• Title/Summary/Keyword: Kit preparation

Search Result 45, Processing Time 0.027 seconds

Development of Freeze-Dried DOTMP Kits for Labeling with 68Ga

  • Lim, Jae Cheong;Choi, Sang Mu;Cho, Eun Ha;Lee, So Young;Dho, So Hee;Kim, Soo Yong
    • Journal of Radiation Industry
    • /
    • v.9 no.2
    • /
    • pp.63-68
    • /
    • 2015
  • Lyophilized DOTMP kits were prepared using DOTMP, ammonium acetate, and ascorbic acid. The $^{68}Ga$-DOTMP was prepared by incubating the kit dissolved in 0.5 ml of concentrated $^{68}Ga$ using NaCl method and 0.5 ml of DDW, at $100^{\circ}C$ for 7 min. The labeling yield was evaluated by two solvent systems of TLC. 1 MBq of concentrated $^{68}Ga$ was labeled with $0.8{\mu}g$ of DOTMP by high radiolabeling yield (>98%), which was determined by two TLC methods. The composition of the prepared freeze-dried vial is $400{\mu}g$ of DOTMP, 19.27 mg of ammonium acetate and 17.62 mg of ascorbic acid. ~555 MBq of $^{68}Ga$-DOTMP was prepared with excellent radiochemical purity (>98%) and it was stable for 4 hr at room temperature. In conclusion, Freeze-dried DOTMP kits for the convenient preparation of $^{68}Ga$-DOTMP have been developed. Availability of this kit is expected to stimulate the widespread use of $^{68}Ga$-DOTMP in the fields of nuclear medicine.

The Medical Supplies KIT Design based on the Intravenous Fluid Therapy for Experience of Medical Staff (의료인의 의료 행위 경험을 위한 정맥 수액 요법용 의료 소모품 키트 디자인)

  • Lee, Hye-Min;Pan, Young-Hwan
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.8
    • /
    • pp.121-128
    • /
    • 2019
  • Medical services should be provided not only to patients but also to medical staff who are the main actors of medical treatment. This paper is based on Ethnography, observing the behavior of medical staff performing medical actions and finding what is the most frequent of physical medical treatment. In particular, I observed the need for recognition and performance of the clinical workforce for invasive medical treatment. Based on the Insight from the observation and analysis of medical staff's behavior on intravenous fluid therapy and in-depth interview, I defined four design value factors. Plus, I suggest a design prototype with a proposal for designing a medical consumable kit for intravenous fluid therapy to validate the design elements. Kitting medical consumables simplify the preparation and disposal process throughout the treatment, enabling rapid medical action and increasing work efficiency.

Establishment of Complex Disaster Scenario on the Utility Tunnel Study for Digital Twin System Application (디지털트윈 시스템 적용을 위한 공동구 복합재난 시나리오 구축)

  • Yon Ha Chung; So Dam Kim;Hyun Jeong Seo;Hojun Lee;Tae Jung Song
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.4
    • /
    • pp.861-872
    • /
    • 2022
  • The purpose of this study was to establish a complex disaster scenario that can comprehensively consider various disaster situations that may occur in the utility tunnel. Method: In order to comprehensively consider the correlation between disasters, a composite disaster scenario was derived from a combination of damage factors, respectively. A risk assessment was performed in order to derive the priorities of the scenarios. And based on the results, the priorities of complex disaster scenarios were set. Result: Based on the disaster cases in the utility tunnel, a plan was prepared for complex disaster scenarios centered on damage. A complex disaster scenario was specified using a semi-quantitative evaluation method for single and multiple disaster factors such as fire, flooding, and earthquake. Conclusion: The composite disaster scenario derived from this study can be used for the prevention and preparation of damage when the precursor symptoms of a disaster are detected. In addition, the results of this study are expected to be used as basic data for preparing strategic plans and preparing complex disaster response technologies to induce rapid response and recovery in case of emergency disasters.

