Interplay between Defect Propagation and Surface Hydrogen in Silicon Nanowire Kinking Superstructures

  • 신내철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.221.1-221.1
    • /
    • 2015
  • The vapor-liquid-solid (VLS) method, where the "liquid" catalytic droplets collecting atoms from vapor precursors build the solid crystal layers via supersaturation, is a ubiquitous technique to synthesize 1-dimensional nanoscale materials. However, the lack of fundamental understanding of chemical information governing the process inhibits the rational route to the structural programming. By combining the in situ or operando IR spectroscopy with post-growth high resolution electron microscopy, we show the strong correlation between the surface chemical species concentration and nanowire structures. More specifically, the critical role of surface adsorbed hydrogen, generated from the decomposition of Si2H6 precursor on the interplay between nanowire / kinking and the defect propagation is demonstrated. Our results show that adsorbed hydrogen atoms are responsible for selecting -oriented growth and indicate that a twin boundary imparts structural coherence. The twin boundary, only continuous at / kinks, reduces the symmetry of the trijunction and limits the number of degenerate directions available to the nanowire. These findings constitute a general approach for rationally engineering kinking superstructures and also provide important insight into the role of surface chemical bonding during VLS synthesis.

  • PDF

전기장이 강유전체 내의 균열킹크에 미치는 영향 (Effect of Electric Fields on Crack Kinking in Ferroelectrics)

  • 이종식;범현규
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1206-1210
    • /
    • 2003
  • Effect of transverse electric field on crack kinking in ferroelectric ceramics subjected to purely electric loading is investigated. It is shown that the shape and size of the domain switching zone depends strongly on the direction of the applied electric field as well as the ratio of the transverse electric field to the coercive electric field. Under small-scale conditions, mode I and II stress intensity factors induced by ferroelectric domain switching are numerically obtained. The crack kinking in ferroelectrics is also discussed.

  • PDF

Energy release rate for kinking crack using mixed finite element

  • Salah, Bouziane;Hamoudi, Bouzerd;Noureddine, Boulares;Mohamed, Guenfoud
    • Structural Engineering and Mechanics
    • /
    • 제50권5호
    • /
    • pp.665-677
    • /
    • 2014
  • A numerical method, using a special mixed finite element associated with the virtual crack extension technique, has been developed to evaluate the energy release rate for kinking cracks. The element is two dimensional 7-node mixed finite element with 5 displacement nodes and 2 stress nodes. The mixed finite element ensures the continuity of stress and displacement vectors on the coherent part and the free edge effect. This element has been formulated starting from a parent element in a natural plane with the aim to model different types of cracks with various orientations. Example problems with kinking cracks in a homogeneous material and bimaterial are presented to assess the computational accuracies.

Measurement of the Time Taken for Initial Water Discharge According to the Number of Kinks in the Fire Hose of the Indoor Hydrant System

  • Hong, Suk-Hwan;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권3호
    • /
    • pp.360-366
    • /
    • 2021
  • In this study, we tried to examine how the kinking of the fire hose affects the time taken for initial water discharge by measuring and analyzing the time taken for initial water discharge with different number of kinks at different locations of the hose. The average time taken for initial water discharge was obtained by measuring the time in the unkinked state of the fire hose. Based on this standard, we conducted the experiment by selecting the kinking locations in the hose near the water outlet and nozzle, and setting the number of kinks to 3, 6, 9, and 12. The results of this study are as follows: First, if the fire hose has 5 kinks or more near the nozzle, no water was released. Second, when comparing the case of no kinks and 4 kinks near the nozzle, there was no significant difference in the time taken for initial water discharge. Third, when the fire hose was kinked 10 times near the outlet, the time required for initial water discharge increased by 1.62 seconds on average compared to the case with no kinking, but there was no problem with water discharge. Lastly, regarding the kinking locations of the fire hose, it was found that the greater the number of kinks near the nozzle than near the outlet, the greater the effect on the discharge. As a result, it is concluded that it would be preferable to install non-kinking devices near the nozzle of the fire hose.

