• Title/Summary/Keyword: Kinematic parameters

Search Result 414, Processing Time 0.032 seconds

Kinematic optimal design and analysis of kinematic/dynamic performances of a 3 degree-of-freedom excavator subsystem (3 자유도 굴착기 부속 시스템의 기구학적 최적 설계와 기구학/동력학 성능 해석)

  • Kim, Whee-Kuk;Han, Dong-Young;Yi, Byung-Ju
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.4
    • /
    • pp.422-434
    • /
    • 1997
  • In this paper, a two-stage kinematic optimal design for a 3 degree of-freedom (DOF) excavator subsystem, which consists of boom, arm and bucket, is performed. The objective of the first stage is to find the optimal parameters of the joint-actuating mechanisms which maximize the force-torque transmission ratio between the hydraulic actuator and the rotating joint. The objective of the second stage is to find the optimal link parameters which maximize the isotropic characteristic of the excavator subsystem throughout the workspace. It is illustrated that kinematic/dynamic performances of the kinematically optimized excavator subsystem have improved compared to those of original HE280 excavator, with respect to three performance indices such as maximum load handling capacity, maximum velocity capability, and acceleration capability.

  • PDF

Kinematic Calibration Method for Redundantly Actuated Parallel Mechanisms (여유구동 병렬기구의 기구학적 보정)

  • 정재일;김종원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.355-360
    • /
    • 2002
  • To calibrate a non-redundantly actuated parallel mechanism, one can find actual kinematic parameters by means of geometrical constraint of the mechanism's kinematic structure and measurement values. However, the calibration algorithm for a non-redundant case does not apply fur a redundantly actuated parallel mechanism, because the angle error of the actuating joint varies with position and the geometrical constraint fails to be consistent. Such change of joint angle error comes from constraint torque variation with each kinematic pose (meaning position and orientation). To calibrate a redundant parallel mechanism, one therefore has to consider constraint torque equilibrium and the relationship of constraint torque to torsional deflection, in addition to geometric constraint. In this paper, we develop the calibration algorithm fir a redundantly actuated parallel mechanism using these three relationships, and formulate cost functions for an optimization algorithm. As a case study, we executed the calibration of a 2-DOF parallel mechanism using the developed algorithm. Coordinate values of tool plate were measured using a laser ball bar and the actual kinematic parameters were identified with a new cost function of the optimization algorithm. Experimental results showed that the accuracy of the tool plate improved by 82% after kinematic calibration in a redundant actuation case.

  • PDF

A Calibration of Kinematic Differences between the Robot Model in OLP and Actual SCARA Robot

  • Ahn, Cheol-Ki;Lee, Min-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1998.10a
    • /
    • pp.111-116
    • /
    • 1998
  • In this study, we try to coincide virtual robot system in an OLP(off-line programming) with actual robot system even though kinematic differences between them are made. The virtual robot in the OLP may be modeled according to kinematics of the actual robot system. However, it is a complicated problem to find exactly all kinematic parameters of actual robot and environment. In this paper, an automated calibration method is proposed In order to find some kinematical parameters which are necessary for the modeling of a robot and environment in the OLP. It is applicable to SCARA robot for assembly task. In this method, a well-marked worktable of environment Is regarded as reference coordinate frame. The robot detects some marks on the worktable through sensors attached to the end-effector. The necessary parameters are calculated from the data of the robot joint variables when the robot detects the mark. The model in the OLP is modified by the parameters.

  • PDF

Determination of Identifiable Parameters and Selection of Optimum Postures for Calibrating Hexa Slide Manipulators