Analysis of Orbital Lifetime Prediction Parameters in Preparation for Post-Mission Disposal

  • Choi, Ha-Yeon;Kim, Hae-Dong;Seong, Jae-Dong
    • Journal of Astronomy and Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.367-377
    • /
    • 2015
  • Atmospheric drag force is an important source of perturbation of Low Earth Orbit (LEO) orbit satellites, and solar activity is a major factor for changes in atmospheric density. In particular, the orbital lifetime of a satellite varies with changes in solar activity, so care must be taken in predicting the remaining orbital lifetime during preparation for post-mission disposal. In this paper, the System Tool Kit (STK$^{(R)}$) Long-term Orbit Propagator is used to analyze the changes in orbital lifetime predictions with respect to solar activity. In addition, the STK$^{(R)}$ Lifetime tool is used to analyze the change in orbital lifetime with respect to solar flux data generation, which is needed for the orbital lifetime calculation, and its control on the drag coefficient control. Analysis showed that the application of the most recent solar flux file within the Lifetime tool gives a predicted trend that is closest to the actual orbit. We also examine the effect of the drag coefficient, by performing a comparative analysis between varying and constant coefficients in terms of solar activity intensities.

Kit Preparation and Biodistribution of $Bz-MAG_3$ (benzoylmercaptoacetylglycylglycylglycine) for Renal Imaging (신장기능영상용 방사성의 약품 $Bz-MAG_3$(Benzoylmercaptoacetylglycylglycylglycine) 의 키트화 및 체내분포)

  • Kim, Young-Ju;Jeong, Jae-Min;Cho, Jung-Hyuk;Chang, Young-Soo;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.367-371
    • /
    • 1996
  • The $MAG_3$ is a tubular excreting radiopharmaceutical for renal image. We synthesized benzoyl $MAG_3\;(Bz-MAG_3)$ and made a kit for labeling with $^{99m}Tc$. We checked the labeling efficieny of $^{99m}Tc$ labeled $MAG_3$ and biodistribution. Labeling efficieny was checked by TLC-SG (acetonitrile/$H_2O$=2/1). After injecting of 1 mCi of $^{99m}Tc-MAG_3$ to ICR-mice, $T_{max}(min),\;T_{1/2}(min)$ were obtained in the renogram. Sequential images (30sec, 2min, 5min, 10min, 15min, 20min) of $^{99m}Tc-MAG_3$ were compared with those of commercial $^{99m}Tc$-DTPA (Du Pont Merck Pharmaceutical Co.) kit. 1) The $R_f$ value of synthesized $^{99m}Tc-MAG_3$ was 0.78 and labeling efficiency was $97.5{\pm}1.9%$ (n=10). 2) The dynamic images of the $^{99m}Tc-MAG_3$ were better than those of the $^{99m}Tc$-DTPA. 3) The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc-MAG_3$ (n=10) were $1.5{\pm}0.5$ (left), $1.4{\pm}0.4$ (right), and $4.3{\pm}1.4$ (left), $4.8{\pm}2.0$ (right), respectively. The $T_{max}(min.)$ and $T_{1/2}(min.)$ of $^{99m}Tc$-DTPA (n=7) were $2.7{\pm}1.6$ (left), $2.7{\pm}1.6$ (right), and $3.8{\pm}1.7$ (left), $4.5{\pm}2.7$ (right), respectively. The quaility of image and labeling efficiency of the synthesized $Bz-MAG_3$ kit were excellent, that it was supposed to be used in routine clinical work.

  • PDF

Methylene Blue-stained Interstitial Cells are Electrically Active in the Myenteric Board Freshly Prepared from the Murine Small Intestine