Compression failure and fiber-kinking modeling of laminated composites

  • Ataabadi, A. Kabiri;Ziaei-Rad, S.;Hosseini-Toudeshky, H.
    • Steel and Composite Structures
    • /
    • 제12권1호
    • /
    • pp.53-72
    • /
    • 2012
  • In this study, the physically-based failure models for matrix and fibers in compression and tension loading are introduced. For the 3D stress based fiber kinking model a modification is proposed for calculation of the fiber misalignment angle. All of these models are implemented into the finite element code by using the advantage of damage variable and the numerical results are discussed. To investigate the matrix failure model, purely in-plane transverse compression experiments are carried out on the specimens made by Glass/Epoxy to obtain the fracture surface angle and then a comparison is made with the calculated numerical results. Furthermore, shear failure of $({\pm}45)_s$ model is investigated and the obtained numerical results are discussed and compared with available experimental results. Some experiments are also carried out on the woven laminated composites to investigate the fracture pattern in the matrix failure mode and shown that the presented matrix failure model can be used for the woven composites. Finally, the obtained numerical results for stress based fiber kinking model and improved ones (strain based model) are discussed and compared with each other and with the available results. The results show that these models can predict the kink band angle approximately.

KINKING DEFORMATION OF PVD UNDER CONSOLIDATION OF NATURAL CLAY LAYER

  • Aboshi, Hisao;Inoue, Toshiyuki;Yamada, Yoshimitsu
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.349-356
    • /
    • 2003
  • Almost every material of PVD (Prefabricated Vertical Drain) has the fatal problem on the condition - the length must shorten with the settlement of the surrounding grounds - which all PVDs must satisfy. Kinking deformation by buckling of PVD due to consolidation settlement Is discussed in this paper. A new testing device to clarify the deformation of PVD under consolidation of surrounding clay was developed and the fiber drain and a PVD made of plastics were compared under the same condition of consolidation using natural clay specimens. The results are also shown in this paper.

  • PDF

Influence of elastic T-stress on the growth direction of two parallel cracks

  • Li, X.F.;Tang, B.Q.;Peng, X.L.;Huang, Y.
    • Structural Engineering and Mechanics
    • /
    • 제34권3호
    • /
    • pp.377-390
    • /
    • 2010
  • This paper studies fracture initiation direction of two parallel non-coplanar cracks of equal length. Using the dislocation pile-up modelling, singular integral equations for two parallel cracks subjected to mixed-mode loading are derived and the crack-tip field including singular and non-singular terms is obtained. The kinking angle is determined by using the maximum hoop stress criterion, or the ${\sigma}_{\theta}$-criterion. Results are presented for simple uniaxial tension and biaxial loading. The biaxiality ratio has a noticeable influence on crack growth direction. For the case of biaxial tension, when neglecting the T-stress the crack branching angle is overestimated for small crack inclination angles relative to the largest applied principal stress direction, and underestimated for large crack inclination angles.

횡전기장이 강유전체 세라믹의 파괴거동에 미치는 영향 (Effect of Transverse Electric Fields on Fracture Behavior of Ferroelectric Ceramics)

  • 이종식;범현규;정경문
    • 한국정밀공학회지
    • /
    • 제22권2호
    • /
    • pp.120-125
    • /
    • 2005
  • Effect of transverse electric fields on fracture behavior in ferroelectric ceramics under purely electrical loading is investigated. It is shown that the shape and size of the domain switching zone depend strongly on the ratio of the transverse electric field to the coercive electric field as well as the direction of the applied electric field. Under small-scale conditions, the crack-tip mode I and II stress intensity factors induced by ferroelectric domain switching are numerically obtained. The crack kinking in ferroelectric ceramics is also discussed.

Mechanics of kinking and buckling of plastic board drains

  • Madhav, Madhira R.;Park, Yeong Mog;Miura, Norihiko
    • Structural Engineering and Mechanics
    • /
    • 제3권5호
    • /
    • pp.429-443
    • /
    • 1995
  • The deformational response of plastic board drains installed to accelerate consolidation of soft soils, is examined as a problem of downdrag. The drain is modelled as a beam-column in which the axial load increases nonlinearly with depth. The soil response is represented by the Winkler medium whose coefficient of subgrade modulus increases linearly with depth. The governing equations for the drain-soil system are derived and solved as an eigenvalue problem. The critical buckling loads and the shape of the drain are obtained as functions of the normalized subgrade modulus of the soil at the top, the parameters signifying the variation of axial load along the length of the drain and the increase of subgrade modulus with depth. The derived deformed shapes of the drain are consistent with the observed ones.