• Title/Summary/Keyword: Kirschner

Search Result 58, Processing Time 0.057 seconds

Removal of Kirschner Wire That Migrated from the Pelvic Bone into the Right Ventricle of the Heart

  • Kim, Ji-Eon;Jung, Sung-Ho;Cho, Won-Chul;Byun, Joung-Hun
    • Journal of Chest Surgery
    • /
    • v.44 no.3
    • /
    • pp.250-252
    • /
    • 2011
  • A sixty-year-old man was admitted due to chest pain. He had a history of pelvic bone fracture fixation with Kirschner wire about 20 years earlier. On examination, we detected a Kirschner wire that had migrated into the right ventricle. Without cardiopulmonary bypass, we removed the migrating Kirschner wire via median sternotomy. The patient recovered without complications and was discharged on the 5th postoperative day.

The Surgical Treatment of Type V Acute Acromioclavicular Joint Dislocation Using Suture Anchor and Kirschner Wire (봉합 나사못과 Kirschner 강선을 이용한 제 5형 급성 견봉 쇄골 관절 탈구의 수술적 치료)

  • Jung, Gu-Hee;Cho, Chyul-Hyun;Jang, Su-Jin;Jang, Jae-Ho;Kim, Jae-Do
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.217-222
    • /
    • 2010
  • Purpose: We wanted to evaluate the clinical outcomes after operative treatment using two suture anchors and Kirschner wire for treating acute Rockwood type V acromioclavicular joint dislocation Materials and Methods: Between May 2006 and May 2009, 10 patients underwent surgical treatment for acute Rockwood type V acromioclavicular joint dislocation using two suture anchors and Kirschner wire and they were followed for a mean of 12.0 (range: 7-31) months. We analyzed the functional results by the Korean shoulder score, the Constant-Murley score and the reduction state of the acromioclavicular joint at the last follow-up. Results: All the cases achieved a satisfactory outcome. The mean Korean shoulder score was 89.9 (range: 81-100) points and the mean Constant-Murley score was 87.8 (range: 82-93) points. According to the radiologic findings, 8 patients achieved anatomical reduction of the acromioclavicular joint: there was a slight loss of reduction in one patient and a partial loss of reduction in one patient. None of the patients had deep infection or re-dislocation. Conclusion: The operative treatment using two suture anchors and Kirschner wire may be used for acute Rockwood type V acromioclavicular joint dislocation, and it has an advantage in that it can prevent chondral injury of the joint.

INTRAORAL OPEN REDUCTION OF MANDIBULAR SUBCONDYLAR FRACTURES USING KIRSCHNER WIRE (Kirschner wire를 사용한 과두하 골절의 구강내 접근법)

  • Kim, Seong-Il;Kim, Seung-Ryong;Baik, Jin-Ah;Ko, Seung-O;Shin, Hyo-Keun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.3
    • /
    • pp.270-276
    • /
    • 2001
  • The treatment of mandibular subcondylar fractures is a matter of controversy. The majority of mandibular subcondylar fracture are treated by closed reduction, but the displaced or dislocated mandibular subcondylar fractures may be treated by open reduction. The characteristics of open reduction are the anatomical reduction, the functional restoration, the rapid function, the maintenance of vertical ramus dimension, the better appearance and the less resultant TMJ problem etc. When an open reduction is considered, the wire, miniplate, lag screw and Kirschner wire are available with internal fixation. Of these, Kirschner wire is a simple method relatively and correct positioning of the wire achieves rigid fixation. But many open reduction methods for mandibular subcondylar fractures require extraoral approach. The extraoral approach has some problems, the facial scar and the risk of facial nerve injury. On the other hand, the intraoral approach eliminates the potency of the facial scar and the facial nerve injury, but is difficult to access the operation site. Since the intraoral approach was first described by Silverman (1925), the intraoral approach to the mandibular condyle has been developed with modifications. The purpose of this article is to describe the intraoral technique with the Kirschner wire on mandibular subcondylar fractures. Conclusion : The intraoral reduction with Kirschner wire on mandubular subcondylar fractures avoids the facial scar and facial nerve injury and is simple method to the extraoral approach. And it has minimal morbidity and better esthetics.

  • PDF

Subacute Osteomyelitis on Phalangeal Bone Resulting from Multiple Kirschner Pin Fixation: Case Report (원위지 골절에 K-강선을 이용한 비관혈적 정복술 후 생긴 아급성 골수염 1례)