  • Lee, Kyu-Pil;Jeon, Ju-Hong;So, In-Suk;Kim, Ki-Whan
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.10 no.4
    • /
    • pp.193-198
    • /
    • 2006
  • Many gastrointestinal muscles show electrical oscillation, so-called 'slow wave', originated from interstitial cells of Cajal (ICCs). Thus, a technique to freshly isolate the cells is indispensable to explore the electrophysiological properties of the ICCs. To apply an enzyme solution on the serosal surface for cell isolation, the intestine was inverted and 0.02% trypsin solution and 0.04% collagenase solution were applied to serosal cavity. After the enzyme treatment, mucosal layer was removed and longitudinal muscle layer was gently separated from the rest of tissue. The thin layer was stretched in the recording chamber and mounted on an inverted microscope. Using ${\beta}-escine$, perforated whole cell patch clamp technique was used. Under a microscope, the tissue showed smooth muscle cells and interstitial cells around the myenteric plexus. Under voltage clamp condition, three types of membrane potential were recorded. One group of interstitial cells, which were positive to methylene blue and CD34, showed spontaneous outward current. These cells had bipolar shape and were considered as fibroblast-like cells because of their peculiar shape and arrangement. Another group, positive to c-kit and methylene blue, showed spontaneous inward current. These cells had more rounded shape and processes and were considered as ICCs. The third, positive to c-kit and had granules containing methylene blue, showed quiet membrane potentials under the voltage-clamp mode. These cells appeared to be resident macrophages. Therefore, in the freshly isolated thin tissue preparation, methylene blue could easily identify three types of cells rather than morphological properties. Using this method, we were able to study electrical properties of fibroblast and residential macrophage as well as myenteric ICCs.

Preparation of Monoclonal Antibodies for Canine Trypsin-Like Immunoreactivity (개 트립신양(樣) 면역반응성 단클론 항체의 제작)

  • Kim, Sung-Soo;Kang, Ji-Houn;Cheong, Kwang-Myun;Yoo, Jai-Cheol;Chong, Chom-Kyu;Yang, Mhan-Pyo
    • Journal of Veterinary Clinics
    • /
    • v.25 no.5
    • /
    • pp.317-323
    • /
    • 2008
  • Canine trypsin-like immunoreactivity (cTLI), which is a mirror of the concentration of trypsin and trypsinogen, is a pancreas-specific enzyme and a suitable marker for canine pancreatitis and especially exocrine pancreatic insufficiency (EPI). To develop the immunochromatographic test kit, monoclonal antibodies that recognize cTLI were prepared. Anionic trypsin, cationic trypsin, and chymotrypsin from canine pancreas were successfully purified to homogeneity, using ammonium sulfate fractionation and benzamidine-affinity chromatography. The purification fold for anionic trypsin was 108 times when compared with that of the homogenation of pancreas. The molecular weights by SDS-PAGE analysis were approximately 23 kDa for chymotrypsin and approximately 20 kDa for cationic trypsin and anionic trypsin, respectively. Using the purified trypsin-like proteins, ten hybridomas which secret canine trypsin-specific monoclonal antibody were prepared. Klotz plot indicated that hybridomas, 5G2H10G4 and 2F4A11, have high affinity constant (Ka) of $4.1\;{\times}\;10^{9}$ and $1.8\;{\times}\;10^{9}$, respectively. Especially, 5F9H3 showed the cationic typsin-specific binding pattern and its Ka was determined to $4.5\;{\times}\;10^{9}$. The development of immunochromatographic test kit using these monoclonal antibodies against cTLI will be very useful in the diagnosis of canine EPI or canine pancreatitis.

Comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit for the removal of separated endodontic instruments

  • Pruthi, Preeti Jain;Nawal, Ruchika Roongta;Talwar, Sangeeta;Verma, Mahesh
    • Restorative Dentistry and Endodontics
    • /
    • v.45 no.2
    • /
    • pp.14.1-14.7
    • /
    • 2020
  • Objective: The aim of this study was to perform a comparative evaluation of the effectiveness of ultrasonic tips versus the Terauchi file retrieval kit (TFRK) for the removal of broken endodontic instruments. Materials and Methods: A total of 80 extracted human first mandibular molars with moderate root canal curvature were selected. Following access cavity preparation canal patency was established with a size 10/15 K-file in the mesiobuccal canals of all teeth. The teeth were divided into 2 groups of 40 teeth each: the P group (ProUltra tips) and the T group (TFRK). Each group was further subdivided into 2 smaller groups of 20 teeth each according to whether ProTaper F1 rotary instruments were fractured in either the coronal third (C constituting the PC and TC groups) or the middle third (M constituting the PM and TM groups). Instrument retrieval was performed using either ProUltra tips or the TFRK. Results: The overall success rate at removing the separated instrument was 90% in group P and 95% in group T (p > 0.05) The mean time for instrument removal was higher with the ultrasonic tips than with the TFRK (p > 0.05). Conclusion: Both systems are acceptable clinical tools for instrument retrieval but the loop device in the TFRK requires slightly more dexterity than is needed for the ProUltra tips.

