whether the use of the Attune prosthesis increased the risk of patellar injury in Asian patients. Materials and Methods: Three hundred knees that underwent TKA using Attune (group A) were compared to 300 knees that underwent TKA using PFC Sigma (group B). The Knee Society Knee Score (KS) and Function Score (FS), and range of motion (ROM) were compared. The residual patellar thickness was compared to evaluate the risk of patellar injury. Results: The postoperative KS and ROM of group A were better than those of group B (93.1 vs. 88.8, p<0.001 and $131.4^{\circ}$ vs. $129.0^{\circ}$, p=0.008, respectively). The postoperative FS did not differ significantly between the two groups (80.9 vs. 78.7, p=0.427). The residual patella was thinner in group A (14.8 mm vs. 15.7 mm, p=0.003), which made up a higher proportion of the high-risk group for patellar fractures with a residual thickness of <12 mm (7.5% vs. 2.1%, p=0.003). Conclusions: TKA using the Attune prosthesis provided more favorable clinical results than TKA using PFC Sigma. However, the risk of injury in the residual patella was increased with use of the Attune prosthesis in Asian patients.

May-Thurner Syndrome with Deep Vein Trombosis after Total Knee Arthroplasty (인공 슬관절 전치환술 후 발생한 메이-터너 증후군 및 심부정맥 혈전증)

  • Lee, Hwa-Sung;Kim, Yong-Woo;Jung, Se-Hoon;Lee, Se-Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.343-347
    • /
    • 2020
  • May-Thurner syndrome (MTS), also known as iliac vein compression syndrome, is a condition, in which compression of the common venous outflow tract of the left lower extremity can cause discomfort, swelling, pain or blood clots in the iliofemoral veins. The problem is due to left common iliac vein compression by the overlying right common iliac artery. This paper describes the case of a 75-year-old female with MTS after performing right total knee replacement arthroplasty. The authors diagnosed MTS through intravenous angiography and angiographic computed tomography on swelling and pain of the left lower extremities after performing right total knee replacement arthroplasty. The thrombus was removed using a thrombolytic agent and mechanical thrombectomy, and an intravenous stent then inserted after angioplasty. No case of MTS after performing total knee replacement arthroplasty has been reported in Korea. Therefore, this case is reported along with review of the relevant literature.

Comparison of the Quality of Various Polychromatic and Monochromatic Dual-Energy CT Images with or without a Metal Artifact Reduction Algorithm to Evaluate Total Knee Arthroplasty

  • Hye Jung Choo;Sun Joo Lee;Dong Wook Kim;Yoo Jin Lee;Jin Wook Baek;Ji-yeon Han;Young Jin Heo
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1341-1351
    • /
    • 2021
  • Objective: To compare the quality of various polychromatic and monochromatic images with or without using an iterative metal artifact reduction algorithm (iMAR) obtained from a dual-energy computed tomography (CT) to evaluate total knee arthroplasty. Materials and Methods: We included 58 patients (28 male and 30 female; mean age [range], 71.4 [61-83] years) who underwent 74 knee examinations after total knee arthroplasty using dual-energy CT. CT image sets consisted of polychromatic image sets that linearly blended 80 kVp and tin-filtered 140 kVp using weighting factors of 0.4, 0, and -0.3, and monochromatic images at 130, 150, 170, and 190 keV. These image sets were obtained with and without applying iMAR, creating a total of 14 image sets. Two readers qualitatively ranked the image quality (1 [lowest quality] through 14 [highest quality]). Volumes of high- and low-density artifacts and contrast-to-noise ratios (CNRs) between the bone and fat tissue were quantitatively measured in a subset of 25 knees unaffected by metal artifacts. Results: iMAR-applied, polychromatic images using weighting factors of -0.3 and 0.0 (P-0.3i and P0.0i, respectively) showed the highest image-quality rank scores (median of 14 for both by one reader and 13 and 14, respectively, by the other reader; p < 0.001). All iMAR-applied image series showed higher rank scores than the iMAR-unapplied ones. The smallest volumes of low-density artifacts were found in P-0.3i, P0.0i, and iMAR-applied monochromatic images at 130 keV. The smallest volumes of high-density artifacts were noted in P-0.3i. The CNRs were best in polychromatic images using a weighting factor of 0.4 with or without iMAR application, followed by polychromatic images using a weighting factor of 0.0 with or without iMAR application. Conclusion: Polychromatic images combined with iMAR application, P-0.3i and P0.0i, provided better image qualities and substantial metal artifact reduction compared with other image sets.