  • Kim, Jae Woo;Choi, Hwan Jun;Kim, Mi Sun;Kim, Jun Hyuk
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.409-412
    • /
    • 2007
  • Purpose: Percutaneous Kirschner wire fixation is common method for hand fracture. It is simple but has risk of ascending infection through the pin and bony injury by multiple drilling. Ascending infection through pin tract is mostly superficial and can be treated with antibiotics and aseptic dressing. This is a case review of subacute osteomyelitis on phalangeal bones after Kirschner wire fixation with literature review. Methods: A 40-years-old man with distal phalangeal fracture on right second finger is presented. He went to a local clinic and had percutaneous Kirschner wire fixation under local anesthesia. He was transferred to our hospital for ulcerative wound on DIP joint at 4 weeks after operation. Radiography showed osteolytic change around medulla of middle and distal phalanges, leading to diagnosis of a subacute osteomyelitis. We treated it with amputation at the level of shaft of middle phalanx. Results: The postoperative course was uneventful. We thought several possible reasons for osteomyelitis in our case. First, it could resulted from ascending infection through the wire. Second, it could be resulted from a bony burn by repeated drilling. And bony necrosis could be a consequence of arterial insufficiency caused by 2 pin insertion. Conclusion: We suggest that a precise pinning based on accurate anatomical understanding is required for a percutaneous Kirschner wire fixation. The frequency of drilling should be minimized. Careful observation and patient education for pin site care are essential.

The Treatment for Mandibular Condyle Fracture of Children by a Threaded Kirshcner Wire and External Rubber Traction (Threaded Kirschner Wire와 외부 고무줄 견인을 통한 소아 하악골 관절돌기 골절의 치료)

  • Nam, Doo Hyun;Kwon, Ino;Ahn, Hyung Sik;Kim, Jun Hyuk;Lee, Young Man
    • Archives of Plastic Surgery
    • /
    • v.36 no.2
    • /
    • pp.221-224
    • /
    • 2009
  • Purpose: The treatment of children mandibular condyle fracture that is severely displaced is controversial. The conservative treatment of it may lead to complications - mandibular deficiency, asymmetry, malocclusion and temporomandibular joint dysfunction. Moreover, open reduction carries risks for growth retardation, facial nerve injury, scarring and joint stiffness. The aim of this article is to present an alternative technique of the treatment by using a threaded Kirschner wire and external rubber traction. Materials: From November 2005 to May 2008, three patients underwent the management by using a threaded Kirschner wire and external rubber traction. A threaded Kirschner wire was inserted in the condylar segment by using a C-arm. We applied the external rubber traction, and we reducted the segment progressively until complete reduction. The mandibular - maxillary fixations were removed after 3 weeks, and patients went into training for mouth opening. Results: The technique didn't result in complications - joint dysfunction, facial nerve injury, sore, infection and nonunion during follow - up period. Radiologic follow - up examinations revealed correct reduction in all patients. In all cases, we found restoration of preinjury occlusion and temporomandibular joint function. Conclusions: Closed reduction of children mandibular condyle fracture by using a threaded Kirschner wire and external rubber traction did achieve anatomic reduction and restore mandibular height. This alternative technique is simple, effective, inexpensive, easy to apply and minimally invasive.

Comparison between Two Kirschner Wire Fixation and Three Wire Fixation, in Treating of Metacarpal Neck Fracture Using Multiple Retrograde Kirschner Wire Fixation (다발성 역행성 K 강선을 이용한 중수골 경부 골절의 치료에서 2개의 강선과 3개의 강선 사용군의 비교)

  • Kwak, Sang-Ho;Lee, Young Ho;Seo, Gil Joon;Baek, Goo Hyun
    • Journal of Trauma and Injury
    • /
    • v.28 no.2
    • /
    • pp.55-59
    • /
    • 2015
  • Purpose: To compare clinical and radiographic outcomes of between two and three Kirschner wire(K-wire) intramedullary fixation for fractures in the neck of the metacarpal bone. Methods: A single institutional retrospective review identified 28 cases of metacarpal fractures between March 2010 and August 2014. Each of the cases met the inclusion criteria for closed, extra-articular fractures of the neck of the metacarpal bone. The patient groups were divided by the number of K-wire. Outcomes were compared for range of motion of the metacarpophalangeal joint, radiographic parameters, and period until union. Results: The fractures were treated with either 2 Kirschner wire fixation (n=10) or 3 Kirschner wire fixation (n=18). The active range of motion of metacarpophalangeal joint and radiographic result showed no statistically significant difference between the two groups. The mean union period was 5.9 weeks. However, four cases suffered distal head perforation in 2 K-wire fixation group and one case in 3 K-wire fixation group. Conclusion: Multiple retrograde intramedullary Kirschner wire fixation is a good treatment of choice for fractures in the neck of the metacarpal bone. To prevent metacarpal head perforation, it is preferred to use three K-wires than two K-wires.