Studies on Preparation of $^{131}I$ Labelled m-Iodobenzylguanidine $(^{131}I-MIBG)$ for Adrenomedullary Imaging (부신수실 영상용 $^{131}I$ 표지 메타요오도벤질구아니딘 $(^{131}I-MIBC)$의 제조에 관한 연구)

  • Park, Kyung-Bae;Awh, Ok-Doo;Kim, Jae-Rok
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.101-107
    • /
    • 1990
  • To develop $^{131}I-labelled$ m-iodobeneylguanidine $(^{131}I-MIBG)$, various experiments such as synthesis of MIBG, establishment of labelling conditions, determination of radiochemical purity, and examination of stability were carried out. 1) m-Iodobenzylguanidine (MIBG) sulfate was synthesized with a total yield of 62.4% by the condensation of m-iodobenzylamine hydrochloride with cyanamide via MIBG bicarbonate. Its physical properties, IR, $^1H-NMR$, and elemental analysis data were nearly identical to those of literature. 2) Freeze-dried or vacuum-dried kit vials were prepared from the mixture so as to contain MIBG (2 mg), ascorbic acid (10 mg), copper (II) sulfate (0.14 mg), and tin (II) sulfate (0.5 mg) per vial. Copper ( I ) catalyzed radioiodination of MIBG was carried out using kit vials and 0.01 M $H_2SO_4$ as solvent at $100^{\circ}C$ for 30 min under nitrogen atmosphere (optimal conditions). Labelling yield was 98% and radiochemical purity was 99.5%, respectively. 3) Solid-phase radioiodination of MIBG was carried out at $155^{\circ}C$ for 30 min using the prepared vials to contain MIBG (2 mg) and ammonium sulfate (10 mg). Duplicate reactions under the same conditions showed labelling yield of 95% and radiochemical purity of 99.5%. 4) $^{131}I-MIBG$ prepared either by catalytic or by solid-phase exchange method showed radio-chemical purity of 99% even after 3 days storing at room temperature.

  • PDF

A Survey of Need and Purchase Intention for Meal Kits - For Children's Foodservice Managers in Changwon Areas - (어린이급식소용 밀키트 필요성 및 구매의도에 대한 인식 조사 - 창원 일부 지역의 어린이 급식담당자 대상 -)

  • Seo-Jin Kim;Jae-Hee Park;Hye-Kyung Moon
    • Journal of the Korean Dietetic Association
    • /
    • v.29 no.3
    • /
    • pp.123-139
    • /
    • 2023
  • In this study, a survey was conducted on the development of meal kits for children's foodservice to increase the convenience of the cooking process. It was performed among the foodservice managers in the 141 children's foodservice facilities registered in the Center for Children's Foodservice Management about meal-kits in Changwon areas. The survey results were analyzed according to the children's foodservice scale type. The biggest problem in a foodservice system was "difficult to purchase food ingredients directly every week" (38.4%) in small-scale children's foodservices, and "difficult to use the served menu without modification" (38.2%) in institutional children's foodservices (P<0.001). The most important factor when choosing the meal kit was "quality" (41.1%). Respondents on having an experience with using the meal kit were low at 34.8%, and the reasons for not using the meal kits were "expensive" (67.3%) and "not fresh food ingredients" (18.4%). The main reasons for not using children's foodservice meal kits were "expensiveness" (64.4%) and "necessity of adding disinfection process" (16.1%). Most of the reasons for not wanting to use children's foodservice meal kits were that they did not trust the safety of the meal kits. The use of meal kits in children's foodservices may reduce the preparation process and increase the efficiency of foodservice although the safety and quality of meal kits should be guaranteed. The appropriate hygiene management standards need to be set, and HACCP should be applied to develop meal kits for children's foodservices.