• Title/Summary/Keyword: Kitchen hood

Search Result 40, Processing Time 0.021 seconds

Survey on the Ratio of Kitchen to Total Space and Ventilation System Capacity of Kitchens through Case Studies in Korean Foods Restaurants (사례 조사를 통한 한식 음식점의 주방면적 비율과 환기시설의 적정성 조사)

  • Chang, Hyeja;Choi, Gyunggi;Wang, Taehwan;Kwak, Tongkyung
    • Korean journal of food and cookery science
    • /
    • v.31 no.1
    • /
    • pp.33-40
    • /
    • 2015
  • For the globalization of Korean food restaurants, the kitchens should be equipped with proper ventilation systems and space to keep clean and ensure food safety. This study aimed to examine the ratio of kitchen to total space of restaurant and the suitability of the ventilation systems employed at Korean food restaurants. Data were collected by on-site survey of 12 Korean foods restaurants in Seoul. Length and width of the restaurants were measured with scale. Temperatures and air velocity around the heating equipment, working area, and hood were measured with a thermal imaging camera anemometer and thermometer. Statistical analyses were conducted with the SPSS program. The average space of the restaurants was $25.7m^2$. The ratio of kitchen to space was 0.22 for restaurants sized $32m^2$, 0.28 for $33-66m^2$, 0.21 for $66.1-99m^2$, 0.16 for $99.1-148.5m^2$, and 0.35 for those above $148.5m^2$. Average maximum and minimum air velocity around the hood were 0.28 m/sec and 0.22 m/sec, respectively. Under these conditions, the temperature of the working area was $41^{\circ}C$, presenting an uncomfortable indoor temperature for kitchen employees to work. When classifying 3 groups based on the minimum and maximum air velocity, the temperatures near the cooking area and in the hood of the restaurants showed significant differences among the three groups. When the maximum air velocity was over 0.3 m/sec, the temperature of the cooking area was as $30.1^{\circ}C$, showing a significantly lower temperature (p<0.01). Based on these results, the kitchen space rate of 0.25 to the total space and a ventilation system maintaining a maximum air velocity over 0.3 m/sec were recommended for ensuring the food safety of Korean foods restaurants sized 66 to $99m^2$.

Noise Characteristics of Improved Sirocco Fan for Range Hood (렌지 후드 용 개선된 시로코 홴의 소음특성 변화)

  • Kim, Cheol-Ho;Choi, Young-Seok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.209-212
    • /
    • 2005
  • Recently, since structures have become extremely airtight with the development of high-rise apartments, mixed use residential and commercial buildings and offices, large capacity range hoods have become commonly implemented. However, the high noise level caused by this range hood system made of thin plate is the cause of increased complaints among users. In this study, the level of noise emitted from this type of range hood was measured by height at the user's location in the kitchen. It was confirmed that a great deal of noise was emitted in the downward direction of the hood. In order to minimize the noise emitted from this type of range hood, a new type of fan was manufactured. This was done by changing only the material and shape of the fan, since it was determined to be the primary source of noise emission. Then a comparison and evaluation were carried out regarding the noise characteristics between the new type of fan and the existing type of fan. As a result, it was confirmed that the noise from the new fan was reduced by more than 2 dB compared to the existing fan without noise interference at the discharge end.

  • PDF

A Basic Study on the Utilization of Kitchen and Bathroom Exhaust Wind Velocity in High-Rise Apartment (초고층 공동주택의 주방.욕실 배기풍속 활용을 위한 기초연구)

  • Kim, Seong-Yong;Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.226-231
    • /
    • 2011
  • This study set out to review the air current fluidity in exhaust common ducts by installing an inlet pipe at a leisure space in the PS(Pipe Shaft)room for the sake of wind power generation with kitchen and bathroom exhaust common ducts of all the equipment and air conditioning shafts in high-rise apartment. The air current functionality of kitchen and bathroom exhaust common ducts was reviewed by analyzing wind velocity changes according to changes to the area of exhaust common ducts through a simulation, changes to the wind velocity of the kitchen hood by applying an external inlet pipe, changes to the usage factor of exhaust common ducts, and changes to wind velocity by altering the form of the ventilator at the bottom of the old exhaust common duct. It was a basic study on the utilization of exhaust wind velocity in exhaust common ducts.