  • PDF

Inferomedially impacted zygomatic fracture reduction by reverse vector using an intraoral approach with Kirschner wire

  • Jang, Jin Woo;Cho, Jaeyoung;Burm, Jin Sik
    • Archives of Plastic Surgery
    • /
    • v.48 no.1
    • /
    • pp.69-74
    • /
    • 2021
  • Background In inferomedially rotated zygomatic fractures sticking in the maxillary sinus, it is often difficult to achieve complete reduction only by conventional intraoral reduction. We present a new intraoral reduction technique using a Kirschner wire and its clinical outcome. Methods Among 39 inferomedially impacted zygomatic fractures incompletely reduced by a simple intraoral reduction trial with a bone elevator, a Kirschner wire (1.5 mm) was vertically inserted from the zygomatic body to the lateral orbital rim in 17 inferior-dominant rotation fractures and horizontally inserted to the zygomatic arch in nine medial-dominant and 13 bidirectional rotation fractures. A Kirschner wire was held with a wire holder and lifted in the superolateral or anterolateral direction for reduction. Following reduction of the zygomaticomaxillary fracture, internal fixation was performed. Results Fractures were completely reduced using only an intraoral approach with Kirschner wire reduction in 33 cases and through an additional lower lid or transconjunctival incision in six cases. There were no surgical complications except in one patient with undercorrection. Postoperative 6-month computed tomography scans showed complete bone union and excellent bone alignment. Four patients experienced difficulty with upper lip elevation; however, these problems spontaneously resolved after manual tissue lump massage and intralesional steroid (Triamcinolone) injection. Conclusions We completely reduced infraorbital rim fractures, zygomaticomaxillary buttresses, and zygomaticofrontal suture fractures in 84% of patients through an intraoral approach alone. Intraoral Kirschner wire reduction may be a useful option by which to obtain effective and powerful reduction motion of an inferomedially rotated zygomatic body.

Reduction of comminuted fractures of the anterior wall of the frontal sinus using threaded Kirschner wires and a small eyebrow incision

  • Lee, Da Woon;Kwak, Si Hyun;Choi, Hwan Jun;Kim, Jun Hyuk
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.5
    • /
    • pp.220-227
    • /
    • 2022
  • Background: Frontal sinus fractures are relatively rare. Their surgical management significantly differs depending on whether the posterior wall is invaded and the clinical features vary. A bicoronal incision or endoscopic approach can be used. However, the minimally invasive approach has been attracting attention, leading us to introduce a simple and effective surgical method using multiple-threaded Kirschner wires. Methods: All patients had isolated anterior wall fractures without nasofrontal duct impairment. The depth from the skin to the posterior wall was measured using computed tomography to prevent injury. The edge of the bone segment on the skin was marked, a threaded Kirschner wire was inserted into the center of the bone segment, and multiple Kirschner wires were gently reduced simultaneously. Results: Surgery was performed on 11 patients. Among them, seven patients required additional support for appropriate fracture reduction. Therefore, a periosteal elevator was used as an adjunct through a small sub-brow incision because the reduction was incomplete with the Kirschner wire alone. The reduction results were confirmed using facial bone computed tomography 1 to 3 days postoperatively. The follow-up period was 3 to 12 months. Conclusion: The patients had no complications and were satisfied with the surgical results. Here we demonstrated an easy and successful procedure to reduce a pure anterior wall frontal sinus fracture via non-invasive threaded Kirschner wire reduction.

Forehead Reconstruction with Hydroxyapatite Cement(MimixTM) and the Check Framework (Hydroxyapatite Cement(MimixTM)와 격자틀을 이용한 전두부 재건술)

  • Cho, Hyun Woo;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.219-222
    • /
    • 2008
  • Purpose: The purpose of this study is to develop hydroxyapatite cement simplified procedures for reconstruction of craniofacial deformities. Due to its expense and characteristics of quick hardening time, it may be inappropriate for forehead reconstruction or augmentation. Therefore we hear by introduce a more precise, easy and cheap method. The authors report forehead reconstruction with hydroxyapatite cement for a patient who suffered from craniofacial deformity. Methods: Case report and literature review. Results: A 35 year old man came to us with forehead and temporal area depression. He had a history of brain operations due to traumatic epidural hematoma. A physical exam showed an evidence of right side forehead weakness sign. Authors made RP model of his skull and applied check framework with Kirschner's wires for measuring accurate volume and contour on the depressed right side forehead area on the RP model. After complete exposure of defect area by bicoronary insicion, absorbable plate which applied on skull area was removed. Using three Kirschner's wires, authors made check framework on the right forehead lively and fixed with 2-hole miniplates on the boundary of the defect. After checking asymmetry, hydroxyapatite was applied on check shape framework just above Kirschner's wire. After removing Kirschner's wire, we corrected minimal unbalance and contour with bur. Conclusion: Check framework with Kirschner's wire was very convenient and cost saving methods for forehead reconstruction with hydroxyapatite cement.

Unusual Migration of Kirschner's Wire into Intervertebral Foramen after Lateral Clavicle Fracture Fixation - A Case Report

  • Lee, Jin-Ho;Chung, Jae-Yoon;Kim, Myung-Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.2
    • /
    • pp.77-79
    • /
    • 2014
  • The migration of metallic devices such as Kirschner's wire (K-wire) from the shoulder is a well-recognized and significant complication of operation, the wire ending up in the lungs, the heart, the esophagus, the aorta or the subclavian artery. However, spinal migration is very rare. We report the case of a 72-year-old female patient with K-wire migration into the C7-T1 intervertebral foramen, 2 months after surgery for a lateral end fracture of left clavicle.