  • Park, Jong-Hyuck;Kim, Sung-Gaun;Rauf, Abdul;Ryu, Je-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2737-2742
    • /
    • 2003
  • Kinematic calibration enhances absolute accuracy by compensating for the fabrication tolerances and installation errors. Effectiveness of calibration procedures depends greatly on the measurements performed. While the Cartesian postures are measured completely, all of the geometric parameters can be identified to their true values. With partial pose measurements, however, few geometric parameters may not be identifiable and effectiveness of the calibration results may vary significantly within the workspace. QR decomposition of the identification Jacobian matrix can reveal the non-identifiable parameters. Selecting postures for measurement is also an important issue for efficient calibration procedure. Typically, the condition number of the identification Jacobian is minimized to find optimum postures. This paper investigates identifiable parameters and optimum postures for four different calibration procedures - measuring postures completely with inverse kinematic residuals, measuring postures completely with forward kinematics residuals, measuring only the three position components, and restraining the mobility of the end-effector using a constraint link. The study is performed for a six degree-of-freedom fully parallel HexaSlide type paralle manipulator, HSM. Results verify that all parameters are identifiable with complete posture measurements. For the case of position measurements, one and for the case of constraint link, three parameters were found non-identifiable. Optimal postures showed the same trend of orienting themselves on the boundaries of the search space.

  • PDF

The test-retest reliability of gait kinematic data measured using a portable gait analysis system in healthy adults

  • An, Jung-Ae;Byun, Kyung-Seok;Lee, Byounghee
    • Journal of Korean Physical Therapy Science
    • /
    • v.27 no.3
    • /
    • pp.25-34
    • /
    • 2020
  • Background: Gait analysis is an important measurement for health professionals to assess gait patterns related to functional limitations due to neurological or orthopedic conditions. The purpose of this study was to investigate the reliability of the newly developed portable gait analysis system (PGAS). Design: Cross-sectional design. Test-retest study. Methods: The PGAS study was based on a wearable sensor, and measurement of gait kinematic parameters, such as gait velocity, cadence, step length and stride length, and joint angle (hip, knee, and ankle) in stance and swing phases. The results were compared with a motion capture system (MCS). Twenty healthy individuals were applied to the MCS and PGAS simultaneously during gait performance. Results: The test-retest reliability of the PGAS showed good repeatability in gait parameters with mean intra-class correlation coefficients (ICCs) ranging from 0.840 to 0.992, and joint angles in stance and swing phase from 0.907 to 0.988. The acceptable test-retest ICC was observed for the gait parameters (0.809 to 0.961), and joint angles (0.800 to 0.977). Conclusion: The results of this study indicated that the developed PGAS showed good grades of repeatability for gait kinematic data along with acceptable ICCs compared with the results from the MCS. The gait kinematic parameters in healthy subjects can be used as standard values for adopting this PGAS.

Effect of Fertilization Promoting Peptide on Kinematic Parameters, Capacitation and Acrosome Reaction in Human Spermatozoa (Fertilization Promoting Peptide가 사람 정자의 운동양태, 수정능력획득 및 첨체반응에 미치는 영향)

  • Kang, Hee-Gyoo;Kim, Myo-Kyung;Kim, Dong-Hoon;Han, Sung-Won;Choi, Do-Hyun;Lee, Ho-Joon;Kim, Moon-Kyoo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.27 no.2
    • /
    • pp.201-209
    • /
    • 2000
  • Objective: This study has been carried out to evaluation the effect of fertilization promoting peptide (FPP) on the kinematic parameters, capacitation and acrosome reaction of the frozen-thawed human spermatozoa. Methods: After FPP treatment, we examined kinematic parameters, capacitation and acrosome reaction, using the methods of computer-aided sperm analysis (CASA) and chlortetracycline (CTC) fluorescence analysis. Results: We have obtained the evidence that FPP can promote the capacitation and inhibit the spontaneous acrosome reaction of frozen-thawed human spermatozoa in vitro. FPP ($25{\sim}100$ nM) induced a significant increase in the proportion of B-pattem capacitated spermatozoa, and a significant decrease in the proportion of F-pattem uncapacitated ones without significant stimulation of acrosomal exocytosis. In the kinematic parameters treatment, FPP treated groups maint3ined higher LIN, BCF and STR than those of control. The VAP, VSL, VCL and ALH were not different. Therefore it is suggested that FPP in human seminal plasma may play a positive role in promoting human sperm function.