  • PDF

Prediction of the ventilation performance in a kitchen with various locations of gas range and window (가스렌지와 창문위치에 따른 주방 배기성능 예측)

  • 김경환;이재헌;박명식;이대우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.75-82
    • /
    • 2000
  • This paper presents the predicted results by CFD technique of air flow and contaminant distribution in a full-scale kitchen opened to a living room, ventilated by a exhaust hood. To analyze the characteristics of the indoor environment, the concept of contaminant index was defined. In this study, the locations of the gas range and the window were chosen as the parameters to investigate the indoor environment. The values of the contaminant index for several layout of the gas range and the window were calculated and compared. When the gas range is installed along the wall with specified window location, its position in relation to the wall has unnoticed effect on contaminant infer. Once the location of the gas range is fixed, the indoor air quality may deteriorate by the proximity of the window to the gas range. This is due to the shorter distance that external fresh air must travel within the kitchen before it reaches the exhaust fan.

  • PDF

Effect of Slot Discharge-Angle Change on Exhaust Efficiency of Range Hood System with Air Curtain (에어커튼형 레인지후드의 슬롯 토출 각도 변화와 배기 효율)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.468-474
    • /
    • 2015
  • When oil is used for cooking in detached or apartment houses, large amounts of oil-mist, smoke, and particulate substances are generated and dispersed into the indoor-air environment. These pollutants diffuse into the surroundings and spread their odor while rising fast at a high temperature due to the heat energy from the gas range. Although the exhaust gas is discharged from the exhaust hood, which is installed on the top of a gas range to remove the diffuse pollutants, the exhaust conditions can vary greatly because they depend on the shape of the exhaust hood and the discharge rate. In this paper, the air that is required for the gas-exhaustion process is supplied by an air curtain that surrounds the kitchen hood, and the pollutant-capturing efficiency varies depending on the angle of the discharge grills; the pollutant-capturing efficiency was studied using a numerical-analysis method. The results indicate that the pollutant-capturing efficiency is not significantly changed by a change of the discharge-grill angle at a low air-discharge rate; however, at a high air-discharge rate, the efficiency value increases with an increase of the discharge-grill angle, whereby the best value occurs at 30 degrees and the efficiency decreases above this angle. Below 30 degrees, the effect of the discharge rate on the capturing efficiency is more than that of the discharge-grill angle.

Numerical Study on the Effect of Range Surrounding Environment on Detecting Time for Cooking Oil Fire in Kitchen (주방내 조리용 기름 화재 발생시 레인지 주변 환경이 감지 시간에 미치는 영향에 대한 수치해석적 연구)

  • Lee, Jin-Woo;Ko, Gwon-Hyun;Ryou, Hong-Sun;Jang, Yong-Jun;Jung, Woo-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.134-139
    • /
    • 2010
  • According to the "Yearbook of disaster response, fire safety and fire statistics (NEMA: National Emergency Management Agency)", approximately 34% of all fire is interior fire such as hotel, restaurant and residence and more than 53% of which is occurring in the kitchen. The evaluation of fire extinguishing system in the kitchen is performed in accordance with the "Korea Fire Equipment Inspection Standard (KOFEIS 0101-1)" which is using one environmental condition. However, only using one environmental condition is not enough to evaluate the performance of the automatic fire extinguisher in kitchen fire. So the study of fire detecting characteristic about various environmental condition needs. In this study, the numerical analysis is carried out about detecting time characteristic for various range's surrounding environment. As a result, it showed up to 100 s difference in the detection time depending on the position of the range. And detecting time also showed difference for on-off hood operation. From this results, it can be verify and improve the evaluation standard for the fire extinguishing system in kitchen fire.

Correlation Analysis of Parameters affecting Pressure Distributions in Vertical Shafts by Design of Experiments (실험계획법에 의한 수직샤프트내 압력분포에 영향을 미치는 인자간 상관관계 분석)

  • Han, Hwa-Taik;Shin, Chul-Yong
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.883-888
    • /
    • 2008
  • Various effluents generated in cooking processes contribute a great deal to indoor air pollution among many other indoor pollutants such as dusts from outdoor and carbon dioxide from human body. Kitchen exhaust hoods are not believed to exhaust indoor contaminants properly in many cases, while generating too much noise. Instead of focusing on individual products of kitchen hoods, we should address the problem by attacking the ventilation system as a whole including vertical shafts and building air-tightness. In this study, it is intended to investigate the pressure distribution along the vertical shaft depending on various system parameters, such as shaft size, concurrent hood usage rate, roof fan, inlet pressure loss, and outdoor temperature. The maximum static pressure in the vertical shaft has been obtained using the method of design of experiments and analyzed by the analysis of variance. The results can be used for the design of kitchen exhaust systems by analyzing the pressure distributions in vertical shafts.

  • PDF