  • PDF

The Analysis of Trajectory Tracking Error Caused by the Tolerance of the Design Parameters of a Parallel Kinematic Manipulator (병렬로봇의 설계 공차가 궤적 정밀도에 미치는 영향 분석)

  • Park, Chanhun;Park, DongIl;Kim, Doohyung
    • The Journal of Korea Robotics Society
    • /
    • v.11 no.4
    • /
    • pp.248-255
    • /
    • 2016
  • Machining error makes the uncertainty of dimensional accuracy of the kinematic structure of a parallel robot system, which makes the uncertainty of kinematic accuracy of the end-effector of the parallel robot system. In this paper, the tendency of trajectory tracking error caused by the tolerance of design parameters of the parallel robot is analyzed. For this purpose, all the position errors are analyzed as the manipulator is moved on the target trajectory. X, Y, Z components of the trajectory errors are analyzed respectively, as well as resultant errors, which give the designer of the manipulator the intuitive and deep understanding on the effects of each design parameter to the trajectory tracking errors caused by the uncertainty of dimensional accuracy. The research results shows which design parameters are critically sensitive to the trajectory tracking error and the tendency of the trajectory tracking error caused by them.

Development of Kinematic Analysis Technique for Structural Design of Single Arm type Pantograph (싱글암형 팬터그래프 구조설계를 위한 기구해석기법 개발)

  • Jeong, Gyeong-Ryeol;Park, Su-Hong;Kim, Hwi-Jun;Bae, Jeong-Chan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.4
    • /
    • pp.610-618
    • /
    • 2001
  • Pantograph, which collects current from cartenary system, is one of the important parts of high-speed train. Kinematic analysis is one of the key technologies for pantograph design and includes joint trajectories, reaction forces, and the required moment of main shaft calculations. The kinematic analysis, however, is very complex and time-consuming process. In this study PC based pantograph kinematic analysis software using graphical user interface tool was developed for the easy evaluations of kinematic characteristics necessary in pantograph design process.

Sensitivity Analysis Using a Symbolic Computation Technique and Optimal Design of Suspension Hard Points (기호계산을 이용한 현가장치의 민감도 해석 및 설계점의 최적 설계)

  • Chun, Hung-Ho;Tak, Tae-Oh
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.26-36
    • /
    • 1999
  • A general procedure for determining the optimum location of suspension hard points with respect to kinematic design parametes is presented. Suspensions are modeled as connection of rigid bodies by ideal kinematic joints. Constraint equations of the kinematic joints are expressed in terms of the generalized coordinates and hard points. By directly differentiating the constraint equations with respect to the hard points, kinematic sencitivity equations are obtained. In order to cope with algebraic complexity associated with the differentiation process, a symbolic computation technique is used. A performance index is defined in terms of static design parameters such as camber, caster, toe, ect.. Gradient of the performance index can be analytically computed from the kinematic sensitivity equations. Optimization results show the effectiveness and validity of the procedure, which is applicable to any type of suspension if its kinematic configurations are given.

  • PDF

Calibration of Parallel Manipulators using a New Measurement Device (새로운 측정장비를 이용한 병렬구조 로봇의 보정에 관한)

  • Rauf, Abdul;Kim, Sung-Gaun;Ryu, Je-Ha
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1494-1499
    • /
    • 2003
  • Kinematic calibration is a process whereby the actual values of geometric parameters are estimated so as to minimize the error in absolute positioning. Measuring all components of Cartesian posture, particularly the orientation, can be difficult. With partial pose measurements, all parameters may not be identifiable. This paper proposes a new device that can be used to identify all kinematic parameters with partial pose measurements. Study is performed for a six degree-of-freedom fully parallel Hexa Slide manipulator. The device, however, is general and can be used for other parallel manipulators. The proposed device consists of a link with U joints on both sides and is equipped with a rotary sensor and a biaxial inclinometer. When attached between the base and the mobile platform, the device restricts the end-effector's motion to five degree-of-freedom and can measure position of the end-effector and one of its rotations. Numerical analyses of the identification Jacobian reveal that all parameters are identifiable. Computer simulations show that the identification is robust for the errors in the initial guess and the measurement noise.

  • PDF